INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

Similar documents
CONNECTION ASSESSMENT & APPROVAL PROCESS. Cardinal Substation Modification of 115kV Substation

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

School of Electrical and Information Engineering. ELEC High Voltage. University of Sydney. Dr Keith Mitchell. Engineering

SWITCHGEAR DIVISION PRODUCT PROFILES

Pretest Module 29 High Voltage Unit 1

Key features. DESIGNS: - Conservator type - Hermetically sealed

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches

500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

MOBILE SUBSTATION DESIGN Brad Bozich & Vitor Vieira 2755 Northwoods Parkway Norcross, Georgia

NXPLUS C Single busbar. Maintenance-free for lifetime

COMPACT SUBSTATION GUIDE

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

www. ElectricalPartManuals. com lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts Ratings:

Chapter 6 Generator-Voltage System

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

Distribution transformers Efficiency over life-cycle

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled

Unit Substation Transformers 5 and 15 KV Class

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Title Electrical Technical Maintenance Coding System. Reference Number PMP 01 (RIC Standard: EP SP)

NEW Solutions for Underground System Growth

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

Extensible Unit - VCE2a

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.

Gas Insulated Metal-clad Switchgear, HMGS!

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

This tender addendum and clarification forms part of the Request for Proposal and Contract documents, and modifies them as follows:

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Solid Dielectric, Three Phase Reclosers CATALOG VS11

Power Voltage Transformers for Air Insulated Substations

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

Unitole UP kv Primary substations Motor control centres

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Unitole UP kv Primary substations Motor control centres

Switchgear and Distribution Systems for Engineers and Technicians

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

PASS M0. Innovative solutions for distribution substations up to 170 kv

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

First Applications on AltaLink s Network. Roggero Ciofani, P. Eng. Colin Clark, P. Eng.

Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C up to 24 kv, SF 6 -Insulated. Medium-Voltage Switchgear Catalog HA 35.

Substation Committee K2 TF1 of the GIS Subcommittee GIS/GIL/SF 6 -Tutorials

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Transformer Protection

Modular medium-voltage switchgear. NorMax

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Wheeler Ridge Junction Substation Project Description and Functional Specifications for Competitive Solicitation

SWITCHBOARDS (LV and MV)

ABB Transformadores para aplicaciones solares y eolicas

www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

Epoxy Technology Embedded Poles

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

University of Houston Master Construction Specifications Insert Project Name

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016

SF 6. -insulated Ring Main Unit, SafeRing 36 and -insulated Compact Switchgear SafePlus kv ABB

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

EMPAC Metal enclosed capacitor bank for wind applications

Service Entrance Methods

Power systems Protection course

Substation Maintenance Training

Solid Dielectric, Single Phase Recloser

Tradition. Technology. Innovation.

DRY TYPE TRANSFORMERS

Single phase pole mounted. 11kV. Electrical Engineer KEU ID#:

Question Set(2017) Switch Gear & protection(5 th SEm) 9. Explain the construction and operating principle with proper diagram:

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

V. Design, Application, Maintenance & Operation Technical Requirements

Transformer Components & Accessories

Product catalogue. ABB AS, Power Products Division SF 6. -insulated Ring Main Unit, SafeRing 36 and -insulated Compact Switchgear SafePlus 36

Modular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.

YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

GAS INSULATED VOLTAGE TRANSFORMERS.

Close-Open (Short-Circuit) Time Results Interpretation

EE 741 Over-voltage and Overcurrent. Spring 2014

September 2008 TEC, INTELLIGENT MONITORING SYSTEM

Accelerate your grid modernization with smart RMUs. Ring main units with smart grid-ready feeder automation

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

Transcription:

MOBILE SUBSTATIONS Energy Solution

INTERNATIONAL FAIR

MOBILE SUBSTATIONS ENERGY SOLUTION Complete design for energy s generations, transmission and distribution

Mobile Substations Applications of Inesing Mobile Substations:

Components High Voltage Section: Transformer Section: Bushings Bushings can be supplied as standard ceramic or with silicon insulation. Bushings are selected in accordance to voltage and current requirements. Transformer Core or Shell type, with same thermal, mechanical, dielectric and economic advantages of Tamini power transformers. - Compact design to optimize the transformer volume and reduce its total weight. - Designed to handle average winding temperature rise of 65, 75 or 95 C. - NOMEX/ pressboard or NOMEX insulation Forced oil and air cooling (FOA) Forced oil cooling consists of a seamless tubular cooler heat exchanger plus a submerged pump and motor.a bearing wear monitor is proposed which stops the pump in the event bearing wear has reached and unsafe level. Lightning Arrester Protection level in coordination with transformer insulating level. In case windings have two or more voltage levels, multiple lightning arresters are used (one for each voltage level), which are interchanged at the same time the winding voltage level is changed. Disconnecting Switch Single or three pole with capacity to interrupt transformer magnetizing currents. Can be operated locally or from a remote location. HV Breaker Dead tank SF6 circuit breakers are commonly used, with motorwound spring operating mechanism, operable on even loss of auxiliary power. Tap Changers The transformer could have one or more de-energized tap changers (DTC) on high or low voltage winding, delta-wye switches or on load tap changer (LTC) on high or low voltage winding. On all cases, external operating mechanism allows the voltage connections to be changed without opening the tank. LTC may be Resistive or inductive type and DTC may be Series-Parallel type. High temperature liquid Several high temperature oil types may be used for the transformer: Midel, FR3, Silicone oil or Beta fluid. Monitoring Equipment Online monitoring is an important tool for early fault detection and real time condition assessment. IEM may provide online DGA and moisture monitoring, online PD monitoring and temperature and load monitoring. S&C Circuit Switcher Circuit switchers feature SF6 gas filled interrupters and singlepressure puffer technology for restrike-free, non-current chopping performance. Used when limited capacity due to space or alarm conditions are presented. Power Fuses Normally mounted between the lightning arrester and the transformer. Selected in accordance with voltage and current ratings. Potential transformer and current transformer Used to reduce voltage to 120 V and current to 5A for metering and protective relays. They also provide insulation between the primary and secondary circuits. For 25 kv and above PT's and CT's are suitable for outdoor use and below this range for indoors or outdoors in accordance with customer specifications.

INESING MOBILE SUBSTATION 132/33 kv

INESING MOBILE SUBSTATION 33/11 kv

AUXILIARY TRANSFORMER FOR CONTROL POWER Oil Immersed, single or three phase and permanently connected to the low voltage of the main transformer. Low Voltage Breaker A vacuum or SF6 breaker normaly provides low voltage protection agains short circuit current. The breaker and its controls are mounted on the trailer's low voltage end or in a different trailer depending on customer specifications. Three phase, metal eclosed, metal clad single busbar switchgear has a hermetically sealed primary enclosure, which provides protection against accidental contact ans is independent of environmental effects. Protectiv Relays For protection against abnormal transformer differentials and sudden gas pressure. A wide variety of relays can be installed to meet specification needs.

Medium Voltage Section: Metal-Clad standardized medium voltage switchboards up to 36kV

RETROFITTING Optimal Solution for the Modernization of Distribution Plants

LV Distribution Switchboard Optimal Solutions for the LV Distribution Switchboards

COMPACT SUBSTATIONS Compact Substation up to 36kV

COMPACT SUBSTATIONS Compact Substation up to 36kV

BRINGS POWER ALL OVER THE WORLD