Automatic shut-off valves are necessary in combustion systems to provide reliable, positive shut off of fuels.

Similar documents
LVG SERIES. Gas Limiting Orifice Valve. Features. Benefits. Combustion Excellence Since 1888 LVG-1

PGM Prepiped Gas Manifold

North American Automatic Manual Reset and Motorized Valves

MOV MICRO OIL VALVES SELF-CLEANING

Maxon Shut-Off and Vent Valves General Purpose

North American 1599 Electro-Hydraulic Gas Shutoff Valve Bulletin 1599

Solenoid Valves. Options/Accessories - ASCO offers a wide variety of accessories and optional features to meet your specific application requirements.

ELECTRICALLY ACTUATED DOUBLE SEATED IRON - 1 1/2-2

VOG Series VOG15.01xU1 Oil Safety Shut-off Valves with Proof of Closure (POC)

Maxon Shut-Off and Vent Valves General Purpose

Valve Body Capacities/Specifications

BBC Multi-fuel Combination Beta Burner

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

BRASS BALL VALVES. CSA, UL, cul CGA 9.1 and FM Approved. Female NPT, Male NPT and Flare ends in various configurations from 3/8 to 1.0.

The New Filter Valve Technology

Packaged Gas Burner. Low CO and NOx emissions. Direct spark ignition. Factory pre-set for ease of start-up and operation

TriOx Triple Air Staged Ultra Low NOx Burner

PS AMA F (a) 0411 ( )

BBG Gas Beta Burner. Designed for low pressure air operation. Rugged heavy gauge steel construction

Compact Electric Actuated 3-Way Ball Valves T-Port, 316 Stainless Steel, Full Port 1/4 to 3/4 NPT

J Series Filters HIGH PRESSURE FILTERS. J88 Mini In-Line (Replaceable Filter) J85 Tee-Type. J82 Mini In-Line. J83 In-Line

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

NETSIAN TECHNOLOGY VALVE SCHEDULE

Features Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design

North American Manual Reset and Motorized Valves

50 HERTZ METRIC BLOWER

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

KENCO ENGINEERING COMPANY

Series 8000 Air Actuated Valves

Operators Manual ECO-AIR-IVS Internal Valve Actuation System

CYCLOPS X Purge Controller XP Version

97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel

Powers TM Controls SW 141 Differential Static Airflow Switches

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

BERMAD Waterworks. Booster Pump Control Valve Active Check Valve. 700 Series. Model 740. Features and Benefits. Major Additional Features

Features Globe Valve 2-Way & 3-Way Assembly Features:

CYCLOPS X Purge Controller SM Version

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

CYCLOPS Z Purge Indicator

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

2/2-way Solenoid Valve for liquids and gases

SKP Series SKP15 U.. Gas Valve Actuator with Safety Shutoff Function

ProMinent ProMus Hydraulic Diaphragm Metering Pumps

Electronic Control Valves

BC-VDC A TOTAL SYSTEM FOR YOUR DUST COLLECTOR DWYER INSTRUMENTS, INC. DWYER OFFERS YOU:

Burner Capacity Information, BBC 1110/2110. Burner Capacity Information, BBC 3110

Use Type C control units. Viscosity range is 100 to 10,000 SSU at operating temperature. See Bijur Engineering Manual for system limitations.

Design and Application Details

CIRCLE SEAL CONTROLS

CYCLOPS Z Purge Indicator

Locktite Manual Reset Gas Shut-Off Valves

Tightness control TC. Product brochure GB Edition 12.10

BITZER Capacity Controller for CSH Compressors Temperature Sensor

ANGLE SEAT AIR ACTUATED VALVES 2 Way (2/2)

Solenoid valves for gas VAS Double solenoid valves VCS

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

BECSys CO 2 Feeder. BECSys CO 2 Feed System Data Sheet. Description. Features

KG(X)3. Grinder Pumps. 3HP High Flow Grinder Pump (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve. Total Head (FT) Capacity (GPM)

Type Electrically Actuated Ball Valve

Crest Heating Boilers FBN(L)

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

Poppet Valves Series. Keeping the World Flowing

12AT/50AT Series Spin-On Filters

1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ

Model 788DVC DIGITAL CONTROL VALVES

Gas Electro-mechanical Valves

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

GTV Series High Pressure Control Valves

FAIL-SAFE CONTROL VALVE FOR MODULATING CONTROL OF INSTANTANEOUS WATER HEATER & HEAT EXCHANGER APPLICATIONS SERIES MODELS

Hose Length Custom Length Supply Line Options Ball Valve w/ PT UBY Strainer w/ PT and BDV

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER

Technical Data Sheet FT & FIT-1003 SERIES AIR VOLUME/ VELOCITY TRANSDUCERS. Features DESCRIPTION

High Pressure Solenoid Valves

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

VALVCON. QX-Series ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

Series: GA6-1½, GA6-2, GA7-1¼, GA7-1½

Weather-Proof Thermal Mass Flow Meter for Pipe - Duct

Electric Actuated Butterfly Valves Ductile Iron Wafer Body ASME 150# 2 to 6 Pipe

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

Pulse Width Modulation Valves. Models SPW-0 thru -7

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Design and Application Details MICRO-RATIO Valves

Check Valve AP64 P.149. Vacuum Generator Vacuum Generator Module Vacuum Generator Module AP7 & 70 AP71 AP72. Flow Switch Flow Switch (For high flow)

Valves and Valve Assemblies

Solenoid valves for gas VAS, Double solenoid valves VCS

Schuyler McElrath Gas Turbine Consultant JASC: Jansen s Aircraft Systems Controls, Inc

GV-A Manufactured by Germany s Elster GmbH High-Performance Gas Solenoid Valve for Industrial Applications

Evans Ball Valves. Evans. High Purity 316 Stainless

2/2-way Solenoid Valve with servo diaphragm

Flow-Thru Expansion Tanks

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

Technical Information Features Fast Response - Bubble Tight Sealing Small Size - 4 Inches High Single Solenoid - Only 3 Moving Parts Pilot Interchange

Electric Actuated Ball Valves 3-piece Stainless Steel, Full Port 1/4 to 3 NPT

YFC. Limit switch. Ex d. 24 operating head types

Powers TM Controls Three-way Electro-pneumatic (EP) Valve Model 2

TYPE D PRESSURE REDUCING PILOT CONTROLS 3 to 300 PSIG

Wafer Silent Check Valves

Flow Computer Installation

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

Transcription:

Hauck Manufacturing Company COMBUSTION CONTROL ACCESSORIES AUTOMATIC SHUT-OFF VALVES (ASOV) Automatic shut-off valves are necessary in combustion systems to provide reliable, positive shut off of fuels. The 5000 and 7000 series are suitable for various gaseous fuels including natural gas, vaporous propane and other clean industrial fuel gases. 5000 and 7000 valves are normally closed. All valves are sanctioned for service by major approval agencies. The ASOV series is suitable for temperatures from -20ºF to 140ºF (-28 to 60ºC). Each valve has a visual indication window and proof of closure switches. All valves are 115VAC/60 Hz. Consult factory for applications not listed (e.g., coke oven gas, 50 HZ, etc.) NOTE: Top assembly enclosure meets approval standards NEMA 1, 2, 3, 3R, 4 and 12. Automatic Shut-off Valves Hauck Part No. Connection C v Maximum Inlet Gas Pressure Maximum Operating Pressure Differential 5000-07/SMA11 62913 ¾" NPT 20 125 psig 125 psid 5000-10/SMA11 62914 1" NPT 20 125 psig 125 psid 5000-12/SMA11 62955 1 ¼" NPT 45 100 psig 100 psid 5000-15/SMA11 20618 1 ½" NPT 53 70 psig 70 psid 5000-20/SMA11 20619 2" NPT 86 70 psig 70 psid 5000-25/SMA11 20620 2 ½" NPT* 127 40 psig 40 psid 5000-30/SMA11 20621 3" NPT* 173 30 psig 30 psid 5000-CP-25/CMA11 62915 2 ½" Flanged* 304 50 psig 50 psid 5000-CP-30/CMA11 300204 3" Flanged* 423 40 psig 40 psid 5000-CP-40/CMA11 60689 4" Flanged 490 40 psig 40 psid 7000-40/HMA11 54802 4" Flanged 869 60 psig 60 psig NOTE: Valves with an * in the connection column indicate that a flanged or NPT connection is available. Use the part number listed for the connection type that is specified above. Consult Hauck for part numbers of valve connection type and body size not listed above. Model Closing Holding 5000/SMA11 2.1 amp 0.2 amp 5000 CP/CMA11 2.4 amp 0.4 amp 7000/HMA11 3.6 amp 0.12 amp (OVER) 115VAC/60Hz ASOV-1 Hauck Manufacturing Company, P.O. Box 90, Lebanon, PA 17042 Phone: 717-272-3051, Fax: 717-273-9882 www.hauckburner.com 2012 Hauck Manufacturing Company Printed in U.S.A. 10/12

AUTOMATIC SHUT-OFF VALVES (ASOV) ¾" Through 1 ½" Valves Connection A B C D G H J K 5000-07/SMA11 ¾" NPT 2.00 11.19 3.81 1.90.78 1.94.81 8.11 5000-10/SMA11 1" NPT 2.00 11.19 3.81 1.90.78 1.94.81 8.11 5000-12/SMA11 1 ¼" NPT 2.44 11.75 4.00 2.00.22 2.12 1.56 8.67 5000-15/SMA11 1 ½" NPT 2.69 12.22 4.00 2.00.38 2.12 1.68 9.14 2" Through 3" Valves Connection A B C D G H J K 5000-20/SMA11 2" NPT 3.25 13.69 4.38 2.19.44 2.25 1.88 10.60 5000-25/SMA11 2 ½" NPT 3.50 13.56 5.00 2.50.63 2.12 2.25 10.46 5000-30/SMA11 3" NPT 2.94 13.80 5.19 2.59.63 2.12 2.56 10.71 Note: Consult Hauck for dimensions of 5000-20/SMA11 and 5000-25/SMA11 with a flanged connection. ASOV-1 2012 Hauck Manufacturing Company Printed in U.S.A. 10/12

AUTOMATIC SHUT-OFF VALVES (ASOV) 2 ½" CP Through 6" Valves Connection A B H J L M N P S T 5000-CP-25/CMA11 2 ½" Flanged 4.50 14.56 2.12 2.20 3.50 2.75.75 4.00 3.75 7.50 5000-CP-30/CMA11 3" Flanged 5.22 15.29 2.24 2.60 3.75 3.00.75 4.00 4.00 8.00 5000-CP-40/CMA11 4" Flanged 5.55 15.29 2.25 2.56 4.50 3.75.75 8.00 4.50 9.00 Note: Consult Hauck for dimensions of 5000-CP-25/CMA11 and 5000-CP-30 /CMA11 with an NPT connection. 4" Through 6" 7000 Valves Connection A B E G H P R S 7000-40/HMA11 4" Flanged 7.31 23.88 4.19 4.50 9 4.5 3.75 0.75 ASOV-1 2012 Hauck Manufacturing Company Printed in U.S.A. 10/12

Hauck Manufacturing Company COMBUSTION CONTROL ACCESSORIES AUTOMATIC SHUT-OFF VALVES (ASOV) Automatic shut-off valves are necessary in combustion systems to provide reliable, positive shut off of fuels. The 8730 and 4730 series are suitable for various liquid fuels including No. 1 and No. 2 fuel oils, kerosene, preheated No. 4, No. 5 and No. 6 fuel oil. The 8730 series are normally closed valves. All valves are sanctioned for service by major approval agencies. The 8730 series is suitable for ambient temperatures from -20ºF to 125ºF (-28 to 52ºC). The 4730 series is suitable for ambient temperatures from -20 to 140ºF (-28 to 60ºC).Fluid temperature range is -20 to 250ºF (-28 to 121ºC). Each valve has a visual indication window and proof of closure switches. All valves are automatic reset and 115VAC/60Hz. Consult Hauck for applications not listed (e.g. fluid or ambient temperatures above the listed ratings or 50 Hz). NOTE: Top assembly enclosure meets approval standards NEMA 1, 2, 3, 3R, 4 and 12. Automatic Shut-off Valves Hauck Part No. Connection C v Maximum Inlet Gas Pressure Maximum Operating Pressure Differential 8730-05 60234 ½" NPT 3.4 300 psig 300 psid 8730-07 60023 ¾" NPT 9.6 300 psig 300 psid 4730-10 52285 1" NPT 12 300 psig 300 psid 4730-12 61499 1 ¼" NPT 17 300 psig 300 psid Model Closing Holding 4730 2.2 amp 0.2 amp 8730 1.5 amp 0.09 amp 115VAC/60Hz (OVER) ASOV-1.1 2009 Hauck Manufacturing Company Printed in U.S.A. 03/09

A UTOMATIC SHUT- O FF VALVES (ASOV) ½" and ¾" Valves B C D E G H 13.53 7.62 2.38 3.5 1.94 4.12 1" and 1¼" Valves ASOV-1.1 2001 Hauck Manufacturing Company Printed in U.S.A. 07/01

Hauck Manufacturing Company COMBUSTION CONTROL ACCESSORIES A UTOMATIC SHUT- O FF VALVES (ASOV) Automatic shut off valves are necessary in combustion systems to provide reliable, positive shut off of fuels. The V5055 series is suitable for various gaseous fuels including natural gas, vaporous propane and other clean industrial fuel gases. V5055 valves are normally closed. All valves are sanctioned for service by major approval agencies. The ASOV series is suitable for temperatures from -40 to 150 F (-40 to 66 C). Each valve has a visual indication window and proof of closure switch. All valves are 120VAC/60 Hz. NOTE: Top assembly enclosure meets approval standard NEMA 1. Automatic Shut-Off Valves Hauck Maximum Inlet Maximum Operating Connection Cv Part No. Gas Pressure Pressure Differential V5055-07 62921 ¾" NPT 14.6 75 psig 25 psid V5055-10 62922 1" NPT 21 75 psig 25 psid V5055-12 62923 1¼" NPT 28 75 psig 25 psid V5055-15 62924 1½" NPT 39 75 psig 25 psid V5055-20 62925 2" NPT 76 75 psig 25 psid Inrush Opening Holding 3.9 amp 2.94 amp 0.12 amp 120VAC/60Hz (OVER) ASOV-1.2 2001 Hauck Manufacturing Company Printed in U.S.A. 07/01

A UTOMATIC SHUT- O FF VALVES (ASOV) A B C D E F OCTAGON V5055-07 11.13 2.75 8.19 5.75 2.25 4.81 2.81 V5055-10 11.13 2.75 8.19 5.75 2.25 4.81 2.81 V5055-12 11.13 2.75 8.19 5.75 2.25 4.81 2.81 V5055-15 11.13 2.75 8.19 5.75 2.25 4.81 2.81 V5055-20 11.25 2.88 8.31 8.38 2.75 7.59 3.50 ASOV-1.2 2001 Hauck Manufacturing Company Printed in U.S.A. 07/01

Hauck Manufacturing Company COMBUSTION CONTROL ACCESSORIES A UTOMATIC SHUT- O FF VALVES (ASOV) Automatic shut off valves are necessary in combustion systems to provide reliable, positive shut off of fuels. The V710 series is suitable for various gaseous fuels including natural gas, vaporous propane and other clean industrial fuel gases. Also suitable for scrubbed and dried coke and sewer gases. V710 valves are normally closed. All valves are sanctioned for service by major approval agencies. The V710 series is suitable for temperatures from -40 to 150 F (-40 to 66 C). Each valve has a visual indication window and proof of closure switch. All valves are 120VAC/50-60 Hz. NOTE: Top assembly enclosure meets approval standards NEMA 1, 2, 3, 3R, 4 & 12. Automatic Shut-Off Valves Hauck Part Maximum Inlet Maximum Operating Connection Cv No. Gas Pressure Pressure Differential V710-07 61267 ¾" NPT 12 25 psig 15 psid V710-10 61128 1" NPT 17 25 psig 15 psid V710-12 62951 1¼" NPT 25 25 psig 15 psid V710-15 61245 1½" NPT 30 25 psig 15 psid V710-20 61208 2" NPT 64 25 psig 10 psid V710-25 62952 2½" NPT 75 25 psig 10 psid V710-30 62953 3" NPT 92 25 psig 10 psid V710-40 62954 4" Flanged 180 25 psig 15 psid Inrush Opening Holding 4730 2.2 amp 0.2 amp 120VAC/60Hz (OVER) ASOV-1.3 2001 Hauck Manufacturing Company Printed in U.S.A. 07/01

A UTOMATIC SHUT- O FF VALVES (ASOV) Actuator A B C D E V710-07 5.78 1.95 2.64 5.19 1.16 V710-10 5.78 1.95 2.64 5.19 1.16 V710-12 5.78 2.01 2.94 5.19 0.70 V710-15 5.78 2.01 2.94 5.19 0.70 V710-20 8.12 2.66 3.05 8.01 0.96 V710-25 9.00 2.96 3.87 8.01 0.70 V710-30 9.00 2.96 3.87 8.01 0.70 V710-40 13.88 5.00 7.40 9.00 0.00 ¾ - 3" 4" 2001 Hauck Manufacturing Company ASOV-1.3 Printed in U.S.A. 07/01