Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

Similar documents
Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

Effective March 2015 Supersedes S August 2012

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.

A 1.2 kv class externally removable secondary bushing

100 A externally operated one-, twoand three-phase tap-changer switch

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

Figure 1. Two and Three-phase MagneX.

Two-position sidewall (horizontal) and cover (vertical) mounted loadbreak switches

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

600 A 35 kv class BT-TAP deadbreak connector

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

600 A 15 kv class T-OP II deadbreak connector

INSTALLATION PRODUCTION TESTS

38 kv Bay-O-Net Cartridge and Fuse Assemblies Certified Test Report

1500 kva Padmount Transformer delta Primary Voltage 208Y/120 Secondary Voltage

600 A 25 kv class BT-TAP deadbreak connector

Tests are conducted in accordance with IEEE Standard 386. ac 60 Hz 1 Minute Withstand 50

PROTECTION AND CONTROL

X-Limiter full-range current-limiting fuse

OVERALL LENGTH (B) " ( mm) " ( mm) " ( mm) " ( mm)

Dry Well Cannister Type CLT, OIL Immersed PTAP-AFH926. Technical Guide Load-break, Dead-break

Loadbreak Apparatus Connectors. 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal GENERAL

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal

Loadbreak Apparatus Connectors

600 A 15 kv class Cleer loadbreak connector system

600 A 28 kv class Cleer loadbreak connector system

C. System Design and Performance Requirements

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

Product Selection Guide

MATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec ****

25 kv class fused loadbreak elbow connector

FEBRUARY 14, 2017 Elastimold Solid dielectric switchgear customer presentation

600 A 15 and 25 kv class deadbreak accessories, tools, and replacement parts

Underground Distribution Switchgear

Elastimold & Hi-Tech Fuse Products

K-Limiter high ampere Companion II fuse

copper stud. If a 900 A rating is desired, specify a C as the 8th digit when determining your part number (See Table 3, page 3.)

Distribution Transformers

High-voltage primary bushings installation instructions

600 A 35 kv class separable splices

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

Eaton s Cooper Power Systems

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

Three-phase pad-mounted compartmental type installation and maintenance instructions

Edison modular fuse, vault application products

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

25 kv Apparatus Bushings

MATERIAL SPECIFICATION ELECTRIC OPERATIONS ORGANIZATION. M3902 ****Supercedes BECo Standard E and ComElectric Spec ****

200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

600 A 35 kv class deadbreak accessories, tools, and replacement parts

NX indoor current-limiting fuses

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Figure 1. ELSG Current-Limiting fuses. TABLE 1 Maximum Interrupting Current (rms symmetrical) INSTALLATION

CATALOG. Hi-Tech Fuse Products

COOPER POWER SERIES. Three-phase pad-mounted compartmental type transformer installation and maintenance instructions

SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed.

200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition

15 kv and 25 kv Thru-Bushings

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Molded Current-Limiting Fuse

K-SEC 030. Fusing Equipment. Kearney Fuse Links GENERAL INTERNAL CONSTRUCTION SINGLE TIN ELEMENT

Distribution Transformers

Figure 1. Non-removable buttonhead Edison Links. TABLE 1 Edison Link Fuse Designs. System Fuse Ampere Rating Type Rating

1TSF /CD Attachment B. City and County of San Francisco Office of Contract Administration

200 A and 600 A, 15, 25, and 35 kv junction bars for separable connectors

High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

TECHNICAL SPECIFICATIONS OIL FILLED PADMOUNTED THREE PHASE WYE-WYE TRANSFORMERS

Protective Link Expulsion Fuse Type Prolink, Oil Immersed, PTAP-APR925 IZUA Technical Guide 15 kv, 23 kv, & 35 kv

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

Underground Distribution Switchgear

NEW Solutions for Underground System Growth

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit

Underground Distribution Switchgear

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Product Description: Objective and Certification: Test Samples and Test Cable:

15 kv Class Fused Loadbreak Elbow Connector with Interchangeable Fuse Capability

DISTRIBUTION TRANSFORMERS SPECIFICATION #

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open

Type MOST oil switch

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

INSTRUCTION MANUAL #103

Specifier's Guide COOPER POWER. Line installation and protective equipment master catalog 5 kv - 35 kv electrical distribution systems SERIES

Compact Integrated Distribution Substation (CIDS)

LG HRC Power Fuses ISO 9001 ISO 14001

GROUP D. Switch & Protective device.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Elastimold. Cable Accessories. Underground Distribution Switchgear. Molded Vacuum Switches and Fault Interrupters

Single-phase pad-mounted step voltage regulator

Figure 1. Single-phase pad-mounted voltage regulator. STANDARD FEATURES

SECTION PADMOUNT TRANSFORMER - OIL FILLED

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

"#$%&'(%)*#$ Installation, Operation, and Maintenance of Three-Phase Padmounted Distribution Transformers 45 kva through 10,000 kva

Single Phase Padmounted Transformers kva

Transcription:

Fusing Equipment Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly Electrical Apparatus 40-40 GENERAL Cooper Power Systems Bay-O-Net Fuse Assemblies are used to protect transformers and distribution systems. They are designed for use in padmounted or subsurface distribution transformers filled with Envirotemp FR3 fluid, transformer oil or approved equivalent. The assemblies combine the ease of hotstick operation with the safety of deadfront construction. The optional Flapper Bay-O-Net fuse assemblies (available as sidewallmounted only) include a flapper valve inside the housing which closes when the fuse holder is removed. (Refer to Figure 3.) This results in minimal oil spillage from the transformer tank which increases safety to line personnel during fuse changeouts, reduces potential of environmental concerns with oil spillage, reduces potential of oil contamination on the molded rubber elbow connections and reduces sensitivity to pad tilting. Silver-Plated Flapper Bay-O-Net assemblies are also available and recommended for use with the high ampere overload Bay-O-Net links. (See Catalog Section 40-49.) Silver-plated contacts along with the high ampere overload link allow the fusing of larger kva transformers. Removal of the fuse holder from the assembly indicates that the apparatus is electrically disconnected. It also allows convenient fuse element inspection and replacement. When typical safety practices are followed, the assemblies can be loadbreakoperated for working on the transformer secondary; changing distribution voltage with dual voltage switches or tap changers; or disconnecting the apparatus from the line. Current sensing (Section 40-4), dual sensing (Section 40-4), dual element (Section 40-48) and high ampere overload (Section 40-49) fuse links can be used in a Bay-O-Net fuse assembly. The assembly must be used in series with an isolation link (Section 40-47) or current-limiting fuse, such as the Cooper Power Systems ELSP (Section 40-0), to prevent the possibility of a 011 Supersedes 1110 Figure 1. Bay-O-Net Fuse Assembly for sidewall mounting with optional Flapper valve. high current fault close-in, even after the fuse link has been replaced. Partial range current-limiting fuses use the low current clearing capabilities of the Bay-O-Net fuse assembly while protecting from high current internal faults that could cause disruptive equipment failure or upstream system damage. INSTALLATION No special tools are required. The fuse assembly is mounted through the transformer tank wall for sidewall-mount and through the tank cover for covermount. The incoming high-voltage lead is connected to the isolation link or current-limiting fuse. The isolation link or current-limiting fuse is connected to the lower contact of the fuse assembly; and the upper contact is connected to the transformer winding. Refer to Service Information Section S40-40- for details. TABLE 1 Ratings and Characteristics kv Electrical Ratings 10 BIL and Full Wave Crest 0 0 Hz, ac, 1 minute withstand kv Maximum Single-Phase Interrupting Ratings in Mineral Oil* 3,00 A rms symmetrical 8.3 3,00 A rms symmetrical Sidewall Mount,00 A rms symmetrical 1.,00 A rms symmetrical Sidewall Mount** 1,000 A rms symmetrical 3.0 1,000 A rms symmetrical Sidewall Mount kv Loadbreak Ratings (at 80% pf) 10.0 10 A 1. 10 A.7 80 A 34. 0 A * With Cooper Power Systems Bay-O-Net fuse links only. Check Bay-O-Net fuse catalog sections for ratings in Envirotemp FR3 fluid. ** Except with high ampere overload Bay-O-Net links, which is 000 A rms symmetrical. 1

Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly FUSE CARTRIDGE High strength fuse cartridge directs and contains gases during fuse operation. Tapered end contacts allow easy insertion and removal during switching. OUTER TUBE Molded outer tube assembly of high temperature thermo-plastic withstands transformer operating temperatures and directs expulsion gases during fuse operation. FLAPPER VALVE (OPTIONAL)* Flapper valve is open when the inner fuse cartridge holder assembly is inserted. The valve closes when the fuse holder is removed resulting in minimal oil spillage. TAPERED FLANGE 7 tapered flange retains gasket seal when compressed during assembly. RUBBER SEAL Multiple groove Nitrile rubber seal ensures reliable sealing. HANDLE Stick-operable handle with cam action seals and unseals fuse holder assembly and allows easy removal of fuse. GASKET Gasket on inside of tank ensures reliable sealing. GAS PORTS Expulsion gas ports release gases during fuse operation to prevent excess pressure on fuse holder and break up gas bubbles to prevent restrike. END PLUG Threaded brass end plug makes contact with fuse link element and diverts gases during fault interruption. Figure. Cutaway Illustration of Sidewall-Mount Bay-O-Net Assembly with optional flapper valve. *Flapper valve is available on sidewall-mount assemblies only. GAS PORTS Expulsion gas ports release gases during fuse operation to prevent excess pressure on fuse holder and break up gas bubbles to prevent restrike. COPPER/SILVER-PLATED TERMINALS One-piece copper or silver-plated terminals provide convenient connections for high-voltage leads. CONTACT BUTTONS Independent spring copper or silver-plated contact buttons press evenly on fuse and are highly resistant to annealing for reliable electrical connection and high current carrying capacity. FLAPPER VALVE OUTER TUBE END PLUG FUSE CARTRIDGE A) CARTRIDGE REMOVAL WITH VALVE B) CARTRIDGE REMOVAL WITH VALVE C) CARTRIDGE REMOVED WITH IN OPEN POSITION PARTIALLY CLOSED FLAPPER VALVE CLOSED Figure 3. Flapper Valve operation during removal of fuse holder.

40-40 TANK COVER 3.0 (78 mm) Tank Wall 3 3. (9 mm) Gasket. (7 mm) B Recommended Oil Level Minimum Fluid Level 1.1 (9 mm) Lock Nut 7.0 (184 mm) Minimum Fluid Level A open Flapper Valve (optional)* 0.9 (17.3 mm) 3.1 (80 mm) 0.30 (8.13 mm) 0.70 (14.48 mm) 9.1 (3 mm) Figure 4. Cover-Mount Assembly shows dimensions for long and short assemblies and minimum fluid level. Figure. Sidewall-Mount Assembly shows installation configuration and fluid level. *Flapper valve is available on sidewall-mount assemblies only. Note: Dimensions given are for reference only. Flapper valve is NOT available on the covermount assembly. TABLE Assembly Dimensional Information Length in./(mm) Type A B Short Long 13. (34) 1.37 (41) 4.19 (107).94 (177) 3

Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly Ordering Information To order a Cooper Power Systems Flapper Bay-O-Net fuse assembly, refer to Tables 3 and 4. See Table for ordering Silver Plated Flapper Bay-O- Net Assembly. TABLE 3 Fuse Assemblies Description Flapper Sidewall-Mount Sidewall-Mount w/o Flapper valve Cover-Mount (short) Cover-Mount (long) Catalog Number 400031C99FV 400031C99MC 4001177B1MC 4001177B3MC Table 4 Replacement Parts Description Catalog Number Figure Number Item No. Flapper Sidewall-Mount Outer Tube, with 403718C03M Contacts, Gasket and Nut 1, and 3 Tank Wall Gasket 037980C19 Lock Nut 40380A01 3 Housing with Inner 4038804B0M Holder Only (no cartridge) and 7 1,, 3, and 4 Inner Fuse Cartridge 4001030BM Holder Assembly, with Fuse Cartridge and End 4,, and Inner Holder Only 400071B0M 7 4 40018A3M and Fuse Cartridge 34379B0M End 40018A01 Sidewall-Mount w/o Flapper Valve Outer Tube, with 403718C01M 1,, Contacts, Gasket and Nut and 3 Tank Wall Gasket 037980C19 Lock Nut 40380A01 3 Housing with Inner Holder Only (no cartridge) Inner Fuse Cartridge Holder Assembly, with Fuse Cartridge and End 4038804B01M 4001030BM and 7 1,, 3, and 4 4,, and Inner Holder Only 400071B0M 7 4 40018A3M and Fuse Cartridge 34379B0M End 40018A01 Cover-Mount w/o Flapper Valve Tank Wall Gasket 00117A11 10 Lock Nut 080398A01 9 8 Sealing Cap Gasket 00119A01 8 Sealing Cap 40079A01 7 Short Inner Holder 400144B4 Assembly, with Fuse Cartridge and End 1,, and Short Inner Holder Only 4001180B01 1 Long Inner Holder 400144B Assembly, with Fuse Cartridge and End 9 and Long Inner Holder Only 4001180B0 1 40018A3M and Fuse Cartridge 34379B0M End 40018A01 Figure. Sidewall-Mount Outer Tube with contacts and gasket. Figure 7. Sidewall-Mount Inner Fuse Cartridge Holder Assembly with fuse cartridge and end plug. Figure 8. Cover-Mount Outer Tube with contacts and gasket. 11 Figure 9. Cover-Mount Inner Holder Assembly with fuse cartridge and end plug. 1 1 4 10 9 3 8 7 4

40-40 Ordering Information Table Silver Plated Bay-O-Net Assembly Parts* Description **Silver Plated Bay-O-Net with inner fuse holder. (Figure 10) ***Silver Plated Bay-O-Net with inner holder, fuse cartridge and end plug. (Figure 11) Inner holder with silver plated fuse cartridge and end plug. (Figure 1) Silver Plated Bay-O-Net not including inner holder fuse cartridge and end plug. (Figure 13) Silver plated fuse cartridge including end plug. (Figure 14) Silver plated fuse cartridge without end plug. (Figure 1) Catalog Number 4038804B03M 400031C89FV 4001030B9 403718C0M 40018A4M 34379B03M * This is the recommended holder for use with High Ampere Overload Links (Section 40-49). These integral cartridge fuse links have been designed for high kva transformer applications. ** Should be specified when using integral cartridge fuse links 400038C1CB, 400038C18CB, 403831C03CB, 403831C04CB, and 403831C0CB. It should also be specified along with solid link 403831C10CB. *** Should be used for all fuse links except the integral cartridge links 400038C1CB, 400038C18CB, 403831C03CB, 403831C04CB, 403831C0CB and solid link 403831C10CB. Figure 10. Silver Plated Bay-O-Net with inner fuse holder, Catalog No. 4038804B03M. Figure 11. Silver Plated Bay-O-Net with inner fuse holder, fuse cartridge and end plug, Catalog No. 400031C89FV. Figure 1. Inner holder with silver plated fuse cartridge and end plug, Catalog No. 4001030B9. Figure 13. Silver Plated Bay-O-Net not including inner holder fuse cartridge and end plug, Catalog No. 403718C0M. Figure 14. Silver plated fuse cartridge including end plug, Catalog No. 40018A4M. Figure 1. Silver plated fuse cartridge without end plug, Catalog No. 34379B03M.