A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

Similar documents
CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed.

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115

SECTION PADMOUNT TRANSFORMER - OIL FILLED

MATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec ****

MATERIAL SPECIFICATION ELECTRIC OPERATIONS ORGANIZATION. M3902 ****Supercedes BECo Standard E and ComElectric Spec ****

DISTRIBUTION TRANSFORMERS SPECIFICATION #

C. System Design and Performance Requirements

Underground Distribution Switchgear

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17

SPECIFICATION FOR THREE PHASE PAD-MOUNT DISTRIBUTION TRANSFORMERS

Single-Phase Step Voltage Regulator

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Distribution Transformers

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

Technical Specification for Pole Mounted Capacitor Rack

1TSF /CD Attachment B. City and County of San Francisco Office of Contract Administration

Underground Distribution Switchgear

Distribution Transformers

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

Three-Phase Pole Mounted Recloser

Medium Voltage Metal-Enclosed Switches

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor

Typical Specification

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

35-kV Safefront 200 Amp SuperWell Primary Capacitor Station Pad-Mounted Outdoor

Drive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer

Technical Specification For Outdoor Substation Harmonic Filter Banks

34-SDMS-02 SPECIFICATIONS FOR

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

15-kV Safefront 200 Amp Primary Capacitor Station Pad-Mounted Outdoor

500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled

Fixed, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE_107_R1

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

Single Phase Padmounted Transformers kva

Effective March 2015 Supersedes S August 2012

Automatic, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

38 kv Bay-O-Net Cartridge and Fuse Assemblies Certified Test Report

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

SECTION PANELBOARDS

Single-phase pad-mounted step voltage regulator

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B

Figure 1. Two and Three-phase MagneX.

34-SDMS-01 SPECIFICATIONS FOR

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit

Underground Distribution Switchgear

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

CITY OF MARYVILLE ELECRIC DEPARTMENT Maryville, Tennessee SPECIFICATIONS FOR 15KV POWER CIRCUIT BREAKERS. September 2018

Power IT Liquid Filled Single Phase Padmounted Transformers kva

TECHNICAL SPECIFICATIONS OIL FILLED PADMOUNTED THREE PHASE WYE-WYE TRANSFORMERS

35-kV Safefront 200 Amp Primary Metering Station Pad-Mounted Outdoor

35-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current-Limiting Fuses

Medium Voltage Metal-Enclosed Switches

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

100 / 110 DRYWELL FUSE SPECIFICATION

NEW Solutions for Underground System Growth

SECTION MOTOR REQUIREMENTS for HVAC

Padmount. Small Power Transformers 2500 kva Through 20,000 kva 5 kv Through 46 kv Primary Voltage 120V Through 25 kv Secondary Voltage

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

BUSWAY Low Voltage (Pow-R-Flex)

10 Commercial, Industrial, Agricultural Services

SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES

Figure 1. Single-phase pad-mounted voltage regulator. STANDARD FEATURES

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

A. Submit manufacturer's literature and technical data before starting work.

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open

C1000 Series Automatic Cap Bank

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

University of Houston Master Construction Specifications Insert Project Name

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

STANDARD SPECIFICATION FOR TYPE PLD LIVE-FRONT/DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV A. General

15-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 140 Amp (Max) Clip-Mounted Current-Limiting Fuses

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6

Detail Bill of Material Page 1 of 1 Project Name: Amphi School - MVS Replacement Negotiation No: TU700213X7K2 General Order

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

Features, Benefits and Functions

SWITCHGEAR DIVISION PRODUCT PROFILES

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

STANDARD SPECIFICATION FOR PAD-MOUNTED CAPACITOR BANKS FOR 15kV or 25kV APPLICATIONS

Product Specifications for Phase Over Phase GOABS(r)

Outdoor Power Transmission & Distribution

S&C Manual PME Pad-Mounted Gear

Unit Substation Transformers 5 and 15 KV Class

Elastimold. Cable Accessories. Underground Distribution Switchgear. Molded Vacuum Switches and Fault Interrupters

DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV

Transcription:

1. APPLICATION A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 2. REFERENCE STANDARDS A. The transformers supplied shall be manufactured and tested according to the latest editions, revisions, and amendments to IEEE C57.12.26, Department of Energy 10 CFR Part 431, and all other applicable standards of NEMA, ANSI, and IEEE, except as modified herein. 3. PRODUCTS A. Voltage Ratings 1) The high voltage rating shall be 12470 Grounded Y/7200 volts. 2) The low voltage rating shall be one of the following: a) 208Y/120 volts b) 480Y/277 volts B. kva Rating. EWEB standard ratings are 75, 112.5, 150, 225, 300, 500, 750, 1000, 1500, 2000 and 2500 KVA. This rating is based on not exceeding either a 65 C average winding temperature rise or an 80 C hot-spot conductor temperature rise above 30 C ambient temperature. C. BIL Rating. All transformers shall have at least a 95 kv BIL on the high voltage side and 30 kv BIL on the low voltage side. ENGINEERING REVIEW STANDARDS COMMITTEE APPROVAL Page 1 of 8

D. Construction: Shall conform to items in IEEE C7.12.26 and the requirements listed below. 1) Enclosure a) The transformer shall be weather and tamper resistant b) Drip shield shall be provided c) Each compartment door shall be tamper resistant in accordance with the latest ANSI and IEEE standards and hinged with stainless steel pins that cannot be removed when the compartment doors are closed. The doors shall have a latch or hasp that will allow for locking the cover(s) with a padlock. Minimum one captive and recessed pentahead bolt shall be provided for additional security of the compartment door. d) For transformers 500 kva and greater, do not provide lifting handles on the inside surface of compartment doors. e) The tank finish shall be resistant to chipping and shall be powder coated with a high corrosion resistant material. The color shall be Munsel 7GY 3.29/1.5 Bell Green or equal. f) The tank shall be equipped with a removable inspection plate which will allow access to the primary and secondary compartment. 2) High Voltage Terminals a) Provide either three (3) high voltage bushing wells for radial primary cable feed or six (6) high voltage bushing wells for loop primary cable feed as required on the request for quotation or purchase order. b) Provide primary bushing wells secured with studs or bolts on the outside of the transformer tank. No welded or internally fastened bushing wells shall be accepted. c) Provide factory installed 200 ampere load break bushing well inserts in all bushing wells, Elastimold catalog # 1601A4, or equal. Bushing inserts shall be covered with dust caps prior to shipment. 3) Low Voltage Terminals Page 2 of 9

a) Staggered arrangement of four-hole or six-hole NEMA pad. See Figures 4(a) and 9 of IEEE C57.12.26. b) No tank-welded bushings. Bushings shall be bolted or stud-connected to the tank only. c) For transformers 500 kva and greater provide low voltage terminal supports rated for 500 lbs. per terminal and insulated for 10 kv per IEEE C57.12.00 Table 8. 4) Grounding a) Exposed surfaces of the primary terminals shall be grounded. b) High voltage compartment. Provide a fitting for grounding the concentric neutral strands. c) Provide grounding pads per IEEE C57.12-26. In one tapped hole of each pad provide a bronze vise-type grounding stud with stainless steel hardware, Hubbell Power Systems GC 207 or approved equal. 5) Arresters. Not required. 6) Dimensions. The height of transformer shall not exceed the following: 75 kva thru 500 kva height 63 750kVA thru 2500 kva height 77 7) Core-Coil Assembly. The transformer core and coil assembly shall be either five legged or triplex construction. E. Accessory Equipment 1) High Voltage Tap Changer a) Transformers shall be provided with taps of +/- 5 percent in four, 2 ½ percent steps. b) The tap changer handle shall be mounted in the high voltage compartment and be operable from outside the transformer tank. 2) High Voltage Overload Device: Oil cutout, Bay-O-Net, type fusing shall be provided. These overcurrent devices shall be capable of interrupting not less than 3500 AMPS asymmetrical fault current up to 8.3 kv. Page 3 of 9

a) Provide Cooper Power Systems isolation link with the Bay-Net oil fuse cutouts as specified below, or equal. b) For transformers rated 1500 KVA or smaller, provide Cooper Power Systems dual sensing link for protection of the transformer against excessive overload, secondary faults and for the protection of the system against transformer fault as specified below, or equal. c) Transformers larger than 1500 KVA shall be protected by high current Cooper Power Systems Bay-O-Net links with appropriate isolation link as specified below, or equal along with silver-plated Flapper Bay- O-Net assembly. KVA 358C Series Dual Sensing Fuse Link Isolation Link 75 C05 A02 112.5 C08 A03 150 C08 A03 225 C10 A05 300 C10 A05 500 C12 A06 750 C14 A07 1000 C14 A07 1500 C18 A07 High Current Fuse Link Cooper 4038361-2000 C05CB A06 2500 C05CB A06 3) High Voltage Switch. The high voltage switch shall be an oil-immersed gang operated four-position loadbreak switch, or two two- position loadbreak switches. This arrangement shall allow for connection to either one or the other or both high voltage sources or to neither (off). The switch or switches shall be operable with a hot line tool, shall be plainly visible and permanently marked and have the following minimum ratings: a) 15 kv line-to-line b) 95 kv BIL Page 4 of 9

F. Oil 4. TESTS c) 200 amperes RMS, continuous d) 200 amperes RMS, interrupting at up to a 60% lagging power factor e) 12,000 amperes asymmetrical momentary (30 cycles) make and latch 4) Pressure Relief. A pressure relief device that automatically opens at 8-10 PSIG and automatically reseats at a positive pressure of between 2 and 8 PSIG shall be provided on all units. 5) Accessory Equipment Location. All high-voltage accessories shall be located in the high-voltage compartment and all low voltage accessories shall be located in the low voltage compartment. 6) Oil Drain and Fill. In one of the compartments, all sizes of transformers shall have a one-half inch NPT upper filter press and filling plug, and a lower drain valve with built-in sampling device. 7) Oil Level Gauge. Provide an oil level gauge in the secondary compartment. 8) The manufacturer or supplier shall not install informational warning signs on the equipment furnished under this material specification. EWEB has a policy to install their own custom warning signs on all equipment. These signs will meet NEMA requirements. 1) Dielectric fluid shall be natural ester-based that meets the minimum acceptance testing requirements described in the latest edition of IEEE C57.147 Guide for Acceptance and Maintenance of Natural Ester Fluids in Transformers. New transformers provided with natural ester-based fluid shall meet the National Electrical Code requirements for less-flammable liquid-insulated transformers. Fluid shall be Cargill Envirotemp FR3, or equal. 2) Provide a label indicating the transformer is filled with natural ester-based fluid. 3) The nameplate shall be stamped certified NO DETECTABLE PCB. LESS THAN ONE PART PER MILLION PCB. The manufacturer shall provide non PCB certification. Page 5 of 9

A. Factory Tests: In addition to the ANSI and IEEE specified tests, each unit shall successfully pass the following tests: 1) No load and Load Losses Tests: Each individual transformer manufactured shall be tested for No Load (core) losses at 100% rated voltage, and for load (copper) losses at 85 C and full load current. These tests shall be conducted at the nominal tap setting. 2) Full wave impulse test on high-voltage terminals at 95 kv, as specified in IEEE C57.12.90. 3) Suitable test to verify sealed tank construction. 4) Certification that each unit was subjected to and successfully passed all tests as specified shall be forwarded via SMTP email, to EWEB Transformer Department not later than transformer shipment. 5) A durable test tag, sticker or stamp, shall be attached to each transformer; stating that the transformer, after final assembly, has been tested and is suitable for normal use at rated voltage. B. EWEB Acceptance Tests 5. WARRANTY 1) Upon receipt, all transformers will be inspected for leaks, breakage, or damage, and checked for adherence to EWEB s material specification. All transformers will be turns-ratio-tested and meggered. Transformers failing these tests will be rejected and returned at the supplier s expense. 2) EWEB will complete inspections and testing within five (5) business days after delivery of transformers. Transformers will be accepted after they pass inspections and tests. 3) If EWEB finds goods furnished to be incomplete or not in compliance with the Contract, EWEB, at its sole discretion, may either reject the goods, require Vendor to sell the goods to EWEB at a reduced price, whichever EWEB deems equitable under the circumstances. A. Provide a warranty period of eighteen (18) months minimum after the date of acceptance. Page 6 of 9

B. Unless otherwise stated, all equipment shall be free and clear of any lien or encumbrances and shall be new and the current model and shall carry full manufacturer warranties. C. Vendor warrants to EWEB that any transformers furnished will operate and function in the manner represented by Vendor and will achieve the performance stated in the material specification when operating within the design conditions described therein. D. Vendor warrants the transformers furnished are free from defects in material and workmanship, and agrees to repair or replace any unit that is unsuitable for operating or fails in operation during normal and proper use, including all parts and labor at no cost to EWEB. 6. PACKAGING AND DELIVERY A. EWEB's Transformer Shop shall be notified a minimum of two working days (48 hours) before delivery day. The successful bidder will be given the name and phone number of the Transformer Shop contact person at the time of the award of the contract. B. Delivery hours are 9:00 a.m. until 2:00 p.m., Monday through Friday. C. All transformers shall be secured to a hardwood pallet rated to support its weight. D. Transformers shall be covered during transit to protect them from dirt and grime, either by covered van or tarped open flatbed truck. Transformers shipped in enclosed vans shall not exceed 4,500 lbs. each. E. Transformers that are delivered in trucks that do not meet the Packing and Delivery Instructions above may be assessed damages and supplier shall be required to correct damage. A minimum charge of $50 per transformer may be assessed for each transformer delivered improperly 7. SUBMITTALS A. Submit the information required in Exhibit A. 8. EWEB STORES INFORMATION A. This material specification shall be used to purchase the material with the following stock codes. Page 7 of 9

496-0001935 through 496-0001936 496-0001938 through 496-0001942 496-0001944 through 496-0001959 496-0001961 through 496-0001962 Page 8 of 9

EXHIBIT A SPECIFIC INFORMATION REQUIRED WITH BID THREE PHASE PAD MOUNTED TRANSFORMERS (Submit Separate Sheets for Each Item) Manufacturer: KVA High voltage Low voltage 1. No load losses at 100% rated voltage (Core losses) 2. Load losses at 85 C and full-load current (Copper losses) watts watts 3. Number of Primary Bushings 4. Impedance % 5. Quantity of oil per transformer gal. 6. Total weight with oil lbs. 7. Limiting overall dimensions: Height Width Depth Cable Entry Length Cable Entry Width 8. Type of tank material and thickness 9. Type of finish 10. Tap changer voltage steps % Page 9 of 9