DATASHEET 16 Mar 2016

Similar documents
VDC CAA - CAP168/CAP437

DATASHEET. 25cd Low-intensity Obstruction Light - 230VAC. CEL-LI F - LED Aircraft Warning Light

WLTwin77 Twin Aviation Obstruction Light. Data Sheet. Rev: 1.1

Optical Signal Devices

Model Specifications Code Price FOTOSWITCH

WL-100 High Intensity Aviation Obstruction Light

SafeSite LED Based Signaling for Hazardous Locations


CX-SERIES ADVANCED BATTERY CHARGER

A-L810 Steady-Burning Red LED Obstruction Light Installation and Maintenance Manual

Pressure switch hex 27

TY / TY User Manual

SafeSite LED Based Signaling for Hazardous Locations

LT864 Medium Intensity Solar Aviation Obstruction Light

Application Engineering Europe

Hydraulic power unit CE8L Technical data

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

LED CANOPY with j-box

General Purpose Relay

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

CX Series User s Manual

PAPI PU3L AIRFIELD LIGHTING. Precision Approach Path Indicator. PAPI or APAPI. Visual Precision Approach Path Indicator Systems. Location on the Field

NICE WIDE THE BARRIER GATE OPERATOR SYSTEM EASY TO INSTALL, SAFE TO USE AND SIMPLE TO MANAGE.

Wind Energy System.

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

Power Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Sentry FR Series Marine Battery Chargers

400W / 600W / 1000W / 1500W DIY Wind Turbine

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Emergency lighting units EM powerled

TNA-AS-50 OMNI-DIRECTIONAL BATTERY POWERED PORTABLE AIRFIELD LIGHT (PAL) AND TACTICAL MARKER

Emergency lighting units EM LED Light Engines

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Floodlight LED Series 6525

INDUSTRIAL OL - SERIES SOLAR LED INDUSTRIAL

Scheda prodotto Relè Series E

Bearing temperature sensor Type MBT 5310

Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

Page 1/6. Temperature sensor baelz 61 with questionnaire for inquiries on page 5 DS 61, 251

Solar inverter AX-series

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

Electronic Temperature Sensor ETS 300

Technical specifications

Floodlight LED Series 6125

Exhaust gas temperature sensors MBT 5113 and MBT 5116

Power Supply EL

ETTES POWER MACHINERY CO., LTD. Technical Datas and Prices of 300W Wind Turbine

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Sail Away with Peace of Mind. Dolphin Series II Smart Battery Chargers

Safe lithium ion high energy batteries. for electric propulsion. Chargers, on board supply EN LiFePO4

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

LED Adjustable Cutoff Wallpack

INSTRUCTION MANUAL (ATEX / IECEx)

INDUSTRIAL POWER SUPPLIES SFL-SERIES

TRAFFI BARRIE COST EFFECTIVE BARRIER SOLUTIONS TRAFFIC BARRIERS

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Miniature Intermediate Power Relay HY

ILED Dorado. User Manual

Industrial Relay KML(1C, 2C)

Emergency lighting units EM powerled

DIGITAL NET. MULTI-BEAM OPTICAL BARRIER OPTICAL OR BY WIRE SYNCHRONISM COMPLETE DIGITAL CONTROL with AGC 10 1 METRE 2 STRAIGHT OR 4 CROSSED BEAMS

PY, SPY; FSQC, FP; EPC; AP

SolarMax S series (Australia) Maximising solar plant yields can be so easy.

Electronic Flow Monitor for liquids

Airfield Lighting. Omnidirectional SafeLED Elevated Light (SL-TE-E, SL-TH-E) Product Description. Taxiway Edge Intermediate Holding Position

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

MANBLAN Hybrid Powered Landscape Lights SL C-00-5 <Assembly Type>

Electronic Pressure Switches

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Position switches FR series

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

INSTRUCTION SHEET PRL-97X04 AC AND DC VOLTAGES

Features. Description. Table of Contents

Lighting for Aviation

Example: L80B10 > h means that not more than 10% of the luminaires fall below 80% of the luminous flux after h.

WORKING SAFELY WITH ELECTRICITY Wall-mounted distributors

Runway Guard Lights RGL 921 USER MANUAL GB

Liquid cooled heavy duty converter

Position switches FR series

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

D-FORCE1500PV GARAGE DOOR OPENER

NV Direct Coupled Globe Valve Actuator

Solar Inverter Manual

Low Frequency Inverter. User Manual

PRODUCTS: POWER SUPPLY

EXEL-L. Detail of the internal side. Transparent polycarbonate

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Manual for Inverter system type PCI05

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

ELECTRICAL PANELS. Chap.

Transcription:

DATASHEET 16 Mar 2016 CEL low-intensity stand-alone series is designed for marking tall structures such as wind turbines, chimneys, masts, and towers. The product offers unique features such as fault monitoring, photocell and switcher incorporated in the light. Key Features - Based on LED technology - 200cd red fixed and flashing light - Incorporated photocell and fault monitoring - Extremely low power consumption - More than 10 years of maintenance free operating time - 5 year warranty - the longest in the industry - 10 year warranty for the optics Optical characteristics - 200cd fixed or flashing - Colour aviation red - Horizontal beam 360 - Vertical beam >200cd +5 +8 >50cd 0 +15 Specifications met - CAP 168 CAP 437 Civil Aviation Authority, London, UK February 2001, Flight obstacle (low intensity) Electrical Characteristics - ACW- models, wide AC voltage range: Nominal 115...240V AC, Nominal 50... 60Hz - DCW- models, wide DC voltage range: Nominal 10...60V DC - Overvoltage protection - Constant power input by active PFC - Day/Night switch (400/ 800/ 1600 lux) - Flash rates: 20/ 40/ 60fpm - Power consumption 12W Mounting Set Options - CEL-MS-HV80 - CEL-MS-EV60 - CEL-MS-EV100 - CEL-MS-EV150 - CEL-MS-DEV60 - CEL-MS-DEV100 - CEL-MS-RW - CEL-MS-LVU - CEL-MS-N1B Low-Intensity 200cd Stand-alone Series LED Aviation Obstruction Lights T: +44 (0)20 8540 1034 F: +44 (0)20 8543 3058 E: info@contarnex.com Contarnex Europe Limited 252 Martin Way, Morden, Surrey SM4 4AW United Kingdom Page 1 of 6 www.contarnex.com

Page 2 of 6 Mechanical Characteristics - Andoised, marine grade aluminium body and end parts - AISI 316 acid-proof stainless steel screws - Glass cover, degree of protection IP65 - Operating temperature range -40...+55 C - Height 255mm, diameter 104mm - Weight 1,3kg (without mounting set) - Terminal block for 1.5... 4mm2 wires Order code ICAO / FAA Output Op. volt. Power cons. Fault monitoring Built-in photocell Packing dimensions CEL-LI-200-DCW-A 200cd 10-60VDC 10W Yes Yes 280x130x100, 1,5kg CEL-LI-200-ACW-A 200cd 115-240VAC 12VA Yes Yes 280x130x100, 1,5kg Mounting sets CEL-MS-HV80 CEL-MS-EV60 CEL-MS-EV100 CEL-MS-EV150 CEL-MS-DEV60 CEL-MS-DEV100 CEL-MS-RW CEL-MS-LVU CEL-MS-N1B Mounting set, basic model for 33 to 80 mm pipes Mounting set with extension plate for 30 to 60 mm pipes Mounting set with extension plate for 60 to 100 mm pipes Mounting set with extension plate for 100 to 150 mm pipes Mounting set for double lights with extension plate for 30 to 60 mm pipes Mounting set for double lights with extension plate for 60 to 100 mm pipes Mounting set with extension plate for roof or wall mounting Mounting set with extension plate for L, V, and U-profiles, galvanized Mounting set with 1" NPT at bottom

Page 3 of 6

Page 4 of 6 Electrical installation instructions CEL LI SAL Series have two cable glands for easy chaining without external distribution boxes. Connection can be protected with a 6A or 10A fuse or with a circuit breaker (C curve: C6A or C10A). Configuring CEL LI SAL Series Photocell mode (enabled/disabled) and threshold (400 lux, 800 lux or 1600 lux) can be selected by the user using DIP configuration switches. Open three screws on the bottom of CEL light to gain access to DIP switches. We recommend using a socket wrench but the screws can also be opened with a suitable flat-head screwdriver. Holding the aviation obstacle light glass dome pointing upwards, the individual DIP switches are numbered 1-4 from left to right. Installation specifications - Cable gland M25 - Cable diameter 11 to 17mm - Wire diameter max. 6mm2 - Recommended cable - 3x1.5 mm2 or 3x2.5mm2 Options - CGS-20 Smaller cable glands - Set includes 2 pcs M20 cable glands with M25-M20 adapters for 7-13mm cables Factory default setting is all switches in OFF (steady-burning mode without photocell control). Turn-off time in 3 min, turnon time is 10 sec. When the photocell operation is enabled, the obstruction light turns on when the ambient light level has dropped below selected level for ten seconds. Light turns off when the ambient light level has exceeded the selected value for more than three minutes 1. Bottom plate screws 3. Block diagram of CEL LI stand-alone light DIP Switch Settings Photocell mode 1 2 Operating mode OFF OFF Photocell disabled ON OFF 400 lx OFF ON 800 lx ON ON 1600 lx DIP Switch Settings Flash mode 3 4 Operating mode OFF OFF Steady-burning i.e.fixed ON OFF 20 flashes per minute OFF ON 40 flashes per minute ON ON 60 flashes per minute 2. Location of DIP switches

Page 5 of 6 CEL-MS-HV8O Mounting set for 33-80mm vertical or horizontal pipe - 2 pcs M6 U-bolt - 8 pcs M6 hex nut - 4 pcs 6/12 mm washer All parts AISI 316 acid-proof stainless steel More detailed mechanical data: see CEL-MS-HV80 datasheet Order Code: CEL-MS-HV80 CEL-MS-EV60 Mounting set with extension plate for 30-60mm vertical pipe installation Extension plate marine grade anodised aluminium, other parts AISI 316 acid-proof stainless steel. More detailed mechanical data: see CEL-MS-EV60 datasheet Order Code: CEL-MS-EV60 CEL-MS-EV100: Mounting set with extension plate for 60-100mm vertical pipe installation Extension plate marine grade anodised aluminium, other parts AISI 316 acid proof steel More detailed mechanical data: see CEL-MS-EV100 datasheet Order Code: CEL-MS-EV100 CEL-MS-EV150: Mounting set with extension plate for 100-150mm vertical pipe installation Extension plate hot dipped galvanised steel, other parts AISI 316 acid-proof stainless steel More detailed mechanical data: see CEL-MS-EV150 datasheet Order Code: CEL-MS-EV150

Page 6 of 6 CEL-MS-DEV60: Double mounting set with extension plate for 30-60mm vertical pipe installation. Mounting set includes: - 8 pcs M6x30 bolt, 16 pcs M6 hex nut, 8 pcs 6/12 washer Extension marine grade anodised aluminium, other parts AISI 316 acid-proof stainless steel More detailed mechanical data: see CEL-MS-DEV60 datasheet Order Code: CEL-MS-DEV60 CEL-MS-DEV100: Double mounting set with extension plate for 60-100mm vertical pipe installation. Mounting set includes: - 8 pcs M6x30 bolt, 16 pcs M6 hex nut, 8 pcs 6/12 washer Extension marine grade anodised aluminium, other parts AISI 316 acid-proof stainless steel More detailed mechanical data: see CEL-MS-DEV1 00 data sheet Order Code: CEL-MS-DEV100 CEL-MS-RW Mounting set for horizontal plate or wall installation Mounting set includes: - 1 pcs L -shape 2 mm plate All parts AISI 316 acid-proof stainless steel More detailed mechanical data: see CEL-MS-RW datasheet Order Code: CEL-MS-RW CEL-MS-LVU Mounting set for L and V -shape profiles Mounting set includes - 1 set accessories for light unit fitting to plate with adjusting plate and accessories Extension plate hot dip galvanised steel, other parts AISI 316 acid-proof stainsteel More detailed mechanical data: see CEL-MS-LVU datasheets Order Code: CEL-MS-LVU (with galvanized extension plate) CEL-MS-LVA (with AISI 316 extension plate) CEL-MS-N1B Mounting set for 1 NPT at bottom More detailed mechanical dimensions: see CEL-MS-N1 B dataheet Order Code: CEL-MS-N1 B