Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

Similar documents
Universal Retrofit System Installation Instructions Revised:

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation


LED 2/3/4ft T8 Tube 120V

Instruction/Installation Manual

LED IMPORTANT SAFETY INSTRUCTIONS

Lumination TM LED Luminaire LUR Series

TECTONIC LED CORP. ISO

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

CFP-LED Contractor Select Flat Panel. Installation Instructions

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

Product Installation Instruction LED Tube Lamp Retrofit Kits

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ModuSys LED Retrofit Kit 2x2, rev. D.02

STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

General Installation Instructions LED

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Installation Instructions BLTR and 2BLTR Relight Assembly

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

SURE-LITES FBP140XLP Instruction Manual

LED IMPORTANT SAFETY INSTRUCTIONS

LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

IMPORTANT SAFETY INSTRUCTIONS

Assembly Instructions Retrofitting

LED Recessed Troffer Retrofit Kit

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTALLATION INSTRUCTIONS 120V DirectAC LED Engine Kit

MAXLITE RKT LED Retrofit Kit

Optimax Pro Retrofit Instructions

SAVE THESE INSTRUCTIONS

LUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

Solid State T8 tube is the smart alternative to a

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

Installation Instructions: Eco-Fit T8 LED Tube Lamp

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

LED IMPORTANT SAFETY INSTRUCTIONS

T8 Tube Light. UL LISTED & cul LISTED & DLC LISTED. Germany Patent: Gebrauchsmusters / Nr

Installation and Operation Instructions 10/04/13

INSTALLATION INSTRUCTIONS

General Installation Instructions LED

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

Installation Instructions: Eco Linear High Bay

PDX and PX Retrofit Series

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

Motion and Light Sensor Kit LHBAS51

FLUORESCENT EMERGENCY BALLAST Lumens. When using this lighting device safety precautions should be followed at all times

LM79 LM80 L70:5+ YEARS

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

RECESSED TRACK (120V) SPECIFICATIONS

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

UL AND CODE COMPLIANCE

MaxLite LED Linear HighBay Fixtures

Installation Instructions: HYPERION R-Lite SYSTEM

SAVE THESE INSTRUCTIONS

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

LED IMPORTANT SAFETY INSTRUCTIONS

LED. High-performance streetlight. -afortable and reliable

Installation Instructions: ACCENT SYSTEM

MaxLite LED UTILITY WRAP FIXTURES

INSTALLATION INSTRUCTIONS STEP-DOWN TRANSFORMER HOUSING KIT

BUYERS GUIDE FOR TYPE C DRIVERS. Programmable vs. Field Adjustable LED Drivers

Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

Wireless Dimmer Installation and User Guide

HIGHBAY RAIL 400W INSTALLATION INSTRUCTIONS

Installation Instruction ALG Series LED Area Light Version: 3.1

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

Installation Instructions Central Battery Units

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032

Stik Families GENERAL PURPOSE RETROFIT SIGN CONVERSION FOR USE ONLY IN ACCORDANCE WITH KIT INSTRUCTIONS

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

PIL0478 ISSUE 01/ 07/16

Installation Instructions

SAVE THESE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

A-Series II Panelboards AD/AE/AQ Type P & N Panel THQB Three-Phase Circuit Breaker Kits

EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES

Transcription:

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised: 20180126 These instructions do not purport to cover all details or variations in components nor to provide for every possible contingency to be met in connection with installation, operation, or maintenance. Should further information be desired or should a particular problem arise which is not covered sufficiently for the purchaser s purpose, the matter should be referred to Linmore LED Labs. Linmore does not claim liability for any installation not performed according to this guide or not by a qualified electrician. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION 2. WARNING Risk of fire or electric shock. LED Upgrade Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Product must be installed in accordance with NEC or your local electrical code. If you are not familiar with these codes and requirements, contact a qualified electrician. 3. WARNING Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of the LED upgrade kit. Check for enclosed wiring and components. 4. WARNING Risk of fire or electric shock. Check the existing wiring for damage before installing upgrade kit. Do not install if existing wires are damaged. 5. WARNING To prevent wiring damage or abrasion, do not expose wires to the edge of sheet metal or any other sharp objects. 6. WARNING Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings. 7. The retrofit assembly is accepted as a component of a luminaire where the suitability of the combination shall be determined by UL or authorities having jurisdiction. 8. Only the holes indicated in the photographs or drawings may be made or altered as a result of the kit installation. Do not leave any other holes open in a wiring enclosure or electrical component.

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE NOTES: 1. Upgrade Kit is for installation in a common 4 or 8 dry or damp location fluorescent strip fixture. The luminaire shall have the following minimum dimensions: 2 deep pan 3 wide minimum wiring compartment 46 minimum length to accommodate 4 nominal length light bar and 22 minimum length to accommodate 2 nominal length light bar 2. Consult your local authority regarding disposal or recycling of removed ballast and lamps. LIST OF SUPPLIED COMPONENTS: URS Light Bar(s) per Chosen Kit LED Drivers(s) as Ordered Self-Tapping Screws: 2 per Bar and 2 per Driver Optional: New Channel Covers LIST OF ITEMS INSTALLER MAY HAVE TO SUPPLY: Additional wire to extend wire length or make jumpers Wire nuts Extra self-tapping screws NOTE: The instructions below reflect the steps necessary for retrofit of a typical fluorescent strip luminaire. Step 1: Remove the existing linear fluorescent tubes and properly dispose of them.

Step 2: Remove the channel covers to expose the fluorescent ballast(s). Set aside. Step 3: Cut the leads from the ballast to the socket housing on both ends of the luminaire and cap socket leads. When cutting the leads, leave the smallest amount of wire attached to the luminaire. Or, completely removed the sockets and wiring. Installer s choice. If the new URS Light Bar is to mount where sockets are located, the sockets will have to be removed. Step 4: Cut the leads from the ballast to the input power ensuring to leave as much length as possible for electrical connections. Remove ballast from housing and dispose of properly. Step 5: Push exposed socket leads back into socket housing on each side of the luminaire or cap any exposed accessible leads. Step 6: Prepare input power by stripping input power leads 5/8.

Step 7: Bring new driver into channel using mounting holes from old ballast when possible and secure it using supplied self-tapping screws. Ensure that the existing luminaire channel is properly grounded to ensure proper driver grounding. If housing has multiple locations for power supply, new driver can be secured in any of these locations. Step 8: Make the input electrical connection per diagram on the face of the LED Driver. The White Input Wire is the Neutral. The Black or Red Input Wire is Line Voltage Input from 100 277 Volts. Ensure that the driver is properly grounded to the luminaire. Step 9: The LED Driver comes standard with 0-10 Volt Dimming. The Red, Purple, and Grey wires on the output side of the driver are for dimming functions. If the dimming functions will not be used, leave the quick disconnect on the 3 wires.

If the dimming functions will be used, this is the function of the dimming wires: Purple: 0-10V + Dimming Input Grey: 0-10V Dimming Input Red: Input Power Supply for Dimmer at 12 Volts Step 10: Bring channel cover(s) previously removed in Step 2 to the channel. The red and black output leads from the driver need to come through the channel cover(s). Route the driver outgoing leads through a hole drilled in the channel cover with bushing by the installer or the tombstone openings if they were removed allowing leads to be exposed. Reattach channel cover(s) insuring no wires are pinched. Step 10 Optional: Use new channel cover(s) provided by Linmore LED. Knockouts for driver output wires are provided. Step 11: Determine where each URS Light Bar will be located on the channel cover. Place the Light Bar against the channel cover. The magnet in the Light Bar End Caps will hold the Light Bar in place until is it mechanically fastened. Start a self-tapping screw for one end of the URS Light Bar. Locate the opposite end of the URS Light Bar and set a self-tapping screw in the chosen location.

Step 12: If necessary, finish installing the remainder of the URS Light Bars in the manner described in Step 11.

Step 13: The URS Light Bars have a press-in style connector on each end visible through the clear end caps. The press-in connectors are both marked by color (red=positive and black=negative) and printed on the LED strip is + & - indications of the same, respectively. Step 14: Compact any excess wire lengths under the channel cover. Step 15: Restore the power supply to the fixture and ensure proper operation.