STEADYWEB TENSION CONTROLLER Data Sheet

Similar documents
TECHNICAL REFERENCE MANUAL DIGITAL TENSION CONTROLLER STEADYWEB 5

PRODUCT GUIDE. Some DFE Advantages. Quik-Cal. Tension Roll Transducers Idler Roll with Integrated Tension Transducers Patented in 1988

MAGPOWR Spyder-Plus-S1 Tension Control

DC3N Non-Regenerative DC Drives

TRAC-3 TENSION READOUT AND CONTROL

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

SM-1000 SERIES ROTARY ACTUATORS

Tension Control Systems

S4 Controller OPERATOR S HANDBOOK. Montalvo. Operator s Handbook

5001TCP SPEED CONTROLLER

Fincor Series 2230 MKII/2240

EZ-TRAC Digital Tension Readout and Control

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

GE Sensing & Inspection Technologies

Type Type 1001 Transducers. I/P & E/P Transducers

Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes

Tension Measurement, Display, & Control PRODUCT GUIDE

RP-4000 Reserve Power Control

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

5001TCP SPEED CONTROLLER

Say hello to better web control.

MODEL MSD MOTION CONTROL INSTALLATION AND OPERATION

Control Systems. All necessary control circuits with safety interlocking for the following system will be provided:

INSTRUCTION MANUAL MODEL THN TENSION TRANSDUCERS DOC

Super Calendar. Heated rolls

MaxPak Plus Analog DC V S Drive

ELECTRIC ACTUATORS. Series 70 Pgs 4-11 PRODUCT QUALITY & PRECISION INTRODUCTION

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Product Guide: Series III Pump Control Board Set (RoHS)

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

ASYN205B Central Synchronizing Controller

INSTRUCTION MANUAL DIGITRAC % 2 DIGITAL TENSION READOUT AND CONTROL

TAKE IT TO THE NEXEN LEVEL

INSTRUCTION MANUAL RUE ENSION TENSION INDICATOR. Models TI17C and TI18C with Quik-Cal 5 YEAR WARRANTY DOVER FLEXO ELECTRONICS, INC. ISO 9001 CERTIFIED

Super Calendar. Heated rolls

Table of Contents General Specifications, Available Mountings... 1 Introduction... 2 Application Examples... 3 Features... 4 Theory of Operation... 5

T-1001 TYPE 1001 I/P & E/P TRANSDUCERS

Electric Actuator EQ Series

RAPID-AIR OPERATING INSTRUCTIONS FOR RD317S, RD417M RIM DRIVE

Web Control Products Table of Contents

control systems Made in Italy Integrated systems for the web tension regulation

Carbon Monoxide Transmitter

controlling process tension

DENISON HYDRAULICS Jupiter 500 Driver Card Series S

Model Q45H/ Residual Chlorine Monitor...

Avtron Model M3. Rotary Pulse Generator. Easy to Install Cost Effective Rugged Construction High Resolution Versatile

Table of Contents General Information Specifications Dimensions Programming Instructions Installation Parts List Input Devices

Current Switches and Transducers

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications

DOVER FLEXO ELECTRONICS, INC. ISO 9001 CERTIFIED INSTRUCTION MANUAL. Models FH and FV Tension Transducers 5 YEAR WARRANTY

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

Applications: Conveyors, machine tools and other applications requiring adjustable speed. Mult. Sym.

How to Select the RE Industrial Actuator Part Number

Modern ManufacturingServices.LLC. Attachments And Auxiliary Equipment

Vacuum Gauge Catalog

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

CABINET REEL OPERATING INSTRUCTIONS

Data Sheet. I/P and E/P converters. RS stock numbers ,

DC Drive Selection Guide

Quartz. Save Space with Low Profile Design

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

Parr Instrument Company

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

ROTARY Point Level Measurement for Inventory Control

HYGROMETERS HUMIDITY MEASUREMENT YOU CAN COUNT ON.

North American Automatic Manual Reset and Motorized Valves

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

Pirani Vacuum Gauges. Digital and Analog Vacuum Gauge Systems. Features and Benefits. HPS Products (800) (303)

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

Electric Actuated 3-Way Ball Valves T-Port, Stainless Steel, Full Port 1/4 to 2 inch NPT

Technical Data Sheet FT & FIT-1003 SERIES AIR VOLUME/ VELOCITY TRANSDUCERS. Features DESCRIPTION

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Automatic Changeover Medical Manifold Installation, Operation and Maintenance Manual

RESISTIVITY MONITOR/CONTROLLERS

Series 20 Installation Instructions

Boston Gear Ratiotrol DC Motor Speed Control

MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS

Electropneumatic Timing Relays Series 7000 Industrial

MCS-203 Dancer Control

Figure 1: WPR2 Dimensions and Hardware

Model 124 Filter Minder & Model 124

Electric Actuators Maximum in-lbs

Prism PI Intelligent features offer advanced performance

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

Electric Actuators Maximum in-lbs

COMPLETE LISTING OF OPTIONS. Toggles, Lights

Troubleshooting Bosch Proportional Valves

SRX Series Stainless Steel Body Air Cylinders with Continuous Position Feedback

CPW Current Programmed Winder for the 890. Application Handbook. Copyright 2005 by Parker SSD Drives, Inc.

Transcription:

STEADYWEB TENSI CTROLLER Data Sheet Dover offers a variety of analog SteadyWeb tension controllers. They are used to operate pneumatic or electric brakes and clutches, eddy current clutches, and DC and AC drives. A large selection of standard and optional features makes SteadyWeb controllers the most advanced and versatile in the industry. They all feature wide tension control range without recalibration. The SteadyWeb controller is fully automatic. The operator sets the tension set point control to the desired tension. The transducers measure actual tension. The controller compares actual BENEFITS Automatic tension control - no manual adjustments needed Simple to use and operate - no special skills or training required. Large, easy-to-read meter, displays actual web tension. Helps reduce or eliminate web breakage, registration, and stretching problems. Helps reduce product waste. VERSIS tension with desired tension and adjusts torque output of the brake, clutch, or drive to make actual tension the same as desired tension. The controller automatically compensates for speed changes, roll diameter changes and other factors to maintain desired tension. Web tension is displayed on a large analog or digital meter so the operator can see it easily at a glance. SteadyWeb controllers feature soft start and bumpless auto/manual switching. Sample/hold and multiply/divide circuits provide smooth operation during flying splices on either unwind or rewind. Permits higher running speed without losing control of web Wide tension range without recalibration. Fast and easy to install - quick start up. Economical, with a fast payback. Compatible with automated factory systems. Produces consistent tension, roll after roll. P V D 0-5 psi (0 to 5. bar) output for use with pneumatic brakes and clutches. Most commonly used in the unwind and rewind zones. System includes internal air filter and regulator (0-0 psi input pressure). 0-90 Vdc output. For use with all types of electrical brakes and clutches including eddy current clutches. Also available with 4 and 45 Vdc output. Commonly used in the unwind or rewind zones. FRT PANEL WITH STANDARD AND OPTIAL FEATURES 0-0 Vdc compensated output for use with adjustable speed DC and AC drives. The output is electrically isolated for compatibility and reliability. Used in all tension zones; unwind, rewind, and intermediate. TENSI /OFF TENSI METER - Analog shown with optional non-standard meter scale. Optional Digital Meter also available SYSTEM STATUS LIGHTS TAPER TENSI (option) On/Off Selector (rewind applications only) TENSI LIMIT SWITCH RESET (option) Resets TLS after it has tripped POWER Turns controller On and Off STATUS TENSI SOFT START SAMPLE & HOLD RATIO E-STOP POWER TENSI TAPER 3 4 5 6 9 0 0 TENSI OFF TLS RESET LOW HIGH CALIBRATE A B TAPER 3 4 5 0 3 4 5 0 6 9 0 6 9 0 TENSI ADJUSTMENT Sets tension in the Auto mode / Select Auto or Manual control of tension TAPER TENSI ADJUST (option) Sets amount of tension decrease from core to full roll (rewind applications only) DUAL CALIBRATI (option) Switch between two calibration settings and/or meter scales TENSI ADJUSTMENT Sets fixed output METER Indicates 0-00% of maximum output

STANDARD FEATURES 0-0 Volt Tension Output. Used to interface with computers or other control systems. 4-0mA Tension Output. Used to interface with computers or other control systems and tension displays. Emergency Stop. Stops the tension controlled device quickly in an emergency situation. Upon a contact closure, controller goes to full output or zero output. Meter Damping. Eliminates rapid tension meter fluctuations and displays an average tension. Switch Selectable Output Direction. Select between normal and reverse output. Increases output when tension exceeds set point. Used in intermediate applications where transducers are located after nip rolls. Ratio Output Up or Down. OPTIS Multiplies or divides the 30V Power Input. 4V Output OR 45V Output (V only). Attached Power Cord (APC). A heavy duty 3 conductor power cord wired to the device by DFE. Additional Tension Meter (ATM). An additional meter to the standard one in the enclosure. Usually installed remotely by the customer. Provided loose, no enclosure furnished by DFE. Additional Tension Meter in Enclosure (ATME). Mount the auxiliary tension meter in an enclosure. Bipolar 0 Volt Output (B0). -0V to +0V output. Usually a controller output. Blank Meter Scale (BMS). No numbers on analog tension meter scale, only scale divisions. Chassis Configuration (CC). No operator devices, just enclosure with PCB attached to blank cover panel. Dual Calibration (DC). Allows two calibration settings. Digital Meter. (DM) 4 / digit red LED, "(5mm) high, in place of analog meter. Dual Transducer Input. (DTI) Accepts tension inputs from two different transducer sources. Extended Range output (XRE). Makes the transducers twice as sensitive (transducer must also have XR option). External Taper Adjustment (XTA). Taper adjustment pot. is moved from internal circuit card to front panel for easy adjustment. Metric Pneumatic Fittings (MPF). Metric size air fittings in place of inch size. Negative 0 Volt Output (N0). Output goes from 0 to - 0V, instead of from 0 to +0V. Nonstandard Meter Scale (NMS). DFE stocks many analog meter scales. We will make up a nonstock scale upon request. All option cards are available in kits and may be purchased separately. A kit includes mounting hardware and instructions. control output during flying splice operations. Remote Tension On/Off. Accommodates additional tension On/Off buttons in remote locations. Remote Tension Set Point. Allows location of Auto tension set point pot outside the controller. Sample and Hold. Used in flying splice applications. Upon a contact closure, output is maintained at constant level until contact is opened. Soft Start. Used on unwinds only. Insures control output is low when machine starts. Actuated in 3 ways: Tension Level, Remote Contact Closure, and Tachometer Speed Signal (optional, tach card required). Standard Meter Scales. 0-, 5, 0, 5, 50, 00, 50, 50, 500, or 000. Remote Tension Meter in Enclosure (RME).A standard tension meter in an enclosure for remote mounting. Remote Operator Panel (ROP). Enclosure with a blank cover panel, and 6 foot harness (different lengths optional) to the front panel with all operator devices. Remote Pneumatics. (RPA) A separate bracket housing the pneumatic components (P only). Remote Pneumatic Assembly in Enclosure (RPE) Servo valve, filter, regulator remotely installed in an enclosure. Remote Tension Amplifier. (RTA) The controllers internal amplifier is not used and is replaced by a remotely located amplifier. Accepts a 0-0Vdc signal. Reverse Output (RO). Output increases when tension exceeds setpoint. Speed Follow by DC Tach (SFD). Output is mostly determined by a DC tach speed signal and is trimmed by the transducer signal. Used to activate Soft Start. Speed Follow by Pulse Tach (SFP). Output is mostly determined by a pulse tach speed signal and is trimmed by the transducer signal. Used to activate Soft Start. Tension Limit Switch. (TLS) Relay actuates at a pre-set adjustable trip point. Can be used as a web break detector. Tension On Relay (TOR). Turning tension on actuates an SPDT relay for customer use. Taper Tension. Tension tapers with diameter increase as calculated electronically using inputs from: two DC tachs (TTD), two pulse tachs. (TTP), or as sensed by a follower roll or ultrasonic sensor (TTF). For rewinds only.

SPECIFICATIS: Power Input: P and D = 0/30 Volts 60/50Hz Single Phase @ amp, V = 0/30 Volts 60/50Hz Single Phase @ 5 amps Output Control Range: P=0to5psi(0to5. bar), V = 90 Vdc, 45 Vdc, 4 Vdc, all @ 4 amps, and D = 0-0 Volts dc (isolated) Tension Signal Output: 0to0Vdc,or4to0mAwith 500 Ohm maximum load Enclosure: NEMA Type, Steel Weight: 6 lbs. (. kg) Air Connections (P only): In: 3/" (9.5 mm) compression fitting for plastic tubing (5/6", mm optional), Out: /4" (6 mm) compression fitting for plastic tubing Internal Air Filter (P only): 5 micron with / pint bowl and automatic drain Transducer Power Supply: 5 Vdc, regulated, 0 Vdc with extended range Transducer Signal: 500 millivolts dc per pair at rated load, Vdc with extended range Mating Transducer Cable Connectors: Amphenol MS306A-0SL-3S Zero Range: 95% of transducer rating, minimum Calibration Range: 5: Temperature Range: 3 F to 04 F (0 C to 40 C) System Accuracy: % to 3% typical Tension Meter: Heavy-duty, % accuracy with flame proof front or optional 4 / digit digital with " (5mm) display Maximum Output Adjustment Range: 0% to 00% Minimum Output Adjustment Range: 0% to 0% of maximum Manual Output Range: 0% to 00% of rated output Output Multiplier Range (ratio): :0 Output Divider Range (ratio): 0: Tension Limit Switch relay contacts (option): SPDT, rated at 0A@ 30Vdc, 0A@ 50Vac Taper Tension Range (option): 0% -00% adjustable Taper Tension Inputs (option): code TTD (using DC tachs = Maximum of 3 Vdc to 50 Vdc switch selectable, code TTP (using Pulse tachs) = 300Hz to 40,000Hz at maximum line speed, and code TTF (external voltage) = 0-0 Vdc core to full roll ORDERING INFORMATI You may order by description, or by matching the labeled digits with your choices. Example: SWP-R-00-DM,XRE, SWX - X - XXX - OPTIS (Separated by commas) P = Pneumatic V = Electric D = Drive ZE U = Unwind R = Rewind I = Intermediate METER SCALE = 0-5 = 0-5 0 = 0-0 5 = 0-5 50 = 0-50 00 = 0-00 50 = 0-50 50 = 0-50 500 = 0-500 000 = 0-000 30 = 4 = 45 = APC = ATM = ATME = B0 = BMS = CC = DC = DM = DTI = MPF = N0 = NMS = RME = RO = ROP = RPA = RPE = RTA = SFD = SFP = TLS = TOR = TTD = TTP = TTF = XRE = XTA = Z= OPTIS 30 Volt Power Input 4 Vdc Output 45 Vdc Output Attached Power Cord Additional Tension Meter Additional Tension Meter in Enclosure Bipolar 0V Output Blank Meter Scale Chassis Configuration Dual Calibration Digital Meter Dual Transducer Input Metric Pneumatic Fittings Negative 0V Output Non-Standard Meter Scale Remote Meter in Enclosure Reverse Output Remote Operator Panel Remote Pneumatic Assembly Remote Pneumatic Assy in Enclosure Remote Tension Amplifier Speed Follow by DC Tach Speed Follow by Pulse Tach Tension Limit Switch Tension On Relay Taper Tension by DC Tach Taper Tension by Pulse Tach Taper Tension by Diameter Follower Extended Range External Taper Adjustment Special (SPR) Notes:. Transducers must have XR option.. Show both meter scales separated by a backslash if DC option is selected.

DIMENSIS STANDARD STEADYWEB - ALL VERSIS Note: Allow 0.5" (9mm) clearance on the top for the cover to be removed (req. to open), and 5" (mm) clearance on the left side for the controller to open completely. 0.40 (64) 0.9 () 6.5 (59).4 (36) 9.40 (39).44 (36).66 (96) () KEYHOLES FOR /4-0 OR M6 SOCKET HEAD CAP SCREWS 0.50 (6).6 (95) TRANSDUCER CNECTORS.4 (63) 4.0 (9) 5.0 (3) 0.4 (9) 0.96 (4) FRT SIDE BACK REMOTE OPERATOR PANEL AND CHASSIS CFIGURATI Remote Operator Panel includes Front Panel, enclosure with blank cover panel, and cable connecting the two. Chassis includes just the enclosure, with PCB attached to blank cover panel. FRT PANEL ENCLOSURE 0.35 CSK TYP 3 9. (36). ().9 (03) 0.65 ().4 (3). (5).50 (3) 9.40 (39).6 (6) 0.64 () 5.3 (35) 0.46 (66) 0. (6).66 (96) C/L () KEY HOLES FOR /4-0 OR M6 SOCKET HEAD CAP SCREWS 0.50 (6) 0. DIA. (4.6) TYP 0.4 () 4.0 (9) FRT SIDE SIDE BACK 0.4 (9)

DIMENSIS OF THE REMOTE PNEUMATIC ASSEMBLY (RPA) 3.00 (6) 4.5 (6).5 (4) 0.56 (4) 3.3 (0).00 (5) 0.34 (9) () HOLES FOR /4-0 OR M6 SOCKET HEAD CAP SCREWS ELECTRICAL CNECTOR /4" NPT AIR IN 3/ TUBE /4 TUBE EXHAUST /4 TUBE / NPT Drain Drain 5.5 (46) DIMENSIS OF THE REMOTE PNEUMATIC ASSEMBLY ENCLOSURE (RPE) 0. (3) 3.50 (9).00 (03) 6.00 (5). () 6.50 (65).50 (9) 0.5 (54) 0.00 (54).9 (30) TOP 9.00 (9) OFF 0.30 () dia. FRT 3.50 (9) 3.00 (6).50 (64).50 (64) 4.5 (0) 6.00 (5) BOTTOM T H E T E N S I O N C O N T R O L S P E C I A L I S T S DOVER FLEXO ELECTRICS, INC. PICKERING ROAD, ROCHESTER, NH 036 USA 603-33-650 FAX 603-33-35 E-Mail: info@dfe.com Internet: www.dfe.com ISO 900 Certified 004 DOVER FLEXO ELECTRICS, INC. ALL RIGHTS RESERVED DOC 0-065 R3 CP 04 PRINTED IN USA