SYSTEM CONTROL KIT. Model: CK-41F ITEMS INCLUDED IN KIT:

Similar documents
SYSTEM CONTROL KIT. Model: CK-41F. Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas appliances.

Q35 Series Automatic Vent Damper System

ELECTRONIC FIREPLACE DAMPER

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

G72x Series Direct Spark Ignition Controls

E Series CE Approved Intermittent Pilot Ignition Control

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

First Correlating Revision No. 1-NFPA [ Section No ]

INSTALLATION DATA 712 Series Pilot

G821L/G822L Series Integrated Function Direct Spark Ignition Controls

G76x Direct Spark Ignition Controls

UV-AIRE AIR PURIFYING SYSTEM

G600 Series Replacement Intermittent Pilot Ignition Controls

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

BG1600M Intermittent Pilot Ignition Control

SERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL

ORDERING INFORMATION SPECIFICATIONS APPLICATION

G23 Bulletin # September 1998 Supersedes June 1995

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

Utility Distribution System

G861 Series Integrated Function. Direct Spark Ignition Control

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Transfer Switch GPTS 30

Safety & Installation Instructions

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

CORPORATION REPAIR MANUAL HWH SPACEMAKER ROOM EXTENSION SYSTEM NO LEVELING SYSTEM FOR NATIONAL RV NON-MOTORIZED VEHICLES

M436A/M836A,B Damper Motors

PBA Series Prelube Controls

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Y99AB-4 BASO Test Kit

VC2, VC4, VC60, VC8 ON-OFF ACTUATOR FOR VC SERIES BALANCED HYDRONIC VALVES SPECIFICATIONS INSTALLATION INSTRUCTIONS

R81EAA Type Plug-In Electronic Circuit Board Kit For Series M100 Motor Actuators

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

ELECTRIC SHOCK HAZARD/FIRE AND/OR EXPLOSION HAZARD. ELECTRIC SHOCK HAZARD/FIRE AND/OR EXPLOSION HAZARD.

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC260N & BC335 OPERATING & MAINTENANCE INSTRUCTIONS

INSTRUCTION, TRAIL CHARGER KIT P/N

Safety Pilot System For Vented Gas Logs

Installation, Operation and Maintenance Manual

Gas Conversion Kits and Instructions

36H Gas Control Product Information

Q345A, Q3451, Q3481, Q348A, Q348B, Q362A, Q373A, Q381A and Q3452 Intermittent Pilot Burner/Igniter-Sensors

NOTICE: The information contained on the following page(s) was produced prior to May 1, On that date Reznor became part of Nortek, Inc.

COOKSON OWNER'S MANUAL

Installation, Operation and Maintenance Manual

Models: AFVK-SP-SPLIT AFVK-SP-H/L-SPLIT AFVK-SP-MH/L-SPLIT INSTALLATION AND OPERATING INSTRUCTION

Direct Gas-Fired Heating

BCS Modutrol Motor M7484A

Transfer Switch TS-50. Owner s Manual

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING

SRC. An Outdoor Reset Control for Sub-Atmosphere Steam Systems OUTDOOR TEMPERATURE

TECHNICAL MANUAL WENDY'S RANGE MODEL: C0300HT AND C0301 HT

MODERUSTIC Battery Operated Remote Control Electronic Safety Pilot System IPI Intermittent Pilot Light For Fire Pits or Fireplaces

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

Installation Manual. English. French

ITS-50R TRANSFER SWITCH OWNER S MANUAL

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

ACF Operation Manual

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

Applies to: Models F, B, FE, and BE with spark pilot

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

Installation instructions for KIT15017, KIT15018, KIT15019, and KIT15020

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

MASTERsine Inverter PXA Series Installation Guide

INSTALLATION INSTRUCTIONS For Light*Waves Flex II Kit with 300-Watt remote transformer

GAS CONVERSION KIT INSTALLATION INSTRUCTIONS

Electronically Commutated Motor Wiring Manual

Modulating Furnace Information. Warning on Meter Setting - Read First!

BGH2UNCNTRLHT-01 Universal Hot Surface Ignition Control

Installation, Operation and Maintenance Manual

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

HEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N

S4562C 1085 COMBI BOARD APPLICATION. Contents PRODUCT HANDBOOK. General

Electric Range installation manual

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

TM-1620 OPERATING INSTRUCTIONS AND OWNERS MANUAL

XC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace

FUEL KITS P/N & 526-4

T500 Series. Applications. Features. Applicable Literature. Non-Digital, On/Off Thermostat General Instructions

Manifold Isolation Valves

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL INFORMATION

MA-5200 Series MA-5300 Series

- Wiring Brochure Zone Manager 335

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

System 350 P352AB Electronic Pressure Control Series

B21 Series BASOTROL Gas Valve

- Wiring Brochure Zone Manager 336

P66 Series Electronic Fan Speed Controls

INSTALLATION INSTRUCTIONS FOR PCDE-36VA CONVERSION KIT

Installation, Operation, and Maintenance Manual. Automatic Fire Damper

Introduction. System Components

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting

EXTREME R MOTOR OWNER'S MANUAL

Transcription:

SYSTEM CONTROL KIT Model: CK-41F ITEMS INCLUDED IN KIT: 1) Junction box with mounted pressure switch and post purge timer 1) Fan control gas pressure switch 1) 2 ft. length of 1/4 inch aluminum tubing 2) Flexible conduit connector 1) GSK-3 Spillage switch 1) 1/4 inch tubing connector Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas appliances. This device MUST be installed by a qualified agency in accordance with the manufacturers installation instructions. The definition of a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged in, and is responsible for, the installation and operation of gas appliances, who is experienced in such work, familiar with all the precautions required, and has complied with the requirements of the authority having jurisdiction. DO NOT DESTROY THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT 2630 Airport Road Kinston, NC 28504 Phone: 252-522-3031 Fax: 252-522-0214 www.fieldcontrols.com

Figure 1 Figure 2 MOUNTING JUNCTION BOX The junction box can be mounted at the venter or remotely mounted away from the venter. (See Figure 1 & Figure 2) NOTE: Make sure pressure switch is in a vertical position. The pressure switch will not sense properly in a horizontal position. 1. Remove one of the knockouts from the side of the junction box where the pressure switch is mounted. Install the flexible conduit connector onto the CK-41F junction box and secure with fastening nut. If remote mounting the CK-41F junction box, mount the flexible conduit connector onto a 2" x 4" installer supplied junction box. 2. Fasten the flexible conduit from the SWG Venter into the conduit connector. Mount the CK-41F junction box or installer supplied junction box onto the wall or floor joist without straining the flexible conduit. Fasten the CK-41F junction box through the four dimpled locations on the base of the box. (See Fig. 3) PRESSURE SWITCH SENSING TUBE INSTALLATION Figure 3 1. Attach the 1/4 inch tubing connector to the pressure tube on the SWG Venter. (See Figure 3) 2. Connect the supplied 1/4" aluminum tubing to the tubing connector. Route the tubing to the CK-41F junction box and connect the tubing to the pressure switch. When routing the tubing, avoid kinking the tubing by bending the tubing too sharply. For remote mounted CK-41F Junction Box, use a 1/4" OD copper, aluminum or plastic tubing and route the tubing to avoid contact with any heat source. A maximum of 80 feet of ¼ tubing can be used with the SWG Series power venter. Page 2

PROVING SWITCH ADJUSTMENTS After proper air flow is established, the pressure switch adjustment is made by turning the pressure switch adjustment screw clockwise (See Figure 4) until burner operation stops. Turn the adjustment screw counter clockwise until burner ignites. Turn the adjustment screw an additional ¼ to ¾ turn counterclockwise to ensure adequate switch adjustment. WARNING: Failure to properly adjust the pressure switch as specified above could lead to improper operation of the pressure switch, which will result in a hazardous condition and bodily harm! THERMOSTAT HEAT ANTICIPATOR ADJUSTMENT After venting kit installation and checkout, check the amperage current draw through the thermostat circuit and adjust the thermostat anticipator accordingly. Figure 4 WIRING INSTRUCTIONS CAUTION: DISCONNECT ELECTRICAL POWER WHEN WIRING POWER VENTER, Wire the venter motor and controls in accordance with the National Electrical Code, manufacturer's recommendations and/or applicable local codes. UNITS MUST BE GROUNDED. Check ground circuit to make certain that the unit has been properly grounded. The wiring should be protected by an over-current circuit device rated at 15 amperes. CAUTION must be taken to ensure that the wiring does not come into contact with any heat source. All line voltage and safety control circuits, between the venter and the appliance, MUST be wired in accordance with the National Electrical Code for class one wiring or equivalent methods. Route the venter motor and control wiring with an appropriate wiring method. Refer to Wiring Diagrams. LOW VOLTAGE WIRING INSTRUCTIONS FOR BOILERS AND WARM AIR FURNACES 1. With boilers, locate terminal on spark ignition module or gas valve, (if standing pilot) which would normally be 24 volts hot on a call for heat. With spark ignition systems, this terminal could be TH-W or 24 V depending on the spark ignition control. 2. With warm air furnaces, locate terminal W in furnace junction box. 3. Remove wire from this terminal and reroute to T1 on CK-41F. 4. With boilers, connect T3 on CK-41F to hot side of gas valve (if standing pilot) or to terminal TH-W or 24 V, if spark ignition. NOTE: Remember, the correct terminal is the one that would normally be hot on a call for heat. 5. With warm air furnaces, connect T3 on CK-41F to terminal W in furnace junction box. 6. Connect T2 on CK-41F to a 24 volt neutral on transformer or where convenient, or to the C terminal in the furnace fan center. LINE VOLTAGE WIRING INSTRUCTIONS 1. Connect 120 volts hot power source wire to terminal L1 on CK-41F. 2. Connect 120 volts neutral power source wire and white wire from venter motor to terminal N on the CK-41F. 3. Connect black wire from venter motor to terminal M on the CK-41F. REFER TO THE SWG VENTER INSTALLATION INSTRUCTIONS FOR SETTING SYSTEM AIRFLOW. Page 3

Diagram A Typical Furnace Wiring Diagram B Boiler Wiring with Aquastat Page 4

Page 5

Page 6 Diagram E

SYSTEM CONTROL CHECK OUT PROCEDURES 1. For furnaces or boilers, adjust the thermostat to call for heat and observe the power venting system for proper operation sequence. (Repeat if necessary) a. Thermostat calls for heat. b. Relay is energized and venter motor starts. c. Pressure switch closes and burner starts. d. Thermostat is satisfied, the burner stops. e. This starts the post purge cycle. Purge time 1 to 2 min. 2. While system is operating, disconnect power to the venter motor. This should open the pressure switch contacts and stop burner operation. TROUBLE SHOOTING HINTS 1. Venter does not activate when thermostat calls for heat. a. Check wiring. b. Check for 24 volts between T1 and T2 on the CK-41F control kit. c. If there is 24 volts replace post purge timer. 2. Flue gas odor. a. Check system draft. b. Check for negative pressure in building. REPAIR AND REPLACEMENT PARTS REPAIR AND REPLACEMENT PARTS LIST DESCRIPTION PART NUMBER Pressure Switch 46083000 Post Purge Timer 46282800 Page 7

INSTALLATION INFORMATION MODEL NO.: CK-41F INSTALLER'S NAME: INSTALLER'S COMPANY: INSTALLER'S PHONE NO.: DATE OF INSTALLATION: Page 8 P/N 46335000 Rev A 10/06