Power Metering. Energy Metering Energy Targeting Energy Monitoring. Product Guide. Innovation by Design. iautomation.com.au

Similar documents
Get smart. Reduce energy consumption

Independent Energy. Home solar battery systems Energy Intelligence developed by

9200 Revenue Meter. Model Certification Current Inputs. Complies with the accuracy requirements of the ANSI C Revenue Metering Standard

MAY 2018 Improving CAPEX and OPEX of PV power plants with high power string inverters Gianluca Pieralli (Regional Sales Manager Lat Am) / Gianluca

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

Save Money By Metering Electricity Usage Easily Connect Submeter To Existing WiFi Networks

Safe, reliable, long lasting Lithium Iron Phosphate battery. Next generation capture and release technology. Increased efficiency for greater savings

PQstorI One stop solution for energy storage and power quality

1 EASY COMMISSIONING GUIDE FRONIUS PV-SYSTEM CONTROLLER

Improves fan ef ciency

Safe, reliable, long lasting Lithium Iron Phosphate battery. Next generation capture and release technology. Increased efficiency for greater savings

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

Power Perfector. Testing for Energy Savings. Undertaken by the Environmental Technology Centre. University of Nottingham.

OSC is your electric meter expert. When you have questions or need assistance in selecting the proper meter for the job, call us!

/ The personal storage solution for 24H sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

One-Stop Service: Monitoring and Managing.

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

SEMIS ABB semiconductor simulation tool Web manual - two-level VSC

Annual Distribution Pricing Proposal For 1 July 2018 to 30 June 2019 Overview

Industrial furnaces. Innovative solutions for your success

APC03 capacitor bank series The ABB comprehensive solution for automatic power factor correction

SEMIS Simulation Tool for 6 pulse Controlled Rectifier

Power IT LV Active Filters PQFI - PQFM PQFK - PQFS

Features and Benefits. Certifications

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

Using cloud to develop and deploy advanced fault management strategies

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

SonoMeter 30 Energy Meters

PQube 3 Modbus Interface

KM Metering Inc. Product Catalog Smart Meters. EKM-Omnimeter Pulse v.4. EKM-Omnimeter II UL v.3

WELCOME! Today we d like to Introduce you to your North American Rotary UPS Solutions Partner!

Emergency Back-up Power Generation for Water & Wastewater Facilities

SonoMeter 30 Energy Meters

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

THYRO-PX SERIES DIGITAL THYRISTOR SCR POWER CONTROLLER UP TO 2900 AMPS

Est Battery Data Logger BDL3000

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

MD Series Power and Energy Metering Product Overview

THREE-PHASE STORAGE SOLUTION EFFICIENT MODULAR REVOLUTIONARY

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Acuvim-L Series. Multifunction Power Meter. Max & Min

WZMC-402 Ultrasonic Apartment Energy Meters

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

TECHNOLOGICALLY ADVANCED ENERGY PRODUCTS. Product Preview & Price List 2018

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

80V 300Ah Lithium-ion Battery Pack Data Sheet

Efficiency Standards for External Power Supplies

COUNTIS E22 Three-phase energy meter Direct - 80 A

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

COMPRESSOR SYSTEMS MADE IN GERMANY COMBI SCREW COMPRESSORS

COIL WINDING TECNHOLOGY LINE. Advanced High-Tech Solutions for Coil Winding Process Control

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Wallbox Commander. User Guide WBCM-UG-002-EN 1/11

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

Proudly 100% Australian Owned Manufacturers & Distributors of Variable Speed Drives & Soft Starters ECODRIVE Solar Variable Speed Drive

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

EVD-ice FOR PS SERIES

powerperfector Voltage Power Optimisation

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

MASTERYS IP+ 10 to 80 kva

kvah Billing - Frequently Asked Questions (FAQs)

Alberto Carini, June 2013 MNS irpp The ABB s Power Distribution Units

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Is Uncorrected Power Factor Costing You Money?

24. SOLAR INCENTIVE PROGRAM II

Metering Products Protection Units Current Transformers. April 1, 2015

PowerCommand iwatch Wireless

EM DC Multi-Function DC Energy Meter

Energy Storage and Other Energy Control Solutions

UTM10 Series Ultrasonic Transit-time Flowmeters

Residential Energy Storage System SH 5K

PowerCom Pre-Payment. November Next Generation Smart Grid Solutions. For Further Information Please Contact:

200 kva* Noise level (Generator online) Fuel tank size (approx. 5.5 hours autonomy) 1400 liters 308 gallons /370 US gallons

Chapter 3.1: Electrical System

Power Factor Correction

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

White Paper Load Banks for Power System Testing

Virginia Tech Research Center Arlington, Virginia, USA

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

Electric Power Marketing Spec Sheet Continuous Power Module CPM250

Electric Switchboards

Using Apollo Solar Remote Monitoring Software

Power Switching Devices

THREE-PHASE. FRONIUS ENERGY PACKAGE / The personal storage solution for 24 hours of sun. EFFICIENT FLEXIBLE REVOLUTIONARY

Refrigerated incubator with Peltier technology

LV Capacitor Bank APC

NOBEL FIXED SPEED from 5.5 to 37 kw NOBEL DV VARIABLE SPEED from 7.5 to 37 kw

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

Managing the renewables challenge in secondary distribution networks. Tim Spearing, Product Marketing Manager Lucy Electric, United Kingdom

Liebert. FP 50Z kva

OPERATING INSTRUCTIONS MCP-MT1

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

GUASCOR LEROY SOMER P 732 control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

Rate Schedules. Effective 1/1/2019

Transcription:

Power Metering Product Guide 015 Energy Metering Energy Targeting Energy Monitoring iautomation.com.au Innovation by Design

is a leading innovator in the area of lighting control, bringing the very latest environmentally based products to the market. We are specialists in lighting control solutions, power metering, KNX lighting control systems utilising the latest products from around the globe, and engineering them for Australian conditions. Our sensor based systems have been installed in some of the largest building projects in Australia including the Royal Children's Hospital Victoria, Melbourne Airport, Robina Hospital Queensland. These systems have provided state of the art efficiency for lighting control. We offer free services for sensor design layouts, quote requests, wiring diagrams, complete product technical information & technical assistance. Call us for all your sensor requirements and lighting control solutions. iautomation.co.nz

Introduction Requirements for energy metering represent one of the least clearly understood issues affecting building services in new and existing premises. As a result many people have failed to meet mandatory requirements while others have adopted unnecessarily complex and costly solutions. Sometimes it is possible to install a relatively simple, cost-effective metering system that is future-proofed to allow for more advanced automatic metering and targeting (AM&T) systems to be introduced at a later stage. Two important legislative developments have been enacted in Australia recently. The first was the introduction in the Building Code of Australia 010 of Part J8.3 mandating the provision of sub-metering in Buildings other than Dwellings aimed at encouraging an effective sub-metering strategy. A building with a floor area of more than,500 m must have the facility to record individually the energy consumption of air-conditioning plant including, where appropriate, heating plant, cooling plant and air handling fans artificial lighting appliance power central hot water supply internal transport devices including lifts, escalators and travelators other ancillary plant The second is the introduction of the Commercial Building Disclosure program established by the Building Energy Efficiency Disclosure Act 010. Commercial Building Disclosure (CBD) is a national program designed to improve the energy efficiency of Australia s large office buildings. Under the program, from 1 November 010 most sellers or leases of office space of,000 square metres or more will be required to obtain and disclose an up-to-date energy efficiency rating. Certain exceptions and exemptions apply. There is a transition period for the first year of the program where a valid National Australian Built Environment Rating System (NABERS) Energy base or whole building rating can be disclosed. From 1 November 011 a full Building Energy Efficiency Certificate (BEEC) will need to be disclosed. BEECs are valid for 1 months, must be publicly accessible on the online Building Energy Efficiency Register, and include a NABERS Energy star rating for the building an assessment of tenancy lighting in the area of the building that is being sold or leased general energy efficiency guidance Environmental Rating Tools NABERS is a performance-based rating system for existing buildings. NABERS rates a building on the basis of its measured operational impacts on the environment, and provides a simple indication of how a building owner or tenant is managing these environmental impacts compared with their peers and neighbours. Green Star is a comprehensive, national, voluntary environmental rating system that evaluates the environmental design and construction of buildings. The ratings tools cover a number of categories that assess the environmental impact that is a direct consequence of a projects site selection, design, construction and maintenance. Under the Energy category (Ene), credit points are available where sub-metering is provided for all substantive energy uses within the building or tenancy, and where there is an effective mechanism for monitoring energy consumption from all energy sub-meters. iautomation.com.au

Power Metering Product Selection Chart Key Standard Not available when Modbus Comms Module selected 3 x Single phase values Note Optional M Available via Modbus Only Metered paramaters available on Modbus Comms (if applicable) unless otherwise noted iautomation.co.nz

Power Metering Product Selection Chart iautomation.com.au

Product Range Energy Meters Multi Function Meters Power Quality Meters Ethernet Meters Models EM1000/1030 MFM000 PQM3000/3500 netmeter4000/4500 Function Energy Metering Multi Function Power Quality Ethernet Enabled Features kwh, kw, Pulse output, 3 Phase. kwh, kvar, kw, Hz, Amps, Run hours, Volts. kw, kvar, kvarh, inductive, capacitive, peak demand, max demand, amps, Hz, hours run, %THD, power factor, peak amp demand. kw, kvar, kvarh, inductive, capacitive, peak demand, max demand, amps, Hz, hours run, %THD, power factor, time average volt, harmonics. Rating Class 1 Class 1 Class 1 Class 1 CT Type External and/or 330 mv External and/or 330 mv External and/or 330 mv External and/or 330 mv Integral Web Server NA NA NA Data logger and web server Modbus TCP I/O 1 pulse output pulse output pulse output / pulse input NA Max Demand Optional Standard Standard Standard Comms Modbus (optional) Modbus RTU (optional) Modbus RTU (optional) Ethernet Pulse Scalable 1-1000 Scalable 1-1000 Scalable 1-1000 Scalable 1-1000 Other Options Dual Tariff iautomation.co.nz

Split Core Current Transducers Part No. Model Type Class Burden Hole Size Dimensions 7600 XH-SCT-T16 50A/0.33V 1-16mm (dia) 33(w) x44.5(h) 7601 XH-SCT-T16 100A/0.33V 1-16mm (dia) 33(w) x44.5(h) 760 XH-SCT-0750 150A/0.33V 1-18mm (dia) 51(w) x53(h) 7603 XH-SCT-150 400A/0.33V 1-3mm (dia) 85(w) x8(h) 7604 XH-SCT-000 800A/0.33V 1-50mm (dia) 10(w) x17.5(h) Current Transformers Part No. Model Type Class Burden Hole Size Dimensions 78053 MSQ-30 50/5A 1.5VA 4mm (dia) 74.5(w) x98(h) 78054 MSQ-30 80/5A 1 1.5VA 4mm (dia) 74.5(w) x98(h) 78060 MSQ-40 100/5A 0.5 1.5VA 31mm (dia) 74.5(w) x98(h) 78061 MSQ-40 150/5A 0.5 1.5VA 31mm (dia) 74.5(w) x98(h) 7806 MSQ-40 00/5A 0.5.5VA 31mm (dia) 74.5(w) x98(h) 78063 MSQ-40 50/5A 0.5 5VA 31mm (dia) 74.5(w) x98(h) 78064 MSQ-40 300/5A 0.5 5VA 31mm (dia) 74.5(w) x98(h) 78065 MSQ-40 400/5A 0.5 5VA 31mm (dia) 74.5(w) x98(h) 78070 MSQ-60 500/5A 0.5 5VA 46mm (dia) 103(w) x17(h) 78071 MSQ-60 600/5A 0.5 5VA 46mm (dia) 103(w) x17(h) 7807 MSQ-60 800/5A 0.5 7.5VA 46mm (dia) 103(w) x17(h) 78073 MSQ-60 1000/5A 0.5 10VA 46mm (dia) 103(w) x17(h) 78074 MSQ-60 100/5A 0.5 10VA 46mm (dia) 103(w) x17(h) 78075 MSQ-60 1500/5A 0.5 10VA 46mm (dia) 103(w) x17(h) 78076 MSQ-60 1600/5A 0.5 10VA 46mm (dia) 103(w) x17(h) 78085 MSQ-85 000/5A 0.5 15VA 8mm (dia) 18(w) x164(h) 78097 MSQ-100 500/5A 0.5 10VA 6.5mm (dia) 144(w) x156(h) 78098 MSQ-100 3000/5A 0.5 10VA 6.5mm (dia) 144(w) x156(h) Split Core Current Transformers Part No. Model Type Class Burden Hole Size Dimensions 78100 XH-3 100/5A 1 1VA 0x30mm 90(w) x110(h) 78101 XH-3 150/5A 1 1VA 0x30mm 90(w) x110(h) 7810 XH-3 00/5A 1 1.5VA 0x30mm 90(w) x110(h) 78103 XH-3 50/5A 0.5 1.5VA 0x30mm 90(w) x110(h) 78104 XH-3 300/5A 0.5.5VA 0x30mm 90(w) x110(h) 78105 XH-3 400/5A 0.5.5VA 0x30mm 90(w) x110(h) 78106 XH-88 500/5A 0.5.5VA 80x80mm 145(w) x159(h) 78107 XH-88 600/5A 0.5.5VA 80x80mm 145(w) x159(h) 78108 XH-88 800/5A 0.5.5VA 80x80mm 145(w) x159(h) 78109 XH-88 1000/5A 0.5 5VA 80x80mm 145(w) x159(h) 78110 XH-18 100/5A 0.5 7.5VA 80x10mm 145(w) x00(h) 78111 XH-168 1500/5A 0.5 15VA 80x160mm 185(w) x48(h) 7811 XH-168 000/5A 0.5 15VA 80x160mm 185(w) x48(h) 78113 XH-168 500/5A 0.5 15VA 80x160mm 185(w) x48(h) 78114 XH-168 3000/5A 0.5 15VA 80x160mm 185(w) x48(h) iautomation.com.au

General Purpose kwh Meters EM1000/1030-D (Din rail mount) EM1000-P (Panel mount) Models EM1000/1030-D Part no Mounting Description Values Model EM1000-P Standard features Designed for simple installation, the EM1000 Series meets the need for low cost effective energy monitoring solutions: Applications Modbus Network RS485 (optional) Current Transformers Monitored Parameters Legend 1000 1000/1030-M 1000-M-DT 50%- 10% 50%- 10% 50%- 10% V iautomation.co.nz

Models EM737-MID-D Multi function EM 737-D (Din rail mount ) Direct connect EM 737 series is an a cost effective meter that represents the latest in quality and expanded features with its 100 amp direct connect model and class.5 accuracy. With its large LCD display it offers unmatched value for features while delivering outstanding performance. With the Modbus now a standard and a large display!!!, It is also MID approved guaranteeing accuracy. Part no Mounting Features Values Model EM737-CT Modbus Network RS485 (standard feature ) Utilizing the optional features of this meter enables connection to either Modbus or Pulse giving connectivity to large installations at very low costs. All measurements taken by the meter are available when needed in real-time! Standard features Data can be collated via????? software available from iameters. Applications Display Monitored Parameters 3 phase, 1-100 Amp 3x CT Current Transformers EN50470-3 class.5 EN50470-3 class.5 50%- 10% 50%- 10% Legend 1 1 6 integer, decimal 6 integer, decimal iautomation.com.au

Power Quality meters PQM3000/3500-P (Panel mount) Model PQM3000-P Part no Mounting Description Display Model PQM3500-P Standard features Modbus Network RS485 (optional) Applications v v v v Current Transformers Monitored Parameters Legend 3000/3500 3000/3500-M 3000/3500-M-I/O 50%- 10% 50%- 10% 50%- 10% iautomation.co.nz

Ethernet netmeter netmeter-d4000 (din rail mount) Part no Model netmeter-p4000/4500 (Panel mount) Mounting Features HTML netmeter4000-d Energy Management & Sytem Meters RJ45 Model netmeter4000/4500-p Standard features HTML screens from meters Web browser Building Lan Ethernet Ethernet 19.168.0.3 19.168.0.4 Applications Easy to read Uses standard web browser 19.1680. 19.168.0. v DB # DB #1 Current Transformers Monitored Parameters Legend iautomation.com.au 4000/4500-EM 4000/4500-SM 4500-SM-I/O 4500-EM+I/O 50%- 10% 50%- 10% 50%- 10% 50%- 10% 1-1000 pulse per kwh

Integral Web pages Data retrieval through HTML web pages Profile Data Display up to 9 HTML pages VALUES HISTORY 3 PHASE PER PHASE GRAPH 1 GRAPH PROFILE TOTALS & ALARMS HELP SETUP Plots A plot of stored values - Energy consumption in kwh and kvarh - shown as the average kw and kvar for each bar of the bar chart. Values are plotted as a bar graph. Options available include Day, week, month and annual profile. Bar chart of one years data with the facility to zoom in for better resolution. Navigate by selecting a month, week then day. Pop up data view of the raw meter readings to copy to a spreadsheet. Phase Per Phase Real time Voltages, Currents & Power Factors for the 3 phases. Note. If the PFs of two of the phases (or any other readings) seem wrong then the Meter may be incorrectly wired. 3 Phase Real time instantaneous 3 phase powers. Energy Total 3 phase Energy consumption to date together with cost & carbon emissions. Values Refresh Rates The refresh rates can be altered. Graphs Web enabled energy meter Power Factor The meters display instantaneous system Power in kw, Power Factor and the average of the three Currents and Voltages. Readings are updated every few seconds to track changing load conditions. 3 Phase Real time instantaneous 3 phase powers. Graph 1 Volts & Current A real-time graph of the instantaneous three Currents and the average Voltage. Full scale values for the vertical Y-axis can be altered via the Setup menu. iautomation.co.nz

am&t Software iautomation.com.au

am&t Software Reality is a powerful Monitoring and Targeting (am&t) software system which enables you to collect and analyse half hourly data from utility meters, data loggers and building management systems. It will also collect driving factor details such as production quantities and weather data and merge this with your metered energy consumption information. With Reality you can get a detailed analysis of all your energy usage - by building, department and tenant, and by product, cost centre and shift. A number of Energy Dashboards are available to display energy parameters in a user friendly format. Produce reports on energy consumption in a variety of formats for evaluation. Compare these with previous periods. Produce reports on energy consumption in a variety of formats for evaluation. Compare these with previous periods. iautomation.co.nz

Connection diagrams 3-Phase 3 wire or 4-Wire 3 Phase 3 wire CT High voltage Single Phase Dimensions Din Rail Type Panel Mount Type 9mm 9mm The information contained in this brochure is correct at the time of publication, but is subject to change without prior notice, due to further development of the product details contained herein. Errors and omissions excepted. iautomation Pty Ltd Publication Date: 09th Sept 014 Publication Number: SZ0909014 iautomation.com.au

Australia 1800 5 063 www.iautomation.com.au iautomation.co.nz