Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

Similar documents
1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

BRAVER UPS. (Uninterruptible Power System) User s Manual

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

USER MANUAL. On-Line UPS Model ZS VA/2000VA/3000VA. Uninterruptible Power Supply System

User's Manual VENUS SMART VA TRUE ONLINE DOUBLE CONVERSION UPS

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

USER MANUAL MPS 1-5KW SERIES

USER MANUAL ONLINE UPS

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

LIFT 1500 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

User Manual Rittal PMC UPS 6kVA

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Uninterruptible Power System

Mission 1K Single Phase UPS

OPERATIONAL MANUAL .TYPE - ONLINE UNINTTERRUPTIBLE POWER SUPPLY

Foreword. Manual instruction

USER MANUAL. PowerMust 1080 LCD (1KVA), Online, IEC PowerMust 2016 LCD (2KVA), Online, IEC PowerMust 3024 LCD (3KVA), Online, IEC

General Precautions. Personnel Precautions

1. Important Safety Warning

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

Uninterruptible Power Supply

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

USER MANUAL. Uninterruptible power supply MODEL: 53965,

CP900EPFCLCD User s Manual K

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. User s manual

Uninterruptible Power System

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

Uninterruptible Power System

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Foreword

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

PR1000ELCD / PR1500ELCD User s Manual

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Pulsar EXtreme CLA 1500C

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

Uninterruptible Power System

Delta UPS - Ultron Family. HPH Series, Three Phase 20/30/40/60 kva 208V. User Manual. The power behind competitiveness

USER MANUAL. PW Series Inverter / Charger

Liebert GXT MT+ User Manual VA Installer/User Guide

Informer Compact Series

USER S MANUAL SOLAR POWER INVERTER KW-6KW

USER MANUAL. GS Series Hybrid Inverter

ST1K series specification

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

Eclipse Plus VA UPS and Surge Suppressor User s Manual

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

1. INTRODUCTION. Features:

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

User Manual V1.0 MaxiFlex 3000

NEWTECH PRO X KVA DSP LCD 1/1 ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Liebert PSA VA. Installer/User Guide

ST6K(S) series specification

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

USER MANUAL DN / DN

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

User Manual. 1P-1P 6KL/7.5KL/10KL Online UPS

User Manual. 3/1 10K~30K Online UPS

Powerware Vdc Extended Battery Cabinet User s Guide.

Pulsar Evolution 2200/3000/3000 XL

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

02/15/01. Powerware User s Guide VA.

PowerValue 11/31 T kva

Electrical Installation

Technical Data Sheets

POWERWARE User s Guide VA.

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

User Manual 1KVA-5KVA INVERTER / CHARGER

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

USER MANUAL. E4 LCD TX 5000(S) / 6000(S) / (S) With Output Isolation Transformer. Uninterruptible Power Supply System

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Liebert GXT3 UPS 230V 700VA-3000VA

Centurion 1000/1500/2000/3000 Tower/Rackmount On Line UPS User s manual

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

User Manual / Manuel utilisateur

Back-UPS CS Back-UPS CS 350

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

User Manual. PF0.9 6K/10K Online UPS

U P S. Uninterruptible Power System Unterbrechungsfreie Stromversorgung

Transcription:

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS until reading through this manual carefully. Observe the warnings on the unit and please comply with all warnings and operating instructions in the manual strictly. Save this manual properly for future reference.

Copyright Declaration EATON is committed to technical innovation and providing quality products and services to meet customers' demand. The product specifications are subject to change without notice. All rights reserved. Safety information Operation 1. Read this manual carefully and thoroughly before operating the UPS and save this manual properly for future reference. 2. All the warnings and operating instructions on the UPS and in this manual must be strictly complied with. 3. Avoid installation of the UPS in a location under direct sunlight, near running water, or excessive humidity. 4. Do not install the UPS in the environment where it is close to heating facilities such as space heaters or furnaces. 5. Position the UPS in a room with good ventilation, enough space for installation and adequate airflow for heat sinking. Refer to the manual to carry out the installation. 6. Cleaning with dry stuff, do not use liquid or spray detergent. 7. In the event of a fire occurring in the vicinity, please use dry powder fire extinguishers.the use of liquid fire extinguishing agents may causes electric shock. Electricity 1. Verify the cabling and the polarities of the battery cable (for XL models) are correct with protective earth ground provided before powering on the UPS. 2. Before moving or re-wiring the UPS, please disconnect it from the mains source outlet and make sure the UPS is completely powered off. Otherwise, the output outlets of the UPS may have live voltage, thus presenting electric shock risk. 3. Consult the authorized distributors or service center for further information. 4. The length of the output cables should be less than 10m in order to comply with EMC requirements. Battery 1. High ambient temperature shortens the battery' s lifespan, the battery should be replaced periodically to ensure normal operation of the UPS and for adequate autonomy. 2. Servicing of battery should be performed or supervised by personnel who is knowledgeable of battery. 3. In replacement of battery, please use the same number and same type of the battery. -2-

4. A battery can present a risk of electrical shock and high short circuit current. Pay attention to the following precautions prior to battery replacement. A. Metal objects, such as rings and watches shall be removed; B. Use tools with insulated handles; C. Wear rubber gloves and boots; D. Do not lay tools or metal parts on the batteries; E. Disconnect the load before removing the wirings from the battery. 5. Do not dispose of batteries in a fire, they may explode. 6. Do not open or mutilate the battery. It may cause an electrolyte leakage that is toxic and harmful to the skin and eyes. If electrolyte comes into contact with the skin, wash the affected area with plenty of clean water immediately and go to the hospital for further checkup. 7. Do not make the positive and negative terminals of the battery short circuit; otherwise it may cause electric shock or fire. Maintenance 1. The operating environment and storage method are two main factors affecting the service lifetime and reliability of the UPS. It is advisable not to use the UPS in the following environments: Where the temperature and relative humidity are out of the specifications (temperature:0 ~ 40, relative humidity: 20%~90%.) Where vibrations or shocks are existing. Dust, corrosive agents or inflammable gas are present. 2. If the UPS does not use for a long period, it shall be kept in a dry environment. The storage temperature should be between -25 ~+55 (without battery). If the UPS has been kept in the area where its temperature is lower than 0, please keep the UPS in a location with the ambient temperature over 0 for a certain period of time before powering on the UPS. -3-

Contents 1 Introduction Descriptions of Commonly Used Symbols 2 Product Description 2.1 Models and Configuration 2.2 The Appearance of the UPS 2.3 Operating Principle 3 Installation 3.1 Unpacking and Inspections 3.2 Installation Notes 3.3 Cable Connections 3.3.1 Connections of Input and Output 3.3.2 Operation Procedures of External Battery for Long Backup Time models 3.3.3 Connection of Communication Cable 4 Operation 4.1 Control Panel 4.2 LCD display 4.3 Start up 4.4 Shut down 5 Battery Maintenance 5.1 Control Panel 6 Troubleshooting 6.1 How to judge the UPS run in abnormal 6.2 Troubleshooting table 7 WARRANTY 8 SPECIFICATIONS 8.1 Environmental 8.2 EMC standards 8.3 Safety 8.4 Industrial Standards 5 5 5 5 6 7 8 8 8 9 9 10 11 13 13 13 13 16 17 17 18 18 19 20 21 22 22 22 22-4-

1 INTRODUCTION Descriptions of Commonly Used Symbols Some of the following symbols may be used in this manual and may appear in your application process. Therefore, all users should be familiar with them and understand their meanings. Symbol & Description Symbol Descriptions Alert you to pay special attention Danger of electrical hazard Alternating current source (AC) Direct current source (DC) Protective ground Recyclable Do not dispose of with ordinary trash 2 PRODUCT DESCRIPTION EATON DX Series is of true online UPS (Uninterruptible Power Systems) designed with an advanced double-conversion technology. It provides perfect protection especially for critical loads, such as computers, communications systems as well as computerized instruments. The double-conversion design eliminates all mains power disturbances. A rectifier converts the alternating current from the utility power to direct current. This direct current charges the batteries and powers the inverter. On the basis of this DC voltage, the inverter generates a pure sine wave AC power which is constantly powering the loads. 2.1 Models and Configuration There are two types of UPS according to the battery configuration: standard type and long backup time type, each available in the following ratings: 1kVA, 2kVA and 3kVA UPS. -5-

Table 2-1 UPS types and configurations Standard model Long Backup Time model Type Model Remark 1kVA UPS DX 1K With internal batteries 2kVA UPS DX 2K With internal batteries 3kVA UPS DX 3K With internal batteries 1kVA UPS DX 1KXL Without internal batteries, but equipped with high power charger 2kVA UPS DX 2KXL Without internal batteries, but equipped with high power charger 3kVA UPS DX 3KXL Without internal batteries, but equipped with high power charger * Note: XL stands for Long Backup Time model. 2.2 The Appearance of the UPS Intelligent Slot RS232 EPO Network/Fax/Modem Surge Protection Output Input External Battery Connector Figure 2-1The rear panel of DX 1K Figure 2-2The rear panel of DX 1KXL Intelligent Slot EPO RS232 Network/Fax/Modem Surge Protection Output External Battery Connector Input Figure 2-3The rear panel of DX 2K Figure 2-4The rear panel of DX 2KXL -6-

Intelligent Slot EPO RS232 Network/Fax/Modem Surge Protection Output Output Terminal Block External Battery Connector Input Figure 2-5The rear panel of DX 3K Figure 2-6The rear panel of DX 3KXL 2.3 Operating Principle Bypass Input Input Filter AC/DC Converter DC/AC Inverter Output Filter Output Charger DC/DC Converter Battery Figure 2-7 System block diagram 1. Input filter: It is for input noise filtering and provides clean AC power to the UPS. 2. AC/DC converter: In AC mode (Utility Power mode), it converts the AC input power to regulated DC power source for the inverter. 3. DC/DC converter: It boosts the DC Voltage from the battery to the optimum operating DC power for the inverter when the UPS is in Battery mode. 4. DC/AC inverter: It utilizes the regulated DC power of the AC/DC converter in AC mode or DC/DC converter in battery mode to generate a pure, clean and regulated sine wave AC power for output. 5. Bypass: The UPS automatically transfers to bypass mode powering the output load direct from utility power through the filters in the event of any fault of the UPS or the UPS is severely overloaded. 6. Charger: It charges the battery when the UPS is in AC mode. The output charging current of the standard models of DX 1K, DX 2K and DX 3K is 1A; the output charging current of the long backup time models of DX 1KXL and DX 2K XL / DX 3K XL is 7A and 8A respectively. 7. Battery: sealed lead acid maintenance-free battery is used as DC power source for standard models and is strongly recommended to be used as the DC source for long backup time models. 8. Output filter: It provides clean AC power for the output load. -7-

3.1 Unpacking and Inspections 3 INSTALLATION 1. Unpack the UPS and examine the unit to see if there is any damage during transportation. 2. Check the accessories of the UPS as below.(refer to Table 3-1) 3. If the appearance of the UPS is damaged, or there is any missing accessory, please contact the distributor immediately. Table 3-1 List of Accessories Model Accessory Quantity Standard model long backup time model User manual 1 WinPower software (CD) 1 Communication cable 1 Input Power Cable 1 Output Power Cable 2 User manual 1 WinPower software (CD) 1 Communication cable 1 External Battery Cable 1 Input Power Cable 1 Output Power Cable 2 3.2 Installation Notes 1. The UPS must be placed in a location with good ventilation, far away from water, inflammable gas and corrosive agents. The ambient temperature of the UPS should be kept in the range of 0 to 40. 2. The UPS should not be tilted. The air inlet port at the front panel and the outlet port on the rear panel should not be blocked so as to ensure good ventilation. 3. If the UPS is unpacked, installed and used at very low temperatures, condensations of water drops may appear. It is necessary to wait until the UPS fully dried inside out before proceeding to installation and use. Otherwise, there may be a risk of electric shock. 4. Place the UPS near the utility power source outlet which supplies power to the UPS and must be easily accessible. In any emergency, shut off the UPS and unplug the input power cord from the wall outlet. All power sockets must be connected with protective ground. -8-

3.3 Cable Connections 3.3.1 Connections of Input and Output 1. Input cable connection If the UPS is connected via the power cable, please use a proper socket with protection against electric current, and pay attention to the capacity of the socket: over 10A for DX 1K/ DX 1KXL and DX 2K, over 16A for DX 2KXL and DX 3K/ DX 3KXL. The wiring configuration is shown in the following diagram. 2. Output connection Table 3-2 Output of the UPS Rating Figure 3-1 Connection Method of Input for 1~3kVA Model Quantity of output socket Output Terminal Block 1kVA DX 1K / DX 1KXL 4 Nil 2kVA DX 2K / DX 2KXL 6 Nil 3kVA DX 3K/ DX 3KXL 4 Available The output of DX 1K/ DX 1KXL, DX 2K/ DX 2K XL and DX 3K/ DX 3K XL are available to use sockets for output connections. The total output power shall not exceed 1kVA/0.8kW, 2kVA/1.6 kw, 3kVA/2.4 kw. Simply plug the load power cables to the output sockets to complete connection as shown in the following diagram Figure 3-2 Connection method of output for 1~3kVA -9-

Apart from using the sockets for output connections, DX 3K/ DX 3K XL has the terminal block available for output as well. It is recommended to use this terminal block for output connection when its drawing current of the equipment is over 10A. The wring configuration is shown in the following diagram. Refer to the procedures as below, 1) Remove the small cover of the terminal block; 2 2) Use AWG14 (2.1mm ) wires for wiring configuration; 3) Upon completion of the wiring configuration, please check whether the wires are securely affixed; 4) Put back the small cover to the rear panel. Figure 3-3 Connection method of terminal block for 3kVA * Caution: The wiring connection of the terminal block shall be carried out by professional personnel. 3.3.2 Operation Procedures of External Battery for Long Backup Time models The battery connection procedures are very important. Any incompliance may result in the risk of electric shock. Therefore, the following steps must be strictly complied with. 1. Firstly connect the batteries in series of a battery pack to ensure proper battery voltage that is 36Vdc for DX 1K XL, 72Vdc for DX 2K XL and 96Vdc for DX 3K XL. 2. A battery cable for connection of the external battery pack comes with the UPS, one end of the external battery cable is a plug for connection to the UPS, the other end has 3 open wires for connection to the output of the battery pack. 3. Connect the external battery cable to the output terminals of the battery pack (DO NOT connect the plug of the cable to the external battery socket of the UPS first. Otherwise, it may cause electric shock). Connect the red wire to the: + terminal of the output of the battery pack. The black wire is connected to the - terminal of the output of the battery pack. The green/yellow wire is grounded for protection purpose. 4. Connect the plug of the external battery cable to the external battery socket on the rear panel of the UPS to complete the connection procedure. -10-

Battery Figure 3-4 Battery connection diagram of Long Backup time models * Note:The length of the external battery cable is standardized. There is a limitation of the length of the external battery cable to ensure normal operation of the UPS system. 3.3.3 Connection of Communication Cable 1. RS232 interface RS232 RS232 RS232 interface-it is used to communicate the UPS through a computer which has WinPower software installed on it for power monitoring and management. -11-

2. Optional accessories Intelligent Slot Intelligent Slot: It is compatible with optional communication cards, please consult the distributor or service center for further details. a. AS400: Dry-contact closure interface. b. WebPower Card(SNMP) : Remote monitoring and management of your UPS system over the network. c. CMC: It is a Central monitor card and gives an easy and simple way to achieve remote monitoring and controlling of all the UPSs at the same time. d. USB+RS232 card * Note: 1. Remove the cover of the intelligent slot before installation of an optional card. 2. Refer to some other relative documents for the use of the WinPower software and the AS400 card, WebPower(SNMP)card or WinPower CMC card. please consult the distributor or service center for further details if you have any questions. 3. Surge protection port (RJ45) a b a. Output port for connection to the device which needs to be protected. b. Input port for connection to incoming network/telephone line. -12-

4 OPERATION 4.1 Control Panel 1 2 5 7 3 4 6 1~4LED: 1 Utility power 2 Battery 3 Bypass 4 Inverter 5 ON/ OFF button 6 Function button 7 LCD The alarm silence of the function button is valid only in battery mode and bypass mode. It cannot silence other fault warning alarms of the UPS system LED: Light Off 4.2 LCD display The LCD has five parts following: 1 Numerical display: show voltage, frequency, battery capacity, load capacity and fault code. 2 Configuration: show the connection configuration of part 1 3 Load capacity icon: show the level of the load capacity. 4 Battery capacity icon: show the level of the battery capacity 5 Alarm icon: when the UPS is abnormal the icon appearance 4.3 Start up The battery is fully charged before delivery. However, storage and transportation will inevitably cause some charge loss. Therefore, it is advisable to charge the battery for 10 hours before using it, so as to ensure adequate battery autonomy. Start with the utility power Power on the UPS, the Utility Power LED light then press down the ON button to start the UPS. -13-

After few minutes normal operation will begin, the utility power LED and the inverter LED are light, the LCD show the main menu under normal mode. UPS supplies power to the load. Press down the Function button to obtain the following information from LCD. VAC INPUT Hz LOAD % Once turn ON on, UPS will perform a self-test automatically and all of the on the LCD are light from left to right. The inverter LED on and UPS is under normal mode. If the utility power is abnormal UPS runs in battery mode. Startup without the utility power Press down the ON button to start the UPS (connect the external battery first for the long backup time models). -14-

UPS start up on battery mode, the battery LED and the inverter LED are on, the LCD show the main menu under battery mode. UPS supplies power to the load Press down the "Function button to obtain the following information from LCD. Buzzer beeps once ever 4 seconds, indicate the UPS run under battery mode. Press the "Function for more than 2 seconds can silence the buzzer. -15-

4.4 Shut down Press down the OFF button to turn off the UPS. The UPS will cut off the output (default), if set the UPS transfer to work in bypass mode after turn off form the normal mode, the utility power LED and the bypass LED are on, the LCD show the main menu under bypass mode In bypass mode the buzzer beeps once ever 2 minutes, indicate the UPS run under bypass mode. Press the Function button for more than 2 seconds can silence the buzzer. Press down the Function button to obtain the following information from LCD. Disconnect UPS from the utility power then the UPS no output voltage. -16-

5 Battery Maintenance 5.1 Control Panel The battery is the key component of the UPS. The battery life depends on the ambient temperature, charge and discharge times. High ambient temperature and deep discharge will shorten the battery life. 1. Sealed lead-acid maintenance-free battery is-used in the standard models. When being connected to the utility power whether the UPS is turned on or not, the UPS keeps charging the battery and also offers the protective function of overcharging and discharging. 2. Keep the ambient temperature between 15 and 25. 3. If the UPS has not been used for a long period, charging is recommended at the intervals of 3 months. 4. Normally, the battery should be charged and discharged every 4 to 6 months. Charging should begin after the UPS shuts down automatically in the course of discharging. In the regions of hot climates, the battery should be charged and discharged every 2 months. Moreover, the standard charging time should be not less than 10 hours. 5. Batteries should not be replaced individually. All batteries should be replaced at the same time following the instructions of the battery supplier. 6. Under normal conditions, the battery life lasts 3 to 5 years. In case if the battery is found not in good condition, earlier replacement should be made. The battery should only be replaced by qualified service personnel. -17-

6 Troubleshooting 6.1 How to judge the UPS run in abnormal If the Alarm icon is on and the LCD show fault code, it indicate that the operation is abnormal. Please followed the " troubleshooting table" A. Fault code ( fault menu) Output voltage and frequency, input voltage and frequency, load level and battery capacity are display by the LCD via press the function button. The fault menu is main menu. B.Alarm code ( alarm menu) The parameter for output, input, load level and voltage and frequency, load level and battery capacity are display by the LCD via press the function button. The alarm menu is main menu. -18-

6.2 Troubleshooting table When reporting UPS fault, please provide the following information: The machine model and machine serial No. The data of fault happened. The detail of fault, contains abnormal code, LED indications, power condition, load capacity, buzzer beeps and configuration of battery (if it is the Long Backup time UPS). -19-

When you contact the distributor or service center reporting UPS fault, please provide the following information: The UPS model and its serial No. The date when the problem arose. Complete descriptions of the problem, including LCD indications, power condition, load capacity, audible alarm and configuration of battery pack (if Long Backup time models). 8.1 Electrical 8 SPECIFICATIONS Model DX1K DX1KXL DX2K DX2KXL DX3K DX3KXL Rating 1kVA/800W 2kVA/1600W 3kVA/2400W Input Input Single phase with earth ground Output Battery Nominal voltage Voltage range Frequency 220VAC 115VAC~300VAC 50/60 Hz (auto-sensing) Power factor 0.98 Bypass Voltage range 80VAC* (1±5%) ~285VAC* (1±5%) Output Rated voltage Power factor 0.8 Single phase with earth ground 220VAC Voltage precision ±2% Output frequency AC mode 1. Syn to mains input frequency when the input frequency is in the range of 46 Hz~54 Hz or 56 ~ 64Hz 2. 50/60 Hz when the mains input frequency is out of the range of 46~54 Hz or 56~64Hz Battery mode 50/60±0.2 Hz overload capacity (Utility power,25 ) Transfer time Crest factor 108%±5%<Load 150%±5% : 47s~25s 150%±5%< Load <200%±5% : 25s~300ms Load 200%±5% : 300ms <4ms(AC mode Bypass mode) 3:1 (max) nominal voltage 36VDC 72VDC 96VDC Quantity 3 6 8 Backup Time(25 ) Battery recharge time 0ms (AC mode Battery mode) Full load 5min (Standard models) * 5 hours recharge to 90% battery capacity(standard models) * Dependent on the capacity of external batteries(long backup time models) -21-

8.2 Environmental Item Normal range Ambient temperature 0 ~40 Humidity 20% ~ 90% (non-condensing) Altitude Lower than 1000m Storage temperature -15 ~45 8.3 EMC standards Item Standard Level ESD IEC61000-4-2 LEVEL4 RS IEC61000-4-3 LEVEL3 EFT IEC61000-4-4 LEVEL4 Surge IEC61000-4-5 LEVEL4 8.4 Safety Comply with IEC62040-1 and CE requirements. 8.5 Industrial Standards Comply with EN62040,YD/T 1095-2008 requirements. -22-