Mounting TURCK inductive proximity sensors are manufactured with a shielded coil, designated by Bi in the part number, and a nonshielded coil, designated by Ni in the part number (See page C7). Embeddable (shielded) units may be safely flush-mounted in metal. Nonembeddable (nonshielded) units require a metal free area around the sensing face. Because of possible interference of the electromagnetic fields generated by the oscillators, minimum spacing is required between adjacent or opposing sensors. It is good engineering practice to mount sensors horizontally or with the sensing face looking down. Avoid sensors that look up wherever possible, especially if metal filings and chips are present. Maximum Locknut Torque Specifications s The locknut torque should be considered for all threaded sensors to prevent the housing from being overstressed. The values below pertain to the locknut provided with each sensor. Liquid thread sealants of an anaerobic base, such as Loctite, are recommended if strong vibrations are likely. Caution: Sensor barrels are typically brass. Consider break torque when selecting grade of thread sealant. Size Metal Plastic 5 mm mm mm mm mm mm 5 Nm (3.7 ft-lb) 10 Nm (7.4 ft-lb) 15 Nm (11 ft-lb) 25 Nm ( ft-lb) 90 Nm (66 ft-lb) 90 Nm (66 ft-lb) 1 Nm (0.7 ft-lb) 2 Nm (1.4 ft-lb) 5 Nm (3.7 ft-lb) Drill Hole Sizes for Metric Threads Thread Size Pitch Clr (mm) Tap (mm) Clr (in) Tap (in) M5 x 0.5 0.5 5.0 4.133 13/64 5/32 M x 1 1.0.0 6.27 21/64 1/4 M x 1 1.0.0 10.27 31/64 13/32 M x 1 1.0.0 16.27 23/32 41/64 M x 1.5 1.5.0 27.44 1-3/16 1-5/64 PG 9 1.41 15.2.76 5/ 1/2 PG 13.5 1.41 20.4 17.96 13/16 23/32 PG 36 1.59.0 44.24 1-7/ 1-/64 Tap Drill Size in Inches = [Diameter in mm - (Pitch in mm / 0.577)] 25.4 Refer to Section J for plug taps. TURCK Inc. 00 Campus Drive Minneapolis, MN 55441 Application Support: 1-00-544-PROX Fax: (763) 553-070 www.turck.com C10
TURCK Inductive Sensors - s Ferrite Core Mounting Considerations Style Rated Operating (mm) Bi0.-.. Bi0.-.. Bi 1-.. Bi1.5-.. Bi1.5-.. Ni 2-.. Bi 3-.. Ni 3-.. Bi 4-.. Ni 4-.. Ni 4-.. Bi 5-.. Ni 5-.. Ni 5-.. Bi 7-.. Bi -.. Ni -.. Ni -.. Bi10-.. Ni10-.. Ni10-.. Bi-.. Ni14-.. Bi15-.. Ni15-.. Bi20-.. Ni20-.. Ni20-.. Bi25-.. Ni25-.. Ni-.. Diameter (mm) 4 5 6.5 11 11 20 40 40 A (mm) E (mm) F (mm) G (mm) H (mm) 4 2 40 50 13 22 33 4 0 4 141 0 2.4 2.4 3 21 42 75 75 4. 4. 42 4 4 4 0 0 0 0 0 0 2. 3.3 5 4.75 5.5 7.5 14.5 17 25 43.5 70.5 Embeddable Bi (Shielded) Nonembeddable Ni (Nonshielded) A 0 A 2 x S n Mounting Formulas for Ferrite Core and Uprox E 2 x Diameter E 3 x Diameter Rated F 3 x Operating Rated G 6 x Operating Rated Operating H + 0.5 x Diameter H 1.5 x Diameter C11 TURCK Inc. 00 Campus Drive Minneapolis, MN 55441 Application Support: 1-00-544-PROX Fax: (763) 553-070 www.turck.com
Uprox Mounting Considerations The performance of a sensor can be influenced by surrounding metal and nearby sensors. This is especially critical for Uprox sensors because of their increased sensing ranges and sensitivity to all metal types. To ensure proper sensor operation, please refer to the following guidelines when installing Uprox. Style Uprox s Part Numbers A (mm) E (mm) F (mm) G (mm) H (mm) Bi1.5U-EG0-.. Ni 4U-EG0-.. Bi 2U-M-.. Bi 3U-M-.. Ni U-M-.. Bi 5U-M-.. NiU-M-.. Bi10U-G-.. Ni20U-G-.. 4 0 TURCK Inc. 00 Campus Drive Minneapolis, MN 55441 Application Support: 1-00-544-PROX Fax: (763) 553-070 www.turck.com C
TURCK - Product Spec Sheet http://www.tipwizard.com/specsheet.cfm?id=bi%205%2dg%2dap6x Page 1 of 2 5/13/2003 Part Number ID Number Mounting TURCK Sensor Specification Sheet Bi 5-G-AP6X T4641400 Embeddable (Shielded) Rated Operating 5.0 Housing Style Connection Output Voltage Output Function, Metal, Full Threading, Generally Chrome Plated Brass potted cable 3-Wire DC - PNP Transistor (Current-Sourcing) 10- VDC - Polarity Protected - Pulsed SCP Normally Open (N.O.) Housing Size.0 Number of LEDs 1 Number of Pins Material Cable/Conductor Length Options G : Chrome Plated Brass EG : Stainless Steel Sensing Face: PA -GF Plastic End Cap: PUR Plastic Cable: PVC Jacket; 2 and 7 Meter standard length Copper Conductor: G: 24 AWG (PVC insulated) G/G: 21AWG For applications requiring longer barrel lengths, consult factory on availability of the following part numbers with special 60 mm barrels: Bi 2-G-AN(P)6X, Ni 5-G-AN(P)6X Bi 5-G-AN(P)6X, Ni 10-G-AN(P)6X Ripple <=10% Differential Travel (Hysteresis) Voltage Drop Across Conducting Sensor Trigger Current for Overload Protection Continuous Load Current Leakage (Off-State) Current No-Load Current Time Delay Before Availability 3-15% (5% typical) <=1. V at 200 ma >=220 ma <=200 ma <10 µa 5.5-9.5 ma <= ms Power-On Effect Per IEC 9-5-2 Reverse Polarity Protection Wire-Break Protection Transient Protection Operating Temperature Incorporated Incorporated 2 kv, 1 ms, 1 kohms -25 C to +70 C (-13 F to +15 F) Enclosure Meets NEMA 1,3,4,6,13 and IEC IP 67 Shock Vibration Repeatability LED On g, 11 ms 55 Hz, 1 mm Amplitude in all 3 Planes <=2% of Rated Operating Output Energized
TURCK - Product Spec Sheet http://www.tipwizard.com/specsheet.cfm?id=bi%205%2dg%2dap6x Page 2 of 2 5/13/2003