Perfusion Valve Controller

Similar documents
Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

User s Manual. Model VC-8 Perfusion Valve Controller. Sweden U.S.A. Spain. Canada. United Kingdom. France. China. Germany

Bipolar Temperature Controller

Research Isometric Transducer

Model 975 / 2274 Syringe Pump Series User's Manual. Model 975 Syringe Pump MA Model 2274 Syringe Pump MA

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Econoflo Syringe Pump User s Manual

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

SPSR-115/230. Self-Powered Sensor

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Hybex Microsample Incubator

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Megohmmeter Test Probe

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Model TC-202A Bipolar/Monopolar Temperature Controller User's Manual

Model 1672, 1673 Triple Output Power Supply

Switching DC Power Supply

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

DC POWER SUPPLY ALIMENTATION C.C.

KEY FEATURES. Compact components for 360 µm, 1/16, and 1/32 inch ID tubing Fast, breadboard-based design Leak-free high pressure setups

Triple Output Power Supply

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

i3000s/i2000 Flex AC Current Probe

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

Triple Output High Resolution Power Supply. User Manual

1000FLT. Users Manual. Fluorescent Light Tester

OPERATING INSTRUCTIONS

Model 1693, 1694 Switching DC Power Supply

PHOTOMULTIPLIER POWER SUPPLY MODEL 70706

Instruction Manual. Vortex Mixers

BPS-8 system INSTRUCTION MANUAL

BPS-4 system INSTRUCTION MANUAL

Model 1900, 1901, 1902 Switching DC Power Supply

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Defender 3000 Series Base Instruction Manual

Digital/Analog Megohmmeter Model 1026 USER MANUAL

EASY CHARGE Waterproof portable Battery Charger

1260 Infinity II Degasser User Manual. 5 Maintenance

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Operators Manual. Qualstik PLUS. Live-Line Power Quality Survey Meter. SensorLink

Register your instrument! HeatSealer S100. Operating manual

PY-11 Voltage & Continuity Tester

362 Clamp Meter. Users Manual

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

INSP-3 Wiring Inspection Tester

Instruction Manual. Vibration Calibrators VC10 VC11 VC12 VC13

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

SPSR-115/230. Self-Powered Sensor

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

User s Manual Power Supply IM E. 5th Edition

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

Advanced Calibration Designs, Inc. Release II

MODEL 905V OPERATING INSTRUCTIONS

HCT-10 Temperature Controller User Manual

Product Guide: Series III Pump Control Board Set (RoHS)

KMP Insulation-Continuity Tester. Users Manual

WPS500X 500 psi /34.5 bar Automotive Pressure Transducer. User s Guide

OPERATING MANUAL TS - 4 Thermal Microscope Stage

Technical Information Manual

Instruction Manual μflow Low Volume Perfusion System V 1.2 1/11

EASY CHARGE Weather-resistant fixed mount Battery Charger

TMA5 Mini Vane Anemometer

100 Watt Power Amp 50 Watts x 50 Watts Single Rack Space

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

3-Year Limited Warranty. See the Users Manual for the full warranty.

Heated Perfusion Cube

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

GE Healthcare. Valve INV-917. Instructions

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

Model 1900, 1901, 1902 Switching DC Power Supply

DKG-114 MANUAL AND REMOTE START UNIT

CONTENT SECURITY INFORMATION... 3 GENERALITIES... 3 SECURITY... 3 POWER SUPPLY... 4 PRODUCT LOCATION... 4 CLEANING... 4 TROUBLESHOOTING...

Techcon Systems TS5322 TS5322D Adjustable Mini Spool Valve. User Guide

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

c-go 24V/6A 24V/8A 24V/12A

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

BLD75-1. Bilevel Step Motor Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

TECHNICAL DESCRIPTION

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

BLHV, BLHV-1. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

Multi-Mover Charger for model L25

OPERATION & MAINTENANCE INSTRUCTIONS

ValveMate 7000 Controller Operating Manual

ORIGINAL INSTRUCTIONS

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Transcription:

Perfusion Valve Controller Model VC-8T

WEEE/RoHS Compliance Statement EU Directives WEEE and RoHS To Our Valued Customers: We are committed to being a good corporate citizen. As part of that commitment, we strive to maintain an environmentally conscious manufacturing operation. The European Union (EU) has enacted two Directives, the first on product recycling (Waste Electrical and Electronic Equipment, WEEE) and the second limiting the use of certain substances (Restriction on the use of Hazardous Substances, RoHS). Over time, these Directives will be implemented in the national laws of each EU Member State. Once the final national regulations have been put into place, recycling will be offered for our products which are within the scope of the WEEE Directive. Products falling under the scope of the WEEE Directive available for sale after August 13, 2005 will be identified with a wheelie bin symbol. Two Categories of products covered by the WEEE Directive are currently exempt from the RoHS Directive Category 8, medical devices (with the exception of implanted or infected products) and Category 9, monitoring and control instruments. Most of our products fall into either Category 8 or 9 and are currently exempt from the RoHS Directive. We will continue to monitor the application of the RoHS Directive to its products and will comply with any changes as they apply. Do Not Dispose Product with Municipal Waste Special Collection/Disposal Required

Table of Contents 1 S U B J E C T PAGE Introduction...2 Features...2 Operating Directions...3 Setup...3 Components...3 Assembly...4 Overflow Sensor...6 Control Description...7 Front Panel...7 TTL Inputs...7 Command Input Toggle...8 Overflow...8 Rear Panel...8 Valves...8 Overflow In...8 Standby In...8 Ext Analog In...9 Event Out...9 Power Input Module...9 AC Conversion...10 Instructions for Use...10 Flow Adjustment...10 Maintenance...11 Cleaning...11 Warranty...12 Appendix...13 Specifications...13 Declaration of Conformity...14

2 Introduction The VC-8T Valve Control System lies at the heart of a multi-valve perfusion system designed to automate and control the delivery of solutions to Warner Instruments imaging and recording chambers. However, its flexible design allows the VC-8T to be used in many applications not using Warner equipment. The complete system includes a valve controller, a valve bracket with Teflon valves, connecting cable, an MPP-8 manifold, a support stand, syringe holder, eight 60 cc syringes, 25 feet of Teflon tubing, 10 feet of PE-160, 24 blunt-end 18-gauge syringe needles, and 8 stopcocks. A new and exciting feature to the VC-8 Valve Control System is the Spill Sensor Probe. This probe is used to detect the presence of an overflow condition and, when activated, will automatically shut off all valves protecting your microscope optics. The controller can independently regulate the function of up to eight valves. Individual valves can be controlled via manual switch, an external analog signal or an external digital (TTL) signal.an event marker pulse, generated each time a valve is switched on, is provided at the rear of the instrument for recording into your acquisition system. Valve transitions (opened or closed) occur at full power to insure rapid response times and are then held in place at less than half power to prevent heat transfer to solutions. F e a t u re s 8 channel individually controlled channels Teflon valves Spill sensor Manual and computer control

3 Operating Directions S e t u p Components Before beginning setup, take inventory of the supplied components. You should have: valve bracket with included Teflon valves syringe holder support stand blunt-end syringe needles (24) stopcocks (8) Teflon tubing (25 ft) PE-160 tubing (10 ft) MPP 8-port manifold VC-8 Valve Controller The VC-8T is designed to operate as a stopped-flow device wherein the valve for each channel is either open (allowing solution to flow) or is closed. In general, the shortest response time for delivery of the selected solution will be achieved by keeping the tubing length between the MAN- IFOLD and sample as short as possible.

4 Operating Directions (Cont d) A s s e m b l y 1. Begin assembly of the VC-8T by first attaching the VALVE BRACKET to the SUPPORT STAND. Place the VALVE BRACKET near the base of the SUPPORT STAND as shown on previous page. 2. This is followed by attaching the SYRINGE HOLDER to the top of the SUPPORT STAND. Place the SYRINGE HOLDER near the top of the SUPPORT STAND as shown on the previous page. 3. Remove the plungers from the eight supplied 60 cc syringes and place syringes into the SYRINGE HOLDER.Attach STOPCOCKS to each syringe. 4. Cut eight (8) pieces of Teflon tubing long enough to run from the stopcocks to the input ports on the Teflon valves. 5. Attach one (1) blunt-end, 18-gauge syringe needle to both ends of each length of Teflon tubing to provide Luer connection points. Insert a short section of PE-160 onto the needle tip to facilitate a tight seal between the Teflon tubing and the syringe needle. 6. Using the Luer-ended Teflon tubes formed in step 5, make a connection between the stopcock on each syringe to the associated input port on each Teflon valve. Proper tubing lengths, Luer connector attachments, and tubing placements are shown in the montage below. 7. Cut eight (8) pieces of Teflon tubing to run from the output ports of the Teflon valve to the supplied MPP manifold. The tubing length needed is left to the discretion of the user but should be sufficient to allow for a short connection between the manifold and the sample chamber.

5 Operating Directions (Cont d) 8. Attach the remaining blunt-end syringe needles to one end of each section of Teflon tubing. 9. Prepare the MPP manifold to accept the Teflon tubing by first sliding a short length of PE-160 tubing over the input ports on the MPP manifold. 10. Now make a connection between the output port on each Teflon valve and one input port on the MPP manifold. 11. Run a short length of PE-160 tubing from the output port on the MPP manifold to the input port of sample chamber. NOTE: If desired, you can also run Teflon tubing between the manifold and your chamber. Prepare the manifold to accept the Teflon tubing by first sliding a short length of PE-160 tubing over the output port on the MPP manifold. 12. Finally, connect the VALVE MANIFOLD to the VC-8 CONTROLLER using the attached cable.

6 Operating Directions (Cont d) O v e rf l o w S e n s o r The VC-8T Valve Control System includes a unique overflow or spill sensor designed to assist you in providing a level of protection to your microscope. The sensor itself is a small Ag/AgCl probe which grounds through the chamber bath. A resistance of 10 MΩ or less between the probe and ground will trigger the overflow circuitry. Place the probe adjacent your perfusion chamber such that the maximum solution height (say, just prior to an actual overflow) is achieved when the solution contacts the tip of the probe.contact between the probe and your solution will activate the overflow circuitry and close all the valves. The OVERFLOW SENSOR plugs into the OVERFLOW IN BNC on the rear of the controller.

7 Control Description F ro n t P a n e l The front panel of the VC-8 Valve Controller contains TTL inputs for each valve, an associated 3-position toggle switch for manually setting the state of each valve and an LED displaying the active status for each valve.there is also a 2-position toggle switch for selecting the command input mode, a SPILL SENSOR indicator, and a power switch with power on LED. TTL Inputs TTL inputs (front panel BNC s and ON/OFF TOGGLE SWITCHES) are provided for all 8 channels of the VC-8 Controller. Operation of the front panel TTL inputs is selected by placing the 2 position COMMAND INPUT TOGGLE into external digital mode. Use of these inputs can allow the opening of more than one valve at the same time from a digital source such as your computer. Placing the ON/OFF TOGGLE SWITCH into the on position places the associated valve into its open state. A lit LED indicates the open state of the valve.this setting is overridden by the overflow sensor. Placing the ON/OFF TOGGLE SWITCH into the off position places the valve into its closed state. An unlit LED indicates the closed state of the valve. Placing the ON/OFF TOGGLE SWITCH into the ext position activates the associated BNC inputs.a logic level low (0 V) applied to the BNC places the associated valve into the closed state. Correspondingly, a logic level high (3 to 5 V) places the associated valve into the open state.a lit and an unlit LED indicates the open and closed states of the valve, respectively. These settings can be overridden by the overflow sensor.

8 Control Description (Cont d) Command Input Toggle The COMMAND INPUT TOGGLE is used to select between the front panel external digital controls and the rear panel external analog controls. Overflow The OVERFLOW LED indicates an overflow condition sensed by the OVER- FLOW SENSOR.Activation of this circuit by an overflow condition immediately overrides all other settings and closes all valves. R e a r P a n e l The rear panel contains the power input module with fuse, a 15 pin D-connector for the VALVE SET, and 4 BNC connections for OVERFLOW IN, STANDBY IN, EXTERNAL ANALOG IN and EVENT OUT. Valves A 15 pin, "D" type female connector is used to connect the cable from the VALVE BRACKET to the CONTROLLER. Overflow In This BNC is used to connect the OVERFLOW SENSOR to the controller. Place the sensor into position and plug it into this BNC. Standby In This BNC is provided to allow the placing of the VALVE CONTROLLER into standby mode. Standby mode disables EXT ANALOG IN inputs and closes all valves.

9 Control Description (Cont d) Activation of this input is selected by placing the FRONT PANEL COM- MAND input toggle into external analog mode and a TTL level high (3 to 5 V) places the instrument in standby. Ext Analog In This BNC is used to operate valves using analog voltage settings.the voltage applied to this input selects the valve to open.all other vales are closed. Switching voltages closes the open valve and open the other. Valve selections are overridden by the OVERFLOW SENSOR and the STANDBY BNC. The table below indicates the selection scheme. Applied Voltage (V) Valve Selection 0 standby 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 Event Out The Event Marker output produces a 500 ms logic-level output (+5 V) each time a valve is turned on. At all other times the Event Marker output is low (0 V). Power Input Module A polarized, 3-conductor, IEC320/CEE-22 connector is used for line (mains) power input to the instrument. A removable cordset, terminated with a NEMA 5-15P connector, is standard.a fuse holder contains a protective fuse in series with the high side (brown or black wire) of the mains.the holder accepts 5 x 20 mm fuses of the type indicated.

10 Control Description (Cont d) AC Conversion Step 1 Depending on AC Voltage being used, turn VAC selector switch to 110 VAC or 220 VAC ATTENTION PLEASE READ BEFORE APPLYING POWER TO YOUR UNIT!! The unit uses only one fuse; the second one is sent as spare. Follow these instructions to change the unit(s) from 120 VAC or 220 VAC: Power Entry Module Step 2 Fuse holder side view. Push out drawer to access the Spare Fuse Active Fuse Carefully, pry open the fuse holder from the inside by using a small flat screwdriver. Replace fuse according to voltage being used. For 120 VAC: 0.50 Amp - 5 x 20 mm Slow Blow For 220 VAC: 0.25 Amp - 5 x 20 mm Slow Blow I n s t ru c t ions f o r U se Flow Adjustment Flow rates can be adjusted by raising or lowering the reservoir holder, as well as by adjusting the height of each reservoir within the holder. The table below lists the approximate flow rates for a reservoir at the specified height with the supplied Teflon tubing. Reservoir height 61 cm (24 in) 30 cm (12 in) 20 cm (8 in) Approximate flow rate 14 ml/min 9 ml/min 5 ml/min

11 Maintenance Cleaning Do not use alcohol, aromatic hydrocarbons or chlorinated solvents for cleaning.they may adversely react with the plastic materials used to manufacture the system. If salt solution spills on the valve assembly it should be cleaned as soon as possible with a soft cloth dampened with a mild solution of detergent and water. NOTE: Teflon Valves must be completely flushed with distilled water after each use. Permanent damage will result if saline solution is allowed to crystallize inside the valve. The exterior of the CONTROLLER may be cleaned periodically to remove dust,grease and other contamination.it is not necessary to clean the inside. Use a soft cloth dampened with a mild solution of detergent and water. Avoid abrasive cleaners.

12 Warranty The VC-8T Valve Control System is warranted to be free from defects in materials and workmanship for a period of two years from the date of shipment. If a failure occurs within this period, we will repair or replace the faulty component(s) at our discretion.this warranty does not cover failure or damage caused by physical abuse or electrical stress (e.g., exceeding specified input limits). Shipping charges to the factory are the customer's responsibility. Return shipping of the repaired unit will be paid by Warner Instruments, Inc.

Appendix 13 Warner Instruments Perfusion Valve Controller Model VC-8 Specifications Valve Bracket: Delrin. Mounts on 3/8 or 1/2 ring stand Valves Teflon, 12 VDC/0.25 A to maintain pinch Connection Cable 2.4 meter (8 ft) connecting cable terminated with quick disconnects on valve end and 15 pin male "D" type connector on controller end. Tubing Teflon, 1/8 OD x 1/16 ID tubing Reservoirs 60 cc capacity syringes Reservoir Holder Delrin. Holds eight syringes with thumb screws for each reservoir. Valve Controller (front panel): Power Two position on/off with power-on LED Input Select Two position selecting analog or digital inputs Switch Selection ON (manual), Off or External External Input +5 V TTL-compatible (BNC Connector) Overflow LED indicating overflow condition Valve Controller (rear panel): Overflow In BNC connection to OVERFLOW SENSOR. Triggered when sensed resistance falls below 10 MΩ. Standby In BNC connection to activate standby mode. TTL high closes all valves. Ext Analog In BNC connection for valve selection. Active valve opened by analog voltage. Event Marker Logic level pulse 500 ms nominal (rear panel BNC connector) Manifold 8/1, nominal dead space Power 110 to 130 or 200 to 250 VAC, single-phase, 50/60 Hz, 20 W Operating Temperature 10 to 40 C (50 to 104 F) Dimensions, H x W x D 89 x 203 x 305 mm (3.5 x 8.0 x 12 in) Weight / Shipping Weight 3.7 kg (8 lb) / 4.6 kg (10 lb) Operating Conditions: Equipment is intended to be operated in a controlled laboratory environment. Temperature 0 to 40 C Altitude Sea level to 2000 m Relative Humidity 0 to 95%

Declaration of Conformity CE MARKING (LVD & EMC) Application of Council Directive: 73/23/EEC 89/336/EEC Standard(s) to which conformity is declared: EN61010-1:1993 EN55022 Class A EN61000-3-2 EN61000-3-3 EN50082-1:1992 EN61000-4-2 EN61000-4-3 ENV50204 EN610000-4-4 EN610000-4-8 EN610000-4-11 Manufacturer s Name: Manufacturer s Address: Equipment Description: Equipment Class: Model Numbers: Warner Instruments, LLC 1125 Dixwell Avenue Hamden, CT 06514 T: (203) 776-0664 Valve Controller Class I, ITE-Class A VC-8 Controller I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s). Place: Hamden, Connecticut U.S.A. Signature: Full Name: Ralph Abate Position: Business Manager