SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index

Similar documents
SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI

Mixed Flow Inline Fan, Model MFSI

Tube Axial Fan Page Specifications & Dimension Data Performance Data

Centrifugal Utility Fans - SFD/SFB

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

Defining Innovation. backward curved FANs

Industrial Mini Vent Sets

Twin City Fan & Blower

Turning Air Into Solutions. PLUG FANS TYPE BCPL

SECTION CENTRIFUGAL HVAC FANS

Turbo Pressure Blowers

Twin City Fan & Blower

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Fixed Pitch Vane Axial Fan

to meet the updated test procedures outlined in the 1974 AMCA test code.

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover.

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

SECTION AXIAL HVAC FANS

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

Centrifugal Plenum Fan

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

VANEAXIAL & TUBEAXIAL FANS

Twin City Fan & Blower

FRP Fans: CLUB Series Performance and Technical Information

CPAF SERIES CENTRIFUGAL PLUG FANS CLASS II CLASS IIP CLASS III Snider Road, Mason, OH Telephone:

Defining Innovation. radial tip FaNS type Hrt BULLETIN 980 October 2009

Twin City Fan & Blower

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan RADIAL TIP FANS MODEL RTF CATALOG 950 AUGUST 2012

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

Cyclone Custom Centrifugal Fans

AXIFAN VANEAXIAL FANS

DESIGN GUIDELINES FANS PAGE 1 of 7

Twin City Fan & Blower

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan PRESSURE BLOWERS MODEL PBW CATALOG 1260 APRIL 2015

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

Vane Axial Fans Models VAB and VAD. Belt and Direct Drive

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

Tubular Centrifugal Fans

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS

Square Inline Fans with Multi-Directional Discharge

DF / DFB / DFC DOUBLE WIDTH DOUBLE INLET FORWARD CURVED FANS

Bulletin VX05 VANEAXIAL FANS

CAST ALUMINUM PRESSURE BLOWERS

SECTION HVAC POWER VENTILATORS

Centrifugal Fans belt driven. TD_CFB-RDY_EN Issue 1.1 EN July 2013

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

Industrial Material Handler Page Introduction... 2 Information Specifications MH Specifications... 6 MHR Specifications...

BACKWARD CURVED HIGH PRESSURE FANS

Centrifugal Filtered Supply Roof Blowers

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

UPBLAST AXIAL ROOF VENTILATORS

TURNING AIR INTO SOLUTIONS. PRESSURE BLOWERS. Model PBW

Air Moving Solutions. low pressure mixed flow fans. QCLB QCLBR (Restaurant) QCLBSH (Smoke & Heat)

Filtered Kitchen Supply Packaged Ventilator

FIXED PITCH PROPELLER FANS

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F.

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

EXHAUST FANS CUD & CUB UPBLAST FANS

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

SURGE LIMITING PB FANS. Designed for high pressure, low flow applications with stringent job process requirements

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

Turning Air Into Solutions. CAST IRON BLOWERS MODEL CIW

University of Delaware

FILTERED SUPPLY CENTRIFUGAL Belt Drive

Inline Fans [ 14 ] * UL is optional and must be specified.

VERANTIS. FRP Fans: CMHB Series Performance and Technical Information. Environmental Solutions Group

TUBULAR CENTRIFUGAL INLINE FANS

Good Enough Never Is. Plug Fan SERIES 12

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

North American Series 2300 Turbo Blowers 4-44 OSI & 55-11,500 CFM for standardized product 4-60 OSI, up to 100,000 CFM for custom product

LOW PRESSURE MIXED FLOW FANS

DIrect drive exhaust & supply panel fans

The Industrial Choice. Model VJ Direct Drive MANUALLY ADJUSTABLE-AT-REST VANEAXIAL FANS. Direct Drive & Belt Driven Model VJ / VJBD

SARAVEL CENTRIFUGAL FANS For Airconditioning & Industrial Application

Air Moving Solutions. axifan adjustable blade vaneaxial fans

Propeller Fan BE Series

Transcription:

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index www.sheldonsengineering.com AIR HANDLING-RADIAL BLADE CENTRIFUGAL FAN 9000 XB GENERAL The centrifugal fan shall be designed and manufactured by Sheldons Engineering to ensure smooth operation. Fan wheel shall be heavy gauge construction with a full back plate and inlet shroud model XB as shown in plans with all steel construction. Unless otherwise directed, fan arrangement, motor location, support base, rotation and discharge are as shown on the layout drawings. Fan size is defined as the OD in inches of the fan inlet. PERFORMANCE Fan ratings shall be based on tests made in accordance with AMCA Standard 210. Flow shall be actual volumetric flow at the fan inlet. Fan static pressure is defined as static pressure at fan outlet less total pressure at fan inlet. Standard inlet density is to be taken as 0.75 lb/ft 3 with corrections for temperature, elevation, inlet static pressure, gas composition and humidity as defined in the schedule. Fans shall be selected to operate to the right of the peak static pressure at the given speed to ensure stable performance. Fan brake horsepower shall rise continuously over the entire range of flows for a given speed and shall be equal to or less than specified at the given flow and fan static pressure. SOUND Fan manufacturers shall provide sound power level ratings for fans tested and rated in accordance with AMCA Standards 300 and 301. Sound power ratings shall be in decibels (reference 10-12 watts) in eight octave bands. Sound power levels will be corrected for installation by the specifying engineer...dba or sound pressure levels only are not acceptable. CONSTRUCTION Fan housings are to be heavy -- min. gauge per chart below, continuously welded construction with flanged and punched outlet. Housings with lock seams or spot welded construction are not acceptable. Fan Size Class I (12 M) Class II & III (15 &19M) Class IV (22M) 7-11 14 gauge (0.0747 or 1.89 mm) 12 gauge 10 gauge 13-26 12 gauge (0.1046 or 2.66 mm) 10 gauge 7 gauge 29-37 10 gauge (0.1345 or 3.43 mm) 7 gauge ¼ 41-49 7 gauge (0.1875 or 4.76 mm) ¼ ¼ 54-60 --- 3/8 3/8 BEARINGS (belt driven fans) Bearings are to be heavy duty, grease lubricated, precision anti-friction, self-aligning pillow block design. Bearings shall be designed for a minimum L 10 life per the chart below when rated at the fan's maximum cataloged operating speed. Class I II III IV MIN. L 10 Life 30,000 40,000 100,000 400,000 Leaders in fan technology since 1896

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index www.sheldonsengineering.com AIR HANDLING-RADIAL BLADE CENTRIFUGAL FAN 9000 SHAFT (belt driven fans) Shafts are to be ASTM A-108 steel, grade 1040/1045, precision turned, ground and polished. Grade 1018 steel is not acceptable. The shaft's first critical speed shall be at least 143% of the fan's maximum operating speed. PAINT All fan surfaces are to be thoroughly prepared prior to painting using a combination of washing and hand and power tool cleaning as required in SSPC-SP-3. After cleaning, all surfaces are to be coated with a zinc rich oxide primer. Surfaces of bolted components not accessible after assembly shall be coated and allowed to dry prior to final assembly. BALANCE & INSPECTION All fans shall be precision balanced to ISO quality grade 2.5, report to be submitted with the maintenance manual. A final inspection by a qualified inspector prior to shipment is required to include: scope of supply confirmation, balance, welding, dimensions, bearings, duct and base connection points, paint finish and overall workmanship. ACCESSORIES Accessories shall be provided as called for in the plans and specifications. Standard accessories include: Motor to be NEMA Design B 3/60/460-575V-1800 rpm, high efficiency TEFC 1.15 SF V-Belt Drives - Variable Speed/Constant Speed with min 1.5 SF Belt Guard or weather cover required Extended lubrication lines (nylon, copper or stainless steel) with fittings terminating in an accessible area. Additional Features that may be required: XHD extra heavy duty wheel construction for severe applications Access Door bolted/quick opening or plug type with raised door Housing Drain pipe ½ coupling or flanged connection Shaft Seal non-asbestos fibre or spring loaded carbon ring style Bolt-on variable inlet vanes Spark Resistant Construction AMCA A All parts in contact with the air stream of Aluminum construction AMCA B Aluminum wheel with Aluminum rubbing ring around shaft entry point AMCA C Aluminum inlet cone and Aluminum rubbing ring Horizontally Split Fan Housing Leaders in fan technology since 1896