EDGE EX3I 3 Suspended Indirect Linear

Similar documents
EDGE EX3B-WW 3 Suspended Bidirectional Linear Wall Wash

EDGE EX2 2 Direct Suspended Linear

EDGE EX6WET 6 Suspended Direct Linear WET

COVE C CV N - - Architectural Cove Mount. Key Features CRI, CCT & OUTPUT LENGTH 1 MOUNTING VOLTAGE DRIVER CIRCUITING _ N

EDGE EX3 3 Suspended Direct Linear

EDGE EV3WET 3 Recessed Linear WET

EDGE EX33 3 x 3 Suspended Direct Linear

FINA F36B 36 Bidirectional Architectural Round

FINA F48B 48 Direct and Uplight Architectural Round

EDGE EX1 1 Suspended Direct Linear

EDGE EX1B 1 Suspended Bidirectional Linear

EX3. Project Name _ K. R_x_ Rectangle. MAC JB Junction Box Movable AC

EDGE EX4B 4 Suspended Bidirectional Linear

EX3B. Project Name _ K 4000K. R_x_ Rectangle. MAC JB Junction Box Movable AC

FINA F48 48 Direct and Uplight Architectural Round

EDGE EX44 4 x 4 Suspended Direct Linear

LINERO L_6A Suspended Linear

Project Name. 4-1/4 (107.9mm) or 5-1/4 (133.4mm)

EDGE ET6 6 Recessed Linear EDGE Techx for Integrated Ceiling Systems

CONVERJ CJ14 1x4 Architectural Recessed

CONVERJ CJ22 2x2 Architectural Recessed

CONVERJ CJ24 2x4 Architectural Recessed

Project Name. (136.5mm) 11/16 (17.5m) _ K _ K _ K _ K CL - Custom Lumens CW - Custom Watts. Lumen Output pg.

EDGE EV3WW 3 Recessed Linear Wall Wash

EDGE EX3DI 3 Suspended Direct/Indirect Linear

LiFT LF12 1x2 Architectural Recessed

Evolution Outline RECESSED LINEAR PERIMETER OUTLINE SLOT SYSTEM

Project Name. 24 (609.6mm)

EDGE EV6 6 Recessed Linear

Project Name. 24 (609.6mm) 24 (609.6mm)

EDGE E4 4 Recessed Linear

Project Name ADEO AD24 EMERGENCY. G1-15/16 Grid G9-9/16 Grid GS - Screw Slot Grid FL - Flanged S - Surface Mount. Mounting pg. 3

Project Name. 23-3/4 (603.3mm)

Project Name ADEO AD14. Adeo 1x4 (AD14) 1x4 Architectural Recessed. (76.2mm) EMERGENCY

EDGE EV1 1 Recessed Linear

Project Name ADEO AD22 EMERGENCY. G1-15/16 Grid G9-9/16 Grid GS - Screw Slot Grid FL - Flanged S - Surface Mount. Mounting pg. 3

Project Name LUCEN LU14. 1x4 Architectural Recessed EMERGENCY. G1-15/16 Grid G9-9/16 Grid GS - Screw Slot Grid FL - Flanged S - Surface Mount

LUCEN 2x2 ARCHITECTURAL RECESSED LUMINAIRE

Project Name. 23-5/8 (600.2mm)

EDGE EV3D 3 Recessed Linear

SURFACE MOUNTED. Project. Type. Notes. culus Listed Type I.C.

REGOLO 1. RP11 Direct

RECESSED T-Bar & Drywall. Project. Type. Notes 23 15/16" 23 7/8" SIDE VIEW. culus Listed Type I.C.

CYL8 8" Integrated LED Indoor and Outdoor Cylinders

Verve IV. fixture information. Suspended linear direct/indirect LED with frosted lens or Radial Baffle options.

RECESSED T-BAR & DRYWALL. Project. Type. Notes. 0.5 StepLens. StepLens

WALL MOUNT DIRECT/INDIRECT. Project. Type. Notes

2 1/2. Applies to both UP & DOWN. Specify quantity. Requires 8" blank See integrated controls guide for more details.

SURFACE MOUNT. Project. Type. Notes

PENDANT MOUNT - DIRECT

PERIMETER - RECESSED. Regressed 3" BMPRLED OPRI ( 1) 14 PRODUCT ID LINEAR OR CORNER QTY TOTAL LENGTH. 3D VIEW - Inside Corner Pattern

PERIMETER - RECESSED. Flush BBPRLED OPRI ( 1) 14 PRODUCT ID LINEAR OR CORNER QTY TOTAL LENGTH. 3D VIEW - Inside Corner Pattern

Cubic SurroundLite TM

15/16" Grid (G) Ceiling. 4 = 4 ft 6 = 6 ft 8 = 8 ft. AC = Cable PD = Pendant G = Grid MG = Mini Grid

Project. Type. Notes. C custom UNV universal BI bi-level dimming +NL(#) night light circuit (7) O other (6) +GTD(#) generator transfer device (7)

SURFACE ASYMMETRIC MOUNT. Project. Type. Notes

WALL MOUNT - DIRECT/INDIRECT

WALL MOUNT DIRECT. Project. Type. Notes

PTP Series PTPL-24-DI

PENDANT MOUNT - DIRECT. Project. Type. Notes

Seem 4. Narrow extruded aluminum 4" linear direct/indirect LED with Pop-lens options.

PENDANT ASYMMETRIC MOUNT - DIRECT. Project. Type. Notes

SURFACE FLUSH FLUSH 5 1 / / /4 2 1 /16

RECESSED ASYMMETRIC MOUNT. Project. Type. Notes TECHZONE TM AND LOGIX TM COMPATIBLE

Qty: B B lm/6.9W per foot. per foot. 2B lm/15.3W per foot. 2B lm/13.

BSS610 GENERAL INFORMATION - FIXTURE HOUSING

FULL BLEED APPLICATION SHOT RENDERING

LUMINAIRE ID DIRECT OPTICS INDIRECT OPTICS LIGHT SOURCE CRI DIRECT LUMEN PACKAGES. LED - high performance LED

Skydome. 2', 3' and 4' diameter recessed direct LED with lens. Frosted acrylic diffuser provides high transmission and uniform distribution.

Cubic SurroundLite TM

PENDANT MOUNT - DIRECT/INDIRECT

PENDANT ASYMMETRIC MOUNT

BSS610 GENERAL INFORMATION - FIXTURE HOUSING

Nera. detail. fixture information. Unique aesthetic inspired by the visual void design philosophy. Luminaire sizes available in 2 x2, 3 x3 and 4 x4.

WALL LO-OUTPUT. Project. Type. Notes

DESCRIPTION PROJECT: Via 2 features our Asymmetrical Lens Optic for smooth, comfortable

Applies to both UP & DOWN. Outputs between listed min and max are available. Consult factory for other lumen packages

PENDANT MOUNT - DIRECT. Project. Type. Notes

AXLE LED PENDANT ASYMMETRIC W W W. L U M E N W E R X. C O M

Rail 4 RM4DI (Formerly Grande) LED. Pendant. Direct/Indirect

WALL MOUNT - DIRECT/INDIRECT 0.25" Glo Lens 0.25"

RECESSED T-Bar & Drywall. Project. Type. Notes. 3 7/8" 98mm

5 YEAR CONTROL SENSORS

DESCRIPTION PROJECT: Vega is an efficient architectural LED troffer with a distinctive luminous shielding that features a median textured

light J ANATOMY or CLEAN CANTILEVER Sleek square aluminum tube cantilever arms allow integral powerfeed to an electrical junction box.

CAVA CURVE LED PENDANT DIRECT/INDIRECT W W W. L U M E N W E R X. C O M

Dart. fixture information. Miniature suspended direct/indirect LED luminaire.

RECESSED T-Bar & Drywall. Project. Type. Notes AULED 14 SO

Please consult factory for other lumen packages

RECESSED T-Bar & Drywall. Project. Type. Notes 47 15/16" 47 7/8" 48" between T-Bar SIDE VIEW

PRIME PRIME 4 LED ARCHITECTURAL ROUND FLANGED DOWNLIGHT

Tove. High Performance Linear System Suspension

R6NC 6" LED Recessed Downlight: Universal New Construction Housing

AXLE LED PENDANT ASYMMETRIC W W W. L U M E N W E R X. C O M

seem 4 suspended led features dimensional data mounting information performance Narrow extruded aluminum 4 linear direct LED.

Notes: 4 3/4" 121mm. (1) Compatible with Redwood systems. See integrated controls guide for further details

PENDANT MOUNT. Project. Type. Notes

Rail 4 RM4D (Formerly Grande) LED. Pendant

Outputs between listed min and max are available. Consult factory for outputs outside of the listed range.

SURFACE MOUNT. See page 3 for DLC Approved options

Transcription:

Project Name Date Type 5-/2 (40mm) EDGE EX3I 3 3-/2 (88.4mm) Key Features 6063-T6 Extruded aluminum housing Highly reflective = white painted reflector Room side maintance for LED system 5-year limited warranty covers LED, driver and fixture UL and cul listed Approved for dry/damp location unless otherwise noted Maximum weight is 20 lbs. for a standard 4 fixture Buy American Act compliant Run lengths Available to an /8 LED Product Partner Example Part #: EX3I-N-HE-830HO-26 -AC48G-U-OL--0-W EX3I - N - - - - - - - - - - DIRECT SHIELDING INDIRECT SHIELDING CRI, CCT & OUTPUT LENGTH MOUNTING VOLTAGE DRIVER CIRCUITING BATTERY & EMERGENCY N DIRECT SHIELDING INDIRECT SHIELDING CRI, CCT & OUTPUT LENGTH FINISH FIXTURE OPTIONS N - None Shielding pg. 2 HE - High Efficiency BW - Batwing WHE - Asymmetric HEA - Ascent Shielding pg. 2 _27-2700K _30-3000K _35-3500K _40-4000K CL - Custom Lumens CW - Custom Watts Lumen Output pg. 2 - Individual Fixture - Continuous Row Length pg. 2 Example: 830HO is 8 = 80 CRI; 30 = 3000K; HO = High Output; Blank = Standard Output _ MOUNTING 2 VOLTAGE DRIVER CIRCUITING AC G_ - AC to Grid AC JB - AC to J Box AC ST - AC to Structure AC5 G_ - 5 Non-Power Canopy AC5 JB - 5 Non-Power Canopy SQ G_ - 5 Square Canopy SQ JB - 5 Square Canopy WA - Wall Mount Mounting pg. 3 U - Universal (20 thru 277V) - 20V 2-277V 3-347V Voltage pg. 3 OL - Osram (0%, 0-0v, standard) OL2 - Osram (%, 0-0v) OL3 - Osram 347v (0%, 0-0v) EE - eldoled ECOdrive (%, 0-0v) EE3 - eldoled ECOdrive (%, DALI) PL2 - Philips Xitanium (%, 0-0v) PS - Philips Xitanium (50%/00%) LH- Lutron Hi-lume (%, EcoSystem) LH3 - Lutron Hi-lume (%, 3-wire) L5 - Lutron 5-Series (5%, EcoSystem) ND - Non-Dimming Driver pg. 3 - Single Circuit M - Multi Circuit E - Emergency (entire fixture) N - Night Light (entire fixture) Circuiting pg. 4 _ BATTERY & EMERGENCY 3 FINISH FIXTURE OPTIONS CONTROLS 0 - None _PL - Philips Bodine 0W Integral _IL - Iota 0W Integral _E - Emergency Section _N - Night Light Section _L - Life Safety Section _G - Philips Bodine GTD Battery and Emergency pg. 4 W - White S - Metallic Silver BL - Textured Black BR - Bronze GR - Graphite CC - Custom Color Finish pg. 4 CC-C - Custom Color Canopy Fixture Options pg. 4 Pinnacle is able to accommodate different control solutions from different manufacturers. Consult Factory for more information. Individual fixtures come in 2, 3, 4, 5, 6, 7 & 8 lengths. Continuous row come in /8 increments 2 Specify AC length standard AC is 48 ; Specify grid: G=5/6, G9=9/6, GS=Screw Slot. Example: AC48G. 3 Enter quantity for Battery and Emergency, Example 2PL. Designed and Fabricated in Denver, CO USA pinnacle-ltg.com O: 303-322-5570

Direct Shielding N None Indirect Shielding HE BW WHE HEA High Efficiency Batwing Asymmetic Ascent Over Optic Over Optic Output Specify either 80 or 90 CRI Longer lead-time may apply for 90 CRI. Consult factory Custom Output - Lumens OR Wattage Length Individual units cannot be joined, end plates are factory installed and cannot be removed For Continuous Runs, add 3/6 (4.7mm) for each end plate or 3/8 (9.5mm) to the overall length of the row For patterns, refer to Pattern section on next page 2 3 4 5 6 7 8 _ Indiv. Fixture 24-3/8 (69.mm) Indiv. Fixture Indiv. Fixture Indiv. Fixture Indiv. Fixture Indiv. Fixture Indiv. Fixture Cont. Run Specify nominal overall row length 36-3/8 (934.8mm) to the /8 48-3/8 (228.7mm) 60-3/8 (533.5mm) 72-3/8 (838.3mm) 80 CRI = R9 9 and 90 CRI = R9 6 CL Specify CRI, CCT and desired lumens (i.e. CL835500) Specify lumens between standard offering listed below. Lumens are specified per color temp CW Specify CRI, CCT and desired wattage (i.e. CW9407) Specify watts between standard offering listed below 80 CRI Color Lumens Shielding per foot HE BW WHE HEA High Efficiency Batwing Asymmetric Ascent LPW Watts/ft LPW Watts/ft LPW Watts/ft LPW Watts/ft 830 3000K 500 9 4.2 8 4.2 93 5.4 20 4.2 830HO 3000K 750 20 6.2 5 6.5 9 8.2 20 6.3 830VHO 3000K 000 8 8.5 2 8.9 89.3 20 8.3 835 3500K 500 22 4. 2 4. 95 5.3 24 4.0 835HO 3500K 750 2 6.2 8 6.4 94 8.0 23 6. 835VHO 3500K 000 2 8.2 5 8.7 9.0 23 8. 840 4000K 500 23 3.9 22 4.7 96 5.2 25 4.0 840HO 4000K 750 24 5.9 9 7.3 95 7.9 25 6.0 840VHO 4000K 000 2 8.0 9 9.7 92 0.8 25 8.0 90 CRI 927 2700K 500 02 4.9 97 5. 78 6.4 04 4.8 927HO 2700K 750 02 7.4 97 7.7 77 9.7 04 7.2 930 3000K 500 06 4.7 86 5.8 8 6.2 07 4.7 930HO 3000K 750 06 7. 85 8.8 78 9.6 05 7.2 935 3500K 500 08 4.6 88 5.7 8 6.2 0 4.6 935HO 3500K 750 05 7. 87 8.6 80 9.4 07 7.0 940 4000K 500 07 4.7 87 5.7 80 6.2 09 4.6 940HO 4000K 750 05 7.2 86 8.7 79 9.5 06 7. 84-3/8 (243.mm) 96-3/8 (2447.9mm) Specify to the /8 LPW and watts/ft based off 48 fixture size. pg. 2

Mounting Specify cable length in ordering code (AC48G) Standard 48 adjustable cable. Specify up to 350 End plates and standard white power cord attached at factory Aircraft cable (AC) mounts on 4 (29.2mm) and 8 (2438.4mm) centers Maximum recommended movable mounting locations are 2 from end of 4 fixture and 8 from end of 8 fixture Aircraft Cable supplied with 5 (27mm) power and 2 (50.8mm) non-power canopies Canopies are painted white unless otherwise specified Canopy color specified in fixture options section Approved for dry/damp location unless otherwise noted Refer to installation instructions during installation at the job site Maximum fixture weight is 20 lbs for a standard 4 fixture AC G AC G9 AC GS AC JB AC ST AC5 G_ AC5 JB SQ G_ SQ JB MAC G MAC G9 MAC GS MAC JB MAC ST MAC5 G_ MAC5 JB MSQ G_ MSQ JB WA Aircraft Cable (5/6 ) T-Bar Aircraft Cable 9/6 T-Bar Aircraft Cable Screw Slot T-Bar Aircraft Cable Junction Box Aircraft Cable Structure Aircraft Cable 5 (27mm) Non-Power Canopy Aircraft Cable 5 (27mm) Non-Power Canopy Aircraft Cable 5 (27mm) Square Canopy Aircraft Cable 5 (27mm) Square Canopy Moveable AC (5/6 ) T-Bar Moveable AC 9/6 T-Bar Moveable AC Screw Slot T-Bar Moveable AC Junction Box Moveable AC Structure Moveable AC 5 (27mm) Non-Power Canopy Moveable AC 5 (27mm) Non-Power Canopy Moveable AC 5 (27mm) Square Canopy Moveable AC 5 (27mm) Square Canopy Wall Mount /2 WA - Wall ADA Compliant AC - Single, Adjustable Aircraft Cable MAC - Dual, Adjustable Y Aircraft Cable Voltage Some EX3I configurations will not accommodate all voltage options; consult with factory U Universal 20 volt 2 277 volt 3 347 volt Driver Standard Driver Option = OL Driver Lifetime: 50,000 hours at 25 C ambient operating conditions For more driver options, see Pinnacle Resource Guide Some EX3I configurations will not accommodate all driver options; consult with factory OL Osram Optotronic 0%, 0-0v OL2 Osram Optotronic %, 0-0v, nominal % dimming range OL3 Osram Optotronic 347v 0%, 0-0v, requires 347v option EE eldoled ECOdrive %, 0-0v Logarithmic EE3 eldoled ECOdrive %, DALI Logarithmic PL2 Philips Advance Xitanium %, 0-0v PS Philips Advance Xitanium Step Dimming 50%/00% LH Lutron Hi-lume Soft-on, Fade-to-black %, EcoSystem, LDE LH3 Lutron Hi-lume %, 3-wire, Lutron-L3DA3W L5 Lutron 5-Series 5%, EcoSystem, LDE5 ND Non-Dimming pg. 3

How to specify Circuiting, Battery and Emergency Select fixture circuiting from options below Some EX3I configurations will not accommodate all circuiting options, consult with factory Circuiting Single Circuit M Multi Circuit E Emergency Circuit only N Night Light Circuit only 2 + 3 Battery and emergency section options are available in addition to fixture circuit Select battery and emergency section options below; factory shop drawing required Some EX3I configurations will not accommodate all circuiting options, consult with factory Battery and/or Emergency If Required 0 No battery or specific emergency section required Battery Select battery section type if required, indicate total QTY. Example 2PL 90 minute battery runtime; test button is remote to fixture and requires an additional drop No battery option available for 2 lengths Entire direct fixture housing is on battery for lengths up to 5 Half of direct fixture is on battery for 6 or 8 housing lengths For more battery options available, see Pinnacle Resource Guide 0 No battery _PL Philips Bodine 0w Integral _IL Iota 0w Integral Emergency Select emergency section type if required, indicate total QTY. Example E Combine battery and emergency section ordering codes if both options are selected For Approximate Battery Lumen Output Multiply battery wattage X fixture LPW shown on Lumen Table 92.3 (LPW) x 0 (watts) = 923 battery lumen output Battery OR Emergency Ordering Examples Single circuit, 0w Integral Battery Ordering Code: -PL Emergency only, 0w Integral Battery Ordering Code: E-PL Single circuit, GTD required Ordering Code: -G _E _N _L _G Emergency circuit section Night Light circuit section Life Safety circuit section NO THROUGH WIRE Philips Bodine GTD, Generator Transfer Device section Combination Section Ordering Examples Single circuit, () 0w battery, () emergency section Ordering Code: -PLE Multi circuit, (2) 0w battery, (2) emergency sections Ordering Code: M-2PL2E Single circuit, () night light section Ordering Code: -N Finish Standard powder-coat textured white, metallic silver, textured black, graphite or bronze painted finish; consult factory for chip of standard paint finishes Selecting a fixture finish other than white may impact lumen output; consult factory for more information W S BL GR BR CC White Metallic Silver Textured Black Graphite Bronze Custom Color Fixture Options Additional options to enhance the fixture and finish of the product Specify to match housing. If not specified, canopy will be standard matte white. CC-C Custom Canopy Color pg. 4

Controls Pinnacle is able to accommodate different control solutions from different manufacturers. Consult Factory for more information. Photometrics Open Test # ITL8980 Catalog # EX3I-HE-840-4 Lumens 93 lm Watts 5.7 W Efficacy 23 LPW 757 568 378 89 Candela Distribution Vert Horizontal Angle Angle 0 23 45.0 68 90.0 90 0 0 0 0 0 95 27 28 28 28 27 00 66 67 66 67 66 05 3 3 3 2 2 0 64 65 65 63 62 5 220 29 29 27 27 20 278 276 275 272 273 25 337 333 332 329 329 30 396 390 390 386 385 35 455 448 448 444 44 40 52 504 504 50 497 45 566 557 557 554 55 50 65 606 607 604 60 55 658 649 652 648 646 60 694 686 689 686 684 65 722 77 78 76 75 70 74 740 740 739 739 75 753 753 752 752 752 80 757 757 757 757 757 Applications & Certificates Construction: 6063-T6 Extruded aluminum housing. Highly reflective die-formed white painted reflector. Shielding: Diffuse snap in lens or over optic. High Efficiency (HE) & Ascent (HEA) are snap in options. Batwing (BW) & Asymmetric (WHE) are over optics. Mounting: Aircraft cable and wall mount available. The aircraft cable mounts on 4-0 (29.2mm) and 8-0 (2438.4mm) centers. Aircraft Cable supplied with 5 (27mm) power and 2 (50.8mm) non-power canopies. Refer to installation instructions for appropriate ceiling detail. Canopies are painted white unless otherwise specified. Maximum fixture weight is 20 lbs for a standard 4 fixture. LED: 25ºC test environment. Lumen output/wattage has a margin of +/- 5%. All luminaire configurations tested in accordance with IES LM-79. Diodes tested in accordance with IES LM-80. Minimum lifetime greater than 60,000 hours. L70 = 36,200 hours and L90 = 4,00 hours. MacAdam 3-Step Ellipses. Not all products are Lighting Facts listed. For all available IES files, please visit our website at pinnacle-ltg.com. CRI, CCT & Lumen Output: Three lumen packages available. Standard, High (HO) and Very High (VHO). Custom outputs are available. Specify custom lumens or watts between standard offering listed on CRI, CCT & Output page. 80 CRI is available for 3000K, 3500K, and 4000K. 90 CRI is available for 2700K, 3000K, 3500K, and 4000K. 80 CRI = R9 9 and 90 CRI = R9 6. Voltage: Universal (U), 20 volt (), 277 volt (2) and 347 volt (3) options available. Must specify OL3 in Driver section when 347 volt (3) is selected. Some EX configurations will not accommodate all voltage options; consult with factory. Driver: Standard Driver Option is Osram 0-0V, 0% = OL. Electronic driver, Power factor is >0.9 with a THD <20%. Driver Lifetime: 50,000 hours at 25ºC ambient operating conditions. Ambient operating range: -20 F/-30 C to 07 F/42 C. For more driver options, see Pinnacle Resource Guide. Some EX configurations will not accommodate all driver options. Circuiting: Select from single circuit (), Multi circuit - For multiple circuiting and zone control, requires factory shop drawing (M), Emergency circuit (E) or Night Light circuit (N). Some EX configurations will not accommodate all circuiting options; consult with factory. Battery & Emergency: Select battery or emergency options if required. If battery or emergency option is not required, enter 0. Battery duration is 90 minutes as standard. Test button is remote to fixture. For more Battery options, see Pinnacle Resource Guide. Finish: Standard powder-coat textured white, metallic silver, graphite, textured black or bronze painted finish; consult factory for chip of standard paint finishes. Canopies painted white unless specified differently in the options section of the part number. Contact factory for additional custom color and finish options. Controls: Consult factory. Labels: UL and cul Listed. Standard and HO lumen packages are approved for dry/ damp location unless otherwise noted. Fixture Weight: Maximum fixture weight is 20 lbs for a standard 4 fixture. Buy American Act Compliant Warranty: EX LED offered with a 5-year limited warranty. Covers LED, driver and fixture. pg. 5