Operating instructions. FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE IE-CL240W-PP-REMOTE

Similar documents
Industrial Power Supplies

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

A permanent supply in any environment today and in the future High performance power supplies fit for digitisation Let s connect.

Model Number Structure

QUINT-PS/24DC/24DC/20

QUINT-PS/24DC/48DC/ 5

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

QUINT-PS/24DC/24DC/ 5/CO

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

QUINT-PS/24DC/24DC/10

Technical Documentation

720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet

DC/DC converters - MINI-PS DC/ 5-15DC/

DEVICE STATE/BYPASSED FAILURE OVERLOAD

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12

QUINT-PS/48DC/24DC/5. DC/DC converter with SFB technology, primaryswitched, input: 48 V DC, output: 24 V DC, output current: 5 A.

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Operating instructions Flow monitors SI5000 SI / / 2007

QUINT-PS/24DC/24DC/10/CO

Solid State Relays contactor with Integrated Fuse Type RGC1F

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

Operating Instructions for Roll-Up Door Operators / MDF

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Appendix: Safety and application notes for... 15

BMW i. Freude am Fahren. Wallbox PURE. Installation instruction

EPS/ELA-Series User Manual EPS/ELA 250W

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Electronic Ignition Module

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

DATAFLEX 110/... Torque Measuring Shaft Operating/Assembly instructions DATAFLEX. Torque measuring shaft type 110/

MANUAL. Single charger

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

G3PE-Single-phase. Solid State Relays for Heaters

Electronic Ballast EVG 2000-T

RVS-AX Instruction Manual

Technical Manual Electrical Power Supply System T4002

INSERTION flow sensor for continuous flow measurement

Insertion magnetic inductive flowmeter

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

Primary switch mode power supplies CP range

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

SOLSTART Instruction Manual

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

NOTE Please read this Operating Manual carefully before first using the device and strictly adhere to the instructions!

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

PURE SINE WAVE DC TO AC POWER INVERTER

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

L Charger. Instruction manual

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

PHOENIX CONTACT - 01/2008

Dimensions WxHxD [mm] Weight [kg]

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

MINI MCR-SL-UI-UI(-SP)(-NC)

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

D R C- 4 0 s e r i e s

Uninterruptible power supplies (UPS)

DATAFLEX 42/1000 Torque Measuring Shaft Operating/Assembly instructions DATAFLEX

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector

Lexium integrated drives

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

DALI 650mA LED Driver

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

DeltaSol AX. RESOL DeltaSol AX * * Mounting Connection Operation Application examples. manual

1.1 Caution Statements

IBC control. MicroMax MANUAL. With adjustable boost function and threshold value. Since Set of EMC-glands as an option

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices)

DIN EN UL 508 / CSA 3RF A A 0 2

DC Master 24/ A

Tina 4A Connection block

Inductive conductivity meter

Design Guide. VLT Soft Start Controller MCD 100

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

55185 EMERGENCY PACK FOR LED PANEL TECHNICAL DATA SHEET

Lexium integrated drives

DC (on) LED Signal. Multiple output connector for easy wiring

General technical data: CONTACTOR, AC-3, 18.5KW/400V, 1NO+1NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL. product brand name

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

J TS 7090 Thyristor power switch

Solid State Relays, 3-phase

c-go 24V/6A 24V/8A 24V/12A

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

Transcription:

Operating instructions FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE 1547440000 IE-CL240W-PP-REMOTE 1547450000

Technical service: freecon.contactless@weidmueller.com Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 32758 Detmold, Germany T +49 (0) 5231 14-0 F +49 (0) 5231 14-292083 info@weidmueller.com www.weidmueller.com Copyright 2016 Weidmüller Interface GmbH & Co. KG 2 2002150000/03/06.2017

Contents 1 Safety...4 1.1 General safety notifications...4 1.2 Intended use...4 1.3 Conformity with EU directives...4 2 Product description...5 2.1 Device description...5 2.2 Functional description...5 2.3 Usage possibilities...6 2.4 Dimensions...7 2.5 Included in delivery...7 2.6 Accessories...7 2.7 Type plate...7 3 Installation and connections...8 3.1 Installation...8 3.2 Power connection...8 3.3 Earthing...9 3.4 Pin assignment for power connector...10 3.5 Switching functions and status alerts...10 4 Status indicators and maintenance...13 4.1 LED indicators...13 4.2 Maintenance...14 5 Technical data...15 2002150000/03/06.2017 3

1 Safety 1.1 General safety notifications Work on the FreeCon product may only be performed by qualified electricians with the support of trained persons. As a result of their professional training and experience, an electrician is qualified to perform the necessary work and identify any potential hazards. A qualified electrician must dimension the cables. Before any work is carried out on the FreeCon product the power supply must be switched off and secured against being switched on again. The surface temperature of the FreeCon products can exceed 70 C depending on application. To avoid unintentional touch, install a mechanical barrier or a conspicuous security advice. A power supply with secure isolation must be used to power the base. If faults on a FreeCon product cannot be rectified using the recommended measures, the product concerned must be sent to Weidmüller. Weidmüller assumes no guarantee if the device is tampered with! During operation, steps must be taken to ensure that no metallic objects can enter the air gap between the base and remote. 1.2 Intended use The FreeCon Contactless power system is designed to provide a contactless electromagnetic connection in an industrial environment. The housings comply with IP65 protection. Any other usage is not permitted and may lead to accidents or destruction of the device. The observance of the supplied documentation is part of the intended use. 1.3 Conformity with EU directives The product complies with the EMC directive 2004/108/EC. Weidmüller will provide the CE Declaration of Conformity upon request. 4 2002150000/03/06.2017

2 Product description 2.1 Device description The FreeCon Contactless power system (FCP system) consists of a base and at least one remote. 1 2 3 4 5 6 7 8 3 4 5 6 7 8 Device overview 1 Base (transmitter) 2 Remote (receiver) 3 Marker (stuck on) 4 PushPull powerport (for PROFINET-compliant connectors) 5 Status LED 6 Earthing connection 7 Cooling fins 8 Type plate FCP systems are used wherever conventional plug-in connectors are subject to substantial wear and tear (e.g. through frequent plugging cycles, contact erosion, bent contacts), as well as with applications where the energy supply is to be automated. 2.2 Functional description The base with a connected power source transmits electric power to the remote to which a load is connected. The transmission is contactless even over an air gap of max. 5 mm. The two FCP elements can be brought closer together axially, vertically and horizontally. Power can be transmitted even during rotation (rotational axis = centre-point axis). During usage with a PLC, the voltage on the remote can be switched on and off from the base. 2002150000/03/06.2017 5

2.3 Usage possibilities The sum of air gap and centre offset must not exceed 5 mm! max. 5 mm Linear approximation, frontal Linear approximation, side max. 5 Rotating approximation, frontal The best efficiency is achieved with as small an air gap as possible and minimal centre offset. Maximum permissible distance or offset 6 2002150000/03/06.2017

2.4 Dimensions M4 22 mm 19.5 mm 47 mm 100 mm 44 mm 100 mm Dimensions 2.5 Included in delivery IE-CL240W-PP-BASE (Order No. 1547440000) Base with protective cap for transporting on PushPull Powerport, operating instructions IE-CL240W-PP-REMOTE (Order No. 1547450000) Remote with snap ferrite and protective cap for transporting on PushPull Powerport 2.6 Accessories Plug-in connector IE-PS-VAPM-5P-2.5 (Order No. 2465440000) Marker ESG 6/17 K MC NE WS (Order No. 1880120000) 2.7 Type plate Type: FreeCon Contactless Power Name: IE-CL240W-PP-BASE Art.No.: 1547440000 HW-Rev.: 1.1 Ser.no.: AQ3Q79PB4700000 LED: GN Remote OK GN blk NO Remote Output: 21,6-26,4 V DC; max. 10 A RD DC in NOK, Overld. Temp.: -20 C 45 C RD blk Overheating Weidmüller Interface GmbH&Co. KG Klingenbergstr. 16 D-32758 Detmold Type: FreeCon Contactless Power Name: IE-CL240W-PP-REMOTE Art.No.: 1547450000 HW-Rev.: 1.0 Ser.no.: Output: Temp.: AQ3Q79PB4700000 19,2-28,8 V DC; max. 10 A @ 20 C -20 C 45 C Made in Germany LED: GN RD Made in Germany DC OK DC NOK Weidmüller Interface GmbH&Co. KG Klingenbergstr. 16 D-32758 Detmold Type plates for base and remote 2002150000/03/06.2017 7

3 Installation and connections WARNING Possible danger to life! Disconnect the power supply and secure it against being switched on again. ATTENTION Material damage possible! If metallic objects get into the air gap between the base and remote during operation, this may cause heating and damage to the plastic cover. Select the installation site so that no metallic objects can get into the air gap. 3.1 Installation Each FCP element can be secured using one of the three long sides with no connections. Secure each element using four M4 bolts (hole dimensions see below, thread depth of the holes 8 mm). M4 Hole dimensions 44 mm 22 mm The best efficiency is achieved with as small an air gap as possible and low centre offset. Depending on the application (power/air gap/ambient temperature) the installation site must be designed in such a way that the heat produced is dissipated (e.g. installing on a metal sheet, heat sink or similar). 3.2 Power connection ATTENTION Material damage possible! If the power exceeds the maximum permissible value, this may cause the wiring to overheat, which will cause serious damage to your devices and equipment. Calculate the maximum current generated in the individual cables. Note all relevant regulations governing the maximum permissible current for each wire cross-section. Take the following into account during installation: Use a power supply with secure isolation to power the base! All cables must have a sufficient core cross-section, which depends on the current demand and the cable lengths. We recommend using cables with a cross-section of at least 1 mm². 8 2002150000/03/06.2017

The plug-in connector IE-PS-VAPM-5P-2.5 (accessories) is designed for the range 0.75... 2.5 mm². 3.3 Earthing As an option, the FCP system can be earthed via an M4 bolt with a toothed washer using the particular blind hole on the housing side with the power connection. IE-PS-VAPM-5P-2.5 connector Attach the included snap ferrite on the remote cable at a distance of approximately 10 cm from the connecting plug. 10 cm Assembled snap ferrite 2002150000/03/06.2017 9

3.4 Pin assignment for power connector Pin Base Remote 1 L1 24 V DC (US1+) L1 24 V DC (US1+) 2 N1 0 V DC (US1-) N1 0 V DC (US1-) 3 CMD; command from PLC (optional) 4 STAT; status to PLC (optional) 5 Functional earth (FE) Functional earth (FE) Base Remote 24 V DC 0 V DC INPUT DC 1 2 1 2 OUTPUT DC 24 V DC 0 V DC PLC optional CMD STAT 3 4 3 4 FE 5 5 FE Block diagram for contactless power transmission 3.5 Switching functions and status alerts In order to disable the transmission, Pin 3 must be set to 0 V. For this reason, either an N-switching module or a relay module must be used when operating with a PLC. P-switching modules must not be used! 10 2002150000/03/06.2017

Pin 3: Switching function Function Pin 3 (Base) Description Comment CMD-1 24 V Power transmission enabled if a valid remote is detected. This state also applies if Pin 4 is not connected. CMD-2 0 V Power transmission disabled Pin must be set from external to Low. (Open collector) Pin 4: Status alerts Function Pin 4 (Base) Description Comment STAT-1 24 V Valid remote detected, power transmission is enabled STAT-2 24 V 10/30 ms puls Valid remote detected, power transmission is disabled STAT-3 0 V Invalid remote, power transmission is disabled Open Collector output If Pin 3 and 4 of the base are not assigned, the power is switched through as soon as the remote is in the range <5 mm to the base. 2002150000/03/06.2017 11

The following diagram shows the signals of Pins 3 and 4 if these are interconnected and triggered, as well as the output voltage of the remote. PLC Pin 4 STAT Base Pin 3 CMD Base 24 V 0 V 24 V 0 V STAT-3 STAT-2 STAT-1 STAT-2 STAT-3 CMD -2 CMD -1 CMD -2 Output Remote Pin 2 24 V DC Remote 24 V 0 V Signal path and output characteristics 12 2002150000/03/06.2017

4 Status indicators and maintenance 4.1 LED indicators There is a status LED on each FCP element next to the PushPull Powerport. Status LED Status LED on the base Status LED Meaning Recommended action Flashes green Flashes green intermittently Lights up green Input voltage OK, no remote coupled (STAT-3) Remote is repeatedly coupled and decoupled (pulses) Input voltage OK, remote coupled (STAT-1) Reduce centre offset between base and remote to <5 mm Lights up red Input voltage not OK or overload Check input voltage Check load for short-circuit Flashes red Over-temperature (>85 C) Improve heat dissipation or incorporate ventilation Reduce connected load Status LED on the remote Status LED Meaning Recommended action Lights up green Output voltage OK Lights up red Output voltage not OK, current limiting enabled Reduce connected load 2002150000/03/06.2017 13

4.2 Maintenance Clean the surfaces of the FCP elements with a dry or moist cloth. Do not use cleaning agents that contain acetone. 14 2002150000/03/06.2017

5 Technical data Electrical data Input voltage 21.6 26.4 V DC (24 V DC ±10 %) Output voltage 19.2 28.8 V DC (24 V DC ±20 %) No-load current, base Power connection Reverse polarity protection Overload protection Yes (>12 A) Max. load current, remote Max. power Turn-om time, base Coupling time, remote Approx. 40 ma (without remote) Approx. 260 ma (remote without load) PushPull Power plug-in connector (as per PROFINET specification) Yes 10 A (12 A for 50 ms); consider derating, see Annex 240 W; consider derating, see Annex 1 s < 500 ms Efficiency Max. 91 % Operating frequency Mechanical specifications Housing main material Protection degree Dimensions Weight Type of mounting Air gap Centre offset Approx. 55 khz Diecast zinc, painted, PBT plastic IP65 as per DIN EN 100 mm x 100 (108) mm x 47 mm 1,020 g (per FCP element) Four M4 bolts (blind hole depth 8 mm) 0 5 mm; consider derating, see Annex ± 5 mm Angle offset max. 5 Coupling range Decoupling range Environmental conditions Ambient temperature (operational) 5...7 mm 10...18 mm Storage temperature -40 +85 C Relative humidity -20 +45 C; consider derating, see Annex 5...95 %, no condensation 2002150000/03/06.2017 15

Standards / approvals UL In preparation EMC / Emissions EN 61000-6-4, Class A (09/2011) EMC / Electrostatic discharge immunity EN 61000-4-2, Criteria B (12/2009) EMC / Radiated, radio-frequency, electromagnetic field immunity EN 61000-4-3, Criteria A (04/2011) EMC / Electrical fast transient/burst immunity EN 61000-4-4, Criteria A (04/2013) EMC / Surge immunity EN 61000-4-5, Criteria B (06/2007) EMC / Immunity to conducted disturbances EN 61000-4-6, Criteria A (08/2014) EMC / Immunity to magnetic fields EN 61000-4-8, Criteria A (11/2010) Vibrations DIN EN 60068-2-6 (10/2008) Shock DIN EN 60068-2-27 (02/2010) CCC Products with an operating voltage <24 V are exempt from approval. 16 2002150000/03/06.2017

Annex Derating The derating curve shows the dependence of the current strength on the air gap and ambient temperature if the centre offset is 0 mm. With a centre offset >0 mm the permissible air gap or the transmissible power is reduced. The derating figures only apply if a heat sink with 1.5 K/W or better is used during operation or comparable heat dissipation is ensured. Air gap [mm] 5 4 3 2 A 4 A 6 A 2 8 A 1 10 A 0-20 -10 0 10 20 30 40 50 Ambient temperature [ C] Current strength depends on air gap and ambient temperature 2002150000/03/06.2017 17

Dependence of efficiency on air gap or load current Efficiency [%] 100 90 80 70 60 50 40 30 20 10 0 6 A load current 2 A 6 load current 0,5 2,0 3,5 5,0 Air gap [mm] Efficiency dependent on air gap (24 V DC, 15 C) Efficiency [%] 100 90 80 70 60 50 40 30 20 10 0 Air gap 0.5 mm Air gap 3.5 mm 2 4 6 8 10 Load current [A] Efficiency dependent on load current (24 V DC, 15 C) 18 2002150000/03/06.2017

2002150000/03/06.2017 19

Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 32758 Detmold, Germany T +49 (0) 5231 14-0 F +49 (0) 5231 14-292083 info@weidmueller.com www.weidmueller.com 2002150000/03/06.2017