Nominal sizes 08 to 10, special cavities

Similar documents
4/3-4/2 Proportional directional valves L5080 solenoid (LC04P) operated (for open loop control) L5080 (LC04P)

3/2 ways/positions flow diverters L (VS91-VS92-VS95)

6/2 ways/positions flow diverters L (VS151-VS152-VS155)

6/2 ways/positions flow diverters L (VS120-VS125-VS129)

4/3, 4/2 proportional directional valves solenoid operated (for open loop control)

Intermediate elements with flow regulator on P line

6/2 ways/positions flow diverters

4/3-4/2 Directional valve elements LF1_1 (LC1F-Z)

6/2 ways/positions flow diverters

6/2 ways/positions flow diverters

Directional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces:

Stand alone 4/3, 4/2 direct acting directional valve LF2_1 (LC2F-DZ)

3/2 ways/positions flow diverters

6 to14/2 ways/positions bankable flow diverters flangeable

6 to14/2 ways/positions bankable flow diverters flangeable

4/3-4/2 Directional valve elements B8_0A with or without (EDB-A) secondary relief valves, with or without LS connections B8_0A (EDB-A)

6 to14/2 ways/positions bankable flow diverters flangeable

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

6 to 12/2 ways/positions bankable flow diverters flangeable

Stand alone 4/3, 4/2 solenoid operated directional valve

6 to 12/2 ways/positions bankable flow diverters flangeable

4/3-4/2 Directional valve with solenoid actuation

4/3 and 4/2 Proportional directional valve elements L8580 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING

5-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow, for two pumps systems

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

4/3 and 4/2 Proportional directional valve elements L8581 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING

4/3 and 4/2 on-off directional valve elements L8511 with flow (EDC-DZ) sharing control (LUDV concept) L8511 (EDC-DZ)

4/3 Proportional directional valve elements L85P5 with proportional (EDC-IP) hydraulic control and flow sharing control (LUDV concept) PATENT PENDING

3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

4/3 and 4/2 on-off directional valve elements D8_5 with or (EDD-XZ) without secondary relief valves and with or without LS connections D8_5 (EDD-XZ)

4/2 Directional valve elements with or without secondary relief valves, with or without LS connections, and with 2/2 solenoid cartridge valve

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

B8_58 (EDBZ-VEI) RE Edition: Replaces:

Modular directional valves RE 00159/10.09 Replaces: 01.06

4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

Coils - Connectors. Coils Connectors. Summary. RE /06.17 Replaces: RE / Description

Insert Valves Flow control

Coils - Connectors. Coils Connectors. Summary. RE /07.13 Replaces: RE / Description. Connectors Connector IP

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

2-way flow control valve

Proportional pressure relief valve, directly operated, rising characteristic curve

LUDV control block of sandwich plate design

Pressure relief valve, pilot operated

Accumulator shut-off block. Type 0532VAW. Contents. Features. RE Edition: Replaces: 07.10

Throttle and throttle check valve

Hydraulic inch power brake valve LT 31

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

3/2 directional spool valve, direct operated with solenoid actuation

Proportional pressure reducing valve, pilot operated

Proportional flow control valve, with integrated pressure compensator

Axial Piston Variable Pump A2VK

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

Supply pressure compensator, direct operated

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04

Pressure reducing valve, pilot operated

Proportional pressure relief valve, pilot operated

Proportional flow control valve, 2-way version

Proportional pressure reducing valve, pilot operated, with inductive position transducer

Directional valves Pneumatically operated Series 740. Brochure

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

Proportional pressure relief valve with linear curve (Lvdt AC/AC)

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

2/2 directional seat valve, direct operated with solenoid actuation

Flow sharing control block in mono block / sandwich plate design M6-15

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Flow sharing control block in mono block / sandwich plate design M6-22

Proportional pressure reducing valve, 3-way variant, pilot operated

Proportional pressure reducing valve, pilot operated

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type DRE05SK

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03

Check valve, pilot operated

Proportional pressure reducing valve, pilot operated

Axial Piston Fixed Pump A17FNO Series 10

2-way proportional throttle valve for block installation

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

Universal Through Drive

Proportional pressure reducing valve, pilot operated. Type DRE(M) and DRE(M)E. Features. Contents. RE Edition: Replaces: 11.

ELECTRIC CARTRIDGES ELECTRO-PROPORTIONAL VALVES

Central Hydraulics Valve for Tractors with Priority Function for Steering, Trailer Brake and Pilot Oil Valve

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

Load holding / Motion control valves. Product Selection Guide. Summary. Page. Page. Flow regulators Pilot operated check valves 2

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

Pressure relief valve, direct operated. Type DBD..K. Contents. Features. RE Edition:

Directional spool and seat valves with electrical actuation and M12x1 plug-in connection

Throttle and throttle check valve

Proportional pressure relief valve

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Pressure relief valve, pilot operated

Proportional Flow-Control Cartridges, Size 5

Servo solenoid valves with on-board electronics (OBE)

Pressure relief valve, pilot operated

Filter cooler unit with inline filter according to DIN Type ABUKG. Contents. Features. RE Edition: Replaces: 50126

Transcription:

Nominal sizes 08 to 10, special cavities RE 18301-91 Edition: 05.2016 Replaces: 07.2012 Contents Relief, direct acting guided poppet type Common cavity, Size 10 2 Relief, direct acting guided poppet type Special cavity, Size 019-E 6 Proportional valves non compensated flow regulators Common cavity, Size 10 8 Coils - Connectors 12 RE 18301-91/05.2016, Bosch Rexroth Oil Control S.p.A.

2 Nominal sizes 08 to 10, special cavities Relief, direct acting guided poppet type Common cavity, Size 10 Dimensions [mm (inches)] Relief, direct acting guided poppet type Common cavity, Size 10 VMD1.040 0T.M1.03 - X - 99 - Z Description Flow is blocked from 1 to 2 until pressure increases to meet the selected valve setting, lifting the poppet from its seat and allowing relief flow through port 2 to tank. Pressure at port 2 is additive to the relief setting of the valve. The unique Bosch Rexroth Oil Control poppet design provides enhanced stability at all flows and pressures. Performance Technical Data General Max pressure bar (psi) 350 (5000) Max flow l/min (gpm) 50 (13) Installation torque Nm (ft-lb) 55-65 (41-48) Cavity CA-10A-2N Weight kg (lbs) 0.17 (0.38) Fluid temperature range C ( F) between -30 (-22) and +100 (+212) Preferred types Type 0TM103039910000 0TM103039920000 0TM103039935000 Material number R901099401 R901099402 R901114696 Bosch Rexroth Oil Control S.p.A., RE 18301-91/05.2016

Dimensions [mm (inches)] Nominal sizes 08 to 10, special cavities 05.2016 Relief, direct acting guided poppet type Common cavity, Size 10 3 Dimensions Leakproof hex socket screw Ordering code 0T.M1.03 X 99 Z Relief, direct acting guided poppet type SPRINGS Adjustments Adj. press. range bar (psi) Press. increase bar/turn (psi/turn) Std. setting press. bar (psi) (Q=5 l/min) = 03 Leakproof hex. socket screw = 10 25-120 (350-1750) 16.5 (239) 100 (1450) = 20 40-200 (580-2900) 26.5 (384) 180 (2600) Common cavity Size 10 = 35 200-350 (2900-5000) 51 (740) 350 (5000) RE 18301-91/05.2016, Bosch Rexroth Oil Control S.p.A.

4 Nominal sizes 08 to 10, special cavities Relief, direct acting guided poppet type Common cavity, Size 10 Dimensions [mm (inches)] Relief, direct acting guided poppet type Common cavity, Size 10 VMD1.070 0T.M1.04 - X - 99 - Z Description Flow is blocked from 1 to 2 until pressure increases to meet the selected valve setting, lifting the poppet from its seat and allowing relief flow through port 2 to tank. Pressure at port 2 is additive to the relief setting of the valve. The unique Bosch Rexroth Oil Control poppet design provides enhanced stability at all flows and pressures. Performance Technical Data General Max pressure bar (psi) 260 (3800) Max flow l/min (gpm) 70 (19) Installation torque Nm (ft-lb) 55-65 (41-48) Cavity CA-10A-2N Weight kg (lbs) 0.18 (0.4) Fluid temperature range C ( F) between -30 (-22) and +100 (+212) Preferred types Type 0TM104039905000 0TM104039910000 0TM104039920000 0TM104039935000 Material number R901099575 R901099604 R901116269 R901099642 Bosch Rexroth Oil Control S.p.A., RE 18301-91/05.2016

Dimensions [mm (inches)] Nominal sizes 08 to 10, special cavities 05.2016 Relief, direct acting guided poppet type Common cavity, Size 10 5 Dimensions Leakproof hex socket screw Ordering code 0T.M1.04 X 99 Z Relief, direct acting guided poppet type SPRINGS Adjustments Adj. press. range bar (psi) Press. increase bar/turn (psi/turn) Std. setting press. bar (psi) (Q=5 l/min) = 03 Leakproof hex. socket screw = 05 10-60 (145-870) 10 (145) 50 (725) = 10 40-110 (580-1600) 17 (247) 100 (1450) Common cavity Size 10 = 20 110-220 (1600-3200) 31.5 (457) 200 (2900) = 35 220-260 (3200-3800) 37 (537) 250 (3600) RE 18301-91/05.2016, Bosch Rexroth Oil Control S.p.A.

6 Nominal sizes 08 to 10, special cavities Relief, direct acting guided poppet type Special cavity, Size 019-E Dimensions [mm (inches)] Relief, direct acting guided poppet type Special cavity, Size 019-E VMD1.025 0T.M1.02 - X - 99 - Z Description Flow is blocked from 1 to 2 until pressure increases to meet the selected valve setting, lifting the poppet from its seat and allowing relief flow through port 2 to tank. Pressure at port 2 is additive to the relief setting of the valve. The unique Bosch Rexroth Oil Control poppet design provides enhanced stability at all flows and pressures. Performance Technical Data General Max pressure bar (psi) 350 (5000) Max flow l/min (gpm) 35 (9) Installation torque Nm (ft-lb) 40-45 (30-33) Special Cavity 019-E Weight kg (lbs) 0.13 (0.29) Fluid temperature range C ( F) between -30 (-22) and +100 (+212) Preferred types Type 0TM102039910000 0TM102039920000 0TM102039935000 Material number R901091925 R901091920 Bosch Rexroth Oil Control S.p.A., RE 18301-91/05.2016

Dimensions [mm (inches)] Nominal sizes 08 to 10, special cavities 05.2016 Relief, direct acting guided poppet type Special cavity, Size 019-E 7 Dimensions Leakproof hex socket screw Ordering code 0T.M1.02 X 99 Z Relief, direct acting guided poppet type SPRINGS Adjustments Adj. press. range bar (psi) Press. increase bar/turn (psi/turn) Std. setting press. bar (psi) (Q=5 l/min) = 03 Leakproof hex. socket screw = 10 25-120 (350-1750) 16.5 (239) 100 (1450) = 20 40-200 (580-2900) 26.5 (384) 180 (2600) Special cavity Size 019-E = 35 200-350 (2900-5000) 51 (740) 350 (5000) RE 18301-91/05.2016, Bosch Rexroth Oil Control S.p.A.

8 Nominal sizes 08 to 10, special cavities Proportional valves non compensated flow regulators Common cavity, Size 10 Dimensions [mm (inches)] Proportional valves non compensated flow regulators Common cavity, Size 10 VEP-5A-2Q-09-NC-2F OD.92 - K - 77 - Y - 01 K=03 K=05 Description Flow is blocked from 1 to 2 until pressure increases to meet the selected valve setting, lifting the poppet from its seat and allowing relief flow through port 2 to tank. Pressure at port 2 is additive to the relief setting of the valve. The unique Bosch Rexroth Oil Control poppet design provides enhanced stability at all flows and pressures. Performance Technical Data General I max(±15%) for 12 V DC coil A 2 I min(±15%) for 12 V DC coil A 0.9 Recommended PWM frequency Hz 150-180 Internal leakage at 210 bar (3000 psi) with 46 cst oil cm 3 /min (in 3 /min) max 180 (11) Cavity CA-10A-3N Coil S5 (must be ordered separately) Minimum voltage required 90% of nominal value Testing conditions - Seals Internal and external seals are designed for applications that operate within the fluid temperature range Weight kg (lbs) 0.31 (0.68) Fluid temperature range C ( F) between -30 (-22) and +100 (+212) Ambient temperature C ( F) -30 (86) and +60 (+140) Mounting position unrestricted N.B. It is recommended to bleed air carefully before operation. Preferred types Type OD920377030100 OD920377040100 OD920577030100 OD920577040100 Material number R934001518 R934001521 R934001524 R934001526 Bosch Rexroth Oil Control S.p.A., RE 18301-91/05.2016

Dimensions [mm (inches)] Nominal sizes 08 to 10, special cavities 05.2016 Proportional valves non compensated flow regulators Common cavity, Size 10 9 Dimensions Standard Knob style manual override Ordering code OD.92 K 77 Y 01 Proportional valves non compensated flow regulators Hydraulic scheme = 03 see scheme A = 05 see scheme B Ordering options = 03 Standard = 04 knob style manual override Common cavity Size 10 RE 18301-91/05.2016, Bosch Rexroth Oil Control S.p.A.

10 Nominal sizes 08 to 10, special cavities Proportional valves non compensated flow regulators Common cavity, Size 10 Dimensions [mm (inches)] Proportional valves non compensated flow regulators Common cavity, Size 10 VEP-5A-2Q-09-NC-6F OD.92 - K - 77 - Y - 03 K=03 K=05 Description Flow is blocked from 1 to 2 until pressure increases to meet the selected valve setting, lifting the poppet from its seat and allowing relief flow through port 2 to tank. Pressure at port 2 is additive to the relief setting of the valve. The unique Bosch Rexroth Oil Control poppet design provides enhanced stability at all flows and pressures. Performance Technical Data General Operating pressure bar (psi) 210 (3000) Rated flow l/min (gpm) 40 (11) I max(±15%) for 12 V DC coil A 2 I min(±15%) for 12 V DC coil A 0.8 Recommended PWM frequency Hz 150-180 Internal leakage at 210 bar (3000 psi) with 46 cst oil cm 3 /min (in 3 /min) max 180 (11) Cavity CA-10A-3N Coil S5 (must be ordered separately) Minimum voltage required 90% of nominal value Testing conditions - Seals Internal and external seals are designed for applications that operate within the fluid temperature range Weight kg (lbs) 0.31 (0.68) Fluid temperature range C ( F) between -30 (-22) and +100 (+212) Ambient temperature C ( F) -30 (86) and +60 (+140) Mounting position unrestricted N.B. It is recommended to bleed air carefully before operation. Preferred types Type OD920377030300 OD920377040300 OD920577030300 OD920577040300 Material number R934001520 R934001522 R934001525 R934001528 Bosch Rexroth Oil Control S.p.A., RE 18301-91/05.2016

Dimensions [mm (inches)] Nominal sizes 08 to 10, special cavities 05.2016 Proportional valves non compensated flow regulators Common cavity, Size 10 11 Dimensions Standard Knob style manual override Ordering code OD.92 K 77 Y 03 Proportional valves non compensated flow regulators Hydraulic scheme = 03 see scheme A = 05 see scheme B Ordering options = 03 Standard = 04 knob style manual override Common cavity Size 10 RE 18301-91/05.2016, Bosch Rexroth Oil Control S.p.A.

12 Nominal sizes 08 to 10, special cavities Dimensions [mm (inches)] Coils - Connectors COIL S5 - CLASS H OD.02.09.01.30 - Z - 01 Technical Data General Weight kg (lbs) 0.47 kg (1.04 lbs) Heat insulation Class F C ( F) +180 (356 ) Ambient temperature C ( F) -30 (86) and +60 (+140) Inlet voltage fluctuations must not exceed ±10% of nominal voltage to obtain correct operation and long life coils. Ordering Code Z Voltage V Resistance Ohm (±7%) Nominal Ta = 20-25 C (68-77 F) Power W Cold coil Current A Cold coil Hot coil T C ( F) 1 hour energized at Ta=20-25 C (68-77 F) Nominal voltage OB 12 DC 6.2 23 1.92 1.41 92-96 OC 24 DC 24.9 23 0.96 0.71 (198-205) Bosch Rexroth Oil Control S.p.A. Oleodinamica LC Division Via Artigianale Sedrio, 12 42030 Vezzano sul Crostolo Reggio Emilia - Italy Tel. +39 0522 601 801 Fax +39 0522 606 226 / 601 802 compact-hydraulics-cdv@boschrexroth.com www.boschrexroth.com/compacthydraulics This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth Oil Control S.p.a.. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging. Subject to change. Bosch Rexroth Oil Control S.p.A., RE 18301-91/05.2016