ompany Information 1926 SSP ittings orp. is founded in leveland, Ohio, U.S.. SSP begins as a contract manufacturer of screw machine products in brass and carbon steel to general industry. 1940s World War II shifts the company s focus to production of fittings for tubing, pipe, and hose. ollowing the war, SSP s customers are able to satisfy their own requirements without relying on outside companies for production. SSP contracts. 1970s New ocus. By the early 1970s, SSP embarks on a market & manufacturing driven strategy of producing quality fittings from difficult-to-machine alloys. he performance requirements of customers utilizing these materials in industries as diverse as marine, defense, offshore oil, and aerospace, drive SSP to establish both conformance quality standards, and service levels, which are significantly ahead of general industry at the time. 1980s he Works. hings are really happening for SSP. he company establishes a product line and distribution channel for hydraulic fittings, which require significant investments in a new, state-of-the-art facility south of leveland. SSP builds a 165,000 sq. ft. facility to house our vertically-integrated Works, including, by now, tool & die design & production, custom closed-die forging, machining, finishing operations, assembly and test. With over 200 work centers, SSP s winsburg Works is among the largest single-site facilities in the entire industry. 1990s Market xpansion. In response to continued customer requests for alternative product offerings in the Instrumentation fitting and valve marketplace, strategic plans were developed to design, manufacture and distribute merican-manufactured, tube fittings and valves as direct alternatives to the registered trademark brands of Swagelok, Parker PI and oke yrolok. RI SSP introduces fully-validated design alternatives under brand names uolok,, riplok tube fittings; ruit pipe, weld, hose and adapter fittings; and lolok valves. 2000 he New orce. SSP becomes the fastest-growing specialty fitting manufacturer in the United States selling through independent distributors. With an established, efficient US distribution network in place, SSP expands into global markets with additional fabricated products including tubular and hose assemblies. Significant continued investments allow SSP to renew our commitment to providing customers with best value through time-based competitive advantage, maximum objectivity in our product recommendations based on mastery over an ever-increasing range of fluid system fitting designs, and a commitment to integrity and honesty in our business relationships. 2 Swagelok is a registered trademark of the Swagelok o. PI is a registered trademark of Parker annifin o. -LOK is a registered trademark of Parker annifin o. uolok,, riplok, rufit and lolok are registered trademarks of SSP ittings orp. NOI: his publication is an uncontrolled copy of a controlled document. SSP has made every reasonable effort to insure the accuracy of the information contained in this publication, and is not to be held liable in any manner for any mistakes, omissions, typographical and/or printing errors.
ow to Order IS 4 M 6 Material esignator IS=Steel SSP Brand esignator =uolok U= ube hart #1 ype of ube itting hart #2 2nd nd connection is required for a reduced size tube or a differing type of end connection such as MNP or NP. hart #1 R #1 Size esignators ube or MNP, Size esignator NP Size* 2 1/8 4 1/4 6 3/8 8 1/2 12 3/4 16 1 *ube is expressed in sixteenths of an inch NOS: ll onfigurations: Only one size indicator is necessary when all of the connections are the same type and size. Straights and lbows: Specify the largest tube end first followed by the smaller tube end or differing type of connection. ees: escribed by first sizing the run (1 to 2) and then the branch (3). R #2 ype of ube itting M M MB MR M U U U BU RU R N B escription of uolok/ ube itting ypes Male onnector Male lbow Male Branch ee Male Run ee Male dapter emale onnector emale lbow emale dapter Union Union lbow Union ee Bulkhead Union Reducing Union Reducer/dapter OMPONNS Nut Back errule (uolok Only) ront errule (uolok Only) errule ( Only) 1 2 3 3
uolok Steel ube ittings MRILS SL uolok straight configuration tube fittings are machined from cold-finished bar stock in accordance with SM -108. Shaped bodies are machined from close-grained steel forgings with material in accordance with SM -108 and SM -576. PLIN & OIN uolok fittings are plated for corrosion resistance with zinc. Other chemically-inert platings may be utilized to assist installation. SIN uolok tube fittings are designed and manufactured to provide a reliable, leak-proof connection in instrumentation and process tubing systems. uolok tube fittings consist of four precision-machined components: 1) Body 2) ront errule 3) Back errule (316 SS) 4) Nut he double ferrule design, with the staged sequential swaging action of the ferrules during make-up, compensates for the variations in tubing materials, hardness, and thickness of the tube wall to provide leak-tight connections in an extensive range of applications. dditionally, in fulfillment of the design criteria, all uolok components are manufactured with stringent tolerances and superior surface finishes under rigorous quality control standards to assure the optimum performance of each component. OPRION hrough the critical interaction of precision-machined fitting components with the process tube, a leaktight seal is achieved. he simple geometric rotation of the uolok nut provides the axial thrust necessary to swage the ferrules to the outside diameter of the tube. o eliminate any potential stress on an existing system, the tube fittings have been designed to not transmit installation torque from the tube fitting to the tubing. uring the rotary movement of the nut, the internal surface of the nut meets with the rear surface of the back ferrule to axially move the back ferrule forward against the rear angle of the front ferrule. Simultaneously, the front ferrule is driven forward into the angular section of the fitting body where the desired lift to seal action of the front ferrule occurs. he back ferrule locks on the outside diameter of the tube to complete the sealing action and secure the tube within the fitting. he resulting engineered gap between the front and back ferrule is designed to help compensate for exposure to system variables such as vibration, pressure pulsation and thermal expansion/contraction. QULIY SSP's Quality System has been certified to conform to the ISO 9001:2000 Quality Standard. chievement of this prestigious status further confirms SSP's continuing commitment to quality which is reflected throughout the company in its personnel, policies, equipment, products and service. In addition, all uolok tube fittings are manufactured to the technical design specifications and rigid quality control standards of SSP. RI Statistical Process ontrol techniques are employed within the manufacturing process to supply timely, meaningful feedback to the production team. ontinual process monitoring and equipment control provide the necessary manufacturing quality for uolok instrumentation grade tube fittings. 4
uolok Steel ube ittings PKIN uolok tube fittings are individually bagged to assure the highest levels of quality, safety and cleanliness. he protective bags eliminate contamination (tubing burrs, dirt, etc.) from entering the fitting prior to its use, and help to retain the integrity of the factory assembled body, nut, and ferrules. MPRUR ORS uolok tube fittings function reliably in applications ranging from cryogenic temperatures to high temperature bake out with the tube fitting material as the limiting factor. It is important to note that elevated temperatures will reduce the maximum working pressure capability of the tubing system. BILIY uolok tube fittings are designed, manufactured and quality controlled to be gageable for sufficient pull-up during initial installation. See page 9 for additional information. LIIM WRRNY uolok tube fittings are covered by a published Lifetime Warranty as printed on the inside back cover of this catalog. UB SLION areful selection and specification of tubing is essential to the performance of a tubing system. When choosing the appropriate tubing material, size and wall thickness, consideration must be given to the system s environment, pressures, temperatures and flows. s long as a uolok tube fitting is in its original protective bag, it is identified as factory new, completely assembled and ready for installation. dditionally, for efficient product identification and storage, the uolok tube fittings are packaged in boxes that are color-coded to the tube fittings' material of construction and have pictorial labels which include the part number, product description and box quantity. PRSSUR RINS enerally, uolok tube fittings are rated for pressures equal to the maximum allowable working pressures of the tubing recommended for use with the fittings. owever, it is important to note that many specially designed fittings, bored-through fittings and fittings having N, O-Seal and S/MS integral ends may have lower pressure ratings than that of the tubing. INRNBILIY uolok tube fittings are designed, manufactured and quality controlled to be totally interchangeable with the Swagelok brand of tube fittings. omponent by component examination plainly shows the two brands as completely component-intermixable". he precision manufacturing of both products to stringent tolerances under rigid quality control procedures ensures the safety, performance and reliability of service whenever uolok and Swagelok component parts are mixed and used in accordance with published installation and service recommendations. Swagelok is a registered rademark of the Swagelok o. 5
uolok Steel ube ittings INIIL INSLLION 1. uolok tube fittings come individually bagged and completely assembled for immediate use. here is no need for disassembly prior to use. Simply remove the tube fitting from its bag, insert the tube* until it bottoms in the uolok tube fitting body and then hand tighten the uolok nut. (See igure #1.) igure #3 1-1/4 turns for sizes 1/4-1 igure #3 Back-Up Wrench 2. While holding the fitting body stable with a back-up wrench, use a wrench to rotate the uolok nut to the fitting s original installation position (approximately 1/4 turn from the hand-tight, snug position) then continue to tighten the uolok nut slightly. (See igure #5.) igure #5 *ubing ends should be cut as straight as possible with all and I.. burrs removed. Use of a tubing cutter or guide blocks with a hacksaw is recommended. igure #1 [NO: or extreme system applications using high pressures or requiring an extra factor of safety, it may be desirable to use a "common makeup starting point" to alleviate the inherent variations in tubing diameters. Installation should begin from a "snug" position, which is achieved by wrench tightening the uolok nut until the inserted tubing will not move freely by hand (approximately 1/8 turn). rom this new "snug" starting point, continue with the recommended installation instructions.] 2. While holding the fitting body stable with a back-up wrench, scribe the nut for a reference point and wrench tighten the nut 1-1/4 turns for sizes 1/4" - 1" and 3/4 turn for sizes 1/16"- 3/16". (See igures #2 and #3.) igure #2 Only 3/4 of a turn for sizes 1/16-3/16 [NO: or all sizes, tighten plugs (P), machined ferrule end of port connector (P) and the uolok end of the emale N adapter (N) only 1/4 of a turn. ube fittings in sizes over 1 require the use of the SSP Instrumentation ydraulic Swaging ool for installation. ontact your uthorized SSP Instrumentation istributor for more information.] RSSMBLY INSRUIONS Back-Up Wrench 1. o reassemble a uolok tube fitting connection, simply insert the tubing with the previously swaged ferrules and uolok nut into the fitting body until the front ferrule seats within the fitting body, and then tighten the nut by hand. (See igure #4.) [NO: By following proper reassembly procedures, uolok tube fitting connections may be disconnected and reconnected repeatedly.] rom original installation position, tighten slightly OMPONN SSMBLY Should individual component assembly of a uolok tube fitting ever be required, careful attention must be given to the proper sequence and direction of the uolok components. (See igure #6.) Nut Back errule ront errule Body 6 Back-Up Wrench
uolok Steel ube ittings he uolok pre-setting tool is used to pre-set the ferrules on the tubing for subsequent installation in a fitting body. he pre-setting tool can be especially helpful when an installation must be made in a tight space or hard-to-work area. he presetting tool allows the major portion of the installation work to occur in a more favorable work setting with only the completion of the installation in the hard-to-work area. PR-SIN INSRUIONS 1. Secure the pre-setting tool in a vise. 2. Remove the protective nut, and assemble the uolok nut and ferrules loosely to the pre-setting tool. Insert the tubing through the nut and ferrules until it bottoms in the pre-setting tool, and then follow the standard uolok tube fitting installation instructions. (See igure #7 and #7B) igure #7 igure #7B 3. Loosen the nut and remove the tubing with the pre-set uolok ferrules and nut from the pre-setting tool. (See igure #8.) Return the protective nut to the presetting tool. igure #8 4. Installation of the tubing, with the pre-set uolok ferrules and nut in the appropriate fitting body, can now be made by following the standard reassembly instructions. (See igure #9 and #9B.) igure #9 igure #9B NO: o extend the life of a presetting tool, lubricate the tool with a lubricant compatible with the system s tubing material, environment and media. lso, at times an oversized or very soft tubing may tend to stick in the presetting tool after make up. o remove the tubing, gently rock the tube back and forth. Never turn the tube with pliers or another tool as such action may damage the sealing surfaces. BILIY Back-Up Wrench ach uolok tube fitting component is manufactured with utmost precision to provide the optimum performance interaction of the components during assembly. By maintaining such stringent manufacturing tolerances, the uolok tube fittings are considered gageable for sufficient pull-up during initial installation. he uolok "ap ages" are designed to identify for the installer or inspector, prior to pressurizing a system, that sufficient tightening of the tube fitting has occurred. ageability provides additional reliability for proper installation and ultimate tube fitting safety and performance. UOLOK P INSRUIONS 1. ollow proper installation instructions (as supplied with the fittings, or published in the uolok catalog). 2. fter completion of the installation instructions and prior to pressuring the system, choose the proper size ap age and try to insert it between the fitting's nut and body hex. (See igure #10) 3. If the ap age will not enter between the fitting's nut and body hex, no additional tightening is required. 4. If the ap age will enter between the fitting's nut and body hex, additional tightening is required. Note: Swagelok and Parker -LOK ap Inspection ages may also be utilized effectively with uolok tube fittings. No additional tightening required. dditional tightening required. Swagelok is a registered trademark of the Swagelok ompany. -Lok is a registered trademark of Parker annifin o. 7
Steel ube ittings MRILS OPRION QULIY SL straight configuration tube fittings are machined from cold-finished bar stock in accordance with SM -108. Shaped bodies are machined from close-grained steel forgings with material in accordance with SM -108 and SM -576. PLIN & OIN fittings are plated for corrosion resistance with zinc. ferrule is coated with phosphate for lubricity. Other chemically-inert platings may be utilized to assist installation. SIN tube fittings are designed and manufactured to provide a reliable, leak-proof connection in instrumentation and process tubing systems. tube fittings consist of three precisely machined components: 1) Body 2) errule 3) Nut he single ferrule design, with the spring-like action of the ferrule during make-up, compensates for the variations in tubing materials, hardness, and thickness of the tube wall to provide leak-tight connections in an extensive range of applications. dditionally, in fulfillment of the design criteria, all components are manufactured with extremely tight tolerances and superior surface finishes under rigorous quality control standards to assure the optimum performance of each component part. hrough the critical interaction of the precisely machined fitting components with the process tube, a leaktight seal is achieved. he simple geometric rotation of the nut provides the axial thrust necessary to coin the ferrule to the outside diameter of the tube. o eliminate any potential stress on an existing system, the tube fittings have been designed to not transmit installation torque from the tube fittings to the tubing. uring the rotary movement of the nut, the internal surface of the nut meets with the rear surface of the ferrule to axially move the ferrule forward into the angular section of the fitting body. he leading edge of the ferrule is directed into the tube to begin the required bowing action of the ferrule. Subsequently, the leading edge of the ferrule locks on the outside diameter of the tube to complete the sealing action and secure the tube within the fitting. he resulting spring-like action of the ferrule is designed to help compensate for exposure to system variables such as vibration, pressure pulsation and thermal expansion/contraction. SSP's Quality System has been certified to conform to the ISO 9001:2000 Quality Standard. chievement of this prestigious status further confirms SSP's continuing commitment to quality which is reflected throughout the company in its personnel, policies, equipment, products and service. In addition, all tube fittings are manufactured to the technical design specifications and rigid quality control standards of SSP. RI Statistical Process ontrol techniques are employed within the manufacturing process to supply timely, meaningful feedback to the production team. ontinual process monitoring and equipment control provide the necessary manufacturing quality for instrumentation grade tube fittings. 8
Steel ube ittings PKIN tube fittings are individually bagged to assure the highest levels of quality, safety and cleanliness. he protective bags eliminate contamination (tubing burrs, dirt, etc.) from entering the fitting prior to its use, and help to retain the integrity of the factory assembled body, nut, and ferrule. s long as a tube fitting is in its original protective bag, it is identified as factory new, completely assembled and ready for installation. MPRUR ORS tube fittings function reliably in applications ranging from cryogenic temperatures to high temperature bake out with the tube fitting material as the limiting factor. It is important to note that elevated temperatures will reduce the maximum working pressure capability of the tubing system. BILIY tube fittings are designed, manufactured and quality controlled to be gageable for sufficient pull-up during initial installation. INRNBILIY LIIM WRRNY tube fittings are covered by a published Lifetime Warranty as printed on the inside back cover of this catalog. UB SLION areful selection and specification of tubing is essential to the performance of a tubing system. When choosing the appropriate tubing material, size and wall thickness, consideration must be given to the system s environment, pressures, temperatures and flows. he individually bagged tube fittings are packaged in convenient, small-lot quantities for easy procurement and handling. dditionally, for efficient product identification and storage, the boxes are color-coded to the tube fittings' material of construction and have pictorial labels which include the part number, product description and box quantity. PRSSUR RINS enerally, tube fittings are rated for pressures equal to the maximum allowable working pressures of the tubing recommended for use with the fittings. owever, it is important to note that many specially designed fittings, bored-through fittings and fittings having N, O-Seal and S/MS integral ends may have lower pressure ratings than that of the tubing. tube fittings are designed, manufactured and quality controlled to be totally interchangeable with the Parker PI M brand of tube fittings. omponent by component examination plainly shows the two brands as completely componentintermixable". he precision manufacturing of both products to stringent tolerances under rigid quality control procedures ensures the safety, performance and reliability of service whenever and Parker PI component parts are mixed and used in accordance with published installation and service recommendations. dditionally, tube fittings are considered able to be "functionally interchangeable" with the Swagelok brand of tube fitting. "unctionally interchangeable" allows for the use of a nut and/or ferrule with a Swagelok body, or a Swagelok nut and/or ferrule system with a body. he exceptional quality characteristics of both product lines assure complete product performance whenever the two brands are "functionally interchanged". Swagelok is a registered rademark of the Swagelok o. PI is a registered trademark of Parker annifin o. 9
Steel ube ittings INIIL INSLLION 1. tube fittings come individually bagged and completely assembled for immediate use. here is no need for disassembly prior to use. Simply remove the tube fitting from its bag, insert the tube* until it bottoms in the tube fitting body and then hand tighten the nut. See igure #1. igure #1 igure #3 1-1/4 turns for sizes 1/4-1 igure #3 Back-Up Wrench 2. While holding the fitting body stable with a back-up wrench, use a wrench to rotate the nut to the fitting s original installation position (approximately 1/4 turn from the hand-tight, snug position) then continue to tighten the nut slightly. See igure #5. igure #4 *ubing ends should be cut as straight as possible with all and I.. burrs removed. Use of a tubing cutter or guide blocks with a hacksaw is recommended. [NO: or extreme system applications using high pressures or requiring an extra factor of safety, it may be desirable to use a "common makeup starting point" to alleviate the inherent variations in tubing diameters. Installation should begin from a "snug" position, which is achieved by wrench tightening the nut until the inserted tubing will not move freely by hand (approximately 1/8 turn). rom this new "snug" starting point, continue with the recommended installation instructions.] 2. While holding the fitting body stable with a back-up wrench, scribe the nut for a reference point and wrench tighten the nut 1-1/4 turns for sizes 1/4" - 1" and 3/4 turn for sizes 1/16"- 3/16". See igures #2 and #3. igure #2 Only 3/4 of a turn for sizes 1/16-3/16 [NO: or all sizes, tighten plugs (P), machined ferrule end of port connector (P) and the end of the emale N dapter (N) only 1/4 of a turn.] RSSMBLY INSRUIONS 1. o reassemble a tube fitting connection, simply insert the tubing with the previously swaged ferrule and nut into the fitting body until the ferrule seats within the fitting body, and then tighten the nut by hand. See igure #4. igure #4 Back-Up Wrench [NO: By following proper reassembly procedures, tube fitting connections may be disconnected and reconnected repeatedly.] rom original installation position, tighten slightly OMPONN SSMBLY Should individual component assembly of a tube fitting ever be required, careful attention must be given to the proper sequence and direction of the components. See igure #6. Nut errule Body Back-Up Wrench 10
Steel ube ittings he pre-setting tool is used to pre-set the ferrule on the tubing for subsequent installation in a fitting body. he pre-setting tool can be especially helpful when an installation must be made in a tight space or hard-to-work area. he presetting tool allows the major portion of the installation work to occur in a more favorable work setting with only the completion of the installation in the hard-to-work area. PR-SIN INSRUIONS 1. Secure the pre-setting tool in a vise. 2. Remove the protective nut, and assemble the nut and ferrule loosely to the pre-setting tool. Insert the tubing through the nut and ferrule until it bottoms in the pre-setting tool, and then follow the standard tube fitting installation instructions from page 8. (See igures #7 and #7B) igure #7 igure #7B 3. Loosen the nut and remove the tubing with the pre-set ferrule and nut from the pre-setting tool. (See igure #8.) Return the protective nut to the presetting tool. igure #8 4. Installation of the tubing, with the pre-set ferrule and nut in the appropriate fitting body, can now be made by following the standard reassembly instructions from page 8. (See igures #9 and #9B.) igure #9 igure #9B Back-Up Wrench NO: o extend the life of a pre-setting tool, lubricate the tool with a lubricant compatible with the system s tubing material, environ-ment and media. lso, at times an oversized or very soft tubing may tend to stick in the presetting tool after make up. o remove the tubing, gently rock the tube back and forth. Never turn the tube with pliers or another tool as such action may damage the sealing surfaces. BILIY ach tube fitting component is manufactured with utmost precision to provide the optimum performance interaction of the components during assembly. By maintaining such stringent manufacturing tolerances, the tube fittings are considered gageable for sufficient pull-up during initial installation. he "ap ages" are designed to identify for the installer or inspector, prior to pressurizing a system, that sufficient tightening of the tube fitting has occurred. ageability provides additional reliability for proper installation and ultimate tube fitting safety and performance. UNILOK P INSRUIONS 1. ollow proper installation instructions (as supplied with the fittings, or published in the catalog). 2. fter completion of the installation instructions and prior to pressuring the system, choose the proper size ap age and try to insert it between the fitting's nut and body hex. (See igure #10) 3. If the ap age will not enter between the fitting's nut and body hex, no additional tightening is required. 4. If the ap age will enter between the fitting's nut and body hex, additional tightening is required. Note: Parker PI Inspection auges may also be utilized effectively with tube fittings. No additional tightening required. dditional tightening required. PI is a registered trademark of Parker annifin o. 11
uolok Steel ube ittings ube to Male Pipe Male onnector Male lbow Male Branch ee Male Run ee Male dapter M 14 M 14 MB 15 MR 15 M 16 ube to emale Pipe emale onnector ube to ube Union Union Union lbow ap & Plug ap emale lbow 17 U Union ee 19 U 19 Bulkhead Union P Plug 22 emale dapter 17 U 20 BU 20 Reducing Union Reducer/dapter P 22 18 RU 21 R 21 omponents Nut Back errule ront errule 12 N 22 B 22 22
Steel ube ittings ube to Male Pipe Male onnector Male lbow Male Branch ee Male Run ee Male dapter M 23 M 23 MB 24 MR 24 M 25 ube to emale Pipe ube to ube Union ap & Plug emale onnector Union Union lbow ap emale lbow 26 U Union ee 28 U Bulkhead Union 28 P Plug 24 emale dapter 26 U Reducing Union 29 BU Reducer/dapter 29 P 31 27 RU 30 R 30 omponents Nut errule N 31 31 13
uolok Steel ube ittings BOY X NU X B-BOY P-PIP R Male onnector (M) uolok ube P-NP Male Pipe Size B Min. 4M2 1/4 1/8 1.29 1.00 0.70 0.60 0.17 0.38 9/16 1/2 4M4 1/4 1/4 1.49 1.20 0.70 0.60 0.19 0.56 9/16 1/2 4M6 1/4 3/8 1.51 1.22 0.70 0.60 0.19 0.56 9/16 11/16 4M8 1/4 1/2 1.76 1.47 0.70 0.60 0.19 0.75 9/16 7/8 6M2 3/8 1/8 1.39 1.10 0.76 0.66 0.19 0.38 11/16 5/8 6M4 3/8 1/4 1.57 1.28 0.76 0.66 0.28 0.56 11/16 5/8 6M6 3/8 3/8 1.57 1.28 0.76 0.66 0.28 0.56 11/16 11/16 6M8 3/8 1/2 1.82 1.53 0.76 0.66 0.28 0.75 11/16 7/8 8M4 1/2 1/4 1.71 1.31 0.86 0.90 0.28 0.56 7/8 13/16 8M6 1/2 3/8 1.71 1.31 0.86 0.90 0.38 0.56 7/8 13/16 8M8 1/2 1/2 1.93 1.53 0.86 0.90 0.41 0.75 7/8 7/8 12M12 3/4 3/4 1.99 1.59 0.86 0.96 0.62 0.75 1-1/8 1-1/16 16M16 1 1 2.45 1.97 1.04 1.23 0.88 0.94 1-1/2 1-3/8 NU X -WRN P By P-PIP R Male lbow (M) uolok ube P-NP Male Pipe Size By 4M2 1/4 1/8 1.06 0.77 0.74 0.70 0.60 0.17 0.38 9/16 1/2 4M4 1/4 1/4 1.06 0.77 0.92 0.70 0.60 0.17 0.38 9/16 1/2 6M4 3/8 1/4 1.2 0.91 1.00 0.76 0.66 0.28 0.56 11/16 5/8 6M6 3/8 3/8 1.23 0.94 1.03 0.76 0.66 0.28 0.56 11/16 11/16 6M8 3/8 1/2 1.31 1.02 1.30 0.76 0.66 0.28 0.75 11/16 7/8 8M4 1/2 1/4 1.42 1.02 1.11 0.86 0.90 0.28 0.56 7/8 13/16 8M6 1/2 3/8 1.42 1.02 1.11 0.86 0.90 0.38 0.56 7/8 13/16 8M8 1/2 1/2 1.42 1.02 1.30 0.86 0.90 0.41 0.75 7/8 7/8 12M12 3/4 3/4 1.57 1.17 1.45 0.86 0.96 0.62 0.75 1-1/8 1-1/16 16M16 1 1 1.93 1.45 1.83 1.04 1.23 0.88 0.94 1-1/2 1-3/8 Min. 14 inger -tight assembly dimensions (shown in inches) are for reference only and subject to change.
uolok Steel ube ittings B-BOY NU X By -WRN P P-PIP R Male Branch ee (MB) uolok ube P-NP Male Pipe Size x B By 4MB2 1/4 1/8 2.12 1.06 1.54 0.77 0.74 0.70 0.60 0.17 0.38 9/16 1/2 4MB4 1/4 1/4 2.12 1.06 1.54 0.77 0.92 0.70 0.60 0.17 0.56 9/16 9/16 6MB4 3/8 1/4 2.40 1.20 1.82 0.91 1.00 0.76 0.66 0.28 0.56 11/16 5/8 8MB8 1/2 1/2 2.84 1.42 2.04 1.02 1.30 0.86 0.90 0.41 0.75 7/8 7/8 x Min. x NU X B-BOY P-PIP R x -WRN P Male Run ee (MR) uolok ube P-NP Male Pipe Size x B By 4MR2 1/4 1/8 1.80 1.06 1.51 0.77 0.74 0.70 0.60 0.17 0.38 9/16 1/2 4MR4 1/4 1/4 1.98 1.06 1.69 0.77 0.92 0.70 0.60 0.19 0.56 9/16 9/16 6MR4 3/8 1/4 2.20 1.20 1.91 0.91 1.00 0.76 0.66 0.28 0.56 11/16 5/8 8MR8 1/2 1/2 2.72 1.42 2.32 1.02 1.30 0.86 0.90 0.41 0.75 7/8 7/8 x Min. By inger -tight assembly dimensions (shown in inches) are for reference only and subject to change. 15
uolok Steel ube ittings B P-PIP R Male dapter (M) uolok ube P-NP Male Pipe Size B Min. 4M2 1/4 1/8 1.25 0.16 0.38 7/16 4M4 1/4 1/4 1.46 0.18 0.56 9/16 4M6 1/4 3/8 1.49 0.18 0.56 11/16 4M8 1/4 1/2 1.71 0.18 0.75 7/8 6M2 3/8 1/8 1.32 0.19 0.38 7/16 6M4 3/8 1/4 1.53 0.28 0.56 9/16 6M6 3/8 3/8 1.56 0.28 0.56 11/16 6M8 3/8 1/2 1.78 0.28 0.75 7/8 8M4 1/2 1/4 1.75 0.28 0.56 9/16 8M6 1/2 3/8 1.78 0.38 0.56 11/16 8M8 1/2 1/2 2.00 0.38 0.75 7/8 8M12 1/2 3/4 2.00 0.38 0.76 1-1/16 12M8 3/4 1/2 2.06 0.47 0.75 7/8 12M12 3/4 3/4 2.06 0.59 0.75 11/16 12M16 3/4 1 2.33 0.59 0.95 1-3/8 16M8 1 1/2 2.41 0.55 0.95 1-1/16 16M12 1 3/4 2.31 0.63 0.75 11/16 16M16 1 1 2.60 0.80 0.94 13/8 Union ee Male dapter Male Run ee Male dapter fittings allow any uolok tube fitting connection to be converted to connect to female NP 16 inger -tight assembly dimensions (shown in inches) are for reference only and subject to change.
uolok Steel ube ittings NU X B-BOY BOY X P-PIP R emale onnector () uolok ube P-NP emale Pipe Size B 42 1/4 1/8 1.23 0.94 0.70 0.60 0.19 9/16 9/16 44 1/4 1/4 1.41 1.12 0.70 0.60 0.19 9/16 3/4 64 3/8 1/4 1.48 1.19 0.76 0.66 0.28 11/16 3/4 66 3/8 3/8 1.54 1.25 0.76 0.66 0.28 11/16 7/8 86 1/2 3/8 1.65 1.25 0.86 0.90 0.41 7/8 7/8 88 1/2 1/2 1.84 1.44 0.86 0.90 0.41 7/8 1-1/16 NU X -BOY -WRN P By emale lbow () P-PIP R uolok ube P-NP emale Pipe Size By 42 1/4 1/8 1.06 0.77 0.75 0.70 0.60 0.19 9/16 1/2 44 1/4 1/4 1.17 0.88 0.88 0.70 0.60 0.19 9/16 11/16 64 3/8 1/4 1.23 0.94 0.88 0.76 0.66 0.28 11/16 11/16 88 1/2 1/2 1.53 1.13 1.12 0.86 0.90 0.41 7/8 1 inger -tight assembly dimensions (shown in inches) are for reference only and subject to change. 17
uolok Steel ube ittings P-PIP R X B emale dapter () uolok ube P-NP emale Pipe Size B Min. 42 1/4 1/8 1.30 0.19 0.41 9/16 44 1/4 1/4 1.46 0.19 0.59 3/4 46 1/4 3/8 1.56 0.19 0.59 7/8 48 1/4 1/2 1.79 0.19 0.78 1-1/16 62 3/8 1/8 1.35 0.28 0.41 9/16 64 3/8 1/4 1.50 0.28 0.59 3/4 66 3/8 3/8 1.59 0.28 0.59 7/8 68 3/8 1/2 1.84 0.28 0.78 1-1/16 84 1/2 1/4 1.71 0.38 0.59 3/4 86 1/2 3/8 1.79 0.39 0.59 7/8 88 1/2 1/2 2.04 0.39 0.78 1-1/16 812 1/2 3/4 2.10 0.39 0.81 1-5/16 128 3/4 1/2 2.09 0.50 0.78 1-1/16 1212 3/4 3/4 2.16 0.50 0.81 1-5/16 1216 3/4 1 2.30 0.50 1.00 1-5/8 168 1 1/2 2.38 0.78 0.95 1-5/16 1612 1 3/4 2.39 0.80 0.81 1-1/4 1616 1 1 2.53 0.80 1.00 1-5/8 Union ee emale dapter emale Run ee emale dapter fittings allow any uolok tube fitting connection to be converted to connect to male NP 18 inger -tight assembly dimensions (shown in inches) are for reference only and subject to change.
uolok Steel ube ittings -BOY X B-BOY NU X Union (U) uolok ube B 4U 1/4 1.61 1.03 0.70 0.60 0.19 9/16 1/2 6U 3/8 1.77 1.19 0.76 0.66 0.28 11/16 5/8 8U 1/2 2.02 1.22 0.86 0.90 0.41 7/8 13/16 12U 3/4 2.11 1.31 0.86 0.96 0.62 1-1/8 1-1/16 16U 1 2.55 1.59 1.04 1.23 0.88 1-1/2 1 3/8 NU X -WRN P Union lbow (U) uolok ube 4U 1/4 1.06 0.77 0.70 0.60 0.19 9/16 1/2 6U 3/8 1.20 0.91 0.76 0.66 0.28 11/16 5/8 8U 1/2 1.42 1.02 0.86 0.90 0.41 7/8 13/16 12U 3/4 1.57 1.17 0.86 0.96 0.62 1-1/8 1-1/16 16U 1 1.93 1.45 1.04 1.23 0.88 1-1/2 1-3/8 inger -tight assembly dimensions (shown in inches) are for reference only and subject to change. 19
uolok Steel ube ittings B-BOY NU X x -WRN P Union ee (U) x x uolok ube x B 4U 1/4 2.12 1.06 1.54 0.77 0.70 0.60 0.19 9/16 1/2 6U 3/8 2.40 1.20 1.82 0.91 0.76 0.66 0.28 11/16 5/8 8U 1/2 2.84 1.42 2.04 1.02 0.86 0.90 0.41 7/8 13/16 12U 3/4 3.14 1.57 2.34 1.17 0.86 0.96 0.62 1-1/8 1-1/16 16U 1 3.86 1.93 2.90 1.45 1.04 1.23 0.88 1-1/2 1-3/8 NU X B-BOY -BOY X Bulkhead Union (BU) uolok ube x B -JM NU X x Maximum Panel hickness Panel ole rill Size 4BU 1/4 2.27 1.32 1.69 1.03 0.70 0.60 0.19 9/16 5/8 0.40 29/64 6BU 3/8 2.45 1.45 1.87 1.16 0.76 0.66 0.28 11/16 3/4 0.44 37/64 8BU 1/2 2.80 1.65 2.00 1.25 0.86 0.90 0.41 7/8 15/16 0.50 49/64 20 inger -tight assembly dimensions (shown in inches) are for reference only and subject to change.
uolok Steel ube ittings NU X B-BOY -BOY X NU X x x Reducing Union (RU) x x uolok ube x ube B x x x 6RU4 3/8 1/4 1.70 1.12 0.76 0.70 0.66 0.60 0.19 11/16 9/16 5/8 8RU4 1/2 1/4 1.85 1.16 0.86 0.70 0.90 0.60 0.19 7/8 9/16 13/16 8RU6 1/2 3/8 1.91 1.22 0.86 0.76 0.90 0.66 0.28 7/8 11/16 13/16 NU X UB I. B-BOY x Reducer/dapter (R) -BOY X uolok ube x B 4R6 1/4 3/8 1.60 1.31 0.70 0.60 0.24 9/16 1/2 4R8 1/4 1/2 1.82 1.53 0.70 0.60 0.33 9/16 9/16 6R4 3/8 1/4 1.63 1.34 0.76 0.66 0.15 11/16 5/8 6R8 3/8 1/2 1.91 1.62 0.76 0.66 0.33 11/16 5/8 8R12 1/2 3/4 2.12 1.72 0.86 0.90 0.51 7/8 13/16 inger -tight assembly dimensions (shown in inches) are for reference only and subject to change. 21
uolok Steel ube ittings ap () NU X B-BOY BOY X uolok ube B 4P 1/4 0.92 0.63 0.70 0.60 9/16 1/2 6P 3/8 1.01 0.72 0.76 0.66 11/16 5/8 8P 1/2 1.15 0.75 0.86 0.90 7/8 13/16 aps are used for capping the end of a tubing run. ap Installation Instructions he standard uolok fitting installation instructions apply for proper installation of caps (see page 6). Plug (P) NU X uolok Part# ube 4P 1/4 9/16 6P 3/8 11/16 8P 1/2 7/8 Plugs are used to plug an unused port of a uolok tube fitting. Plug Installation Instructions 1. Remove nut and ferrules from the port of the tube fitting body to be plugged and replace with the uolok plug. 2. and- tighten the uolok plug and then while holding the tube fitting body steady with a back-up wrench, use a wrench to tighten the uolok plug only 1/4 of a turn. Nut (N) NU X uolok ube L 4N 1/4 9/16 0.50 6N 3/8 11/16 0.56 8N 1/2 7/8 0.69 12N 3/4 1-1/8 0.69 16N 1 1-1/2 0.81 L 22 ront errule () uolok ube IS4 1/4 IS6 3/8 IS8 1/2 IS12 3/4 IS16 1 Back errule (B) uolok ube ISS4B 1/4 ISS6B 3/8 ISS8B 1/2 ISS12B 3/4 ISS16B 1 inger -tight assembly dimensions (shown in inches) are for reference only and subject to change.
Steel ube ittings NU X B-BOY BOY X Male onnector (M) P-PIP R ube P-NP Male Pipe Size B U4M2 1/4 1/8 1.29 1.00 0.70 0.60 0.19 0.38 9/16 1/2 U4M4 1/4 1/4 1.49 1.20 0.70 0.60 0.19 0.56 9/16 9/16 U4M6 1/4 3/8 1.51 1.22 0.70 0.60 0.19 0.56 9/16 11/16 U4M8 1/4 1/2 1.76 1.47 0.70 0.60 0.19 0.75 9/16 7/8 U6M2 3/8 1/8 1.39 1.10 0.76 0.66 0.19 0.38 11/16 5/8 U6M4 3/8 1/4 1.57 1.28 0.76 0.66 0.28 0.56 11/16 5/8 U6M6 3/8 3/8 1.57 1.28 0.76 0.66 0.28 0.56 11/16 1-1/16 U6M8 3/8 1/2 1.82 1.53 0.76 0.66 0.28 0.75 11/16 7/8 U8M4 1/2 1/4 1.71 1.31 0.86 0.90 0.28 0.56 7/8 13/16 U8M6 1/2 3/8 1.71 1.31 0.86 0.90 0.38 0.56 7/8 13/16 U8M8 1/2 1/2 1.93 1.53 0.86 0.90 0.41 0.75 7/8 7/8 U12M12 3/4 3/4 1.99 1.59 0.86 0.96 0.62 0.75 1-1/8 1-1/16 U16M16 1 1 2.45 1.97 1.04 1.23 0.88 0.94 1-1/2 1-3/8 Min. NU X -WRN P By Male lbow (M) ube P-NP MalePipe Size By U P-PIP R Min. U4M2 1/4 1/8 1.06 0.77 0.74 0.70 0.60 0.17 0.38 9/16 1/2 U4M4 1/4 1/4 1.06 0.77 0.92 0.70 0.60 0.19 0.56 9/16 1/2 U6M4 3/8 1/4 1.20 0.91 1.00 0.76 0.66 0.28 0.56 11/16 5/8 U6M6 3/8 3/8 1.23 0.94 1.03 0.76 0.66 0.28 0.56 11/16 11/16 U6M8 3/8 1/2 1.31 1.02 1.30 0.76 0.66 0.28 0.75 11/16 7/8 U8M4 1/2 1/4 1.42 1.02 1.11 0.86 0.90 0.28 0.56 7/8 13/16 U8M6 1/2 3/8 1.42 1.02 1.11 0.86 0.90 0.38 0.56 7/8 13/16 U8M8 1/2 1/2 1.42 1.02 1.30 0.86 0.90 0.41 0.75 7/8 7/8 U12M12 3/4 3/4 1.57 1.17 1.45 0.86 0.96 0.62 0.75 1-1/8 1-1/16 U16M16 1 1 1.93 1.45 1.83 1.04 1.23 0.88 0.75 1-1/2 1-3/8 inger -tight assembly dimensions (shown in inches) are for reference only and subject to change. 23
Steel ube ittings B-BOY NU X By -WRN P Male Branch ee (MB) ube P-NP Male Pipe Size x B By U U4MB2 1/4 1/8 2.12 1.06 1.54 0.77 0.74 0.70 0.60 0.17 0.38 9/16 1/2 U4MB4 1/4 1/4 2.12 1.06 1.54 0.77 0.92 0.70 0.60 0.17 0.56 9/16 9/16 U6MB4 3/8 1/4 2.40 1.20 1.82 0.91 1.00 0.76 0.66 0.28 0.56 11/16 5/8 U8MB8 1/2 1/2 2.84 1.42 2.04 1.02 1.30 0.86 0.90 0.41 0.75 7/8 7/8 x Min. P-PIP R x NU X B-BOY P-PIP R x -WRN P Male Run ee (MR) ube P-NP Male Pipe Size x B By U4MR2 1/4 1/8 1.80 1.06 1.51 0.77 0.74 0.70 0.60 0.17 0.38 9/16 1/2 U4MR4 1/4 1/4 1.98 1.06 1.69 0.77 0.92 0.70 0.60 0.19 0.56 9/16 9/16 U6MR4 3/8 1/4 2.20 1.20 1.91 0.91 1.00 0.76 0.66 0.28 0.56 11/16 5/8 U8MR8 1/2 1/2 2.72 1.42 2.32 1.02 1.30 0.86 0.90 0.41 0.75 7/8 7/8 x Min. By 24 inger -tight assembly dimensions (shown in inches) are for reference only and subject to change.
Steel ube ittings P-PIP R B Male dapter (M) ube P-NP Male Pipe Size B Min. U4M2 1/4 1/8 1.21 0.12 0.38 7/16 U4M4 1/4 1/4 1.40 0.13 0.56 9/16 U4M6 1/4 3/8 1.43 0.14 0.56 11/16 U4M8 1/4 1/2 1.65 0.14 0.75 7/8 U6M2 3/8 1/8 1.31 0.19 0.38 7/16 U6M4 3/8 1/4 1.50 0.24 0.56 9/16 U6M6 3/8 3/8 1.50 0.24 0.56 11/16 U6M8 3/8 1/2 1.71 0.24 0.75 7/8 U8M4 1/2 1/4 1.71 0.28 0.56 9/16 U8M6 1/2 3/8 1.75 0.33 0.56 11/16 U8M8 1/2 1/2 1.93 0.33 0.75 7/8 U8M12 1/2 3/4 2.00 0.38 0.75 1-1/16 U12M8 3/4 1/2 2.00 0.47 0.75 7/8 U12M12 3/4 3/4 2.03 0.51 0.75 1-1/16 U12M16 3/4 1 2.33 0.59 0.95 1-3/8 U16M8 1 1/2 2.41 0.55 0.76 1-1/16 U16M12 1 3/4 2.28 0.62 0.75 1-1/16 U16M16 1 1 2.56 0.75 0.94 1-3/8 Union ee Male dapter Male Run ee Male dapter fittings allow any tube fitting connection to be converted to connect to female NP inger -tight assembly dimensions (shown in inches) are for reference only and subject to change. 25
Steel ube ittings NU X B-BOY BOY X emale onnector () P-PIP R ube P-NP emale Pipe Size B U42 1/4 1/8 1.23 0.94 0.70 0.60 0.19 9/16 9/16 U44 1/4 1/4 1.41 1.12 0.70 0.60 0.19 9/16 3/4 U64 3/8 1/4 1.48 1.19 0.76 0.66 0.28 11/16 3/4 U66 3/8 3/8 1.54 1.25 0.76 0.66 0.28 11/16 7/8 U86 1/2 3/8 1.65 1.25 0.86 0.90 0.41 7/8 7/8 U88 1/2 1/2 1.84 1.44 0.86 0.90 0.41 7/8 1-1/16 NU X -BOY -WRN P By emale lbow () P-PIP R ube P-NP emale Pipe Size By U42 1/4 1/8 1.06 0.77 0.75 0.70 0.60 0.19 9/16 1/2 U44 1/4 1/4 1.17 0.88 0.88 0.70 0.60 0.19 9/16 11/16 U64 3/8 1/4 1.23 0.94 0.88 0.76 0.66 0.28 11/16 11/16 U88 1/2 1/2 1.53 1.13 1.12 0.86 0.90 0.41 7/8 1 26 inger -tight assembly dimensions (shown in inches) are for reference only and subject to change.
Steel ube ittings P-PIP R X B emale dapter () ube P-NP emale Pipe Size B U42 1/4 1/8 1.32 0.18 9/16 U44 1/4 1/4 1.43 0.18 3/4 U46 1/4 3/8 1.56 0.18 7/8 U48 1/4 1/2 1.46 0.18 1-1/16 U62 3/8 1/8 1.39 0.28 9/16 U64 3/8 1/4 1.50 0.28 3/4 U66 3/8 3/8 1.62 0.28 7/8 U68 3/8 1/2 1.84 0.28 1-1/16 U84 1/2 1/4 1.71 0.39 3/4 U86 1/2 3/8 1.84 0.39 7/8 U88 1/2 1/2 2.06 0.39 1-1/16 U812 1/2 3/4 2.10 0.39 1-5/16 U128 3/4 1/2 2.12 0.59 1-1/16 U1212 3/4 3/4 2.18 0.59 1-5/16 U1216 3/4 1 2.46 0.59 1-5/8 U168 1 1/2 2.38 0.95 1-5/16 U1612 1 3/4 2.43 0.95 1-1/4 U1616 1 1 2.71 0.95 1-5/8 Union ee emale dapter emale Run ee emale dapter fittings allow any tube fitting connection to be converted to connect to male NP inger -tight assembly dimensions (shown in inches) are for reference only and subject to change. 27
Steel ube ittings -BOY X B-BOY NU X Union (U) ube B U4U 1/4 1.61 1.03 0.70 0.60 0.19 9/16 1/2 U6U 3/8 1.77 1.19 0.76 0.66 0.28 11/16 5/8 U8U 1/2 2.02 1.22 0.86 0.90 0.41 7/8 13/16 U12U 3/4 2.11 1.31 0.86 0.96 0.62 1-1/8 1-1/16 U16U 1 2.55 1.59 1.04 1.23 0.88 1-1/2 1-3/8 NU X -WRN P Union lbow (U) ube U4U 1/4 1.06 0.77 0.70 0.60 0.19 9/16 1/2 U6U 3/8 1.20 0.91 0.76 0.66 0.28 11/16 5/8 U8U 1/2 1.42 1.02 0.86 0.90 0.41 7/8 13/16 U12U 3/4 1.57 1.17 0.86 0.96 0.62 1-1/8 1-1/16 U16U 1 1.93 1.45 1.04 1.23 0.88 1-1/2 1-3/8 28 inger -tight assembly dimensions (shown in inches) are for reference only and subject to change.
Steel ube ittings B-BOY NU X x -WRN P x x Union ee (U) ube x B U4U 1/4 2.12 1.06 1.54 0.77 0.70 0.60 0.19 9/16 1/2 U6U 3/8 2.40 1.20 1.82 0.91 0.76 0.66 0.28 11/16 5/8 U8U 1/2 2.84 1.42 2.04 1.02 0.86 0.90 0.41 7/8 13/16 U12U 3/4 3.14 1.57 2.34 1.17 0.86 0.96 0.62 1-1/8 1/16 U16U 1 3.86 1.93 2.90 1.45 1.04 1.23 0.88 1-1/2 1-3/8 NU X B-BOY -BOY X -JM NU X x Bulkhead Union (BU) ube x B Maximum Panel hickness Panel ole rill Size U4BU 1/4 2.27 1.32 1.69 1.03 0.70 0.60 0.19 9/16 5/8 0.40 29/64 U6BU 3/8 2.45 1.45 1.87 1.16 0.76 0.66 0.28 11/16 3/4 0.44 37/64 U8BU 1/2 2.80 1.65 2.00 1.25 0.86 0.90 0.41 7/8 15/16 0.50 49/64 inger -tight assembly dimensions (shown in inches) are for reference only and subject to change. 29
Steel ube ittings NU X B-BOY -BOY X NU X x x x x Reducing Union (RU) ube x ube B x x x U6RU4 3/8 1/4 1.70 1.12 0.76 0.70 0.66 0.60 0.19 11/16 9/16 5/8 U8RU4 1/2 1/4 1.85 1.16 0.86 0.70 0.90 0.60 0.19 7/8 9/16 13/16 U8RU6 1/2 3/8 1.91 1.22 0.86 0.76 0.90 0.66 0.28 7/8 11/16 13/16 NU X UB I. B-BOY x Reducer/dapter (R) -BOY X ube x B U4R6 1/4 3/8 1.60 1.31 0.70 0.60 0.24 9/16 1/2 U4R8 1/4 1/2 1.82 1.53 0.70 0.60 0.33 9/16 9/16 U6R4 3/8 1/4 1.63 1.34 0.76 0.66 0.15 11/16 5/8 U6R8 3/8 1/2 1.91 1.62 0.76 0.66 0.33 11/16 5/8 U8R12 1/2 3/4 2.12 1.72 0.86 0.90 0.51 7/8 13/16 30 inger -tight assembly dimensions (shown in inches) are for reference only and subject to change.
Steel ube ittings ap (P) ube B U4P 1/4 0.97 0.11 0.74 0.37 U6P 3/8 1.03 0.24 0.80 0.50 U8P 1/2 1.41 0.33 1.02 0.62 aps are used for capping the end of a tubing run. ap Installation Instructions he standard fitting installation instructions apply for proper installation of caps (see page 10). V NU X B-BOY BOY X Plug (P) ube NU X U4P 1/4 9/16 U6P 3/8 11/16 U8P 1/2 7/8 Plugs are used to plug an unused port of a tube fitting. Plug Installation Instructions 1. Remove nut and ferrules from the port of the tube fitting body to be plugged and replace with the plug. 2. and- tighten the plug and then while holding the tube fitting body steady with a back-up wrench, use a wrench to tighten the plug only 1/4 of a turn. Nut (N) NU X ube L U4N 1/4 9/16 0.50 U6N 3/8 11/16 0.56 U8N 1/2 7/8 0.69 U12N 3/4 1-1/8 0.69 U16N 1 1-1/2 0.81 L errule () ube ISU4 1/4 ISU6 3/8 ISU8 1/2 ISU12 3/4 ISU16 1 inger -tight assembly dimensions (shown in inches) are for reference only and subject to change. Sizes 4 & 6 Size 8 31
Pressures, ittings and ubing ube Size (in.) RBON SL UBIN Maximum llowable Working Pressure (PSI) Wall hickness of ube (Inches).028.035.049.065.083.095.109.120 1/8 8100 10500 3/16 5150 6700 9900 1/4 3750 4850 7100 9900 5/16 3800 5500 7600 3/8 3100 4500 6200 1/2 2300 3300 4500 5950 5/8 1800 2600 3500 4600 5350 3/4 2150 2900 3750 4375 5100 7/8 1800 2450 3200 3700 4300 1 1550 2100 2750 3200 3700 4125 Note: or light gas service, use tubing with wall thickness outside of shaded area. alculation Basis: nnealed, seamless carbon steel tubing SM -179 or equivalent. System temperatures between -20 and +100 with allowable stress of 15,700 psi. Safety factor of 4. Reference: NSI B 31.3 ode. (or more specific working pressure information regarding a particular tubing, consult the tubing manufacturer.) Suggested ube Ordering Information: Specify the outside diameter and wall thickness of annealed, seamless carbon steel tubing of SM -179 or equivalent specification. lso specify high quality tubing to be free of scratches, and suited for bending with material hardness not to exceed Rb 72. SSP NP PIP N PRSSUR RINS, NSI/SM B31.3 NP/ISO Male emale Size Pipe Size psig bar psig bar 1/16" 1 11000 760 6700 460 1/8" 2 10000 690 6500 440 1/4" 4 8000 550 6600 450 3/8" 6 7800 540 5300 360 1/2" 8 7700 530 4900 330 3/4" 12 7300 500 4600 320 1" 16 5300 370 4400 300 Reference: bar=.0695 X psig o obtain NSI/SM B 31.1 values, multiply above values by 0.85 R SL R Radius of tubing bend as required or minimum alloed for specified wall thickness and tube size as recommended by tubing manufacturer. INSLLIN UB IINS NR UB BNS When installing fittings near tube bends, it is important to bend tubing prior to installing tube fittings and there must be a sufficient straight length (SL) of tubing to allow the tube to be bottomed in the fitting. See table below. =ube (in.) 1/16 1/8 3/16 1/4 5/16 3/8 1/2 5/8 3/4 7/8 1 1-1/4 1-1/2 2 SL straight tube *SL= length required from end of tube Straight 1/2 3/4 3/4 13/16 7/8 15/16 1-3/16 1-1/4 1-1/4 1-5/16 1-9/16 2 2-13/32 3-1/4 to beginning of bend. Length of ube ube outside diameter (in.) R Radius of tube bend as recommended by bender manufacturer *onsult the factory on an application by application basis for variance. IMPROPR SLION OR IMPROPR US O PROUS SRIB RIN OR RL IMS N US PRSONL INJURY N PROPRY M. 32 WRNIN It is the sole responsibility of the system designers to properly select and use the products for their specific applications. his document has been printed for users with technical expertise as a reference for further investigation to determine specific product needs relative to design requirements.
Warranty uolok ube ittings Lifetime Limited Warranty SSP guarantees all uolok tube fittings and uolok tube fitting components to be free from defects in materials and workmanship. dditionally, SSP guarantees uolok product performance to the published catalog specifications when properly installed according to the catalog selection and installation instructions. o initiate a warranty claim, suspected defective product must be returned to SSP with the nature of potential defect documented for factory evaluation. ny product with a determined defect in material or workmanship will be replaced with equivalent product at no charge. his warranty comprises the sole and entire warranty pertaining to items provided hereunder. here is no other warranty, guarantee, express or implied representation of any kind whatsoever. ll other warranties including, but not limited to, merchantability and fitness for purpose, whether express, implied, or arising by operation of law, course of dealing, or trade usage are hereby disclaimed. here are no warranties which extend beyond the description on the face hereof; and this warranty does not apply in cases of abuse, mishandling, or normal use depreciation. In no event, whether alleged to arise from breach of contract, express or implied warranty, by operation of law, negligence or otherwise, will SSP be liable for any incidental, consequential, lost property, or other special damages of any kind whatsoever. he exclusive, only remedy under this warranty is the replacement of determined defective parts as set forth above. uolok ube ittings LIIM LIMI WRRNY ube ittings Lifetime Limited Warranty SSP guarantees all tube fittings and tube fitting components to be free from defects in materials and workmanship. dditionally, SSP guarantees product performance to the published catalog specifications when properly installed according to the catalog selection and installation instructions. o initiate a warranty claim, suspected defective product must be returned to SSP with the nature of potential defect documented for factory evaluation. ny product with a determined defect in material or workmanship will be replaced with equivalent product at no charge. his warranty comprises the sole and entire warranty pertaining to items provided hereunder. here is no other warranty, guarantee, express or implied representation of any kind whatsoever. ll other warranties including, but not limited to, merchantability and fitness for purpose, whether express, implied, or arising by operation of law, course of dealing, or trade usage are hereby disclaimed. here are no warranties which extend beyond the description on the face hereof; and this warranty does not apply in cases of abuse, mishandling, or normal use depreciation. In no event, whether alleged to arise from breach of contract, express or implied warranty, by operation of law, negligence or otherwise, will SSP be liable for any incidental, consequential, lost property, or other special damages of any kind whatsoever. he exclusive, only remedy under this warranty is the replacement of determined defective parts as set forth above. ube ittings LIIM LIMI WRRNY 33
SSP Steel ube ittings SOK N SUPPOR LOLLY BY: 8250 Boyle Parkway winsburg, Ohio 44087-2200 elephone: (330) 425-3960 ax: (330) 425-8116 www.sspfittings.com 34 RI 100% Made in the US ILSUP/000/06