USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

Similar documents
USE AND CARE GUIDE BATTERY TESTER

Model (Circuit Tester) Model (GFCI Tester)

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Autoranging Industrial Multimeter

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

True RMS Autoranging Multimeter

Autoranging Multimeter

Use and Care Guide. Item #

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

USE AND CARE GUIDE 7000 LUMEN TWIN HEAD LED WORKLIGHT WITH TRIPOD

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Non-Contact Phase Rotation Tester

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Use and Care Guide.

USE AND CARE GUIDE 2500 LUMEN LED PORTABLE WORKLIGHT

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Non-Contact Phase Rotation Tester

Use and Care Guide. Part # UC SV-D Model # UC SV-d UC SV-d

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Use and Care Guide. Part # SC SV-OS-BZ SC SV-OS-W Model #

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

Use and Care Guide. Item #

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Megohmmeter Test Probe

41210S CIRCUIT BREAKER FINDER WITH GFCI Instrucciones de uso Detector de Interruptores con GFCI 41210S. Operating Instructions

DIGITAL RCD(ELCB) TESTER

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

USE AND CARE GUIDE 9FT EZ TOUCH SOLAR BLUETOOTH UMBRELLA

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1107

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

MOTION-ACTIVATED WALL LANTERN

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

5.5 FT PRE-LIT SERBIAN SPRUCE TREE

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

System 3 ZB1PS Device Chassis. Operator s Manual

Digital/Analog Megohmmeter Model 1026 USER MANUAL

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

i3000s/i2000 Flex AC Current Probe

User Guide. Model Insulation Tester / Megohmmeter. Introduction

INSTALLATION GUIDE AND USER MANUAL

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

Electric Vehicle Charging Station

6-PACK SOLAR PATHWAY LIGHTS

USER MANUAL. Insulation Tester + DMM. Model MG320

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

1 AMP CURRENT SOURCE

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

3 PHASE TESTER & MOTOR ROTATION TESTER

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

OPERATING INSTRUCTION

LED FLUSHMOUNT CEILING FIXTURES (SET OF 4)

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

RECHARGEABLE POWER OUTAGE LED LIGHT INSTRUCTION MANUAL

HANGING LANTERN ITEM # MODEL #CP199MBK. Français p. 9. Español p. 17 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

- Wiring Brochure Zone Manager 335

82V LITHIUM-ION BATTERY CHARGER GC 400

Instruction Manual. IT-1 Infrared Thermometer

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

INSTALLATION GUIDE AND USER MANUAL

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

Utility Distribution Systems Installation, Operation, and Maintenance Manual

LED Recessed Troffer Retrofit Kit

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

USE AND CARE GUIDE 4 FT. LED WRAP LIGHT

User's Manual. Earth Ground Resistance Tester. Model Introduction

- Wiring Brochure Zone Manager 336

Heavy-Duty Probe Testers

LED FLUSHMOUNT CEILING FIXTURES

Water Valve Shutoff. WVS Water Valve Shutoff

KEWTECH. KT56 digital multi function tester. Instruction manual

FLO Home TM X5 Model. Installation Guide

Manufacturing & Service: Bierer & Associates Inc. Patent No. 6,885,180. ST Series Service Tester Phase Identifier Operating Instructions ST500PGN

AUTOMATIC SUBMERSIBLE UTILITY PUMP

ATTACH YOUR RECEIPT HERE ITEM # FT. PRE-LIT DOUGLAS FIR TREE. MODEL #DF-75C85 Español p. 8

User Guide. Model Insulation Tester / Megohmmeter

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

EVoInnovate EVSE Model Numbers: EVO & EVO User Manual & Installation Guide. Revision 1.0

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

Hybex Microsample Incubator

innovations in battery charging

Transcription:

Item # 1002 153 664 Model #CE-VD7504GFI USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER Questions, problems, missing parts? Before returning to the store, call Commercial Electric Customer Service 8 a.m. 7 p.m., EST, Monday Friday, 9 a.m. 6 p.m., EST, Saturday 1-877-527-0313 HOMEDEPOT.COM THANK YOU We appreciate the trust and confidence you have placed in Commercial Electric through the purchase of this circuit tester. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs. Thank you for choosing Commercial Electric!

Table of Contents Table of Contents... 2 Safety Information... 2 Warranty... 2 Pre-Operation... 3 Product Description... 3 Product Specifications... 3 Operation... 4 Installing or Replacing the Battery... 7 Care and Cleaning... 7 Safety Information Please read this manual carefully and pay attention to related safe working standards before using this tester. Protection provided by the instrument will be impaired if used in a manner not specified by the manufacturer. CAUTION: Do not attempt to repair this tester. It has no serviceable parts. WARNING: Use extreme caution when checking electrical circuits to avoid injury due to electric shock. The manufacturer assumes basic knowledge of electricity on the part of the user and is not responsible for any injury or damages due to improper use of this tester. SAFETY SYMBOLS Symbol Definition Indicates important safety information. WARNING: OBSERVE AND FOLLOW all standard industry safety rules and electrical codes. When necessary call a qualified electrician to troubleshoot and repair the defective electrical circuit. WARNING: To assure the unit is operating, always test on a known live circuit before use. WARNING: This product does not sense DC voltage or potentially hazardous voltages below 50 volts. Conforms to UL 1436 (Circuit Tester) UL 61010-1 & 61010-2-030 (NCV Detection) This product conforms to European Union directives. This product is double insulated, Class II safety equipment. WARNING: This tester will not detect voltages in wires that are electrically shielded by metal conduit or grounded electrical enclosures. CAUTION: Read, understand, and follow the safety rules and operating instructions of this manual before you use the product. Protection provided by the instrument will be impaired if used in a manner not specified by the manufacturer. Warranty WARRANTY: 12 months For one year from the date of purchase, this product is warranted against any defects in material or workmanship. This warranty is void if this product is ever used while providing commercial services or if rented to another person. Contact the Customer Service Team at 1-877-527-0313 or visit www.homedepot.com. 2

Pre-Operation PRODUCT DESCRIPTION Part Description Quantity A GFCI test button 1 B Circuit indicator LED panel 1 C Speaker 1 D Non-contact voltage (NCV) detection button 1 E NCV LED indicator 1 F NCV test probe 1 PRODUCT SPECIFICATIONS Component Operating range Certification and Compliance Indicators Battery Operating environment Specification 115-125 VAC, 50-60 Hz (circuit tester) and 50-600 VAC, 50-60 Hz (NCV detection) Conforms to UL 1436 (circuit tester) UL 61010-1 & 61010-2-030 (NCV detection), CE, CAT III 1000V Visual Only (circuit tester) Audible and Visual (NCV detection) One (1) LR44 32-104 F (0-40 C) 80% RH max., 50% RH above 30 C, Altitude up to 2000 meters, Indoor use, Pollution degree 2, Accordance with IED-664

Operation 1 Testing an outlet circuit NOTICE: All appliances or equipment on the circuit being tested should be unplugged to help avoid erroneous readings. NOTICE: This is not a comprehensive diagnostic instrument but a simple instrument to detect nearly all probable common improper wiring conditions. NOTICE: Refer all indicated problems to a qualified electrician. NOTICE: This tester will not: - Detect two hot wires in a circuit. - Detect a combination of defects. - Indicate a reversal of grounded and grounding conductors. Plug the tester into any 120 Volt standard or GFCI outlet. Only a single LED on the LED panel (B) should illuminate. The text adjacent to the lit LED will indicated the wiring condition. If no LED illuminates then the hot is open. If the tester indicates a wiring problem then turn off all power to the outlet and repair wiring. Then restore power to the outlet and repeat these steps. 4

Operation (continued) 2 Testing GFCI protected outlets CAUTION: GFCIs are sometimes installed in 2- wire systems (no ground wire available). This may or may not meet the local code. This tester will not trip GFCI outlets installed without a ground wire. On 2-wire systems, use the Test and Reset buttons on the GFCI outlet to demonstrate proper operation. To detect which downstream outlets are protected by the GFCI, place the tester in these outlets and use the Test and Reset buttons. Watch for the LEDs on the tester to turn off. This will indicate proper operation. NOTICE: Consult the GFCI manufacturer's installation instructions to determine that the GFCI is installed in accordance with the manufacturer's specifications. NOTICE: Check for correct wiring of the receptacle and all remotely connected receptacles on the branch circuit. NOTICE: Operate the test button on the GFCI installed in the circuit. The GFCI must trip. If it does not do not use the circuit consult an electrician. If the GFCI does trip, reset the GFCI. Then, insert the GFCI tester into the receptacle to be tested. To test GFCI protected circuits, plug the tester into a GFCI protected outlet. Verify the power is on and that the outlet is wired properly. Press the GFCI test button (A). Activate the test button (A) on the GFCI tester for a minimum of 6 seconds when testing the GFCI condition. Visible indication on the GFCI tester must cease when tripped. If the circuit is wired properly, the main GFCI outlet should trip and power to the circuit will be cut off (this is indicated by the LED lights (B) on the tester going off). If the tester fails to trip the GFCI, it suggests: A wiring problem with a totally operable GFCI, or Proper wiring with a faulty GFCI. Consult with an electrician to check the condition of the wiring and GFCI. Homedepot.com 5 Please contact 1-877-527-0313 for further assistance.

Operation (continued) 3 Testing non-contact voltage (NCV) NOTICE: Static Electricity The tester is subject to electrical static interference. If the LED or tone activate momentarily it is detecting static electricity. When detecting voltage the LED and tone will cycle continuously. NOTICE: NCV detection antennae interference The presence of objects near the probe tip can decrease the sensitivity of the tester. Keep your finger away from the LED lens and probe tip to ensure adequate detection range. Before use, test the battery by pressing the NCV detection button (D). The LED (E) will flash and the speaker (C) will chirp momentarily if the battery is good. If the indicators do not function or the chirp continually cycles, then replace the battery. To test for voltage press and hold the NCV detection button (D). Place the probe tip (F) on or near the wire, device, or circuit to be tested. If AC voltage greater than 50 VAC is present the LED (E) will flash and the speaker (C) will chirp continuously. 6

Installing or Replacing the Battery This tester comes complete with one LR44 battery in the package. When replacing, always replace with another LR44 battery. To install or replace the battery: 1. Orient the tester backside up and use a small Phillips screwdriver to remove the battery compartment cover (marked with the battery symbol). 2. Remove the LR44 battery. Use caution to prevent damage or injury to the internal components. 3. Place the new battery into the tester as shown on the battery cover with the positive terminal facing toward the NCV end. 4. Replace battery cover and screw. 5. Test on a known live circuit to verify tester functionality. Care and Cleaning Periodic maintenance of this instrument is not required. However, should the unit require cleaning, wipe it with a soft, dry cloth. Do not store the tester in excessively hot, humid, or damp places. Homedepot.com 7 Please contact 1-877-527-0313 for further assistance.

Questions, problems, missing parts? Before returning to the store, call Commercial Electric Customer Service 8 a.m. 7 p.m., EST, Monday Friday, 9 a.m. 6 p.m., EST, Saturday 1-877-527-0313 HOMEDEPOT.COM Retain this manual for future use. 8