If you have any questions, please do not hesitate to contact the Board's Legal Counsel, Ms. Jacqui Glynn, via or (709)

Similar documents
Ms. Tracey Pennell Senior Counsel Newfoundland and Labrador Hydro P.O. Box St. John's, NL A1B 4K7

Mr. Geoffrey Young Newfoundland and Labrador Hydro P.O. Box St. John's, NL AIB 4K7.

We trust the foregoing is satisfactory. If you have any questions or comments, please contact the undersigned.

Attention : Ms. G. Cheryl Blundon, Director of Corporate Services & Board Secretary

PRESS RELEASE June 25, 2004

NEWFOUNDLAND AND LABRADOR BOARD OF COMMISSIONERS OF PUBLIC UTILITIES AN ORDER OF THE BOARD NO. P.U. 17(2017)

TEN YEAR PLANNING GUIDE SHASTA LAKE ELECTRIC UTILITY

ro a nalcor energy company

PUB NLH 174 Island Interconnected System Supply Issues and Power Outages Page 1 of 4

PR-PUB-NLH-034 NLH 2015 Prudence Review Page 1 of 1

March 31, 2014 VIA HAND DELIVERY & ELECTRONIC MAIL

Max value Max life Range from. ($000) (Years) Pole Type

A REPORT TO THE BOARD OF COMMISSIONERS OF PUBLIC UTILITIES. Electrical. Mechanical. Civil. Protection & Control. Transmission & Distribution

SECTION 9: ELECTRICAL POWER DISTRIBUTION. ESE 470 Energy Distribution Systems

BC HYDRO SUPPLY CHAIN APPLICATIONS PROJECT EXHIBIT A-8

Review of Electric Utility Hurricane Preparedness and Restoration Actions ORLANDO UTILITIES COMMISSION RESPONSES TO STAFF'S SECOND DATA REQUEST

Insulator Replacements

Feasibility Study. Shaw Environmental, Inc. 12MW Landfill Gas Generation Interconnection. J.E.D. Solid Waste Management Facility. Holopaw Substation

Power Infrastructure. PowerToGrowPHX.com

Energy storage - two Canadian Case Studies ESA Annual Conference, Washington, June 4th. Alex Bettencourt Managing Director

Attention: Ms. Cheryl Blundon Director Corporate Services and Board Secretary

Texas A&M Microgrid and Electrical System Study. Cushing Memorial Library & Archives


Title Electrical Technical Maintenance Coding System. Reference Number PMP 01 (RIC Standard: EP SP)

ElectricCourseCatalog.

National Certificate in Electricity Supply (Sub Station Maintainer) (Level 4)

Generation Interconnection Facilities Study For

3.0 Radial Distribution Systems

(a) Is the cost of the TL from Labrador included in the $214 /MWH?

Decision D ATCO Electric Ltd. Decommissioning of Transmission Line 6L82

Agility in energy Ahead of the challenge, ahead of the change

FISCHER, FRANKLIN & FORD Attorneys and Counsellors GUARDIAN BUILDING, SUITE GRISWOLD STREET DETROIT, MICHIGAN

An Inside Look at Electric Reliability 2016 Electric Reliability Report

Transformer Protection

NEWFOUNDLAND AND LABRADOR HYDRO. Glossary of Terms

Network. ENMAX Power Corporation Network Planning & Design November 4, 2011

Included in this Stakeholder Information Package:

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Condition of Approval Building Standards Development Planning Engineering TRCA PowerStream Ministry of Transportation Other -

Sectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications

A REPORT TO THE BOARD OF COMMISSIONERS OF PUBLIC UTILITIES. Electrical. Mechanical. Civil. Protection & Control. System Planning

STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS ENERGY FACILITY SITING BOARD

Re: California Independent System Operator Corporation

DELIVERED BY HAND. December 19, Board of Commissioners of Public Utilities P.O. Box Torbay Road St. John's, NL A1A 5B2

Smart Grid Automation and Centralized FISR

Modular integrated transportable substation (MITS)

Public Service Bodies Rebate for Qualifying Non-profit Organizations Resident Only in Newfoundland and Labrador

Utility Distribution Planning 101

IN THE MATTER OF the Ontario Energy Board Act, 1998, S.O. 1998, c.15, Schedule B;

Pacific Gas and Electric Company TM

SPP Notification to Construct

Building a 21 st Century Electric Grid. February 23, 2018

Alameda Point Electric Infrastructure Improvements Public Utilities Board Update May 15, 2017

Net Metering Interconnection Requirements

Q. Are you familiar with the matter which is the subject of this petition? A. Yes, I am.

IEEE Guide for the Design of Low Voltage AC and DC Auxiliary Systems for Substations

MeteorCalc SL. MeteorCalc SL is a CAD plugin for designing street lighting networks.

Welcome To Citizens Electric

NEW YORK CITY TAXI AND LIMOUSINE COMMISSION. Notice of Public Hearing and Opportunity to Comment on Proposed Rules

CONNECTION ASSESSMENT & APPROVAL PROCESS. Cardinal Substation Modification of 115kV Substation

EE064D: Circuit Breakers & Switchgears: Design, Testing, Commissioning, Maintenance, Repair & Troubleshooting

MIPSYCON 2014 Can a Grid be Smart without Communications? A Look at an Integrated Volt Var Control (IVVC) Implementation

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS

Generator Interconnection System Impact Study For

TRANSMISSION PLANNING CRITERIA

BC Hydro Case Study: Battery Energy Storage in Field, British Columbia, Canada. IEEE PES Meeting July 2014

TRANSFORMER REPLACEMENT

One-Fit,UFES, Reyrolle LM

Solar Development in New Jersey, and PV Impacts on the Distribution System Carnegie Mellon Conference on the Electricity Industry - March 9, 2011

SPP Notification to Construct with Conditions

Public Service Bodies Rebate for Charities Resident in Two or More Provinces, at Least One of Which Is a Participating Province

S C ELECTRIC EUROPE LTD. Excellence Through Innovation. Harnessing the Wind. November 2011 Descriptive Bulletin E

South Carolina Electric and Gas Company Planned Transmission Projects $2M and above Total 5 Year Budget

EH2741 Communication and Control in Electric Power Systems Lecture 3. Lars Nordström Course map

STATE OF NORTH CAROLINA UTILITIES COMMISSION RALEIGH NOTICE TO CUSTOMERS DOCKET NO. E-34, SUB 46 BEFORE THE NORTH CAROLINA UTILITIES COMMISSION

South Carolina Electric and Gas Company Planned Transmission Projects $2M and above Total 5 Year Budget

SWITCHGEAR DIVISION PRODUCT PROFILES

1SPP Notification to Construct. RE: Notification to Construct Approved Reliability Network Upgrades

EDS FUSE RATINGS AT DISTRIBUTION SUBSTATIONS

MICROGRIDS DESIGNING AN IMPROVED GRID

Brion Energy Corporation

and Board Secretary Newfoundland and Labrador Hydro 2017 Capital Budget Application Revision

FORTISBC INC. PRUDENCY REVIEW KETTLE VALLEY SUBSTATION EXHIBIT A2 5

Small Generator Interconnection Program Interconnection Technical Requirements

V-NLH-005 Voisey's Bay Terminal Station - VBN T1 Page 1 of 1

Northeast Wisconsin/Upper Peninsula Separation 11/14/01. Incident Investigation Report

OEB's Appendix 2-B: Fixed Asset Continuity Schedule

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016

August 26, Project No Holt Project Turbine and Generator Nameplates by electronic filing

Ms. Sandra Squire, Executive Secretary West Virginia Public Service Commission Post Office Box 812 Charleston, West Virginia 25323

Title High Voltage and 1500 System Earthing References and Definitions. Reference Number PDS 02 (RIC Standard: EP SP)

Reliability Analysis Update

ELECTRIC SYSTEM RELIABILITY ANNUAL REPORT

CITY OF COCOA BEACH RECLAIMED WATER AQUIFER STORAGE AND RECOVERY (ASR) SYSTEM CYCLE TESTING SCOPE OF SERVICES AND FEE ESTIMATE

BC HYDRO REAL TIME OPERATIONS DISTRIBUTION OPERATING ORDER 1D-23. PERMIT FOR ENTRY INTO CABLE MAN HOLES Supersedes 1D-23 issued 29 February 2016

SPP Notification to Construct

Net Metering Interconnection Requirements. Customer Generation Capacity Not Exceeding 100 kw. Date: Version: 1

Recent Trades in Distribution System

Director Corporate Services & Board Secretary. Newfoundland and Labrador Hydro 2015 Capital Budget Application

Rogers Road to Clubhouse 230kV New Transmission Line April 1, 2016

Transcription:

NEWFOUNDLAND AND LABRADOR BOARD OF COIIIIISSIONERS OF PUBLIC UTILITIES 120 Torbay Road, P.O. Box 21040, St. John's, Newfoundland and Labrador, Canada, AlA 5B2 E-mail: gyoung@nlh.nl.ca 2014-0-12 Mr. Geoffiey Young Newfoundland and Labrador Hydro P.O. Box 12400 St. John's, NL A1B 4K7 Dear Sirs: Re: Newfoundland and Labrador Hydro - the Board's Investigation and Hearing into Supply Issues and Power Outages on the Island Interconnected System - Requests for Information. Enclosed are Information Requests PUB-NLH-082 to PUB-NLH-108 regarding the abovenoted matter. The deadline for filing the responses to the Requests for Information is Thursday, March 20, 2014. If you have any questions, please do not hesitate to contact the Board's Legal Counsel, Ms. Jacqui Glynn, via jgylnn@pub.nl.ca or (709) 726-6781. Yours truly, Bobbi Sheppard Assistant Board Secretary Encl. ecc. Newfoundland Power Inc. Mr. Gerard Hayes, E-mail: ghayes@newfoundlandpower.com Ian Kelly, QC, E-mail: ikelly@curtisdawe.com Consumer Advocate Mr. Thomas Johnson, E-mail: tjohnson@odeaearle.ca Ms. Colleen Lacey, E-mail: clacey@odeaearle.ca Island Industrial Customer Group Mr. Paul Coxworthy, E-mail: pcoxworthy@stewartmckelvey.com Mr. Dean Porter, E-mail : dporter@pa-law.ca Mr. Danny Dumaresque Mr. Danny Dumaresque, E-mail: danny.liberal@gmail.com Bobbi Sheppard Assistant Board Secretary, Tel: 709-726-047, E -Mail: bsheppard@pub.nl.ca Website: www.pub.nl.ca

1 INTHEMATTER OF 2 the Electrical Power Control Act, 1994, SNL 1994, Chapter E-5.1 (the "SPCA") 4 and the Public Utilities Act, RSNL 1990, 5 Chapter P-47 (the "Act"), as amended; and 6 7 IN THE MATTER of the Board's Investigation 8 and Hearing into Supply Issues and Power Outages 9 on the Island Interconnected System. PUBLIC UTILITIES BOARD REQUESTS FOR INFORMATION PUB-NLH-082 to PUB-NLH-108 Issued: March 12, 2014

2 1 PUS-NLH-82 Please provide electronic documents describing terminal station 2 equipment and relay inspection, testing, and maintenance programs and practices. These documents should describe the activities to be conducted 4 5 6 7 PUB-NLH-8 8 9 10 PUB-NLH-84 11 12 1 14 15 16 PUB-NLH-85 17 18 19 20 21 22 PUB-NLH-86 2 24 25 PUB-NLH-87 26 27 28 29 0 1 PUB-NLH-88 2 4 5 PUB-NLH-89 6 7 8 9 40 41 PUB-NLH-90 42 4 44 PUB-NLH-91 45 46 by equipment type, the time period between time-based activities, and what triggers condition-based activities. Please describe how terminal station equipment repairs are prioritized and state the repair-by time limits for each prioritization. Please provide documents stating terminal station equipment and relay equipment backlogged jobs, indicating the number of inspection, within time limits per program priorities) at the end of 2011, 2012, and 201. Explain why the backlogs occurred. Please provide electronic documents describing transmission pole and line equipment inspection, testing, and maintenance programs and practices. These documents should describe the activities conducted by equipment type, the time period between time-based activities, and what triggers condition-based activities. Please describe how transmission line equipment repairs are prioritized and state the time limits for each prioritization. Please provide documents indicating backlogged transmission line, pole, and equipment backlogs, indicating the number of inspection, within time limits per program priorities) at the end of 2011, 2012, and 201. Please provide the total number of wood transmission poles on the system and the number of transmission poles which have been replaced over the last 5 years. Please provide electronic copies of documents describing distribution substation equipment and relay inspection, testing, and maintenance programs and practices. These documents should describe the activities to be conducted by equipment type, the time period between time-based activities, and what triggers condition-based activities. Please describe how distribution substation equipment repairs are prioritized and state the repair-by time limits for each prioritization. Provide documents indicating distribution substation equipment and relay equipment backlogged work, indicating the number of inspection,

1 within time limits per program priorities) at the end of 2011, 2012, and 2 201. Explain why the backlogs occurred. 4 PUB-NLH-92 Please provide electronic documents describing overhead and 5 underground distribution mainline and URD feeder inspection, testing, and 6 maintenance programs and practices. These documents should describe 7 the activities to be conducted by equipment type, the time period between 8 time-based activities, and what triggers condition-based activities. 9 10 PUB-NLH-9 Please describe how overhead and underground feeder distribution 11 mainline and URD feeder equipment repairs are prioritized and state the 12 repair-by time limits for each prioritization. 1 14 PUB-NLH-94 Please provide documents indicating overhead and underground 15 distribution feeder and URD equipment backlogged work, indicating the 16 number of inspection, maintenance, testing, and repair jobs that were 17 backlogged (not completed within time limits per program priorities) at 18 the end of 2011, 2012, and 201. Explain why the backlogs occurred. 19 20 PUB-NLH-95 Please provide the numbers of subtransmission and distribution wood 21 poles on the system. How many subtransmission and distribution poles 22 have been replaced over the last 5 years? 2 24 PUB-NLH-96 Please provide the total numbers of air-blast circuit breakers on the system 25 by voltage levels. 26 27 PUB-NLH-97 Please provide the current estimated cost, by voltage level, to replace an 28 air-blast circuit breaker with a new SF6 circuit breaker. 29 0 PUB-NLH-98 Please provide the number of air-blast circuit breakers which have been 1 replaced to date, by voltage level, with SF6 circuit breakers. Describe the 2 current plans for replacing air-blast circuit breakers in the future. 4 PUB-NLH-99 Please provide the type and numbers of other terminal station equipment, 5 other than air-blast circuit breakers, that has been replaced over the last 10 6 years and plans for replacing such equipment in the future. 7 8 PUB-NLH-100 Please provide the amount spent on protective relay replacements in the 9 last 5 years for the transmission, subtransmission, and distribution 40 systems. 41 42 PUB-NLH-101 Please provide numbers of transmission terminal stations on the system 4 (high side at 20kV or 18kV), the numbers of distribution substations 44 (low side supplying distribution system), and the miles of, and numbers of 45 circuits, transmission, subtransmission, and distribution lines by voltage.

4 1 PUB-NLH-102 Please provide the extent the transmission and distribution substations are 2 SCADA controlled and monitored. 4 PUB-NLH-10 Please describe the extent that distribution feeders have automatic circuit 5 reclosers on the feeders downstream from the substations. Provide the 6 percentage of reclosers that are SCADA controlled. 7 8 PUB-NLH-104 Please describe the extent that lateral taps off of mainline distribution 9 feeders are fused. 10 11 PUB-NLH-105 Please describe the company's reliability enhancement programs and 12 practices. Describe reliability work completed over the last 5 years and 1 what is planned for the future_ 14 15 PUS-NLH-106 Please provide the numbers of skilled workmen by type and duties, for 16 each of the last 5 years, for transmission line work, substation work, and 17 distribution work. 18 19 PUB-NLH-107 Please provide the numbers of relay and control engineers in the company, 20 and the numbers of relay technicians working for the company for each of 21 the last five years by location. 22 2 PUB-NLH-108 Please describe the protective relay work which has been completed in 24 response to the Henville Consulting recommendations provided in 2010, 25 2011, and 201. What relay work is planned? DATED at St. John's, Newfoundland this 12 th day of March 2014. BOARD OF COMMISSIONERS OF PUBLIC UTILITIES