Powered by Doosan P086TI 250KVA at 60Hz, 220V General feature: Assembled by Doosan diesel engine and Leroy Somer alternator. Three filters as standard, fuel and water separator as optional. Radiator and fan with safety guard. Single bearing alternator IP 23, Insulation Class H. Heavy duty steel as base frame and 8hrs operation base fuel tank. Automatic control panel and 3 poles circuit breaker, internal cable. 12V or 24V battery, battery wires. Battery charger and float battery charger as standard supply scope. Optional soundproof canopy, ATS, synchronization panel, movable trailers. Genset Main Technical Data: Genset Model Prime Power(60HZ) Standby Power(60HZ) Frequency/Speed Standard Voltage Voltage Available Phases Wires SD250 180KW/225KVA 200KW/250KVA 60Hz/1800rpm 127V/220V Three phases Four Wires (1) PRP: Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO8528-1. A 10% overload capability is available for a period of 1 hour within 12-hour period of operation. In accordance with ISO 3046-1. (2) ESP: The Standby Power Rating is applicable for supplying emergency power in variable load applications for up to 200 hours per year in accordance with ISO8528-1. Overload is not allowed.
Doosan Engine Data: Manufacturer Doosan Engines Company Limited Model P086TI Engine speed 1800rpm Engine power ----------------------------Standby power 223KW ----------------------------Prime power 205KW Type 4 stroke cycle, Vertical in-line, 6 cylinder Aspiration Turbo charged & intercooled (air to air) Bore * Stroke 111*139 mm Cubic capacity 8.071 L Compression ratio 16.4:1 Fuel Consumption: Load Type of operation and application g/kwhr l/hr Standby 56.8 Prime 50.6 75% prime 37.7 50% Prime 25.1 25% Prime 13.8
Lubrication system: ㅇLub. Method ㅇOil pump ㅇOil filter ㅇOil pan capacity Fully forced pressure feed type Gear type driven by crankshaft Full flow, cartridge type High level 15.5 liters ( 4.09 gal.) Low level 12 liters ( 3.17 gal.) ㅇ Angularity limit Front down 25 deg Front up 25 deg. Side to side 25 deg. Fuel system: ㅇInjection pump Zexel in-line A type ㅇGovernor ㅇFeed pump ㅇInjection nozzle ㅇOpening pressure ㅇFuel filter ㅇUsed fuel Zexel in-line P type Electric type Mechanical type Multi hole type 224 kg/cm2 (3.186 psi) Full flow, cartridge type Diesel fuel oil Cooling system: ㅇCooling method ㅇWater capacity (engine only) ㅇPressure system ㅇWater pump Fresh water forced circulation 14 liters ( 3.70 gal.) Max. 0.9 kg/cm2 ( 12.8 psi) Centrifugal type driven by belt ㅇ Thermostat Wax pellet type Opening temp. 71 C Full open temp. 85 C ㅇ Cooling fan Blower type, steel 660.4 mm diameter, 7 blade Electric system: ㅇ Charging generator starter motor 24V x 45A alternator 24V x 6.0kW
ALTERNATOR Specifications: Manufacturer Leroy-somer Electro-technique (Fuzhou) Company Ltd. Model LSA46.2M5 Output power 184KW AVR model R250 Number of phase 3 Power factor (Cos Phi) 0.8 Altitude 1000 m Overspeed 2250RPM Number of Pole 4 Exciter type Shunt Insulation class H Voltage regulation ±1% Sustained short circuit current 300% (3 IN) : 10s Total harmonics (TGH/THC) no load < 3% - on load < 2% Wave form : NEMA = TIF < 50 Wave form : I.E.C. = THF < 2% Bearing single Circuit breaker specification: Manufacturer Brand Delixi group Delixi Model DZ20Y-800/800 3300 Capacity 800amp Voltage Starting Battery specification: Battery Voltage Battery Capacity Quantity Battery type 12V 200AH 2pcs maintaince-free battery
Control system: Deepsea 6020 5 Auto start and stop control panel 4 3 2 1 Deepsea 6020 is an auto mains failure controller for single generator, it can monitor and protect the generator working all the time. it has a LCD display which clearly shows the status of the engine. this controller include seven inputs and six outputs. This controller can also be programmed using the frong panel or by using DSE configuration Suite PC software. Parameters: This controller can provide Generator frequency, Under/over speed, Generator volts, Generator current, Engine oil pressure, Engine coolant temperature, Flexible fuel level, Hours run counter, Battery volts, Fail to start/stop, Emergency Stop. Failed to reach loading voltage/frequency, Charge fail, Loss of magnetic pickup signal, Low DC voltage, CAN diagnostics and CAN fail/error, Mains volts 3 phase, Mains frequency, AMF indications Protection: Low Oil Pressure High water Temperature High voltage and low voltage Overspeed Volt adjuster and frequency adjuster. Emergency stop Fail to start Features: Protection: Automatic start/stop, load transfer and alarming of generator; CAN and magnetic pick-up versions. PC and front panel configurable 4 digital inputs and 3 analogue inputs. 6 outputs(4 configurable on magnetic pick-up, 6 configurable on Canbus version). 3 phase generator and mains voltage monitoring. remote start on or off load. advanced metering capability. test button. protected solid state outputs. transfer between mains and generator power. user-friendly set-up and button layout. multiple engine parameters are monitored simultaneously. module can be configured to suit individual applications. IP 65 rating offers advanced resistance to water ingress when gasket is fitted. 1 Power switch 2 Lamp switch 3 Power indicator 4 Operation buttons 5 LCD display Open type
Supply scope 1.Standard supply scope: 5 3 7 Exhaust silencer 1 2 8 Starting battery 9 Float battery charger 6 5 4 10 Flange 2. Optional supply scope: 1 Auto Control Panel 2 Main Ciruit Breaker 3 Cooling Radiator 4 Base Frame 5 Filter 6 Starting Motor 1 ATS 2 fuel and water separator 3 Auto Fuel Pump 4 External daily fuel tank 5 ABB Breaker 6 Synchronization System 7 Lub oil heater 8 Elec.coolant Heater 9 Oil drain Pump 10 Trailer & Silent Canopy