Compliance with CE Marking and UL Standard

Similar documents
Industrial Inverter (For 3-phase motors)

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U

E a. Inverter Application Manual. Leakage Current

CRegulatory. Compliance: UL and CE APPENDIX C IN THIS CHAPTER. Installation Instructions Installation Guidelines System Installation Techniques

Synergy EN product information

DRL-1 Series Instruction Manual

DRB-1 Series Instruction Manual

Braking unit Option Instruction Manual PB7-4132K

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

FE100/FE200. Inverter

Solid State Relays contactor with Integrated Fuse Type RGC1F

Solid State Relays, 3-phase

Model Number Structure

Three-Phase Soft Starters

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

Single & Three-Phase Soft Starters

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

LS200 Series Instruction Manual

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

J1000. Compact Inverter Series.

APEX DRIVE USER GUIDE ADDENDUM: LVD INSTALLATION INSTRUCTIONS

Max. Output Power. Efficiency (1) 110Vac 220Vac. 450 ma 90 ~ 305 Vac 445 Vdc 200 W 92% EUC-200S045ST

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

MODEL CUB7 MINIATURE ELECTRONIC 8 DIGIT COUNTER or TIMER

INDUSTRIAL POWER SUPPLIES SFL-SERIES

Filtered PWM Speed Control for Permanent Magnet DC Motors

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

199.9 µa to A *, mv (AC or DC) * Accessory Shunts Available For Higher Current Ranges.

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

DC power supply connect to VF-AS1/PS1 Optional initial charger MCR-2550 Instruction manual

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

MINI MCR-SL-UI-UI(-SP)(-NC)

Output Voltage Range. Parameter Min. Typ. Max. Notes. Input Voltage 90 Vac Vac 127~300 Vdc

DIN EN UL 508 / CSA 3RF A A 0 2

Series P215ST Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Safety Standards. Model Number:

SOLSTART Instruction Manual

DC POWER SUPPLY ALIMENTATION C.C.

ACCESSORIES. Fuse Specification Chart

Industrial Power Supplies

PM500. Voltage Regulator User Manual. A Regal Brand. Scan here for other languages.

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

80 Series V Digital Multimeter Safety Information

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

M-50/55 Series. Fixed setting flow switch with in-line flow

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

KBAC SERIES Adjustable Frequency Drives for 3-Phase AC Motors NEMA-4X / IP-65

Newsletter C F a m i l y A c c e s s o r i e s L a u n c h A n n o u n c e m e n t

199.9 A to A *, mv (AC or DC) * Accessory Shunts Available For Higher Current Ranges (104.1)

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Test report. Type VRLTC load tap changer VRLTC 1500A Type test summary report

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

MINI MCR-SL-UI-UI(-SP)

RKⅡSeries Pulse input type

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

TDBU Series Dynamic brake unit user manual

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

This instruction manual must be read carefully and should be always given to the end user of the device.

Index. Index...pag.1. General features...pag.2 Mechanical features Available size. Electrical features pag.3 Protections Signalling Led

TI23 Pre-Instructional Survey

HIB Enclosed Inverter User Guide

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

Manual Supplement. For IEC V, CAT I & 600, CAT II Meters only. Serial NO and greater.

Solid state DC Motor reverser SGRD This product was designed with an evolutionary spirit, other possibilities on request :

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Power thyristor units. 460 series. Control of single-phase resistive and inductive loads. User Manual

Series P255MM/ML Single/Dual Pressure Input Condenser Fan Speed Controllers For Three Phase Motors (incl. built-in RFI suppression filter)

Chapter 1: Getting Started User Manual Overview...1 2

J1000 D E F I 1000 J1000 J1000 J1000 J1000

SPECIFICATIONS SRF SuperchargerPlus

Dimensions WxHxD [mm] Weight [kg]

RVS-AX Instruction Manual

USB3.0 For Active Optical Cable SPECIFICATIONS

USB3.0 for Active Optical Cable

EMC and Power Quality. Three-phase filters FN FN FN 3025/FN FN FN FN FN FN

Open Frame Power Supplies

Brushless DC motor and driver package BX Series

Recommended Practices for Installation for EC Directive 2014/30/EU Relating to EMC

Declaration of Conformity

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Microswitches M series

YASKAWA AC Drive T1000A

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

USB3.0 For Active Optical Cable SPECIFICATIONS

Brushless DC Motor and Driver Package BLF Series

Power Supplies. POWER SUPPLIES AC to 24VDC Regulated Primary Switching. TRANSIENT VOLTAGE SUPPRESSORS Industrial Design MINI UNIVERSAL MOUNT

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

Instruction manual with V3 motor

INSTALLATION INSTRUCTIONS

Transcription:

INVERTER INSTRUCTION MANUAL Compliance with CE Marking and UL Standard VF-A7 VF-A7 200V class 400V class NOTICE 1. Make sure that this Instruction Manual is delivered to the end user of the inverter unit. 2. Keep this manual before installing or operating the inverter unit, and store it in a safe place for reference. Toshiba Schneider Inverter Corporation 2001 All rights reserved.

INDEX Compliance with CE Marking Abstract EMC directive Compliance with EMC directive Low Voltage directive Compliance with Low Voltage directive Compliance with UL Standard Compliance with Installation Compliance with Connection Compliance with Peripheral devices Compliance with Motor overload protection - 1 -

Compliance with CE Marking 1.1. Abstract In Europe, EMC directive is enforced starting 1 st Jan. of 1996, and Low Voltage Directive starting 1 st Jan. of 1997. The display of CE mark that demonstrates that products imported to European Union conform to these directives is required. Inverter itself cannot function alone, but is de-signed as a component in order to control machines or equipment which includes that inverter installed in a cubicle. Therefore the conformance to EMC directive is not required on inverter it-self. But since the object of the Low Voltage directive is equipment that is designed to be used with rated voltage of 50 to 1,000 VAC or 75 to 1,500 VDC, CE should be marked on inverter as to the Low Voltage directive. But CE has to be marked on the final product installing inverters, that conforms to the EMC directive and the Low Voltage directive. And the product also may conform to Machine directive. The user that makes the final products have to take the responsibility for Marking of CE. For that reason, we recommend installation for Low Voltage directive and measurement for EMC directive, so that the products including our inverter should conform to the EMC and Low Voltage directive. We carried out Approval testing and confirmation testing on representative models under the circumstances based on installation and measurement so that our products should conform to each directive. But we cannot confirm the conformance of the user s products to the EMC directive. Since EMC environment changes according to the construction of the cubicle and the relation of other installed electric equipment and the condition of wiring and installation, please confirm the conformance to the EMC directive for the final products on your side. - 2 -

1.2. EMC directive An inverter itself is not an object of CE marking. A machine which consists of an inverter and a motor is an object of CE marking. The EMC directive includes the emission section and the immunity section. VF-A7 can conform to EMC directive by means of installing the recommended EMI noise filter to the input side, and wiring properly. Emission: Emission of electromagnetic wave and electromagnetic interference Immunity: Resistance to electromagnetic interference [EMC directive] 89/336/EEC Table 1 Relative standard Noise type Test item Standard Applicable standards Emission Conducted Emission EN55011 Group 1 class A Radiated Emission EN55011 Group 1 class A Electrostatic Discharge IEC61000-4-2 EN61800-3 Radiated Electromagnetic field IEC61000-4-3 Immunity Electrical Fast Transient/Burst IEC61000-4-4 Surge Immunity IEC61000-4-5 Conducted Disturbances IEC61000-4-6 Voltage dips, short interruptions IEC61000-4-11 and voltage variations - 3 -

1.3. Compliance with EMC directive The model, noise filter inside (1) 200V class : 400V class : The above mentioned models install EMI noise filter inside. So the conducted and radiated noise can be reduced, optional EMI noise filters are not needed. (The additional noise filter should be installed, when more effective reduction is required.) (2) Set the carrier frequency at 4kHz or less. Title Parameter Adjustment range Default setting Setting value PWM carrier frequency 0.5 15kHz 12kHz 4kHz or less (3) The main cables such as input to the EMI filter and output of the inverter and the signal cables should be shielded, then cable length should be wired as short as possible. The main input cable should be separated from the main output cable, and cables for control signal also should be separated from main cables, not wiring parallel and not bundling, cross the wires where necessary. (4) Install EMI filter and inverter on the same metal back plate in an inverter panel. The metal back plate or the cubicle must be grounded absolutely, by using short thick wires, separated from the main cables. (5) Shielded cables should be grounded on the metal back plate in order to reduce the radiated noise from the other cables. It is an effective measure that shielded cables are grounded close to the inverter or/and operation panel or/and EMI filter(less than 10cm). (6) Installation of the zero-phase and/or the ferrite core can also effectively reduce the radiated noise further.(input or/and output of inverter) Ex. Countermeasure main circuit wiring Shielded cable Note 1) Refer to P.7. Separate input and outputs cables. Do not run input cables along-side output cables. Do not bundle input and output cables. Connect to the power source Fig. 1-4 -

The models without EMI filters (1) 200V class : VFA7-2110P 2900P1 400V class : VFA7-4185P 4280KP1 Recommended EMI noise filters(refer to Table 2) should be installed to the input. These can reduce the conducted and radiated noise. Table 2. Recommended EMI filter selection 3-phase 200V class 3-phase 400V class Type form Filter type Type form Filter type (NOTE) VFA7-2110P FN258-75/34 VFA7-2150P FN258-100/35 VFA7-2185P FN258-100/35 VFA7-4185P FN258-42/07 VFA7-2220P FN258-100/35 VFA7-4220P FN258-55/07 VFA7-2300P FN258-130/35 VFA7-4300P FN258-75/34 VFA7-2370P1 FN258-180/07 or FN3258-180/40 VFA7-4370P1 FN3258-75/52 or FS5992-72/52 VFA7-2450P1 FN258-130/35 2P or FN258-250/07 or FN3359-250/28 VFA7-4450P1 FN258-100/35 or FN3258-100/35 VFA7-2550P1 FN258-130/35 2P or FN258-250/07 or FN3359-250/28 VFA7-4550P1 FN3258-130/35 or FS5992-130/35 VFA7-2750P1 FN359-300/99 or FN3359-320/99 VFA7-4750P1 FN258-180/07 or FN3258-180/40 VFA7-2900P1 FN359-400/99 or FN3359-400/99 VFA7-4110KP1 FN359(H)-250/99 or FN3359(HV)-250/28 VFA7-4132KP1 FN359(H)-300/99 or FN3359(HV)-320/99 VFA7-4160KP1 FN359(H)-400/99 or FN3359(HV)-400/99 VFA7-4220KP1 FN359(H)-500/99 or FN3359(HV)-500/99 VFA7-4280KP1 FN359(H)-600/99 or FN3359(HV)-600/99 Note) FN258,3258 480V or less FN359 400V or less, FN359H 520V or less FN3359 500V or less, FN3359HV 690V or less (2) The main cables such as input to the EMI filter and output of the inverter and the signal cables should be shielded, then cable length should be wired as short as possible. The main input cable should be separated from the main output cable, and cables for control signal also should be separated from main cables, not wiring parallel and not bundling, cross the wires where necessary. (3) Install EMI filter and inverter on the same metal back plate in an inverter panel. The metal back plate or the cubicle must be grounded absolutely, by using short thick wires, separated from the main cables. (4) Please separate input cable to EMI filter from output cable as much as possible. (5) Shielded cables should be grounded on the metal back plate in order to reduce the radiated noise from the other cables. It is an effective measure that shielded cables are grounded close to the inverter or/and operation panel or/and EMI filter(less than 10cm). (6) Installation of the zero-phase and/or the ferrite core can also effectively reduce the radiated noise further.(input or/and output of inverter) - 5 -

Ex. Countermeasure main circuit wiring EMI FILTER Inverter panel (metal) Note 1) Refer to P.7. Separate input and outputs cables. Do not run input cables alongside output cables. Do not bundle input and output cables. Shielded cable Fig. 2 IM - 6 -

Note 1) Process as shown below. Shielded cable Strip the coating of the cable and fix the shielded part to the metal plate using a metal fitting. Fig. 3 Operating with external signals To operate with external signals, process as following figures. Ferrite core 1 Control circuit terminal Note 1) Shielded cable or Note 2) Potentiometer Forward Reverse Fig. 4 Accessories for countermeasure - Ferrite core 1 : Chomerics Type form/hbfe-1004-as (or TDK co. ltd. Type form/ ZCAT3035-1330) - Note 1) Shield : SUMITOMO 3M Co. Ltd. Electro-magnetic guard shielded sleeve Type form/ DS-5,7,10,14 - EMI filter : SCHAFFNER ELEKTRONIK AG Type form/ FN258/FN3258/FN359/FN3359/FS5992 - Zero-phase reactor : Soshin Electric Co. Ltd. Type form/ RC5078 or RC9129-7 -

1.4. Low voltage directive Inverter itself is an object of the CE marking. The Low Voltage Directive defines the safety of the electric equipment. VF-A7 series conform to the Low Voltage directive based on EN50178. Normative standard : EN50178/Electronic equipment for use in power installation Pollution degree :2(5.2.15.2) Over-voltage category : 3 200V class 3.0 mm (5.2.16.1) 400V class 5.5 mm (5.2.16.1) EN50178 provides that for electronic equipment used in power installations. The main intention is to stipulate minimum requirements for the design and manufacture of electronic equipment, for protection against electric shock, for testing and for the integration into systems for power installations. - 8 -

1.5. Compliance with Low voltage directive Please carry out the below mentioned countermeasures for the Low Voltage Directive in case of using VF-A7 as components of your products. (1) Inverter should be installed in a panel. Pay attention to wiring openings, so that it should prevent someone from touching live parts through the opening in case of maintenance. 2) No more than 1 cable should be connected to one earth terminal of the main terminal board. In this case, other cables for ground should be grounded on the metal back plate and/or in the cubicle(refer to Fig. 5). Refer the size of grounding cable to Table. 4. (3) MCCB should be connected to the input side of the EMI filter. Inverter Grounding terminal Make other terminal for grounding Metal back plate Fig. 5-9 -

Compliance with UL Standard The VF-A7 models conform to the UL Standard have the UL/CUL mark on the nameplate. 2.1. Compliance with Installation The VF-A7 Inverter must be installed in a panel, and used within the maximum surrounding air temperature 50 degrees. For models for 15kW and smaller, they can be used at ambient temperature of up to 50 degrees by peeling off the label on the top of the inverter. Models for 18.5kW and larger can be used at ambient temperature of up to 50 degrees. (These models have no label on their top.) 2.2. Compliance with Connection Use the UL listed cables, 75 degree copper wire only, with the UL listed closed -loop terminal connector at field wiring connection to the inverter input terminals, R/L1, S/L2, T/L3, output terminals, U/T1, V/T2, W/T3, and other main terminals. Refer the wire gauge, the type of closed-loop terminals and crimping tools to Table.4 and Table.5. 2.3. Compliance with Peripheral devices Use the UL listed MCCB or fuses at connecting to power supply. (The fuses should be used CLASS CC/J.) Refer to the instruction manual about selecting the rating of them. Short circuit test is performed under the condition of the power supply short-circuit currents in Table. 3. These currents depend on the applicable motor capacities. Input voltage (v) 200 400 Table.3 Power supply short-circuit current and input voltage Applicable motor power supply shout-circuit current and maximum input voltage ( kw ) 0.4 ~ 37 Suitable for use on a circuit capable of delivering not more than 5,000 rms symmetrical amperes in below,240 volts maximum. 45 ~ 90 Suitable for use on a circuit capable of delivering not more than 10,000 rms symmetrical amperes in below,240 volts maximum. 0.4 ~ 37 Suitable for use on a circuit capable of delivering not more than 5,000 rms symmetrical amperes in below,480 volts maximum. 45 ~ 132 Suitable for use on a circuit capable of delivering not more than 10,000 rms symmetrical amperes in below,480 volts maximum. 160 ~ 280 Suitable for use on a circuit capable of delivering not more than 18,000 rms symmetrical amperes in below,480 volts maximum. - 10 -

Table.4 Wire gauge Wire gauge AWG (mm 2 ) Inverter type-form Input/output Control power Grounding terminal terminals supply terminals VFA7-2004PL 14 (2.1) 14 (2.1) 12 (3.3) VFA7-2007PL 14 (2.1) 14 (2.1) 12 (3.3) VFA7-2015PL 14 (2.1) 14 (2.1) 12 (3.3) VFA7-2022PL 14 (2.1) 14 (2.1) 12 (3.3) VFA7-2037PL 14 (2.1) 14 (2.1) 12 (3.3) VFA7-2055PL 12 (3.3) 14 (2.1) 12 (3.3) VFA7-2075PL 10 (5.3) 14 (2.1) 10 (5.3) VFA7-2110P 6 (13.3) 14 (2.1) 6 (13.3) VFA7-2150P 6 (13.3) 14 (2.1) 6 (13.3) VFA7-2185P 4 (21.2) 14 (2.1) 4 (21.2) VFA7-2220P 2 (33.6) 14 (2.1) 4 (21.2) VFA7-2300P 2/0(67.4) 14 (2.1) 2 (33.6) VFA7-2370P1 2/0(67.4) 14 (2.1) 2 (33.6) VFA7-2450P1 4/0 (107.2) 14 (2.1) 2/0(67.4) VFA7-2550P1 4/0 (107.2) 14 (2.1) 2/0(67.4) VFA7-2750P1 300 (152) 14 (2.1) 4/0 (107.2) VFA7-2900P1 300 (152) 14 (2.1) 4/0 (107.2) VFA7-4007PL 14 (2.1) 14 (2.1) 12 (3.3) VFA7-4015PL 14 (2.1) 14 (2.1) 12 (3.3) VFA7-4022PL 14 (2.1) 14 (2.1) 12 (3.3) VFA7-4037PL 14 (2.1) 14 (2.1) 12 (3.3) VFA7-4055PL 14 (2.1) 14 (2.1) 12 (3.3) VFA7-4075PL 14 (2.1) 14 (2.1) 12 (3.3) VFA7-4110PL 10 (5.3) 14 (2.1) 10 (5.3) VFA7-4150PL 10 (5.3) 14 (2.1) 10 (5.3) VFA7-4185P 8 (8.4) 14 (2.1) 8 (8.4) VFA7-4220P 6 (13.3) 14 (2.1) 6 (13.3) VFA7-4300P 6 (13.3) 14 (2.1) 6 (13.3) VFA7-4370P1 4 (21.2) 14 (2.1) 4 (21.2) VFA7-4450P1 2 (33.6) 14 (2.1) 4 (21.2) VFA7-4550P1 2 (33.6) 14 (2.1) 4 (21.2) VFA7-4750P1 2/0 (67.4) 14 (2.1) 2 (33.6) VFA7-4110KP1 4/0 (107.2) 14 (2.1) 2/0 (67.4) VFA7-4132KP1 4/0 (107.2) 14 (2.1) 2/0 (67.4) VFA7-4160KP1 300 (152) 14 (2.1) 4/0 (107.2) VFA7-4220KP1 400 (203) 14 (2.1) 4/0 (107.2) VFA7-4280KP1 300*2 (152*2) 14 (2.1) 300 (152) - 11 -

AWG (mm2) M3 Table. 5 Type-form of closed-loop terminals and crimping tools Type-form of closed-loop terminal M4 M5 M6 M8 M10 M12 14 (2.1) 2-3 R2-4 R2-5 ----- ----- ----- ----- 12 (3.3) ----- 3.5-4 3.5-5 ----- ----- ----- ----- R5.5- R5.5-10 (5.3) ----- ----- ----- ----- ----- 5 6 Hand tools YHT- 2210 8 (8.4) ----- ----- R8-5 R8-6 R8-8 ----- ----- YHT- 8S 6 (13.3) ----- ----- R14-5 R14-6 R14-8 R14-10 R14-12 ----- Crimping tools Airpressure Hydraulic tools tools YA-4 YA-4, YA-5 4 (21.2) ----- ----- ----- R22-6 R22-8 R22-10 R22-12 ----- YA-5 2 (33.6) ----- ----- ----- 38-6 R38-8 R38-10 R38-12 ----- 2/0 (67.4) ----- ----- ----- ----- 70-8 70-10 70-12 ----- ----- 4/0 R100- R100- ----- ----- ----- ----- ----- ----- ----- (107.2) 10 12 R150- R150-300 (152) ----- ----- ----- ----- ----- ----- ----- 10 12 400 (203) ----- ----- ----- ----- ----- ----- R200-12 ----- ----- (Note) The closed-loop terminal and crimping tools in Table. 5 are manufactured by JST Mfg. Co,. Ltd. BCT- 0514 YPT-150-1, BCT- 8150 (body) YF-1 (head) YET-150-1 (body) YF-1 (head) YET-300-1 2.4. Compliance with Motor overload protection The electronic thermal protection level and characteristic must be adjusted to fit the motor rated current and specification. Refer the detail of electronic thermal protection to the instruction manual. Installing external overload relay to each motor between inverter and motors when driving several motors simultaneously. - 12 -