product Digital combustion technology Weishaupt gas burners, WG10 to WG40 ( kw) Information on compact burners

Similar documents
product Digital dual fuel burners Weishaupt dual fuel burners WGL30-C and WGL40-A ( kw) Information on compact burners

product Digital combustion technology Weishaupt oil burners, WL10 to WL40 ( kw) Information on compact burners

Weishaupt WKGL70 dual fuel burner Version 3LN (Low NO x ) multiflam 1/2003 GB

Weishaupt gas burners Sizes 30 to 70 Version NR (NO x reduced)

info Increased capacity for industrial applications Weishaupt monarch gas burner WM-G10 version ZMI ( kw) Information on industrial burners

info The intelligent control concept W-FM 100 and W-FM 200 combustion managers Information on digital combustion management

product Compact and powerful Weishaupt monarch oil burner, WM-L20 ( kw) Information on oil burners

product Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable

product WM 20 for oil, gas and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on oil, gas and dual-fuel burners

info The intelligent control concept W-FM 100 and W-FM 200 combustion managers Product information on digital combustion management

product WM 30 for gas, oil, and dual-fuel WM 30 monarch burners ( kw) powerful and versatile Information on gas, oil, and dual-fuel burners

product WM 20 for gas, oil, and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on gas, oil, and dual-fuel burners

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 GB

Weishaupt Monarch oil burners Sizes 1 and 3 1/2002 GB

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

product WM 10 oil, gas and dual fuel version Weishaupt monarch WM10 burners flexible application Information on oil, gas and dual fuel burners

Weishaupt oil burners Sizes 30 to 70 1/2003 CA

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

info WK-series industrial burners Industrial burners WK40 to WK kw to 32,000 kw Information on Duoblock burners

GULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw.

info NO x emissions <15 ppm 4LN version gas burners (with Flue Gas Recirculation) Information on Ultra Low NO x gas burners

ONE STAGE GAS BURNERS RDBS SERIES

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

Oil, gas and dual fuel burners. Burner series

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.

RS/M SERIES. Modulating Gas Burners FIRING RATES

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 CA

product Oil burners, 1-11 monarch burners, sizes 1-11 ( kw) simply reliable Information on oil burners

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

RIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw

RIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS

Valve monitoring system VDK 200 A S02

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw

product WM 10 for gas, oil, and dual-fuel WM 10 monarch burners ( kw) versatile performance Information on gas, oil, and dual-fuel burners

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

Doing more for clean environment and energy saving

ONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw

Gas burner Dual fuel burner. Gas burner. Series RG GG MG. Dual fuel burner. Series MK

TECHNICAL DATA LEAFLET GAS. RS/1 Series. One Stage Gas Burners. RS 34/1 MZ kw RS 44/1 MZ kw.

ONE STAGE GAS BURNERS RS/1 SERIES RS 28/ kw RS 34/1 MZ kw RS 38/ kw RS 44/1 MZ kw

Oil, Gas and Dual Fuel Burners

DB Series. Technical Data Leaflet. Industrial Dual Block Oil, Gas and Dual Fuel Burners. Industrial TS0086UK00

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL

Light oil - kerosene burner

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw

RS Series Two Stage Progressive Gas Burners

Oil - kerosene burner

CODE MODEL TYPE PRESS GW 605 T80

The new generation of Brake Testers and Test Lanes: Safe and precise testing. For passenger cars and light commercial vehicles

Combination controls CG 10

TWO STAGE PROGRESSIVE GAS BURNERS

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

RIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

TWO STAGE LIGHT OIL BURNERS PRESS G SERIES

01 Overview 02 ecoo. 03 HybridChiller. 04 Re-cooler. 05 Circuit Separation. 06 Services. Contents 04/2018. Overview. 02 Cooling innovation

Our burner program for oil and gas Blue-flame oil burners Yellow-flame oil burners Gas burners. How to find us. Intercal Heat Technology simply good.

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

THE FASCINATION OF POWER & ROTATION

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

Steam output 0.3 to 3.0 t/h Operating Pressure 10 to 16 bar

MP-100-APS. Flame Spray Technologies SprayTech. Multi-Process Thermal Spray Centre

Monoblock burners for heating, commercial and light industry applications

Specifications of MAXON VALUPAK burners for 50 Hz operation

Tightness control TC. Product brochure GB Edition 12.10

Oil, Gas and Dual Fuel Monoblock Burners

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

RES G MRBLU SERIES. Low NOx One Stage Light Oil Burners FIRING RATES. LOW NOx LIGHT OIL

Old documentation - Only for your information! Product is not available any more!

Kerosene - oil burner

Skotch Trifecta Oil Valve System

Development test stands for E-motors

No one comes close to matching the 20:1 and 15:1 turndown of our condensing Benchmark boilers.

Solenoid actuator MB 7 and butterfly valves BVHM

Monoblock burners for heating, commercial and light industry applications

3 Edition Product brochure GB AGA

E Series CE Approved Intermittent Pilot Ignition Control

modular multi intelligent, environmental and versatile

PRODUCT RANGE A COMPLETE RANGE OF BURNERS FROM 17 TO kw

Trades Compressors. CLASSIC Series Flow rate 109 to 167 l/min Pressure 10 bar.

VE4000 & VE5000 SERIES

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Reservedeler for Weishaupt brenner WG20-C

COMPRESSOR SYSTEMS MADE IN GERMANY COMBI SCREW COMPRESSORS

Installation- and maintenance instruction ST120 S75/21

Heating and Gas Installations - December 2014

BSA 1409 D. Innovation boost for more efficiency and cost effectiveness

AMR. GB-Ganz Tüzeléstechnikai Kft. MODULATING DUOBLOCK BURNER FAMILY

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01

INFRA RADIATION EFFICIENCY UP TO 75%

power made simple kva RANGE Performance I Durability I Serviceability

INVEOR The new efficiency standard in pump technology The universal drive controller for all common motor types

GEMINI GAS CONTROL PRODUCT INFORMATION

AUTOFLAME Combustion Managment System

SpeedLine C100 C200. Production turning machines

NOBEL FIXED SPEED from 5.5 to 37 kw NOBEL DV VARIABLE SPEED from 7.5 to 37 kw

PRODUCT RANGE

DATA & FACTS Unit Heaters MultiMAXX HB. Quick Selection and Fast Delivery

A E R Z E N S C R E W C O M P R E S S O R S

Generator Set Range SG-3000 & SG-4000 Series

Transcription:

product Information on compact burners Digital combustion technology Weishaupt gas burners, WG1 to WG4 (12.5 55 kw)

Hot for quality Our motivation is technological progress, which has been driving us for more than 5 years to set new standards for the combustion industry. Weishaupt s own Research and Development Centre is constantly working on both new developments and the optimisation of exisitng products. It is our goal and our responsibility to go above and beyond current legislative requirements in developing combustion systems which produce fewer and fewer emissions, save more and more energy, and in so doing combine ecology and economy in a practical manner. Therefore, not only do we invest in research and technology but we also only ever work on the best materials with modern tools and we carry out meticulous quality control checks. It has been proven over a million times in the field that heating specialists and customers hold Weishaupt burners to be reliable, long lasting, environmentally friendly and technoloically advanced. A fact also documented by numerous design and innovation prizes. Over 6 burners are manufactured daily at our ultra-modern production facilities in Schwendi. Every single burner is subjected to a mechanical and electrical function test. The combination of technology with an effective quality control system safeguards Weishaupt s reknowned reputation for quality. A new burner is always an investment in the future. Cost needs to be well balanced against use, but the final deciding factors for long term sucess are quality, technology and safety. Deciding for Weishaupt burners is therefore a safe investment in the future. Ultra-modern research and production methods and rigourous quality control ensures the quality for which Weishaupt is reknowned 2

A hallmark of practical combustion technology Coded plugs for safe electrical connection All components are easily accessible Simple commissioning and diagnosis A safe investment in the future Reliable and economical: The miilionfold sucess of the Weishaupt compact burners is the result of orienting without compromise towards quality and the customer. The technology has been constantly developed and improved over decades. The latest production methods and stringent quality checks of all products ensure Weishaupt s reputation for quality. You are making a safe investment in the future. Large capacity range The large capacity range of 12.5 to 55 kw makes the burners suitable for the widest range of heat exchangers. Electronic ignition The W-ZG 1 ignition unit used on all Weishaupt W burners is particularly energy efficient and extremely reliable. Digital combustion management for safety and ease of use Weishaupt is a pioneer in this field. Digital combustion management offers greater ease of use and simple servicing, even greater relaibility in operation, and, last but not least, an extremely attractive price/capacity relationship. Furthermore, this intelligent technology enables the burner to be integrated with complex automation systems. Valve proving as standard with W-FM1 and W-FM2 combustion managers The low gas pressure switch is used to check the tightness of the gas valves, thus providing valve proving without the need for any additional components or costs. Gas multifunction assembly The newly concieved gas multifunction assembly incorporates the following components/functions: Servo-controlled gas pressure governor for continual gas pressure 2 solenoid valves (Class A) Filter Gas pressure switch If the gas pressure falls too low, a low gas pressure program is started. The gas pressure switch also provides for automatic valve proving. Outstanding service Weishaupt has an extensive sales and sevice network worldwide. Customer service is available around the clock. Optimal in-house training at Weishaupt ensures our service engineers are of the highest calibre. Proven quality All burners are tested by an independent body and conform to the following standards and EU directives: EN 676 Gas Appliance Directive 9/96/EEC Machinery Directive 98/7/EC Electromagnetic Compatability Directive 89/6/EEC Low Voltage Directive 7/2/EEC Boiler Efficiency Directive 92/42/EEC WG and WG4 also comform to: Pressure Equipment Directive 97/2/EC The right size Weishaupt burner for every situation 5

Digital combustion management: safe and easy to use All Weishaupt W series burners are fitted with digital combustion managers as standard, whose microprocessors control and monitor all burner functions. The result: Weishaupt burners are easy to use, precise and safe. The digital combustion managers also offer the possibility of communicating with other systems via an integrated ebus port. This enables the heating engineer to monitor the opration of the burner and remotely diagnose any errors. The key points: The utilisation of identical units for gas and oil burners simplifies commissioning and reduces the number of spares required. Non-interchangeable plug connections ensure the correct electrical connection of all components Electrical remote reset is possible Safety ensured with the use of two microprocessors (reciprocal monitoring) Vari-coloured LED lamp to indicate burner operational stage and fault conditions (WG1, WG2 versions LN and Z-LN) LCD display with interrogation, servicing and parameter functions. the burner can be set directly via the operating keys (WG1 WG4 version ZM-LN) Suitable for continuous operation of hot water plant (controlled shutdown and restart every 24 hours) Suitable for air heaters and Group II III, and IV steam boilers (W-FM 21 optional) The integrated ebus interface offers the following functions: Connection to a PC for display of the operational sequence and the setting of function parameters Remote monitoring and diagnosis via a self dialling modem Connection to modern building management systems Prepurge time can be set from a PC via the ebus interface System overview Digital combustion management W-FM 5 W-FM 1 W-FM 2 W-FM 21 Combustion manager for intermittent operation Combustion manager for continuous operation Flame sensor Ion Ion Ion Ion Electronic compound regulation Air and gas Stepping motor Air Removable control unit (max. distance) 1 m 1 m Valve proving Fuel consumption meter available ebus interface Available on burner models WG 1-D WG 1-D WG 1 WG 4 WG 1 WG 4 WG 2-C WG 2-C modulating modulating single stage single stage WG WG 4 WG WG 4 without servomotor with servomotor with speed control with speed control and two stage TRD execution 6

The right mode of operation for every heating need Gas burners Single and two stage With mechanical compound regulation and integral gas valve proving Gas butterfly valve Gas multifunction assembly W-FM 1 combustion manager Air stepping motor (with linkage to gas butterfly valve) Gas burners Sliding two stage / modulating With electronic compound regulation and integral gas valve proving Gas stepping motor Gas multifunction assembly W-FM 2 combustion manager Air stepping motor Mode of operation F = Full load P = Partial load I = Ignition load Single stage without servomotor GF ZI Sliding two stage GF KP ZI On Off On Off Two stage with servomotor Modulating GF GF KP ZI KP ZI On Off On Off 7

Trustworthy technology Even the visual impression after removing the burner cover is convincing. All components are clearly arranged, the electrical connections are obvious and non-interchangeable. The technology makes a good impression because it is typical Weishaupt. Compact construction The WG burners compact construction means they can be easily installed by one person. Commissioning costs have been reduced to a minimum. Low NO x execution All WG burners are Low NO x execution as standard. A specially designed mixing head produces an intensive internal flue gas recirculation, resulting in exemplary emission levels. Sound attenuated air inlet The transverse fan is sound attenuated on the suction side. These burners therefore operate particularly quietly. Electronically controlled air damper The electronically controlled air damper closes at burner shutdown to hinder the cooling-down of the combustion chamber. Sevicing position A special bracket enables the burner to be put into a servicing position, which enabling easy access to the burner and mixing assembly. Common platform The common platform principle used with W burners simplifies the provision and storage of spare parts. Diagnosis via laptop A special software package and connection cables are available for interrogating the combustion manager. Combustion optimisation and fault analysis can thus be carried out easily via a laptop computer. Speed control (WG and WG 4) Whereas normally a burner motor is operated at a constant speed, speed controlled burners vary the speed of the burner motor dependent on the burner load. The process is controlled by the digital combustion manager. The equipment assures the gas/air compound such that no additional speed monitoring is required. Speed controls offers the advantages of reduced electrical consumption and a considerable reduction in noise levels at partial load. The reduced noise levels can be of particular benefit in the field. A 1 db reduction in the sound level can be achieved at 5% burner load, which equates to a halving of noise emissions. 8

W-FM 2 combustion manager Variable speed motor Fan pressure impulse line Combustion chamber pressure impulse line Double solenoid valve with ratio controller Digital-analogue convertor Frequency convertor Example: WG4 with speed control 9

Model overview Burner type Version Mode of operation Valve train Product Order BSP / DN kw Ident-Number No. WG 1 Natural gas WG 1 N/-D ZM-LN sliding two stage or modulating 1/2 12,5 5 CE-85 AU 5 22 16 14 WG 1 N/1-D LN single stage with manually set air damper /4 4 11 CE-85 BM 481 22 11 24 WG 1 N/1-D Z-LN single or two stage /4 25 11 CE-85 BM 481 22 12 24 WG 1 N/1-D ZM-LN sliding two stage or modulating /4 25 11 CE-85 BM 481 22 126 24 LPG WG 1 F/-D ZM-LN sliding two stage or modulating 1/2 12,5 5 CE-85 AU 5 2 16 14 WG 1 F/1-D LN single stage with manually set air damper /4 4 11 CE-85 BM 481 2 11 24 WG 1 F/1-D Z-LN single or two stage /4 25 11 CE-85 BM 481 2 11 24 WG 1 F/1-D ZM-LN sliding two stage or modulating /4 25 11 CE-85 BM 481 2 126 24 WG 2 Natural Gas WG 2 N/1-C LN single stage with manually set air damper 1 1 8 2 CE-85 BM 216 22 21 4 WG 2 N/1-C Z-LN single or two stage 1 1 5 2 CE-85 BM 216 22 21 4 WG 2 N/1-C ZM-LN sliding two stage or modulating 1 1 5 2 CE-85 BM 216 22 216 4 WG 2 N/1-C LN single stage with manually set air damper 1 2 8 2 CE-85 BM 216 22 21 44 WG 2 N/1-C Z-LN single or two stage 1 2 5 2 CE-85 BM 216 22 21 44 WG 2 N/1-C ZM-LN sliding two stage or modulating 1 2 5 2 CE-85 BM 216 22 216 44 LPG WG 2 F/1-C LN single stage with manually set air damper /4 1 8 2 CE-85 BM 216 2 21 24 WG 2 F/1-C Z-LN single or two stage /4 1 5 2 CE-85 BM 216 2 21 24 WG 2 F/1-C ZM-LN sliding two stage or modulating /4 1 5 2 CE-85 BM 216 2 216 24 WG WG N/1-C ZM-LN sliding two stage or modulating /4 4 5 CE-85-AU 64 22 26 21 1 22 26 1 1 1/2 22 26 51 WG F/1-C ZM-LN sliding two stage or modulating /4 6 5 CE-85-AU 64 2 26 21 WG 4 WG 4N/1-A ZM-LN sliding two stage or modulating /4 55 55 CE-85-AS 11 22 416 21 1 22 426 1 1 1/2 22 416 51 2 22 46 61 DN65 22 416 1 DN8 22 416 41 WG 4F/1-A ZM-LN sliding two stage or modulating /4 8 55 CE-85-AS 11 2 416 21 1 with gas multifunction assembly type 57 2 with gas multifunction assembly type 512 for supply pressure p a 5 mbar only (p a > 5 mbar to mbar at extra cost) Note: Valve trains are supplied without thermal shut offs. See Weishaupt accessories list for thermal shut off prices, Print No. 82121. See price list for special equipment 1

Burner capacities in relation to combustion chamber resistance Capacity graph WG 1 mbar Burner type WG 1.../-D Vers. ZM-LN Combustion head WG 1/-D 12.5 5 kw 1,5 1.5 1, 1.,5.5 -,5 -.5 kw 1 2 4 5 6 Capacity graph WG 1 mbar Burner type,. 2,5 2.5 2, 2. 1,5 1.5 1, 1.,5.5 -.5 -,5-1, -1. kw WG 1.../1-D Vers. LN Combustion head WG 1-D 4 11 kw 2 4 6 8 1 12 Capacity graph WG 1 mbar Burner type,. 2,5 2.5 2, 2. 1,5 1.5 1, 1.,5.5 -.5 -,5-1, -1. kw WG 1.../1-D Vers. Z-LN / ZM-LN Combustion head WG 1-D 25 11 kw 2 4 6 8 1 12 Capacity graph WG 2 mbar Burner type,. 2,5 2.5 2, 2. 1,5 1.5 1, 1.,5.5 -.5 -,5-1, -1. kw 2,5.5,. 2,5 2.5 2, 2. 1,5 1.5 1, 1.,5.5 -.5 -,5-1, -1. -1,5-1.5 kw 6 WG 2.../1-C Vers. LN Combustion head WG 2-C 8 2 kw Capacity graph WG mbar Burner type 1 14 18 WG F/1-C Vers. ZM-LN Combustion head WG 6 5 kw 1 2 4 Capacity graph WG 2 mbar Burner type,. 2,5 2.5 2, 2. 1,5 1.5 1, 1.,5.5 -.5 -,5-1, -1. kw 2 8 7 6 5 4 2 1-1 -2 kw 6 WG 2.../1-C Vers. Z-LN / ZM-LN Combustion head WG 2-C 5 2 kw Capacity graph WG 4 mbar Burner type 1 14 18 Do not select firing rate below 8 kw. WG 4N/1-A Vers. ZM-LN Combustion head WG 4 55 55 kw 1 2 4 5 Capacity graph WG mbar Burner type,5.5,. 2,5 2.5 2, 2. 1,5 1.5 1, 1.,5.5 -.5 -,5-1. -1, -1,5-1.5 kw 8 7 6 5 4 2 1-1 -2 kw WG N/1-C Vers. ZM-LN Combustion head WG 4 5 kw 1 2 4 Capacity graph WG 4 mbar Burner type WG 4F/1-A, Vers. ZM-LN Combustion head WG 4 8 55 kw 1 2 4 5 Mixing head open Mixing head closed Capacity graphs in accordance with EN 676. The ratings are based on an installation altitude of m. An altitudebased reduction in capacity of approx. 1 % per 1 m above sea level should be taken into consideration. Speed control is available for natural gas burners only. The minimum rating is limited to 6 kw for WG and 8 kw for WG 4 burners. 11

Valve train selection WG 1.../-D with W-MF 55 p e max p e max 5 mbar > 5, mbar [kw] 1/2 1/2 Nat. gas E, H i = 7.26 MJ/m n (1.5 kwh/m n ), d =.66, Wi = 47.84 kwh/m n 25 15 18 15 18 5 16 19 4 16 19 45 17 2 5 18 21 p e max p e max 5 mbar > 5, mbar [kw] 1/2 1/2 Nat. gas LL, H i = 1.79 MJ/m n (8.8 kwh/m n ), d =.641, W i = 9.67 kwh/m n 25 15 18 16 19 5 17 2 4 18 21 45 19 22 5 2 2 p e max p e max 5 mbar > 5, mbar [kw] 1/2 1/2 LPG B/P, H i = 9.2 MJ/m n (25.89 kwh/m n ), d = 1.555, W i = 74.7 kwh/m n 25 1 16 1 16 5 1 16 4 14 17 45 14 17 5 15 18 WG 1.../1-D with W-MF 57 SE /SLE p e max = mbar [kw] /4 Nat. gas E, H i = 7.26 MJ/m n (1.5 kwh/m n ), d =.66, Wi = 47.84 kwh/m n 4 1 5 1 6 1 7 1 8 1 9 11 1 12 11 1 p e max = mbar [kw] /4 Nat. gas LL, H i = 1.79 MJ/m n (8.8 kwh/m n ), d =.641, W i = 9.67 kwh/m n 4 12 5 12 6 12 7 12 8 1 9 14 1 15 11 16 p e max = mbar [kw] /4 LPG B/P, H i = 9.2 MJ/m n (25.89 kwh/m n ), d = 1.555, W i = 74.7 kwh/m n 4 8 5 8 6 9 7 9 8 1 9 11 1 12 11 12 WG 2.../1-C with W-MF 5xx SE / SLE p e max = mbar [kw] 1 1 1 2 Nat. gas E, H i = 7.26 MJ/m n (1.5 kwh/m n ), d =.66, Wi = 47.84 kwh/m n 8 1 11 9 1 11 1 1 11 11 14 12 12 14 1 1 15 1 14 15 1 15 16 14 16 16 15 17 16 15 18 16 15 19 17 16 2 18 16 p e max = mbar [kw] 1 1 1 2 Nat. gas LL, H i = 1.79 MJ/m n (8.8 kwh/m n ), d =.641, W i = 9.67 kwh/m n 8 15 1 9 15 1 1 15 14 11 16 14 12 16 15 1 17 16 14 18 16 15 18 17 16 19 17 17 2 18 18 21 18 19 22 19 2 2 2 p e max = mbar [kw] /4 LPG B/P, H i = 9.2 MJ/m n (25.89 kwh/m n ), d = 1.555, W i = 74.7 kwh/m n 8 1 9 1 1 1 11 14 12 14 1 14 14 14 15 15 16 15 17 16 18 17 19 18 2 19 1 with gas multifunction assembly type 57 2 with gas multifunction assembly type 512 additional FRS governor required when p a > 5 mbar (to max mbar) 12

WG.../1-C, LN version with W-MF 5xx SE valve) p e max = mbar [kw] /4 1 11/2 Nat. gas E, H i = 7.26 MJ/m n (1.5 kwh/m n ), d =.66, Wi = 47.84 kwh/m n 1 15 14 1 16 17 15 14 19 18 15 1 21 19 15 1 24 21 15 1 27 2 16 1 26 17 14 5 2 16 valve) p e max = mbar [kw] /4 1 11/2 Nat. gas LL, H i = 1.79 MJ/m n (8.8 kwh/m n ), d =.641, W i = 9.67 kwh/m n 1 18 15 14 16 2 16 15 19 22 17 15 21 2 17 15 24 26 18 15 27 19 15 4 21 17 5 44 26 21 valve) p e max = mbar [kw] /4 LPG B/P, H i = 9.2 MJ/m n (25.89 kwh/m n ), d = 1.555, W i = 74.7 kwh/m n 1 1 16 14 19 14 21 15 24 15 27 17 18 5 21 WG 4.../1-A, LN version with W-MF 5xx SE or DMV + FRS valve) p e max = mbar [kw] /4 1 11/2 2 65 8 Nat. gas E, H i = 7.26 MJ/m n (1.5 kwh/m n ), d =.66, Wi = 47.84 kwh/m n 24 19 14 12 11 11 11 27 22 14 12 12 11 11 25 15 1 12 11 11 5 17 1 1 12 11 4 6 19 14 1 12 11 45 42 22 15 14 12 12 5 52 27 18 17 15 14 55 61 1 21 19 16 15 valve) p e max = mbar [kw] /4 1 11/2 2 Nat. gas E, H i = 7.26 MJ/m n (1.5 kwh/m n ), d =.66, Wi = 47.84 kwh/m n 1 18 6 6 5 16 21 9 8 7 19 25 12 1 1 22 29 15 1 12 25 2 18 15 14 28 7 24 16 14 1 4 28 17 16 5 51 19 18 valve) p e max = mbar [kw] /4 1 11/2 2 65 8 Nat. gas LL, H i = 1.79 MJ/m n (8.8 kwh/m n ), d =.641, W i = 9.67 kwh/m n 24 26 17 15 14 1 1 27 29 18 15 14 1 1 19 15 14 1 1 5 4 22 16 15 1 1 4 49 26 18 17 15 14 45 6 21 19 16 15 5 72 5 2 21 18 17 55 86 42 27 25 21 19 WG.../1-C with DMV VEF (speed controlled burner valve) p e max = mbar [kw] /4 1 11/2 2 Nat. gas E, H i = 7.26 MJ/m n (1.5 kwh/m n ), d =.66, Wi = 47.84 kwh/m n 24 11 1 9 4 14 1 11 6 54 18 15 1 4 64 2 17 15 44 75 2 2 16 48 88 26 24 18 52 11 29 28 2 55 111 1 22 valve) p e max = mbar [kw] /4 1 11/2 2 Nat. gas LL, H i = 1.79 MJ/m n (8.8 kwh/m n ), d =.641, W i = 9.67 kwh/m n 1 2 8 7 6 16 28 11 9 9 19 4 14 12 11 22 4 17 15 14 25 46 2 17 16 28 52 26 19 17 1 61 2 2 19 5 7 4 2 21 WG 4.../1-A with DMV VEF (speed controlled burner) valve) p e max = mbar [kw] /4 1 11/2 2 Nat. gas LL, H i = 1.79 MJ/m n (8.8 kwh/m n ), d =.641, W i = 9.67 kwh/m n 24 42 1 11 1 57 18 15 1 6 74 22 19 16 4 92 25 22 18 44 19 29 24 2 48 126 4 28 22 52 144 6 4 25 55 157 8 7 27 valve) p e max = mbar [kw] /4 LPG B/P, H i = 9.2 MJ/m n (25.89 kwh/m n ), d = 1.555, W i = 74.7 kwh/m n 24 1 27 14 16 5 19 4 22 45 26 5 29 55 Clarification of designation W G 2 N.../1-C LN F LN = Low NO x Index N = Natural gas E and LL F = LPG B/P Size G = Gas burner Weishaupt W Series burner Notes: 1/2 to 2 valve trains have screwed connections, DN65 and DN8 have flanged connections. The valve trains can be equipped with thermal shut offs at extra cost. The flue gas resistance must be added to the minimum supply pressure calculated. The minimum supply pressure should be no less than 15 mbar. 1

Technical data Rp d1 h h1 h2 b1 I2 I1 I d d4 b2 b α d2 I4 Burner dimensions Burner type Dimensions in mm I1 I2 I I4 b1 b2 b h1 h2 h d1 d2 d d4 Rp α WG 1 14 49 1,5 115 165 164 5 27 165 18 M8 15 17 11 /4 45 WG 2 14 97 2 158 58 182 178 76 284,5 182 12 M8 17 1 1 45 WG 166 48 62 197 42 226 196 46 42 226 127 M8 17 186 1 1 1 /2 45 WG 4 25 577 72 25 45 245 27 48 6 245 154 M1 186 2 16 1 1 /2 45 14

Technical data Burner type Combust. Motor Servomotor Air pressure Burner Gas valve train Flame manager switch weight 1 Size Type Weight 1 monitoring WG 1.../-D Vers. ZM-LN W-FM 2 ECK 2/F 2/1 STE 4.5 * LGW /A1 1.5 kg 1/2 W-MF 55 6 kg Ionisation 2 V, 5 Hz.4 kw, Cap. 2 µf WG 1.../1-D Vers. LN W-FM 5 ECK /F 2/1 none LGW 1/A2 1.5 kg /4 W-MF SLE 57 6 kg Ionisation Vers. Z-LN W-FM 1 2 V, 5 Hz STD 4.5 ** /4 W-MF SE 57 Vers. ZM-LN W-FM 2.95 kw, Cap. 4 µf STE 4.5 * /4 W-MF SE 57 WG 2.../1-C Vers. LN W-FM 5 ECK 4/F 2/1 none LGW 1/A2 2 kg 1 W-MF SLE 57/512 6 kg / 7 kg Ionisation Vers. Z-LN W-FM 1 2 V, 5 Hz STD 4.5 ** 1 W-MF SE 57/512 Vers. ZM-LN W-FM 2.21kW, Cap. 8 µf STE 4.5 * 1 W-MF SE 57/512 WG.../1-C Vers. ZM-LN W-FM 2 ECK 5/F-2 STE 4.5 * LGW 1A2 27 kg /4 W-MF SE 57 5.5 kg Ionisation 2 V; 5 Hz BO.6/6-1L 1 W-MF SE 512 9. kg 29 rpm 11/2 W-MF SE 512 1.5 kg.42 kw; Cap. 12 µf Vers. ZM-LN W-FM 2 DK 5/F-2 STE 4.5 * LGW 1A2 kg /4 DMV-VEF 57 6.5 kg Ionisation with speed ~; 2 V; 5 Hz BO.6/6-1L 1 DMV-VEF 512 1. kg control 288 rpm 11/2 DMV-VEF 512 12. kg.42 kw; 2.6 A 2 DMV-VEF 52 15. kg WG 4.../1-A Vers. ZM-LN W-FM 2 ECK 6/F-2 STE 4.5 * LGW1A2 5 kg /4 W-MF SE 57 5.5 kg Ionisation 2 V; 5 Hz BO.6/6-1L 1 W-MF SE 512 9. kg 29 rpm 11/2 W-MF SE 512 1.5 kg.62 kw; 2 DMV+FRS 52 17.5 kg Cap. 16 µf 65 DMV+FRS 565 5. kg 8 DMV+FRS 58 67. kg Ausf. ZM-LN W-FM 2 DK 6/F-2 STE 4.5 * LGW1A2 8 kg 1 DMV-VEF 512 1. kg Ionisation with speed ~; 2 V; 5 Hz BO.6/6-1L 11/2 DMV-VEF 512 12. kg control 29 rpm 2 DMV-VEF 52 15. kg.62 kw; 4 A * Runtime during operation: with full setting movement max. 5 s/with reduced setting movement min. 25 s/runtime during pre-purge approx.1 2 s. ** Runtime during operation: with full setting movement approx. s/with reduced setting movement < s/runtime during pre-purge approx. s. 1 All weights are approximate. 15

Max Weishaupt GmbH D-88475 Schwendi Tel (7 5) 8, Fax (7 5) 8 58 www.weishaupt.de Print No. 82552, April 26 Printed in Germany. All rights reserved. Neachells Lane, Willenhall, WV1 RG Tel (192) 69841, Fax (192) 64 We re right where you need us 6 Carlton Place, Glasgow, G5 9TW Tel (141) 42 2, Fax (141) 42 288 A strong sevice network gives peace of mind Weishaupt equipment is available from good heating companies, with whom Weishaupt works in partnership. To support the specialists, Weishaupt meintains a large sales and service network. Delivery, spares and service are thus contiunally ensured. Even in an emergency, Weishaupt is on the job. The service department is available to Weishaupt customers around the clock, 65 days a year. A Weishaupt branch office or agency near you can answer all your questions on heating and Weishaupt burners and heating systems.