Ventilation Blowers 09. Introduction Heavy Duty Radial Blowers Radial Blowers In-Line Blowers

Similar documents
Fully Automatic Bilge Pump INSTRUCTION MANUAL

08 general Purpose Pumps

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

ICOMIA Global Conformity Guideline for ISO and ABYC Standards. Guideline Number 8 Ventilation of fuel systems

07 Oil Change & Diesel Transfer Pumps

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

07 Oil Change & Diesel Transfer Pumps

ICOMIA Global Conformity Guideline for ISO and ABYC Standards. Guideline Number 1 Installed Fuel Systems and Fixed Fuel Tanks

SERVICE & INSTALLATION

Electric Furnace KF/KFS Series

50830 Series Low Pressure Centrifugal Pump

02 Bilge Pumping Systems

Whale - Electric Bilge Pump Range From the Experts in Bilge Pumps experience in electronics

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

General Purpose Pumps - Introduction

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM)

MODEL FF50 CEILING FAN

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

National Marine Manufacturers Association Product Compliance Specialist Examination D.C. Electrical (2013 MY) ABYC E-11 (08 Amended 09)

Owner s Manual. PowerVerterDC-to-AC Inverter

Terminal/Alternator Auxiliary Terminal to Light to Regulator Fuse or Switch to Pumps

forward curved inline duct blowers

Marine Trade Catalogue SERVICING OVER 10 MILLION BOATS WORLDWIDE

SSK.1.3 Sound level shall not exceed 86 db(a) at 22.86m (75 ft.). See Section 19.5 (pg. 78).

CEILING & INLINE/CABINET VENTILATORS

Flexshield Marine Barrier Hose USCG/SAE J1527 & ISO 7840 Type A Yes Yes. Marine Fuel Feed Vent Hose USCG/SAE J1527 Type A2 98 Yes Yes

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

High Performance Fan Coils FCHG Genesis Series Horizontal

ceiling & inline/cabinet ventilators

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

WELDING FUME EXHAUSTERS & ARMS

* Not illustrated in exploded view.

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

Work area: Max. pressure: 2,150Pa Max. air volume: 2.100m³/h. Manufacturer. Production year. Model number/type. page

TURBO PRESSURE BLOWERS

MARINE PRODUCTS CATALOG

R4GA Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. R4GA 10 SEER 2 Ton thru 5 Ton Units FEATURES AND BENEFITS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

FOX TrimAway INSTALLATION AND OPERATING INSTRUCTIONS FAMILIARIZE YOURSELF WITH THE SYSTEM COMPONENTS

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

Purifier Logic Class II Biosafety Cabinets FEATURES & BENEFITS

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

ALTERNATE COMPLIANCE PROGRAM

Battery Chargers - Phase Three Series

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

SINGLE DUCT TERMINAL UNITS

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

abc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.

AIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features

DF6SF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

IN-LINE CENTRIFUGAL DUCT FANS VT Series

Twin City Fan & Blower

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT

Light-duty 6-Series Alternators are engineered to replace most OEM alternators on a wide variety of marine gasoline and diesel engines.

PA55 10 SEER FEATURES 2 THRU 5 TON SINGLE PACKAGE AIR CONDITIONER

Xenon Fiberoptic Lightsource

Tubular Centrifugal Fans

1) Only gasoline exhaust systems shall be gas-tight to the hull interior

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

Explosion Proof Electric Fan/Blower - C1D1-1/3 HP Engine - Fan Only- 50' SOOW w/ EPP Cord Cap

Direct Gas-Fired Heating

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD FAIRLANE & CROWN VICTORIA

AUTOMOTIVE POWER INVERTERS INSTRUCTIONS. Item #31463, #31464, #31465

APPENDIX A. 15 DUAL WELD STATION FUME EXTRACTION with 30 WELDING BOOTHS

CONSTRUCTION FEATURES AND OPTIONS

Marine Propulsion 3126

CAV controllers Type RN

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

6L Oil-less Air Compressor 53103

ROOFMASTER STEF-HT ROOF FAN

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower

MAIN PRODUCTS IN TMC:

13 SEER Light Commercial 3 Phase

GR4GD Series. Single Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS. GR4GD 13 SEER 2 Ton thru 5 Ton Units FEATURES AND BENEFITS

HIGH TEMPERATURE TWIN SQUIF FANS

MCE4 MCE4. Electric Heating / Electric Cooling Packaged Thru-the-Wall Units

Uniclass L7534. Manufacture controlled to ISO9001

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

ELECTRIC HEAT AIR HANDLERS

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200

HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION. Exflow 28 Technical Specification. Page 1 of 7

part three electrical installations

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

Toilet Systems - Introduction

Transcription:

Ventilation Blowers 09 Introduction Heavy Duty Radial Blowers Radial Blowers In-Line Blowers 123

124 09 Ventilation Blowers Product selection Heavy Duty Radial Blowers Heavy Duty Model Details Ducting Volume Voltage 35760-0092 35760-0094 15 amp. 10 amp. 9½ l x 8¾ x 9 (24cm x 22cm x 23cm) 6lb (2.7kg) DC 8lb (3.6kg) AC 36760-0115* 115 volt AC 60Hz flangemount, fuse 2 amp. 115V Heavy Duty Flexmount Blowers Model Details Ducting Volume Voltage 35760-0092 35760-0094 15 amp. 10 amp. 9½ x 8¾ x 9 (24cm x 22cm x 23cm) 6lb (2.7kg) DC 8lb (3.6kg) AC 36760-0115* 115 volt AC 60Hz flangemount, fuse 2 amp. 115V Radial Blowers Model Details Ducting Volume Voltage Output 35115-0020 34739-0010 34739-0020 35400-0000 35400-0010 12 volt DC flangemount, fuse 6 amp. 12 volt DC flangemount, fuse 10 amp. 24 volt DC flangemount, fuse 5 amp. 12 volt DC flangemount, fuse 15 amp. 24 volt DC flangemount, fuse 7.5 amp. 0-2m 3 (0-75ft 3 ) 6¾ x 4¾ x 5½ (17cm x 12cm x 14cm) 8 x 6¾ x 7¾ (20cm x 17cm x 20cm) 8 x 6¾ x 7¾ (20cm x 17cm x 20cm) 8¾ x 8¾ x 9 (22cm x 22cm x 23cm) 8¾ x 8¾ x 9 (22cm x 22cm x 23cm) 4lb (1.8kg) 5lb (2.3kg) 5lb (2.3kg) 6lb (2.7kg) 6lb (2.7kg) (3m 3 /min) output Flexmount Blowers Model Details Ducting Volume In-Line Blowers 35515-0010 36740-0031 36740-0000 36740-0010 35440-0000 35440-0010 fuse 6 amp. 115 volt AC flexmount, fuse 1.25 amp. fuse 10 amp. fuse 5 amp. fuse 15 amp. fuse 7.5 amp. 0-2m 3 (0-75ft 3 ) 0-2m 3 (0-75ft 3 ) 6 ¾ x 5 x 5 ½ (17cm x 13cm x 14cm) 8¼ x 7¾ x 9 (21cm x 20cm x 23cm) 8 x 8¼ x 9 (20cm x 21cm x 23cm) 8 x 8¼ x 9 (20cm x 21cm x 23cm) 3½lb (1.6kg) 5lb (2.3 kg) 5½lb (2.5kg) 5½lb (2.5kg) 9¹/8 x 9 3 /16 x 9 5 /8 7lb (23.2cm x 23.4cm x 24.5cm) (3.2kg) 9¹/8 x 9 3 /16 x 9 5 /8 7lb (23.2cm x 23.4cm x 24.5cm) (3.2kg) Voltage Output 115V (3m 3 /min) output For 140cfm (4m 3 /min) output In-line Blowers Model Details Ducting Volume Voltage Output 140 13.6 volt, fuse 4 amp. 0-75ft³ (0-2m³) 1.2lb (0.55kg) 12v 0-75ft 3 (0-2m 3 ) 140-24v 27.2 volt, fuse 2.5 amp. 0-75ft³ (0-2m³) 1.2lb (0.55kg) 24v 0-75ft 3 (0-2m 3 ) 140 13.6 volt, fuse 4 amp. 75-90ft³ (2.5-5m) 1.2lb (0.55kg) 12v 75-90ft 3 ( ) 240-24v 27.2 volt, fuse 2.5 amp. 90-220ft³ (2.5-5m³) 1.28lb (0.58kg) 24v 75-90ft 3 ( ) 240 13.6 volt, fuse 4 amp. 90-220ft³ (2.5-5m³) 6 x 4 x 43/16 1.28lb (15.2cm x 10.2cm x 10.6cm) (0.58kg) 12v 90-220ft 3 (5-67m 3 ) 240-24v 27.2 volt, fuse 2.5 amp. 90-220ft³ (2.5-5m³) 6 x 4 x 43/16 1.28lb (15.2cm x 10.2cm x 10.6cm) (0.58kg) 12v 90-220ft 3 (5-67m 3 ) This guide is based on International Standard ISO 11105 for small craft ventilation of gasoline engine and/or gas tank compartments which specifies minimum airflow for given engine compartment.

125 Product Selection Ventilation Blowers 09

126 09 Ventilation Blowers Introduction Jabsco DC blowers are designed to remove fumes from the engine compartments of gasoline powered boats prior to start-up and therefore conform to ISO 8846 MARINE and USCG Regulations for ignition protection. They are listed as N.M.M.A. type accepted and comply with ISO 9097 MARINE and are CE marked. AC models are not ignition protected. Jabsco blowers can also be used for air intake or extraction in galleys, bilges, accommodation and head compartments. Only the heavy duty blowers are designed for continuous duty operation in commercial or heavy use applications. Blowers should not be installed close to sources of direct heat exceeding 180 F (55 C). are of a radial design which gives the highest output in more complex installations with longer lengths and/or multiple bends in the. They are generally mounted directly onto a flat bulkhead using a mounting collar to connect to the discharge. This allows a very neat installation on an engine room bulk head. Flexmount Blowers Flexmount Blowers are also of radial design but are installed by attaching a mounting collar around the motor (which is supplied with the blower) to any convenient solid surface. They can be rotated inside the collar to allow the shortest lengths and most convenient routings in confined spaces. Both ports are designed for slip-on flexible connections.

127 Flexmount Blowers Heavy Duty Heavy Duty Blowers are designed for applications such as commercial or high use engine room ventilation and extraction where a long life requirement demands heavy duty motors with long brush life. Built to provide the same high outputs as our standard specification blowers. 5,000 hr motor life for the heaviest of applications. Continuous duty. Efficient high volume air flow. Outlet flange mounts directly on bulkhead. Slip on inlet connection. Corrosion resistant materials throughout. Dimensionally stable quiet running Delrin rotors. Complies with USCG 183.410 and ISO 8846 MARINE (Ignition Protection) - DC only. ISO 9097 MARINE (Electric Fans). Heavy Duty Flexmount Blowers Heavy Duty Flexmount Blowers Flexmount Blowers are built to the same high specification as the Heavy Duty for use as air intake or extraction systems in engine rooms, fuel compartments, galleys or heads. 5,000 hr motor life for the heaviest of applications. Continuous duty. Efficient high volume air flow. Flex mounting for 360 adjustable outlet. Slip on inlet connections. Corrosion resistant materials throughout. Dimensionally stable quiet running Delrin rotors. Complies with USCG 183.410 and ISO 8846 MARINE (Ignition Protection) - DC only. ISO 9097 MARINE (Electric Fans)... 9½ long x 8¾ wide x 9 high (24cm x 22cm x 23cm). 9 long x 9½ wide x 9¾ high (23cm x 24cm x 25cm). 6lb (2.7kg) DC. 8lb (3.6kg) AC. 7lb (3.2kg) DC. 9lb (4.1kg) AC. (7.1m3/min) output 12, 24, 115V. (7.1m3/min) output - 12, 24, 115V. *Not available in Europe. 35760-0092 15 amp. 35760-0094 10 amp. 36760-0115* 115 volt AC 60Hz flangemount, fuse 2 amp. *Not available in Europe. 35770-0092 fuse 15 amp. 35770-0094 fuse 10 amp. 36770-0115* 115 volt AC 60Hz flexmount, fuse 2 amp. Heavy Duty Radial Blowers Ventilation Blowers 09

128 09 Ventilation Blowers Radial Blowers Sizing Definitions Flexmount Flangemount Range of high volume air intake or extraction blowers for engine room, fuel compartment, galley or heads. Outlet flange mounts directly on bulkhead. Slip-on inlet connection. Dimensionally stable quiet running Delrin rotors. Corrosion resistant materials throughout. Complies with USCG 183.410 and ISO 8846 MARINE (Ignition Protection). ISO 9097 MARINE (Electric Fans).. 6¾ long x 4¾ wide x 5½ high (17cm x 12cm x 14cm). 4lb (1.8kg). (3m3/min) output.. 8 long x 6¾ wide x 7¾ high (20cm x 17cm x 20cm). 5lb (2.3kg). (4.2m3/min) output. 34739-0010 10 amp.. 8¾ long x 8¾ wide x 9 high (22cm x 22cm x 23cm). 6lb (2.7kg). (7.1m3/min) output. 34739-0020 5 amp. 35115-0020 6 amp. 35400-0000 15 amp. 35400-0010 7.5 amp.

129 Flexmount Blowers Range of high volume air intake or extraction blowers for engine room, fuel compartment, galley or heads. Flexmounting for 360 adjustable outlet. Slip-on inlet and outlet connections. Dimensionally stable, quiet running Delrin rotors. Corrosion resistant materials throughout. Complies with USCG 183.410 and ISO 8846 MARINE (Ignition Protection). ISO 9097 MARINE (Electric Fans). For 140cfm. 8¼ long x 7¾ wide x 9 high (21cm x 20cm x 23cm). 5lb (2.3 kg) (4.0m3/min) output. 36740-0000 fuse 10 amp. 36740-0031 115 volt AC flexmount, fuse 1.25 amp.. 8 long x 8¼ wide x 9 high (20cm x 21cm x 23cm). 5½lb (2.5kg). (4.2m3/min) output. 36740-0010 fuse 5 amp.. 6 ¾ long x 5 wide x 5 ½ high (17cm x 13cm x 14cm). 3½lb (1.6kg). (3m3/min) output.. 91/ 8 long x 9 3 /16 wide x 9 5 /8 high (23.2cm x 23.4cm x 24.5cm). 7lb (3.2kg). (7.1m3/min) output. 35515-0010 fuse 6 amp. 35440-0000 fuse 15 amp. 35440-0010 fuse 7.5 amp. In-line Blowers Rule In-line Blowers provide ventilation for bilges, engine compartments, galleys and heads. Designed for efficient, high output operation, these blowers feature our exclusive front and rear shaft seals and corrosion resistant motor housings for long life. Compact and easily installed on any flat surface, Rule In-line Blowers provide higher air flow and lower amp draw. Efficient high volume air flow. Quiet operation. Low amp draw. Slip on inlet and outlet connections. Sealed motor shaft for moisture protection. Corrosion resistant nickel plated motor housing. ABYC H2; ISO 9097. IMCI (CE). N.M.M.A. type accepted. USCG 183.410 Compliant; Ignition protected. 2/3. 5 long x 3 wide x 3 3 /16 high 1.2lb 0.55kg 140 13.6 volt, fuse 4 amp. 6 long x 4 wide x 4 3 /16 high (15.2cm x 10.2cm x 10.6cm) 1.28lb 0.58kg 240 13.6 volt, fuse 4 amp. Discharge Inlet 140-24v 27.2 volt, fuse 2.5 amp. 240-24v 27.2 volt, fuse 2.5 amp. GUNWALE 1/3 ENGINE STRINGER Radial & In-line Blowers Ventilation Blowers 09