Bolted, snap-in and guarter turn type hangers are available. Standard support distance for U12 is 600mm, in curves 300mm.

Similar documents
4 pole insulated conductor rails ULA 35A, 50A, 80A, 100A

INSULATED CONDUCTOR SYSTEMS U10

4 pole insulated conductor rails ULA 35A, 50A, 80A, 100A

4 pole insulated conductor rails UNILIFT-ULA 35A, 50A, 80A, 100A

Energy Supply Systems

Energy Supply Systems

INSULATED CONDUCTOR SYSTEMS U 20 U 30 U 40

Multipole Conductor Rail MultiLine Program 0831

MACHT STROM MOBIL. Insulated Conductor Systems U10

POWERAIL ENCLOSED CONDUCTOR SYSTEM VKS 10

INSULATED CONDUCTORS U 15 - U 25 - U 35

Series T is Ideal for:

COMPACT CONDUCTOR SYSTEMS VKS 10

POWERAIL ENCLOSED CONDUCTOR SYSTEM VKS 10

Electromotive Systems ELECTROBAR 8-Bar Conductor Bar System

Conductor Bar Safe-Lec 2 Hevi-Bar II

Conductor Bar. 8 Bar Side Contact

Conductor Bar Safe-Lec 2 Hevi-Bar II

POWER BAR SYSTEM ECONOMICAL ENCLOSED CONDUCTOR SYSTEM FOR MOBILE EQUIPMENT M O B I L E E L E C T R I F I C A T I O N

Electromotive Systems ELECTROBAR ELITE Conductor Bar System

VAHLE POWERCOM 485. Digital Data Transmission System

UNCHAINED ENERGY ELECTRIFICATION OF TRAVELLING MACHINES

Conductor Bar Safe-Lec 2 Hevi-Bar II

UNCHAINED ENERGY ELECTRIFICATION OF TRAVELLING MACHINES

4 Pole / 5 Pole Enclosed Conductor System

VAHLE POWERCOM 485. Digital Data Transmission System

POWERAIL ENCLOSED CONDUCTOR SYSTEM KBH

MACHT STROM MOBIL. Enclosed conductor system KBH SYSTEMS IN MOTION

GENERAL INDEX TR60. 6 YELLOW LINE Continuous Conductors. Max 5 Poles. 8 BLUE LINE Pre-Mounted Conductors TR85H5P. YELLOW LINE Continuous Conductors

ALINOX INSULATED CONDUCTOR RAIL FOR ELECTRICAL FEEDING OF CRANES

Multipole Conductor Rail MultiLine Program 0831

Compact Conductor System VKS10 SYSTEMS IN MOTION

VAHLE MOTOR POWERED CABLE REELS

Pro-Ductor Insulated flat conductor bar for 4, 7 or 10 conductors

Conductor Bar Selection

CONDUCTIX Insul-8 Conductor Bar

Multi Support Profile VMT SYSTEMS IN MOTION

POWERAIL CONDUCTOR SYSTEMS MKLD MKLF MKLS

Electromotive Systems ELECTROBAR FS Conductor Bar System

Magnetek ELECTROBAR FINGER SAFE (FS) Conductor Bar System

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

4-Ductor Insulated conductor bar

Cluster Bar. Conductor Bar Systems. Insul-8 Mobile Electrification. For the Electrification of: Solutions From A Single Source

QuickBridge TM. Modern Overhead Crane Bridge Electrification

1 Product Description System Layout Safety Instructions Intended Use Installation... 3

INDUSTRIAL SPRING REELS

Conductor Bar Hevi-Bar II

POWERAIL ENCLOSED CONDUCTOR SYSTEMS VKS VKL

Conductor Bar Series 831

POWERAIL ENCLOSED CONDUCTOR SYSTEM KBH

DUCT-O-BAR Figure 8 Electrical Conductor Systems

Technical data. DKK compact conductor lines engb IS eps

Hevi-Bar. Conductor Bar Systems. Insul-8 Mobile Electrification. For the Electrification of. Solutions From A Single Source

Fuse & Switch. BUCHANAN Terminal Blocks. Product Facts High Density Blocks. Fuse Blocks. Switch Blocks. Common Features of 300 & 0300 Series

Design Standard. Purpose: Design Standard:

SAFETY INTERLOCK SWITCH CONSTRUCTED WITH DUAL RESTORATION SPRINGS FEATURES

A COMPLETE LINE OF INNOVATIVE PRODUCTS

Insulated Conductor Rail SinglePowerLine Program 0813

EXPLOSION-PROOF ELECTRIC WIRE ROPE HOIST BWX

3 TM Cold Applied Barrier Boot System

1 Product Description System Layout Safety Instructions Intended Use Installation... 3

EZTray. Cable Management Made Easy

Stud connection system HSK

Gleason - JDC & JDCII Series Conductor Bar Systems

INTEGRID TRACK (120V) SPECIFICATIONS

E-LINETBS-TBE IEC EAE has full right to make any revisions or changes on this catalogue without any prior notice.

Current transformers. Current transformers

C-Rail Festoon track systems

Insulated Conductor Rail SinglePowerLine Program 0812

Conductor Bar Series 812

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

FABA. Standard Components. Conductor Bar System. publication #FABASC-04 1/1/04 Part Number: Copyright 2003 Electromotive Systems

ADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS VERSIONS MODULE 136 MODULE 106. t. 56. Without protective devices

Series 2, 3, 4 Steel Cable Ladder Steel Cable Ladder, Series 2, 3, 4 & 5

CABLE CARRIERS for -Track

HEADLINE SUBLINE HEADLINE SUBLINE. Charging Contacts - BLS/BLK US Footnotes

ENYSTAR Load Centers up to 250 A

VORTICENT C E RANGE Centrifugal fans

ZK2.5-PE-4P PI-Spring Terminal Blocks Ground with 4 connections

BATTERY CHARGING SYSTEMS. for Automatic Guided Vehicles

TRIFLEX H07RN-F CPR COMPLIANT REGULATION 305/2011/EU. Low voltage - Energy, cabling, signalling and control. reaction to fire

DUCT-O-BAR Figure 8 Electrical Conductor Systems

Product Overview Festoon-Systems for I-Beams

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

INSULATED CONDUCTOR SYSTEM U10

KRONE KGH Series Fuse-Switch-Disconnectors. For Low Voltage ABC Systems or Open-wire Overhead Networks

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

Insulated Conductor Rail SinglePowerLine Program 0812

MANUAL HOISTING TAKE THE WEIGHT OUT OF HEAVY DUTY LIFTING

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

Step 1: Collection of required data

ZK2.5-D1-PE PI-Spring Terminal Blocks Double deck with 1 ground circuit

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

The 3m long High-Tro-Reel units are installed consecutively along the side of the rail. Recommended for powering auto conveyors and monorails.

ZK4-PE PI-Spring Terminal Blocks Ground

AKRON ELECTRIC, INC. CONDUIT PRODUCTS GR SERIES... EYS SERIES... TU SERIES... XBD-50 SERIES...

Domae. The right solution for distribution boards

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

STRUCTURAL ATTACHMENT ELEMENTS

Hazardous Factory Sealed Control Devices

Transcription:

General Komay insulated conductors U12 are designed in accordance with today s international safety requirements. The shroud which envelopes the various conductors is an excellent insulator. Therefore our unipole insulated conductors guarantee utmost safety in operation. Any number of conductors can be installed side by side at minimum space requirement. Standard rail sections are 6m long, shorter sections are available. The ground conductor is identified by international colour coding. For obvious safety reasons phase and ground collectors are not interchangeable. Approved and listed by: CCC,CE and ISO9001. Hangers Bolted, snap-in and guarter turn type hangers are available. Standard support distance for U12 is 600mm, in curves 300mm. Joints Snap-in joint splices provide mechanical end electrical continuity. They include insulated protection covers. Expansion joint sections are only required in case of expansion joints in the monorail track. Feed terminals Joint assembly and mid-rail assembly feeds are available. Furthermore transfer guides and isolating assemblies allow for spade connectors. Transfer guides Transfer guides serve as an end protection of system runs and accomplish amooth smooth collector transfer in case of switches, drop sections etc. They can be supplied with or without feed clip. Isolating assemblies Conductor isolating assemblies are available for sectionalizing control circuits, maintenance bays etc. They can be supplied with or without feed clip. Curves U12 can be used for horizontal or vertical curves. A special curve tool for individual field preparation is available. Collectors The current collections are made of reinforced polyamide and stainless steelparts. These spring loaded units provide positive contact with the conductor bars and have double pick-up brushes.

U12 conductor Engineering date of shroud Electrical properties Specific resistance Surface resistance Leakage resistance Mechanical properties: Flexible strength: Tensile strength: Working temperature Flame test proof Resistance to chemicals: standard shroud color green 30-40kv/mm 5 10 15 Ohm cm 10 13 Ohm CTI600-1.1 75N/mm 2 ±10% 50N/mm 2 ±10% high temp.shroud 45kv/mm 5 10 17 Ohm cm 10 15 Ohm CTI600-1.1 95N/mm 2 ±10% 50N/mm 2 ±10% -30 ~+55-30 ~+110 no flaming particles, self-extinguishing Hydrochloric acid.concentr. gasoline, mineral oil, grease caustic soda solution 25% and 50% sulphuric acid to 50% Conductor Code length U=unipole insulated conductor 6m is standard 12=shroud size available. length, lengths are 25=conductor cross sectional area(mm 2 ) Conductor spacing on compact hangers 14mm or variable. Support spacing for straight runs 0.6m, for curves 0.3m Application Curves indoor use only. See Engineering date of min.r=0.4mm shroud Type U12/25 Weight(kg/m) 0.267 Standard shroud, color green Cat.-No.phase 668116 * Cat-No.ground 668216 * Engineering date High temperature shroud Cat.-No.phase 668316 * Cat-No.ground 668416 * Fill-in last number (1, 2, 3, 4, 5,6m suffix) in accordance to bars required. \ Conductor rail type Cross sectional area Leakage distance of covers Max.voltage Continuous ampere capacity resistanc U12/25C ** 25 30 600 100 0.745 U12/25F ** 25 30 600 40 5.415 U12/25E ** 25 30 600 10 31.56 ** C=cooper conductor F=galvanize E=stainless steel conductor Selection of Conductors in accordance to ampere load environmental conditions for power, control and data-transmission for non-corrosivent for control and data-transmission in corrosive atmospheres e

Compact double collector two-way converying for conductor spacing of 14mm 1 Plug terminal 20A 2 Plug terminal 2 20A swivel: ±15mm lift: ±15mm contact pressure 3.5N per brush ground at NO.4, other position on request. Type poles a b c weight(kg) base plate Cat.-NO. JDS2/40-1 1 80 118-0.165 663201 JDS2/40-2 2 80 118-0.245 663202 JDS2/40-3 3 80 118-0.325 663203 JDS2/40-4 4 80 118-0.405 663204 JDS2/40-5 5 80 118-0.495 663205 JDS2/40-6 6 80 118-0.575 663206 JDS2/40-7 7 80 118 53 0.735 663207 JDS2/40-8 8 80 118 53 0.825 663208 JDS2/40-9 9 80 146 53 0.925 663209 JDS2/40-10 10 80 146 53 1.005 663210 JDS2/40-11 11 120 174 80 1.125 663211 JDS2/40-12 12 120 174 80 1.205 663212 Compact double collector JDS1 for conductor spacing of 14mm 1 Plug terminal 40A swivel: ±15mm lift: ±15mm contact pressure 3.5N per brush ground at NO.4, other position on request. Type poles a b c weight(kg) base plate Cat.-NO. JDS1-1 1 80 118-0.140 663101 JDS1-2 2 80 118-0.205 663102 JDS1-3 3 80 118-0.270 663103 JDS1-4 4 80 118-0.335 663104 JDS1-5 5 80 118-0.425 663105 JDS1-6 6 80 118-0.490 663106 JDS1-7 7 80 118 53 0.625 663107 JDS1-8 8 80 118 53 0.690 663108 JDS1-9 9 80 146 53 0.786 663109 JDS1-10 10 80 146 53 0.850 663110 JDS1-11 11 120 174 80 0.995 663111 JDS1-12 12 120 174 80 1.020 663112 JDSL-are used for I-beams, fill-in last number (1-12) in accordance to bars required. JDS3* JDS3 Order-NO.:6631nn, nn are means poles of collector

Hangers Any number of conductor can be assembled 14mm/for conductor of 14mm by combining the compact hanger U12ZJA8 Al-Track=180mm U12ZJA12 Al-Track=180mm U12ZJA10 Al-Track=220mm U12ZJB10 for I-beam Compact hanger with hardware for up to 12 conductors Type weight(kg) poles Cat.-NO. U12ZJA8 0.041 8 664008 U12ZJA9 0.042 9 664009 U12ZJA10 0.055 10 664010 U12ZJA11 0.059 11 664011 U12ZJA12 0.075 12 664012 Type weight(kg) poles Cat.-NO. U12ZJB2 0.029 2 664101 U12ZJB8 0.063 8 664108 U12ZJB10 0.075 9 664110 U12ZJB11 0.081 10 664111 U12ZJB12 0.086 11 664112 Aluminium Track Compact hanger, selr-locking, for up 12 conductors on special order to fit your monorail track. Snap-in & quarter turn type hangers for typical monorail track electrification Al-Track=180mm for conductor spacing of 14mm Al-Track=220mm Al-Track=240mm I-beam

Joints system control expansion and contraction Shroud for joints UV12 0.021 663460 Feed terminal U12HT 0.01 666812 (continuous ampere capacty2 25A) 90 60 UE12 0.023 663660 120 Shroud for joints Feed clip 31 U12DJ 0.005 666912 16 Isolating assembly 133 7.5 23 Type Symbol weight(kg) Cat.-NO. UE12 0.011 663660 U12FD1 0.016 663724 U12FD2 0.021 663725 The two transfer button elements are pressed together to form a rigid, well aligned unit.

Transfer guide & end piece 25 Type weight(kg) Comprising Cat.-NO. U12DC 0.004 663867 U12DC1 0.009 663868 U12DCS 0.005 663869 U12DCS1 0.010 663870 U12DJ 0.005 666912 24 67 79 U12DC U12DCS Anchor bar for transfer guide (Aluminium) for bolting to the track, consisting of 1 aluminium profile bar, 2 hex. screws M 5w/washer, 2 locking pins 2X20. U12GDG1 U12GDG2 used in conjunction bolted hangers used in conjunction with bolted hangers for oblique cut track distance between conductor bolted hangers U12GDG3 used in conjunction with snap-in and quarter turn hanger type Poles A/mm weight(kg) Cat.-NO. U12GD1-8 1-8 118 0.042 663908 U12GD1-10 1-10 143 0.052 663910 U12GD2-8 1-8 118 0.087 663918 U12GD2-10 1-10 143 0.102 663920 U12GD3-8 1-8 118 0.024 663928 distance between conductor-surface and track U12GD3-10 1-10 143 0.029 663930

Locating clamp for each anchor point use one bolted hanger with 2 lpcating clamps per conductor bat U12GDJ 0.029 664112 Expansion section The 0.8m expansion assembly is part of the system length. type weight(kg) U12PDJ 0.256 Cat.-NO. Standard, green High temp.,gray phase ground phase ground 663530 663531 663532 663533 Joints for connecting cable for collectors, feed terminals, transfer guides and isolating assemblies. 0.5m long with quick plug 6.3 0.8(female spade connector Q 2.5 or Q 4.0)for collector long cable available Type For cable Cat.-NO. ZH2.5 2.5 667012 ZH4.0 4.0 667013 QX2.5 2.5 667014 QX4.0 4.0 667015 RDL-2.5 2.5 667025 REL-4.0 4.0 667140 Installation tools Curve tool Conductor punch tool U12WH 7.8 669001 U12DKQ 1.76 669005

Company: Date: Tel: E-mail: Fax: Internet :( URL) 1. Number of powerail installations: 2. Type of equipment to be powered: 3. Operating voltage: Volts, Phases:, Frequency: Hz Three phase voltage: AC voltage: DC voltage: 4. Track length: 5. Number of conductors: (Neutral: control: ground: ) 6. Mounted position of powerail: Powerail pendant, collector cable facing to the buttom Powerail pendant, collector cable lateral payout Support distance m(2m) Other: 7. Number of consumers per system: 8. Indoor: Outdoor: 9. Other operation conditions (humidity, dust, chemical influence etc. ) 10. Ambient temperature: min. max. 11. Position and number of feeding points (1) : 12. How will the conductor system be arranged? (1)

13. Brackets required: yes no: c/c distance beam/powerail Flange width of beam 14. Position and number of isolating sections (e.g. for maintenance): 15. Travel speed: in curves: at transfer: 16. Power consumption of the individual consumer loads: (Please consult table on reverse side) 17. Max. Voltage drop from the powerail feed point to the consumer considering starting current: 3% or % referring to nominal voltage Remarks: (1) For curved tracks, powerail with isolating sections etc., we require sketches to enable us to prepare a quotation. Puo!