PART7. Trouble Shooting

Similar documents
LUV INVERTER SERIES. Self-diagnostics and Trouble-shooting. Part 2 of 2 42/38LUV028H 42/38LUV035H 42/38LUV052H 42/38LUV065H 42/38LUV070H 42/38LUV080H

KSID MINI Split DC Inverter QUICK CONNECT Air Conditioner TROUBLESHOOTING KSID016-H215Q. Model Numbers:

QUARTZ INVERTER TROUBLESHOOTING GUIDE

LIGHT COMMERCIAL. Troublesooting

troubleshooting Outdoor Unit: KSIE009-H221-O, KSIE012-H220-O, KSIE018-H220-O KSIE024-H220-O, KSIR036-H218, KSIR048-H218

KMIR. Multi outdoor units. troubleshooting Multi zone CONDENSING UNITS MKMIR218-H221, KMIR327-H217, KMIR436-H217, KMIR545-H219.

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

Service Manual. 9. Maintenance. 9.1 Precautions before Maintenance. discharge resistance or plug of soldering iron. Installation and Maintenance

Fault Codes. J control

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

3. SERVICE TOOLS Inverter checker RSUK09-17 CLIMATE COMFORT. All Seasons. Heating. Air Conditioning. Applied Systems.

No Operation of air conditioner Explanation

6. Troubleshooting. 6-1 Basic items for trouble shooting. Samsung Electronics 17

12. Troubleshooting Items to be checked first. Samsung Electronics

9. Maintenance. 9.1 Error Code List. Service Manual. Installation and Maintenance

SERVICE MANUAL Room Air Conditioner DC Inverter Multi Split Outdoor units

SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

Driftsinstruks. Utopia kontroller feilkoder PCP-2HTE og PC-ART. Vi håper de får stor glede av et Novema kulde produkt!

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

3.2 Air Conditioning (A/C) Model 140 up to M.Y. 1995

SERVICE MANUAL MIDEA AIRCONDITIONER EUROPE MARKET SUPER DC INVERTER MULTI TYPE

GAMA DOMÉSTICA MULTISPLIT Manual de Servicio

5. TROUBLE DIAGNOSIS

SERVICE MANUAL MIDEA SUPER DC INVERTER MULTI TYPE DC MULTI OUTDOOR UNITS

4.Failure phenomenon. Mirage comes out from indoor. When the cold air from AC cools the indoor air. unit

Installation Diagram of Indoor Unit and Outdoor Unit /12K 18K 24K

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU18RLXFW AOU24RLXFW ASU18RLF ASU24RLF R410A

9. Maintenance. 9.1 Precautions before Maintenance. Service Manual. electrolytic capacitor after power off. maintenance safely.

PANASONIC FAULT CODE GUIDE. ECOi ECO-G - PACi

SERVICE MANUAL MIDEA AIRCONDITIONER SUPER DC INVERTER MULTI TYPE OUTDOOR UNITS

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units

Startup Troubleshooting

Trouble Shooting. Symptom Possible Cause Solution Power switch ON but switch Light is Off. Main power to unit Off. Switch light defective.

SUPPLEMENTAL RESTRAINTS SYSTEM

SECTION 8 TROUBLESHOOTING GUIDE

3KW Off-grid Solar Power System LFP Battery

INSTALLATION AND MAINTENANCE

SERVICE MANUAL FREE COMBI SERIES FC-E24AI, FC-E28AI

PRELIMINARY UNIT OPERATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento/Xarios/Zephyr - Unit operation Road only /Rev- #1/15


ZIP Economizer Fault Detection and Diagnostics (FDD) Table

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

Instruction Manual. Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + -

Auto Idle System Trouble Shooting

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Part 2 Functional Description

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

Parts Lists. Forward Series. Rev. Feb. 2017

Before performing symptom troubleshooting, check for power train DTCs (see GENERAL TROUBLESHOOTING INFORMATION ).

CEILING WALL type INVERTER

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

Application Engineering

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

SERVICE Manual AIR CONDITIONER OUTDOOR UNIT UM27B1C3 INDOOR UNIT AM27B1C07 AM27B1C Installation. 2. Disassembly and Reassembly

RETRIEVING DIAGNOSTIC TROUBLE CODES

Service Manual. Extractor Model XR28QP. For The. For: Troubleshooting Adjustments

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

EXTERNAL CONTROL VALVE (ECV) EQUIPPED VARIABLE A/C COMPRESSOR DIAGNOSIS PROCEDURE

Safety Notices. Dear user, thank you for choosing a HOUGHTON caravan air-conditioner. For your

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

ELECTRIC FENCE ENERGIZER SERVICE MANUAL MODEL 950 SERVICE MANUAL FOR OLLI 950 FENCE ENERGIZERS

Automobili Lamborghini s.p.a. OBDII MY 07 Section 9 Page 1 POSITIVE CRANKCASE VENTILATION (PCV) SYSTEM MONITORING

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

General Precautions. Personnel Precautions

DTC P0617 STARTER RELAY CIRCUIT HIGH

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP

A/C SYSTEM SPECIFICATIONS

1. SPECIFICATIONS 01-2

Electric expansion valve stepper motor. Controller for elec. expansion valve Connector for controller expansion valve

Customer Training Catalog Training Proposal. Training Description for Network Energy COMMERCIAL IN CONFIDENCE 1

ROCKLEA TRUCK ELECTRICAL. Sleeper Air NXT. Owner s Manual. Revision th March 2013

General Description. Product Specification. Document Digital Temperature Interlock

ENGINE IMMOBILISER SYSTEM

Application Engineering

MODEL: DCT 35 INV-Si DCT 50 INV-Si DCT 70 INV-Si DCT 100 INV-Si DCT 140 INV-Si DCT 170 INV-Si

Malfunction Criteria and Threshold Value Adaptive value. Secondary Parameters with Enable Conditions. >50.8 S Engine load 9-45% Delta fuel adaptation

3.3 Air Conditioning (A/C) Model 202

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

ENGINE IMMOBILISER SYSTEM

DTC P0657 Actuator Supply Voltage Circuit / Open

HGM-MZ Multi-Zone Monitor Annual Maintenance And Troubleshooting Guide

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Parts Lists. Novel Series. Rev. Feb. 2017

Inverter scroll compressors VZH single and manifold

Air Conditioning System

01 02B ON-BOARD DIAGNOSTIC [ENGINE CONTROL SYSTEM (FS)]

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

REAR AXLE <FWD> GROUP 27A 27A-1 CONTENTS GENERAL INFORMATION... 27A-2 SPECIAL TOOLS... 27A-4 ON-VEHICLE SERVICE... 27A-5 SPECIFICATIONS...

OUTDOOR UNIT CONTROLLER (OUC)

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Application Engineering Europe

Air Conditioning System

STONESTAR AUSTRALIA PTY LTD

4.2 Component Identification

TECHNICAL MANUAL 2013 CONSOLE MULTI DC INVERTER

ANTI-LOCK BRAKE SYSTEM

Models: 12 and 18. Models: 24 to 60

Transcription:

PART7. Trouble Shooting 1. Indoor Unit Error Display Display E0 E1 E2 E3 E5 LED STATUS EEPROM parameter error Indoor unit and outdoor unit communication protection Zero-crossing signal error Indoor fan speed has been out of control Open or short circuit of outdoor temperature sensor or outdoor unit EEPROM parameter error E6 E7 P0 P1 P2 P4 Open or short circuit of room or evaporator coil temperature sensor Outdoor fan speed has been out of control IBM malfunction or IGBT over-strong current protection Over voltage or too low voltage protection Temperature protection of compressor top. Inverter compressor drive error te: E4 & P3: Reserved function. PART7, 1

2. Diagnosis and Solution 2.1 EEPROM parameter error diagnosis and solution Shut off the power supply and turn on it 5s later The problem comes out again Is the EEPROM chip plugged in indoor unit PCB well? Correct the connection Replace the main PCB of indoor unit PART7, 2

2.2 Indoor unit and outdoor unit communication protection error diagnosis and solution Turn off the power supply, after 1 minute, connect the power supply, turn on the unit with remote controller The unit does not work normally Check the wiring between indoor unit and outdoor unit. Is the connection of L, N, S and GND good? Reconnect and retest Is the LED4(red) bright and LED1(yellow) blinking on outdoor PCB? Replace indoor unit PCB and repower The unit does not work normally The power supply for outdoor PCB is fail. Check the wiring on outdoor PCB comparing with wiring plate. Is the connection good? Replace the outdoor outdoor e-box. unit e-box Correct the connection PART7, 3

2.3 Fan speed has been out of control diagnosis Shut off the power supply and turn on it 5s later The unit does not work normally Turn off the unit, rotate the cross fan. Does it rotate freely? Disassemble the connection between fan and motor, check if the bearing is normal. If not, change the bearing. If yes, follow the below step. Is the fan motor connector and connection good? Is the voltage being applied to the fan motor? Replace the fan motor Replace the PCB 2.4 Open or short circuit of temperature sensor diagnosis and solution Check the connections between the sensors and the PCB. Are the connections good? Replace the sensor and check if the errors happen again? Replace the outdoor unit PCB PART7, 4

2.5 IGBT over-strong current protection diagnosis and solution Check whether the connections between outdoor PCB and IPM are good? Check whether the IPM is fixed to radiator tightly Fastening the IPM to the radiator Replace the IPM The unit does not work normally Replace the compressor 2.6 Over voltage or too low voltage protection diagnosis and solution Is the power supply good? Make sure the power supply is normal. Replace the outdoor unit e-box. 2.7 High temperature protection of compressor top diagnosis and solution Does the compressor operate? Is the connection good? Reconnect it Is refrigerant circulation volume normal? Is protector normal? Replace it, Charge refrigerant Is the abnormality the same after gas charging? Replace the outdoor unit PCB. There is block (Such as capillary or welded points of the pipes.) PART7, 5

2.8 Inverter compressor drive error diagnosis and solution Is the connection of compressor good? Is the wiring sequence right? The voltage range proper? Reconnect and retry Replace the outdoor unit PCB Replace inverter compressor. 2.9 Zero crossing detection error This is alarm signal when the main chip can t detect over-zero signal. When such failure occurs, the main control board must have fault. 3. Key parts checking 3.1 Compressor checking Model: DA108X1C-20FZ3 Blue - Red 0.71Ω Blue - Black Red - Blue (20 ) Model: DA130S1C-20FZ Blue - Red 0.95Ω Blue - Black Red - Blue (20 ) PART7, 6

Model: DA150S1C-20FZ Blue - Red 0.95Ω Blue - Black Red - Blue (20 ) Model: DA250S2C-30MT Blue - Red 0.55Ω Blue - Black Red - Blue (20 ) PART7, 7

3.2 Outdoor Fan Motor Model: YDK24-6G Black - Red 372Ω (20 ) Blue - Red 249Ω (20 ) Yellow - Blue 132Ω (20 ) Model: YDK50-6C Black - Red 114Ω (20 ) Blue - Red 188Ω (20 ) Yellow - Blue 172Ω (20 ) Model: YDK55-6G Black - Red 191Ω (20 ) Red -Yellow 220Ω (20 ) PART7, 8

Model: YDK53-6N Black - Red 87Ω (20 ) Red -Yellow 162Ω (20 ) Model: YDK100-6T Black - Red 63Ω (20 ) Red -Yellow 57Ω (20 ) PART7, 9

3.3 Indoor Fan Motor Model: RPG20D Black - Red 400Ω±8% (20 ) White - Black 383Ω±8% (20 ) Model: RPG28D Black - Red 260Ω±8% (20 ) White - Black 385Ω±8% (20 ) PART7, 10