RECESSED TRACK (120V) SPECIFICATIONS

Similar documents
SURFACE TRACK (120/250V) SPECIFICATIONS

INTEGRID TRACK (120V) SPECIFICATIONS

MOUNTING SYSTEMS SPECIFICATIONS

GEMINI HOUSING SPECIFICATIONS

SURFACE CONTROLTrack SPECIFICATIONS

LSI 20 Series 30A, 120V Surface Busway Components 1

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

WARNING NORDIC ALUMINIUM LIGHTING TRACK SYSTEMS

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

TRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series

IMPORTANT SAFETY INSTRUCTIONS

NT-300 Series Single Circuit Track System & Accessories

Juno Trac-Master Trac Lighting Systems. Comprehensive line and low voltage track systems

LIGHTPLANE 1 RECESSED - LP1R

INSTALLATION INSTRUCTION W Track Suspension system

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

Installation Instructions for Monorail 2 Circuit 2 X 250 Watt Sloped Surface Mount Magnetic Transformer 120 Volt Input to 12 Volt Single Feed Output

Catalog # Project. Comments. Prepared by. L653 L =12'Nominal Actual length: 140-1/8" [3559mm] W=1 3/8" [3559mm] H =11/16" [17.5mm]

Snake Bus Power Distribution

A B C D E F. b.tools Required (supplied by others) 3/16" Drill Bit 3/8" Wrench Phillips Head Screwdriver

INSTALLATION INSTRUCTIONS For Light*Waves Flex II Kit with 300-Watt remote transformer

A B C D E F. Tools Required (supplied by others)

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

M36 LED Recessed Quickship

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

Electrical Applications. Metal Framing & Cable Tray Superstrut Metal Framing System. Column A. Design Data: Materials: Column B

FACT SHEET Standard: Electrical Safety

poollux Power plx-pw60 & plx-pw100

Luminaire PROFILE-SPOKE 15 UP 85 DN LED (PS1-D) Type. Notes. Performance Summary D OPTIONS 3S A 28 W B 34 W C 44 W D 57 W

SECTION PANELBOARDS

COMPACT BUSWAY 40 & 60 AMP HOUSING

LAD6 6 LED Architectural Downlight

Installation Instruction

Design Standard. Purpose: Design Standard:

RELOC Modular Wiring Specialty Lighting and Power Systems

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

LAD8 8 LED Architectural Downlight

PROFILE 50 Up 50 Dn PF1-E. Luminaire PROFILE - 50 UP 50 DN LaED (PF1-E) Type. Project. Product. Notes. Performance Summary

LAD4 4 LED Architectural Downlight

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

LumeLEX 2084 SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

Alphabet By Ledra Brands

Project. Comments. Prepared by. 20-1/8" [511mm] 44-1/8" [1121mm] 92-1/8" [2340mm] 140-1/8" [3559mm]

RECESSED WALL WASH MOUNT

LED Recessed Troffer Retrofit Kit

SAVE THESE INSTRUCTIONS

Juno Trac-Lites System A complete and customizable track system with an array of features

Round or Square Type Low-Profile Housing with Toroidal Transformer for Flangeless Trims E3_LF-HDSM-WR_ 1.0

Have You Been Grounded Lately

PDI PowerWave 2 Bus System

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

Elegance Electrician s Installation Guide

Luminaire PROFILE-SPOKE Ind. Up Dn Control (PS3-B) Type. Project. Notes. Performance Summary OPTIONS 4S D 76 W 3S D 57 W

Universal Retrofit System Installation Instructions Revised:

INSTALLATION INSTRUCTIONS

Generator Fire Safety: Generator assemblies should be located outside the building.

INSTALLATION INSTRUCTIONS RECESSED EXTRUSIONS WITH LED TAPE

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS.

Luminaire PROFILE-SPOKE 40UP 60 DN LED (PS1-A) Type. Notes. Performance Summary OPTIONS CONTROLS

LOOP 65 Up 35 Dn LS1-A. Luminaire LOOP - 65 UP 35 DN LED (LS1-A) Type. Project. Product. Notes. Performance Summary OPTIONS

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION

PROFILE 100 Dn PF1-B. Luminaire PROFILE DN LED (PF1-B) Type. Project. Product. Notes. Performance Summary

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

Electric Range installation manual

LAD8R - Remodel 8 LED Architectural Downlight

LAD6R - Remodel 6 LED Architectural Downlight

BUSWAY Low Voltage (Pow-R-Flex)

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

GP Dimming Panels 230 Volt (CE)

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

MASTERsine Inverter PXA Series Installation Guide

2 CIRCUIT TRACK. Notes: INSTALLATION PROFILE SURFACE TRACK COLOR. Page 1/9. Date :12/06/17 Rev.02 WHITE POWDER COAT SILVER ANODIZED

POOL BARON Nicheless Color Changing LED Pool Light

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Installation Instructions 4 Gravity Enhanced Color Adjustable

Museum Alkmaar - Alkmaar, Netherlands

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Product Selection Guide

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

AMPLIFIER A OR B SELECTOR

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT

Industrial Control Transformers

2016 Photovoltaic Solar System Plan Review List

Ciros P-ID-5200 Pendant-Mounted Indirect/Direct

Installation Instructions Central Battery Units

Contractors Guide Central Inverter System Installation

Sky FactoryTM toll free

Installation Instructions MX LED Enhanced Color Adjustable

INSTALLATION INSTRUCTIONS HYLYTR WALL GRAZER

RECESSED ASYMMETRIC MOUNT. Project. Type. Notes TECHZONE TM AND LOGIX TM COMPATIBLE

Multi-Pak Group Control

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

Scan QR Code to view video

North America Phase Converters & Electrical Supply

Transcription:

RECESSED TRACK (120V) SPECIFICATIONS GENERAL Recessed track shall be approved by the NEC for flush-mounting into ceiling or any flat surface. Recessed Track shall allow fixtures to be easily focused, switched, dimmed, accessorized, and removed as desired. Recessed Track shall have a twelve year warranty from date of shipment. One Ckt 120V Recessed Track CEILING CHANNEL (BY OTHERS) PERFORATED HANGER MECHANICAL Recessed Track shall be constructed of.125 inch (3mm) extruded aluminum. Recessed Track shall have the same overall dimensions and physical appearance for both one and two circuit models. Recessed Track shall be available in and configurations with high temperature white baked paint finish on all exposed surfaces. Recessed Track shall have an overall height of 1.63 inches (42mm) and overall width of 2.81 inches (72mm). Recessed Track shall have an overall height of 1.63 inches (42mm) and overall width of 2.81 inches (72mm). Track available with 5/8 inch (16mm) height mounting fin to accommodate 5/8 inch sheet rock, or plaster. Recessed Track shall be available in nominal 4 foot (1.2m), 8 foot (2.4m), and 12 foot (3.7m) lengths and comes complete with all necessary hardware and components. Recessed Track shall be field cuttable to any length with a single cut. Recessed Track system shall be available with End Feed, End Cap, Straight Mini-Joiner, Straight Joiner/Feeder, X Joiner/Feeder, L Joiner/Feeder, and T Joiner/Feeder as standard components. Recessed Track shall have integral side mounting channels to accept perforated mounting straps. ELECTRICAL Recessed Track and components shall be UL and CUL listed, CE Certified, and comply with the National Electric Code standards for Lighting Track. One and two circuit Recessed Track shall be rated at 120/250 volt, 50/60 Hz, 2400 watts maximum each circuit. Each 20 amp/120/250 volt circuit shall be comprised of flat copper busbars and have a separate neutral busbar for each circuit. The neutral busbar shall be oversized to be com parable to #10 gauge 30 amp wire to reduce the possibility of overheating due to nonlinear loads and harmonics. Track shall have integral wiring channels for six (6) additional #12 THHN wires to create three (3) additional 20 amp/120/250 volt circuits, which can be dropped into any Joiner/Feeder, for a total track power capacity of 100 amps. A separate grounding busbar shall be integral in all track lengths. All busbars shall be insulated to prevent contact with aluminum extrusion. Recessed Track shall have electrical feed capability through all Joiners/Feeders using either 1/2 or 3/4 U. S. trade size knock-outs (.875 inch diameter, 22mm or 1.125 inch, 29mm). Joiner/Feeders can be electrically field modified by removing the Lexan TM cover and rerouting internal pre-wired jumpers. All Joiner/Feeder covers shall be available in White GE fiber reinforced Lexan TM. One and two circuit Recessed track lighting with separate neutral busbars shall have the ability to have each circuit separately dimmed as required when using standard voltage and low voltage fixtures with either magnetic or electronic transformers. Recessed Track shall have the ability to be dimmed or switched in selected sections in addition to dimming or switching an entire recessed track configuration or recessed track run. 13/16" 2 7/8" 4 3/8" Two Ckt 120V Recessed Track CEILING CHANNEL (BY OTHERS) PERFORATED HANGER One Ckt 120V Recessed Track Two Ckt 120V Recessed Track CEILING CHANNEL (BY OTHERS) 13/16" 2 7/8" 4 3/8" 5/8" SHEET ROCK 5/8" SHEET ROCK 1 5/8" 1 5/8" FIXTURE FITTING INTERFACE Recessed Track shall accept only GE fiber reinforced Lexan TM fixture fittings which positively lock into recessed track and cannot be energized by integral switch until safety interlock handle is in the closed position. Safety interlock shall also prevent fixture fitting removal from recessed track unless the switch is in the off position. Upon insertion of fixture fitting into recessed track, grounding connection from fixture fit - ting to track shall be automatically completed before any electrical contact is made with busbars. When removing fixture fitting from track, the grounding connection shall auto - matically be disconnected last. The fixture fitting shall recess into the track, creating a minimal profile below the track. PERFORATED HANGER 08/18 www.lightingservicesinc.com Recessed Track 1 13/16" 2 7/8" 1 5/8" 5/8"SHEET ROCK

RECESSED TRACK (120V) CONFIGURATIONS Straight Run Configuration ( Version Shown) END CAP END CAP MINI JOINER TRACK SECTION TRACK SECTION STRAIGHT JOINER / FEEDER END FEED TRACK SECTION END FEED One Circuit Grid Configuration L JOINER/FEEDER TRACK SECTION 1 CKT T JOINER/FEEDER (LEFT) 1 CKT T JOINER/FEEDER (RIGHT) X JOINER/FEEDER 1 CKT T JOINER/FEEDER (LEFT) 1 CKT T JOINER/FEEDER (RIGHT) 08/18 www.lightingservicesinc.com Recessed Track 2

RECESSED FLANGELESS TRACK (120V) COMPONENTS Key Features / Applications UL and CUL listed, CE Certified, Dry Location IBEW union made at LSI plant in USA Specification grade heavy duty.125 (3mm) extruded aluminum track Track available with 5/8 inch (16mm) height recessed flange to accommodate sheet rock or plaster 4 foot (1.2m), 8 foot (2.4m), 12 foot (3.7m) field cuttable lengths complete with 14 inch perforated hanger straps for mounting hardware. One circuit 20 amp or two circuit 40 amp capacity/120/250 volt 100 amp total capacity when using integral wireways Copper busbars equivalent to #12 AWG wire used as circuit and ground track conductors Oversized copper busbars equivalent to #10 AWG wire used as neutral track conductors Separate neutral track conductor used for each circuit track conductor Separate copper grounding busbar used throughout track system All Joiner/Feeders, Mini-Joiners and End Feeds are injection molded of GE fiber reinforced Lexan All Joiner/Feeders are prewired and simply couple into track and can be easily field modified by changing internal jumper wires Fixture fitting recesses into track for minimum profile LSI recessed track can be mounted directly into any surface 5-0 above finished floor. Track Sections-Recessed 3'- 6 13/16" 7'- 6 13/16" 11'- 6 13/16" 120V Recessed Track Sections are open ended extrusions used to form track runs or configurations to be used in conjunction with an End Feed, End Cap, Straight Joiner/Feeder, Straight Mini Joiner, L Joiner/Feeder, T Joiner/ Feeder, and X Joiner/Feeder.Track Section lengths are nominal 4 foot (1.2m), 8 foot (2.4m) and 12 foot (3.7m) and are supplied complete with galvanized perforated straps for mounting. Track is field cuttable. Nominal Length 4 ft 8 ft 12 ft White One Ckt 81310 81320 81330 Two Ckt 82310 82320 82330 Security/Worklight Track Recessed 16 3/4" 120V Recessed Security/Worklight Track is a separately fed one circuit Track Section, suitable for most LSI track fixtures, that integrates into any LSI Track run or configuration at any location. Consult fixture cutsheet. LSI fixtures (add suffix EF) mechanically lock into Security/Worklight Track by means of special hardware and do not have on/off switches. One Ckt 17 Joiner, End Feed, End Cap Section White 81351 Top Feed Security /Worklight Joiner/Feeder Recessed 120V Recessed Security/Worklight Joiner/Feeder is used to mechanically and electrically couple two lengths of track in a straight line. It is top fed to energize the track through 1/2 conduits. Consult fixtures (add suffix EF) mechanically lock into Security/Worklight Track by means of special hardware and do not have on/off switches. Silver Two Ckt 82054 Black Two Ckt 82254 White Two Ckt 82354 Unimount-Recessed 120V Recessed Unimount is a compact Recessed Track assembly which will accept most single LSI track fixtures up to 500 watts. Two piece construction allows for wiring and inspection. White One Ckt 81361 10 3/4" End Feed-Recessed 120V Recessed End Feed is used when track run is to be fed from the end of a run. The end feed is top fed directly from electrical cable to energize the track. White One Ckt 81300 Two Ckt 82300 End Cap-Recessed 120V Recessed End Cap is used for mechanically ending any straight run, individual Track Section, or open con - figuration Track Section. End cap is insulated on inside only. White One & Two Ckt 80303 1/8" 08/18 www.lightingservicesinc.com Recessed Track 3

RECESSED FLANGELESS TRACK (120V) COMPONENTS Straight Joiner/Feeder Recessed 120V Recessed Straight Joiner/Feeder is used to in a straight line. The Straight Joiner/Feeder is top fed directly from cable to energize the track. Internal joiner wiring can be modified in the field. White One Ckt 81304 Two Ckt 82304 Straight Mini-Joiner- Recessed 120V Recessed Straight Mini-Joiner is used to in a straight line. Not for use as feeder. Alignment bars with screws included. White One Ckt 81311 Two Ckt 82311 0" L Joiner/Feeder-Recessed 120V Recessed L Joiner/Feeder is used to in an L right angle configuration. This L Joiner/Feeder can also be top fed directly from electrical cable to energize the track. Internal joiner wiring can be modified in the field. White One Ckt 81305 Two Ckt 82305 4 3/4" T Joiner/Feeder-Recessed 120V Recessed T Joiner/Feeder is used to mechanically and electrically couple any three lengths of track in a T configuration. This T Joiner/Feeder can also be top fed directly from electrical cable to energize the track. Internal Joiner wiring can be field modified. Note that in the one circuit version, a right or a left T must be ordered and must be used directly opposite each other when used in a configuration so that busbar continuity is maintained. For two circuit track, a left and right T is not necessary. Left Right Joiner Joiner White One Ckt 81306 81307 Two Ckt 82308 82308 X Joiner/Feeder-Recessed 120V Recessed X Joiner/Feeder is used to mechanically and electrically couple any four lengths of track in an X configuration. This X Joiner/Feeder can also be top fed directly from electrical cable to energize the track. Internal joiner wiring can be modified in the field. White One Ckt 81309 Two Ckt 82309 Current Limiter LSI Track Current Limiters integrate directly into single circuit runs, available in the following amperages: 3 AMP (360 Watts); 5 AMP (600 Watts); 8 AMP (960 Watts); 12 AMP (1440 Watts). 3 AMP 5 AMP 8 AMP 12 AMP White TCLR3W TCLR5W TCLR8W TCLR12W 9" 08/18 www.lightingservicesinc.com Recessed Track 4

RECESSED FLANGED TRACK (120V) COMPONENTS Track Sections-Recessed 3'- 6 13/16" 7'- 6 13/16" 11'- 6 13/16" 120V Recessed Track Sections are open ended extrusions used to form track runs or configurations to be used in conjunction with an End Feed, End Cap, Straight Joiner/Feeder, Straight Mini Joiner, L Joiner/Feeder, T Joiner/Feeder, and X Joiner/Feeder. Track Section lengths are nominal 4 foot (1.2m), 8 foot (2.4m) and 12 foot (3.7m) and are supplied complete with galvanized perforated straps for mounting. Track is field cuttable. Nominal Length 4 ft 8 ft 12 ft White One Ckt 91310 91320 91330 Two Ckt 92310 92320 92330 Security/Worklight Track Recessed 120V Recessed Security/Worklight Track is a separately fed one circuit Track Section, suitable for most LSI track fixtures, that integrates into any LSI Track run or configuration at any location. Consult fixture cutsheet. LSI fixtures (add suffix EF) mechanically lock into Security/Worklight Track by means of special hardware and do not have on/off switches. All One Ckt 17 17 17 Joiner End Feed End Cap Section Section Section White 91350 91351 91352 1' 16 3/4" Unimount-Recessed 120V Recessed Unimount is a compact Recessed Track assembly which will accept most single LSI track fixtures up to 500 watts. Two piece construction allows for wiring and inspection. White One Ckt 91361 12 11/16 End Feed-Recessed 120V Recessed End Feed is used when track run is to be fed from the end of a run. The end feed is top fed directly from electrical cable to energize the track. White One Ckt 91300 Two Ckt 92300 6 3/16" End Cap-Recessed 120V Recessed End Cap is used for mechanically ending any straight run, individual Track Section, or open configuration Track Section. End cap is insulated on inside only. White One & Two Ckt 90303 1" Straight Joiner-Recessed 120V Recessed Straight Joiner/Feeder is used to in a straight line. The Straight Joiner/Feeder is top fed directly from cable to energize the track. Internal joiner wiring can be modified in the field. White One Ckt 91304 Two Ckt 92304 08/18 www.lightingservicesinc.com Recessed Track 5

RECESSED FLANGED TRACK (120V) COMPONENTS Straight Mini-Joiner- Recessed 120V Recessed Straight Mini-Joiner is used to in a straight line. Not for use as feeder. Alignment bars with screws included. White One Ckt 91311 Two Ckt 92311 0" L Joiner/Feeder-Recessed 120V Recessed L Joiner/Feeder is used to mechani - cally and electrically couple any two lengths of track in an L right angle configuration. This L Joiner/Feeder can also be top fed directly from electrical cable to energize the track. Internal joiner wiring can be modified in the field. White One Ckt 91305 Two Ckt 92305 4" T Joiner/Feeder-Recessed 120V Recessed T Joiner/Feeder is used to mechani - cal ly and electrically couple any three lengths of track in a T configuration. This T Joiner/Feeder can also be top fed directly from electrical cable to energize the track. Internal Joiner wiring can be field modified. Note that in the one circuit version, a right or a left T must be ordered and must be used directly opposite each other when used in a configuration so that busbar continuity is maintained. For two circuit track, a left and right T is not necessary. Left Right Joiner Joiner White One Ckt 91306 91307 Two Ckt 92308 92308 X Joiner/Feeder-Recessed 120V Recessed X Joiner/Feeder is used to mechan - ically and electrically couple any four lengths of track in an X configuration. This X Joiner/Feeder can also be top fed directly from electrical cable to energize the track. Internal joiner wiring can be modified in the field. White One Ckt 91309 Two Ckt 92309 Current Limiter LSI Track Current Limiters integrate directly into single circuit runs, available in the following amperages: 3 AMP (360 Watts); 5 AMP (600 Watts); 8 AMP (960 Watts); 12 AMP (1440 Watts). 3 AMP 5 AMP 8 AMP 12 AMP White TCLRF3W TCLRF5W TCLRF8W TCLRF12W 9 1/8" 08/18 www.lightingservicesinc.com Recessed Track 6

RECESSED FLANGED TRACK (120V) COMPONENTS Raceway Cover Field cuttable Raceway Covers are used to enclose additional lay-in circuit wiring in top section of track. Nominal Length 4 Ft 8 Ft 12 Ft Galvanized 30613 30614 30615 3'-6 3/4" 7'-6 3/4" 11'-6 3/4" Recessed / Hanger Support Clip Extruded Hanger Support Clip for LSI recessed flanged or flangeless track. In place of galvanized perforated straps use hanger support clip as alternate mounting method. For normal usage, LSI recommends two hanger support clips per 4 foot (1.2m) length, two hanger support clips per 8 foot (2.4m) length and three hanger support clips per 12 foot (3.7m) length. Two clips per package. 1/4 diameter hole. White One & Two Ckt 90325 Display Hook Display Hook is used to mechanically hang an item from the track without electrifying it. Do not exceed 20 lbs. at minimum spacing of two feet. Silver One & Two Ckt 30761 Weight Support Bar Weight Support Bar provides threaded nipple and nuts to mount an item to track without electrifying it. Do not exceed 20 lbs. at minimum spacing of two feet. Nipple size 1/8-27 NPS (.406 diameter). Silver One & Two Ckt 30762 5" Track Closure Cover 3'- 4" 7'- 4" 11'- 4" Field cuttable Noryl Track Closure Covers are used to enclose the open face of the track and simply snap into place. Nominal Length 4 Ft 8 Ft 12 Ft Silver 30165 30166 30167 Black 30265 30266 30267 White 30365 30366 30367 08/18 www.lightingservicesinc.com Recessed Track 7

RECESSED TRACK (120V) INSTALLATION General Notes When installing or using this track system, basic safety precautions should always be followed, including the following: Read all instructions. Do not install this track in damp or wet locations. Do not install any part of the track system less than five feet from floor. Do not install any fixture assembly closer than six inches from any curtain or similar combustible material. Disconnect elec trical power before adding to or changing the configuration of the track. Check with a qualified electrician. Do not attempt to energize anything other than lighting track fixtures on the track. To reduce the risk of fire and electric shock, do not attempt to connect power tools, extension cords, appliances and the like to the track. Install per NEC and local codes. Save these instructions. Assembling Insert End Feed or any other Joiner/Feeder completely into track section and tighten Phillips head screws on alignment bars which align with slots on both sides and top of track section. After alignment, tighten Philips head screw of feeder block. Mounting PERFORATED HANGER STRAPS SLOTS RECESSED TRACK SECTION Fasten track directly to ceiling structure with hanger straps or through field drilled holes and hardware (by others) capable of withstanding a 50 pound point load in any direction. Mount Track in compliance with NEC Lighting Track Article #410-101 (Installation), #410-104 (Fastening) and any other applicable codes. To prevent distortion of the track opening which may prevent insertion of fixture fittings do not over tighten mounting screws. Perforated hanger straps are located in slots along both sides of the track sections. LSI recommends a minimum of two mounting points per section of track. LSI track can be mounted on centers up to 6-0, but must have a minimum of two mounting points per track section. BUILDING STRUCTURE MOUNTING HARDWARE RECESSED TRACK Ceiling Integration Track sections are available for sheetrock and plaster ceilings. sections are available with 5/8" (16mm) fin for sheetrock and plaster ceilings. Track should be mounted in such a way as to prevent vertical movement when installing or removing fixtures from the track. Refer to IS-0029 or IS-0030 for more details. FIN 08/18 www.lightingservicesinc.com Recessed Track 8

RECESSED TRACK (120V) INSTALLATION Field Cutting All LSI Recessed track sections can be easily field cut using a sharp hacksaw or a chop saw with a non-ferrous blade such as an Oldham commercial carbide series metal blade. Cut the aluminum track with one straight cut to the desired length. Be sure to remove any burrs on the aluminum, copper and Noryl liner or this may affect the electrical and mechanical connection of components to track. RECESSED TRACK SECTION STRAIGHT CUT TO MATCH FIELD CUT TRACK Electrical Remove the Lexan cover from any End Feed or Joiner/Feeder, bring conductors through combination 1/2, 3/4 U.S. trade size knock-out (.875 diameter [22mm], 1.125 diameter [29mm]) in top of Joiner/Feeder conduit plate knock-out and attach conductors to identified terminals. CONDUIT PLATE WITH COMBINATION KNOCKOUT COMBINATION KNOCK-OUT TRACK GROUNDING TERMINAL (GREEN) CKT 1 (BRASS) NEUTRAL 1 (SILVER) Additional Circuits LSI Track has integral wiring channels for six additional #12 THHN wires to create three additional 20 amp circuits with separate neutrals. Raceway covers must be used in this application. END FEED LEXAN COVER Straight Mini Joiner The straight mini joiner is used to mechanically couple any two lengths of track in a straight line with a flush fit. Not for use as a feeder. There is an indicator line on face of mini-joiner to ensure proper engagement into each end of track. The two alignment bars with screws, included with the mini-joiner, must be inserted into the track section before joining sections. Tighten screws after alignment has been completed, don t overtighten. MINI-JOINER ALIGNMENT BARS MINI-JOINER ALIGNMENT SLOT Installing LSI Fixtures To insert a fixture fitting into the track, the switch must be in the off position, with the handle open. Insert the fixture fitting straight up into the track until it seats evenly, close handle completely and switch on. If using one circuit track, make sure that the brass contacts which protrude from the side of the fixture fittings are inserted facing the copper busbars. If using two circuit track, inserting the fixture fitting in one direction will connect to circuit one. Removing and reversing the direction of the fitting will connect to circuit two. TWO CIRCUIT RECESSED TRACK SWITCH ON HANDLE CLOSED SWITCH OFF HANDLE OPEN 08/18 www.lightingservicesinc.com Recessed Track 9