LIGHTPLANE 1 RECESSED - LP1R

Similar documents
INSTALLATION INSTRUCTIONS HYLYTR WALL GRAZER

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

RECESSED TRACK (120V) SPECIFICATIONS

Customer service: or Upper mounting ring. Canopy

Track Accessories. Single Circuit Track. L Connector T Connector X Connector. Mini Connector Floating Canopy End Feed Kit.

D3 INSTALLATION GUIDE

PROFILE 50 Up 50 Dn PF1-E. Luminaire PROFILE - 50 UP 50 DN LaED (PF1-E) Type. Project. Product. Notes. Performance Summary

CFP-LED Contractor Select Flat Panel. Installation Instructions

MIRRORLITE RECESSED EMERGENCY LIGHTING

When using electrical equipment, basic safety precautions should always be followed including the following:

NT-300 Series Single Circuit Track System & Accessories

Installation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

LOOP 65 Up 35 Dn LS1-A. Luminaire LOOP - 65 UP 35 DN LED (LS1-A) Type. Project. Product. Notes. Performance Summary OPTIONS

Elle Surface Mounting Instructions

QUICK START INSTALLATION GUIDE ANALOG - INTELLIGENT POWER CENTER (IPC)

Inde-Pendants Family. 32L Cylinder with Ring Chicago Plenum Ceiling Types. Document No

Installation Instruction

PROFILE 100 Dn PF1-B. Luminaire PROFILE DN LED (PF1-B) Type. Project. Product. Notes. Performance Summary

High Bay Luminaire Series

SURFACE TRACK (120/250V) SPECIFICATIONS

Round or Square Type Non-IC Adjustable Housing with Toroidal Transformer for Flangeless Trims E3_L_-HANM_ 1.7

Round or Square Chicago Plenum Hi-lume Wall Wash Housing with LED Lamp for Flanged Trims E3_F_-L_WC-HL 1.0

The Tracking Magnet Recessed High-tech LED lighting system for interior architecture

Round or Square Type Low-Profile Housing with Toroidal Transformer for Flangeless Trims E3_LF-HDSM-WR_ 1.0

INTEGRID TRACK (120V) SPECIFICATIONS

FINA SUSPENDED INSTALLATION INSTRUCTIONS

Installation Instructions MX LED Enhanced Color Adjustable

HBDBM High Bay Series

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

Model: LUM-P1-40WCDS LUM-P7-50WCDS

General Installation Instructions LED

MOUNTING SYSTEMS SPECIFICATIONS

LAD6 6 LED Architectural Downlight

Accessories. Accessories. Meter Mounting Equipment

Luminaire PROFILE-SPOKE 15 UP 85 DN LED (PS1-D) Type. Notes. Performance Summary D OPTIONS 3S A 28 W B 34 W C 44 W D 57 W

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

The Gallery System DIRECTIONS. Components of the System

LAD8 8 LED Architectural Downlight

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

LED Recessed Troffer Retrofit Kit

Contractors Guide Central Inverter System Installation

ECO-T LED RECESSED TROFFER USER MANUAL

Avenue A. Grid Mount. Drywall Flange. lens. Narrow aperture high performance T5/T5HO asymmetric wall wash.

NOTE: The orientation of the mounting brackets are critical. (See Figure 4)

Avenue A. Grid Mount. Drywall Flange. lens. Narrow aperture high performance T5/T5HO asymmetric wall wash.

LAD4 4 LED Architectural Downlight

Ultra-Thin Recessed LED Light Installation Guide

Luminaire Support Location Cable Mounting Kit. Non-Power Feed

Recessed Square. Downlight. BASYS with LED Light Engine BS4DLED BS4D LED. Type: Project: online Find it Fast 756. IBEW Union Made BASYS LED HOUSING

Outdoor Installation Using an Electronic LED Power Supply (TE-60L-12)

CIRRUS SUSPENSION WALL WASH WITH REMOTE POWER, END FEED

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

LIGHTPLANE 11 RECESSED

800 TO 9000 LUMEN 8 LED SILENT CEILING DOWNLIGHT HYPERBOLIC OPEN APERTURE L8 SERIES

MaxLite LED Linear HighBay Fixtures

LED Edge-Lit Flat Panels

Model Numbers SAVI-NOTE75, SAVI-NOTE150

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

avenue led features dimensional data performance Narrow 3" slot LED with frosted satin lens.

ZIP LIGHT LED LUMINAIRE

DLTC. lighting controls. transfer circuit for use with low-voltage down-lighting. features

Installation Instructions

Installation Instructions

IC 4 5 YEAR RECESSED MOUNT. Project. Type. Notes 1 9/16 PERFORMANCE PER LINEAR FOOT AT 4000K CONTROL SENSORS

Recessed Downlights. Zas

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Luminaire PROFILE-SPOKE Ind. Up Dn Control (PS3-B) Type. Project. Notes. Performance Summary OPTIONS 4S D 76 W 3S D 57 W

Chapter 2 Wiring and Protection Article 200 Use and Identification of Grounded Neutral Conductor Chapter 1 General...9

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

Running Magnet 2.0 Recessed High-tech LED lighting system for interior architecture

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

BLACK BODY DIMMING 800/1300/1500 LUMEN 6 LED NEW CONSTRUCTION/REMODEL

Reflectors are compatible with respective Marquise I series housings manufactured by Nora Lighting.

Circa Ambient Interior Luminaire

INSTALLATION MANUAL. Recessed In-Ceiling Motorized Projection Screen

Avenue B. Grid Mount (Regress Trim Shown) Flush Lens. Drywall Flange (Regress Trim Shown) Narrow 3" slot LED with frosted satin lens.

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

Reflectors are compatible with respective Marquise II series housings manufactured by Nora Lighting.

LED IMPORTANT SAFETY INSTRUCTIONS

Description. Material. LED Chip. Mounting. Max Length. Environment. Certifications. Warranty. Dimming

GEMINI HOUSING SPECIFICATIONS

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Avenue A. Grid Mount (Open Shown) Drywall Flange (Open Shown) louver lens mr16

Electric Range installation manual

n Ilation instructions Load Center Transfer TMOperator

seem 2 led features dimensional data Narrow extruded aluminum 2.5" aperture recessed slot LED.

Catalog # Project. Comments. Prepared by. L653 L =12'Nominal Actual length: 140-1/8" [3559mm] W=1 3/8" [3559mm] H =11/16" [17.5mm]

EMERY SKY SUSPENDED LED LUMINAIRE

RECESSED WALL WASH MOUNT

Electrical Applications. Metal Framing & Cable Tray Superstrut Metal Framing System. Column A. Design Data: Materials: Column B

JAZZ J400C (COLOR), J400AS (AUTO SYNC)

Section One: Install the Constant Current DMX Driver

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

DHFR Recessed Vertical Fluorescent Downlight General Remodel 4, 5, 6 Aperture

HALO H5RICAT. 5" RECESSED DOWNLIGHTING Incandescent

Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt. Owners Manual

Sunwize Power Ready Express Quick Start

Transcription:

INSTRUCTIONS LIGHTPLANE 1 RECESSED - LP1R Safety & Warnings! When installing or using this recessed fixture basic safety precautions should be followed: 1. Read ALL INSTRUCTIONS before installing 2. This fixture is intended for installation in accordance with the National Electric Code and Local and State Codes and must be installed by a licensed electrical contractor. 3. DO NOT INSTALL FIXTURE WITHOUT A MINIMUM 1/2 INCH CLEARANCE ALL AROUND THE FIXTURE. ENSURE CLEARANCE AT TOP OF CHANNEL IS 1 INCH. 4. THIS FIXTURE IS FOR IN NON INSULATED S ONLY. 5. To prevent electrical shock, turn off electricity at fuse box before installing the 6. Turn off power and allow fixture to cool down before adjusting position of lamp gimbals. 7. Use AWG#14 wire only for supply to the SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing.

INSTRUCTIONS LIGHTPLANE 1 RECESSED - LP1RT TRIM - GRID by driver specification) from the LED. Provide conduit, Pull String or provide other the REMOTE DRIVER. Secure REMOTE DRIVER to building structure with hardware as needed. (By Others). 3. If Joining multiple LED segments remove back cover and secure segments together using JOINING BAR set screws. Each segment requires a separate CORD and may require a separate REMOTE DRIVER. 2 SPACING 9/16 SUSPENDED GRID (SHOWN) 3 LPLR-1 (22 8 ) 8-32 ALLTHREAD/ LOCATION 4. should be installed to provide a 1in wide SURFACE OPENING for WIREBODY and LENS. Use appropriate support hardware as needed. (See Below) 5. Suitable SUPPORT RODS to building structure or appropriate brackets should be installed before installing The Suspended Ceiling must be independently supported from the fixture and spaced to fit the fixture width and length before installing the 6. While protecting finished parts and supporting the fixture, pull CORD(s) to the REMOTE DRIVER(s) and insert CORD through KNOCKOUT in the enclosure and connect to driver output. If connector is provided on the CORD then attach end of CORD to the connector. Secure excess CORD as needed. SCREWS SCREWS BUILDING STRUCTURE SUPPORT WIRE SUSPENDED COVER PLATE SUSPENDED BUILDING STRUCTURE 8-32 ALLTHREAD 7. Connect Building Power to the REMOTE DRIVER using U.L. approved wire connectors: connect the luminary neutral (white) to the supply neutral, connect the luminary line wire (black) to the supply line wire. Fasten ground wire(s) (Green) to ground wire. 2 2 LAY IN & SUPPORT WIRE 4 (WITH SLOTTED COVER) EXAMPLES 4 2 8-32 ALLTHREAD 2 8. Install WIREBODY into using S and secure with support hardware as needed using one of the suitable methods illustrated. 9. Install LENS(s) If needed. 10. Turn On Power

INSTRUCTIONS LIGHTPLANE 1 RECESSED - LP1RT TRIM - DRYWALL BUILDING POWER SURFACE OPENING REMOTE DRIVER the REMOTE DRIVER. Secure REMOTE DRIVER to building structure with brackets or blocking as needed (By Others). Provide a 1-1/16 in. wide SURFACE OPENING for WIREBODY and appropriate support for SPRING CLIPS as needed. (See Below) CORD WIREBODY LENS 2 1 3 6 " 1-1/16 Ceiling Cutout 3. If Joining multiple LED segments remove requires a separate CORD and may require a separate REMOTE DRIVER. 4. While protecting finished parts and supporting the fixture, pull CORD(s) to the REMOTE DRIVER(s) and insert CORD through KNOCKOUT in the enclosure and connect to driver output. If connector is provided on the CORD then attach end of CORD to the connector. Secure excess CORD as needed. SPRING CLIP 5. Connect Building Power to the REMOTE using supplied SPRING CLIPS. 7. Install LENS(s) 8. Turn On Power

INSTRUCTIONS LIGHTPLANE 1 RECESSED - LP1RMUD TRIMLESS - DRYWALL access to bring PLENUM CABLE from the EXTRUSION to the REMOTE DRIVER. Secure REMOTE DRIVER to building structure with brackets or blocking as needed (By Others). Provide a 1-7/16 in. wide SURFACE OPENING for WIREBODY and appropriate support for WIREBODY WING mounting. 3. If Joining multiple LED segments remove requires a separate PLENUM CABLE and may require a separate REMOTE DRIVER. 4. While protecting finished parts and supporting the fixture, pull PLENUM CABLE(s) to the REMOTE DRIVER(s) and insert PLENUM CABLE through KNOCKOUT in the enclosure and connect to driver output. If connector is provided on the PLENUM CABLE then attach end of PLENUM CABLE to the connector. Secure excess PLENUM CABLE as needed. 5. Connect Building Power to the REMOTE by securing WIREBODY to blocking using MOUNTING HARDWARE by others. SHEETROCK shall then be placed over WIREBODY WING. PLASTER will then be used to fill in remaining gaps around WIREBODY LENS opening. 7. Install LENS(s) 8. Turn On Power

INSTRUCTIONS LIGHTPLANE 1 RECESSED - LP1RWWT TRIM - WALLWASH REMOTE DRIVER BUILDING POWER WIREBODY the REMOTE DRIVER. Secure REMOTE DRIVER to building structure with brackets or blocking as needed (By Others). Provide a 1-9/16 in. wide SURFACE OPENING for WIREBODY and appropriate support for SPRING CLIPS as needed. (See Below) TOP COVER ACCESS SPRING CLIPS 3. If joining multiple LED segments remove requires a separate CORD and may require a separate REMOTE DRIVER. 4. Pull CORD(s) to the REMOTE DRIVER(s) and insert CORD through KNOCKOUT in the enclosure and connect to driver output while protecting finished parts and supporting the If connector is provided on the CORD then attach end of CORD to the connector. Secure excess CORD as needed. CORD 5. Connect Building Power to the the REMOTE using supplied SPRING CLIPS. DRYWALL 2 1 4 1 9 7. Turn Power ON 2 1 4