REPAIR PART INSTALLATION INSTRUCTIONS

Similar documents
ACCESSORY KIT INSTALLATION INSTRUCTIONS

FAST-STAT. Model 3000 Installation Instructions. Application. Troubleshooting not operating. Before Installing This Product. Sender Installation

E4FH, E5FH SERIES 12 SEER HEAT PUMP

B2HZ SERIES - 13 SEER SINGLE PACKAGED HEAT PUMPS (R-410A, STYLE A,B)

E1RA, E2RA SERIES - 10 SEER, 1PH & 3PH HEAT PUMP- OUTDOOR UNIT

DZ11TA Commercial. 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/ IEER /3.3 COP/R-410A

DZ11S Commercial & 10-Ton, Three-Phase

NL SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (R-410A, STYLE B)

ACCESSORY KIT INSTALLATION INSTRUCTIONS

wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS

Installation Instructions

INSTALLATION INSTRUCTION

REPLACEMENT PARTS MANUAL

ACCESSORY KIT INSTALLATION INSTRUCTIONS

DP14HM Commercial 3-5 TON THREE-PHASE PACKAGED HEAT PUMPS 14 SEER. Cooling Capacity: 34,400-58,000 BTU/h Heating Capacity: 33,200-57,000 BTU/h

ACCESSORY KIT INSTALLATION INSTRUCTIONS

LOW AMBIENT ACCESSORY INSTALLATION INSTRUCTION

DZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A

H*BA SERIES, 10 SEER, 1PH & 3PH AIR CONDITIONER- OUTDOOR UNIT

STELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES SEER. MODELS E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES

Parts List, Charging Chart, Wiring Diagrams

REPLACEMENT PARTS MANUAL

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: AHP18 THRU 60 AND SHP48 THRU 60 FEATURES

REPLACEMENT PARTS MANUAL

ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102

F2FP (G), F3FP (TG) SERIES FAN COIL UNIT

TECHNICAL GUIDE LISTED SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: THGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS - 3 PHASE)

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Models: S38H1 W38H1 S43H1 W43H1 S49H1 W49H1 S61H1 W61H1 S38H1D S43H1D S49H1D S61H1D

GPC13M R-410A, 13 SEER. Packaged Air Conditioner. 3, 4, & 5 Tons. Cooling Capacity: 36,000-56,000 BTU/h

REPLACEMENT PARTS MANUAL

MODEL SMZ-SW ZONE CONTROL SYSTEM

ZHA/ZHB SERIES WARNING

Installation Instructions

Contents. Control Panel. Control Panel. Blower Housing. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

INSTALLATION INSTRUCTIONS CMH-7A LOW AMBIENT CONTROL

ACCESSORY KIT INSTALLATION INSTRUCTIONS

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. General Notes. Contents. Important MODEL: WH381 WH431 WH491

Predator Model Number Nomenclature

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

LISTED TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

Parts List, Charging Chart, Wiring Diagram

PHE4 SERIES - 14 SEER SINGLE PACKAGED ELECTRIC HEAT PUMP (R-410A, STYLE A)

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

INSTALLATION INSTRUCTION

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

INSTALLATION INSTRUCTIONS CMH-21 Low Ambient 460V Fan Speed Control

REPLACEMENT PARTS MANUAL

Advance Information SPLIT SYSTEM HEAT PUMP 10 SEER. ERA 018 thru thru 5 NOMINAL TONS DESCRIPTION FEATURES

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h

Installation Instructions

Technical Service Bulletin

DP13CM. Packaged Air Conditioner 3, 4, & 5 Tons / 13 SEER. Cooling Capacity: 36,000-56,000 BTU/h

Control Solutions Biofloor

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

ACCESSORY KIT INSTALLATION INSTRUCTIONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Models: S38H1 W38H1 S43H1 W43H1 S49H1 W49H1 S61H1 W61H1. General Notes. Contents.

REPLACEMENT PARTS MANUAL

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Models: SH381 SH431 SH491. Contents. General Notes. Important

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL

1968 Chevrolet Corvette with & without Factory Air Chevrolet Corvette without Factory Air

Installation Instructions

TECHNICAL GUIDE LISTED

PREMIUM SERIES 22 SEER SINGLE SPLIT DUCTLESS, COOLING SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS)

TCA WARNING CAUTION. TCA 15 through 25 ton ROOFTOP UNITS. Service Literature

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard C**H Series 2 & 2½ Ton 2-Stage Wall Mount Heat Pumps

FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH

LUI / LUO. Condensing Units

Parts List, Charging Chart, Wiring Diagrams

TECHNICAL GUIDE MODELS: RHP13J30 THRU 60 (3 ) RHP SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS.

SSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON

DESCRIPTION FEATURES

Electric Rotary Knob BILLET CONTROLS INSTALLATION INSTRUCTIONS

Wiring Diagrams (Including Accessories) (50/60 Hz)

SPLIT SYSTEM HEAT PUMPS. ERA Series 10 SEER Single and Three Phase TECHNICAL SPECIFICATIONS

FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 2 2-1/2 Ton Wall Mount T Series Heat Pumps

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

POWER TRIM 5 E DUAL POWER TRIM CONTROL

SPLIT SYSTEM HEAT PUMP 12 SEER

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS)

TECHNICAL GUIDE MODELS: RHP14J18 THRU 60 RHP SERIES SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

Installation Instructions

LX SERIES 16 SEER SINGLE SPLIT DUCTLESS, HEAT PUMP SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS)

CHEV PICK-UP

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up

13PJA. Heat Pumps. Parts List 20-July-2015

ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split System Air Conditioners HB 180/240, HF -15,-20 Models Only

STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING

CHEV PICK-UP

Installation Instructions

REPLACEMENT PARTS MANUAL

an ISO 9001: 2008 Registered Company CHEVELLE OFF TEMPERATURE COLD DEFROSTER DE-ICE OFF

Transcription:

REPAIR PART INSTALLATION INSTRUTIONS ONTROL REPAIR KIT FOR (S1-37323870001) ODELS E*FH / E*EB / E*S 361816-UAI-A-0208 FIGURE 1: Demand Defrost ontrol odule GENERAL The YorkGuard VI Demand Defrost control is a replacement part for prior versions of the YorkGuard control (YorkGuard IV). Following the detailed instructions for modifications of both the indoor and outdoor units is critical. NOTE: For direct replacement of YorkGuard VI, replace the control only. Service replacement kit consists of: 1. YorkGuard VI Defrost ontrol and ounting Plate 2. ounting plates and hardware (10 - #6 screws) 3. 2-wire harnesses, terminals (1/4" and 3/16") 4. Wiring diagrams for both electric heat connections and fossil fuel connections. ONTROL ONFIGURATION FOR ALL APPLIATIONS Remove control from packaging and configure the control as follows: 1. Specify the desired Low Temperature ut Out (LTO) using the jumper on the control. 2. Specify the desired Balance Point (BP) using the jumper on the control. 3. Specify Defrost urve 3 using the jumper on the control. 4. Verify that the Y2 LOK jumper is in the OFF position. This jumper is not applicable to a single stage compressor system. 5. Specify if the Heat Pump is installed with a fossil fuel furnace using the FFUEL jumper. The jumper should be ON for a fossil fuel furnace installation and OFF for an air handler installation. 6. The Switch Point jumper is not applicable to a single stage compressor system. 7. Verify that the HOT HEAT PUP is in the OFF position. Unitary Products Group

E*FH, E*EB & E*S ONTROL REPLAEENT (65) (RS) (65) YORKGUARD IV ONTROL B O P R O 3 9 B DEF. RELAY 4 7 A YEL(HP) YEL(HP) (52) (RS) (52B) YEL RED(51) GRAY(54) YEL(HP) () (52A) (56) (57) YEL YEL(HP) () FIGURE 2: Wiring onnections for E*FH and E*EB 1 2 (RS) (RS) ONTATOR OUTDOOR UNIT ODIFIATIONS 1. Disconnect all high and 24V voltage power to the unit and the control circuit. 2. ark and disconnect all thermostat, sensor and low voltage control connections from the YorkGuard IV control. 3. Remove the two #10 screws holding the control and remove the control. 4. Using the two #10 screws removed in step 3, secure the mounting plate supplied in the kit in the same location as the control that was removed. 5. Using the 4 screws supplied in the kit, secure the York- Guard VI control and mounting plate to the previously installed mounting plate. The control should be oriented with the thermostat connections to the left side. 6. Remove the screws mounting the defrost relay and replace the screws in the two empty holes to seal the control box. NOTE: ove the relay to the side but do not disconnect. 7. Re-wire per Figure 2 for E*FH and E*EB. NOTE: All E*EB wires are number coded versus color coded. All E*EB wires are noted in [ ]. FAN (FAN) RV RVG LPS LPS L1 ODF H YORKGUARD VI ONTROL a. Remove wire nut holding Yellow (HP) [], Black (RS) [52B] and Blue wire. Terminate the black (RS) [52] wire with an insulated 1/4" terminal and plug into RVG terminal on control. b. Remove the Black (RS) [65A] wire from the defrost relay and plug into the control at RV terminal on control. c. Remove the two fan leads (Black) from the defrost relay and plug into the L1 & ODF terminals on the new control for the condenser fan. Power supply should be connected to L1. d. Remove the following wires from the defrost relay and dispose of the wires: (As shown in Figure 3) 1. Blue [52] @ B 3. Red [51] @ 7 2. Orange [65] @ 4 4. Gray [54] @ A e. Remove Yellow [57] wire from contactor and strip end with plug (previously connected to the control.) Wire nut to Yellow (HP) [] wire from (a) above. Plug into control at. f. Remove Yellow (HP) [] wire from contactor and plug into control at. g. Install the new Blue wire (from kit) from the common side of the contactor to on the new control by 1. h. Remove Brown [56] wire from contactor and install the new Brown wire (from kit) from the contactor to on the control. Note the connection at the control is with a 3/16" terminal. Strip terminal with insulated 1/4 terminal and connect to terminal on control. 8. Re-wire per Figure 3 for E*S. a. Remove the 65A (RS) and 52A wire from the defrost relay and plug into the control at RV and RVG. b. Remove the two fan leads (Black) from the defrost relay and plug into the L1 & ODF terminals on the new control for the condenser fan. Power supply should be connected to L1. c. Remove the following wires from the defrost relay and dispose of the wires: 1. 52 @ B 3. 51 @ 7 2. 65 @ 4 4. 54 @ A d. Remove 57 wire from contactor and strip end with plug (previously connected to the control.) Disconnect 52B @ Rev. Valve Sol, Strip and wire nut to 57. The wire length may need to be extended. e. Remove 57A (HP) wire from contactor and plug into control at. The wire length may need to be extended or a new wire fabricated. f. Install the new Blue wire (from kit) from the common side of the contactor to on the new control by 1. g. Remove 56 wire from contactor and install the new Brown wire (from kit) from the contactor to on the control. Note the connection at the control is with a 3/ 16 terminal. Strip and terminate with insulated 1/4 terminal. 2 Unitary Products Group

9. Rewire sensor leads as follows. 65 YORKGUARD IV ONTROL B O P R O 52 3 9 B DEF. RELAY 4 7 A 51 54 56 57 65A(RS) 52A(RS) RS 52B(HP) 57A(HP) FAN ONTATOR a. Liquid line sensor leads (blue) - cut and strip and reterminate with 1/4" terminals. onnect to the control at LL & LLG. b. Ambient sensor leads (white) - cut and strip and reterminate with one 1/4" and one 3/16" terminal. onnect to control at AB & ABG. c. Discharge sensor leads (red) - cut and strip and reterminate with 3/16" terminals. onnect to control at DIS & DISG. 10. Apply a new wiring diagram for either electric heat installations (278019) or fossil fuel installations (278020) supplied in the kit to the inside of the control box of the outdoor unit. Note: The wiring diagram notes colored wires. 11. Verify the settings for the balance point and low temperature cut-out. The settings are found at the top left of the control and are set using the supplied jumpers. ONTATOR 1 2 65A (RS) 52A (RS) (FAN) RV RVG LPS LPS L1 ODF H YORKGUARD VI ONTROL INDOOR UNIT ODIFIATIONS NOTE: Indoor transformer should be rated for a minimum of 40VA. Replace transformer if necessary. FOSSIL FUEL APPLIATION - The YorkGuard VI control does not require an add-on fossil fuel kit. Remove existing fossil fuel kit if present. An optional bonnet sensor may be used if desired. See OPERATION INSTRUTIONS - DEAND DEFROST ONTROL BOARD on upgnet.com for details of functionality with and without bonnet sensor installed. 52B(HP) 57A(HP) 57 FIGURE 3: Wiring onnections for E*S Unitary Products Group 3

PUR RED TO REV VALVE TO O.D. FAN OTOR TO HP SWITH 3 6 9 B 2R 1 4 7 A PUR J S 53 W 60 Y 66 X R B O URRENT YORKGUARD IV BOP R O OD LL DIS G 51 61 TB1 52 YEL PUR TO O.D. SENSOR RED YEL TO DISH SENSOR TO LIQ LINE SENSOR S1 1 PUR 2 3 RED 4 TO ELE HEAT SETION B O 5 2 SR 1 230V 208V 1T A B SE A B 5 4 2 1R 1 T2 PUR 1 L2 L1 FIGURE 4: B1PH ontrol Wiring (Before) 4 Unitary Products Group

B1PH ONTROL REPLAEENT YORKGUARD IV REOVAL Remove YorkGuard IV from B1PH units as follows: 1. Disconnect the unit power supply. ark and disconnect all thermostat, sensor, and low voltage wires at the YorkGuard IV control. 2. Remove the two #10 screws holding the old YorkGuard IV control and remove the control. 3. Remove the two screws mounting the defrost relay 2R and move the relay to the side but do not disconnect the wires. YORKGUARD VI INSTALLATION Use the two #10 screws removed in step 3 above, to attach the mounting plate to the control box. Install YorkGuard VI control and mounting plate oriented with the thermostat connections to the left, to the mounting plate with #6 screws supplied. RE-WIRING B1PH ONTROL BOX See Figure 4 (Before) and the enclosed wiring diagram 278191 to re-wire the B1PH control box, or follow the step by step procedure below: 1. Disconnect the black OD fan motor wire from relay 2R-3 and connect to YorkGuard VI - ODF. 2. Disconnect the black wire from relay 2R-9 and connect to the other terminal at YorkGuard VI - L1. 3. Disconnect the black wire from relay 2R-7 and connect to YorkGuard VI - RV. 4. Disconnect the orange wire from relay 2R-4 and TB1-51 and connect between TB1-52 and YorkGuard VI - RVG. 5. Remove relay 2R and discard the remaining attached wires and the relay. 6. Disconnect the two brown high pressure switch wires (one at TB1-51 and one at 1 coil) and connect them to York- Guard VI-. NOTE: There are several brown wires at TB1-51. The wire connected to the high pressure switch can be easily confused with the wire connected to the reversing valve. You may want to use an meter to check continuity through the high pressure switch to find the correct wire. 7. ut the purple and blue wires at the low voltage plug that was connected to the old YorkGuard IV. Terminate the cut end of the blue wire with a 1/4" push-on terminal and connect to YorkGuard VI -. Terminate the cut end of the purple wire with a 1/4" push-on terminal and connect to YorkGuard VI - by 1. 8. ove the brown circuit breaker (B) wire from TB1-52 to TB1-51. 9. ove the black transformer wire from TB1-51 to TB1-52. 10. ut the orange wire from TB1-51 to the low voltage plug at the plug and strip the end about 1/2". Terminate this wire and the red low voltage wire with one 1/4 push-on terminal and connect to YorkGuard VI - R terminal. 11. Terminate the remaining low voltage wires with 1/4 pushon terminals and connect to the YorkGuard VI low voltage terminals. 12. Remove and discard the low voltage plug and the wires still attached to it. 13. Rewire the sensor leads as follows: a. Liquid line sensor leads (blue) - cut at plug, strip end, and re-terminate with 1/4" terminals. onnect to the YorkGuard VI - LL & LLG. b. Ambient sensor leads (yellow) - cut at plug, strip end, and re-terminate with one 1/4" terminal and one 3/16" terminal. onnect to the YorkGuard VI - AB & ABG. c. Discharge sensor leads (red) - cut at plug, strip end, and re-terminate with 3/16" terminals. onnect to the YorkGuard VI - DIS & DISG. 14. Apply a new B1PH wiring diagram (278191) supplied with the kit to the inside of the control box cover. 15. Use the jumper pins supplied on the control to set the balance point (BAL PT) and low temperature cut-out (LTO) settings to the same settings that were on the control. Unitary Products Group 5

START-UP OPERATION 52 B 68 51 24V TRANSFORER YORK- GUARD IV 60 66 66A 60A D R P O B 56 54 52 55 63 51B 61A 51A 1 4 7 A 61 T2 2R 2TB 52 51 3 9 B to FAN 3B 52A 61B 52B 3B 52F 56A REV SOL HP 1. Reapply power to the unit and the control voltage circuit. 2. The LED on the defrost control will flash on and off when there is power to the control and it is working properly. 3. Verify unit operation. For more information on control operation, refer to OPER- ATION INSTRUTIONS - DEAND DEFROST ONTROL BOARD on upgnet.com. LINE 52 B 68 51 24V TRANSFORER HP 2TB 3B 51B 60A 61 51 52 52 55 52F 56A 56 61B REV SOL 52B 61A 3B (FAN) RV RVG LPS LPS L1 ODF H 1 2 R Y2 OUT W2 OUT LINE 66A W1 OUT FIGURE 5: Wiring onnections for B1PS 6 Unitary Products Group

TEPLATE UP FIGURE 6: ontrol ounting Template Unitary Products Group 7

NOTES Subject to change without notice. Printed in U.S.A. opyright by Unitary Products Group. 2008. All rights reserved. 361816-UAI-A-0208 Supersedes: 276251-UAI-A-0107 Unitary 5005 Norman Product York OK Group Drive 73069