TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

Similar documents
CEILING & INLINE/CABINET VENTILATORS

ceiling & inline/cabinet ventilators

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODEL FF50 CEILING FAN

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

High Capacity Ventilation

forward curved inline duct blowers

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

PERFORMANCE SPECIFICATIONS SINGLE-SPEED, 110 CFM VENTILATION FAN

AMCA Licensed Products

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

Need a. Bathroom Fan?

DIrect drive exhaust & supply panel fans

Twin City Fan & Blower

SQUARE INLINE CENTRIFUGAL FANS

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply)

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

MODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

CONSTRUCTION FEATURES AND OPTIONS

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

Industry best 5 year fan housing warranty, 1 year motor warranty

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP

Industry best 5 year fan housing warranty, 1 year motor warranty

FIXED PITCH PROPELLER FANS

Propeller Hooded Roof Fans

Filtered Kitchen Supply Packaged Ventilator

Direct Gas-Fired Heating

Ceiling and Inline Fans

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

TURNING AIR INTO SOLUTIONS. COMPACT PLENUM FANS ECLFN ECLQN

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

Defining Innovation. backward curved FANs

Multi-Port Centrifugal Fans for Round Duct

PREFABRICATED ROOF CURBS

Industry best 5 year fan housing warranty, 1 year motor warranty

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan PRESSURE BLOWERS MODEL PBW CATALOG 1260 APRIL 2015

TURNING AIR INTO SOLUTIONS. PROPELLER WALL FANS WPD WPB

Air Moving Solutions. MODULAR plenum fans

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

Model: G-143-VG. CAPS Z:\Carl\winjobs\Alley 111.gfcj Page 6 of 18

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

Inline Fans Options Featuring TD-MIXVENT/TD-SILENT

EcoWatt Products. Advancing Ventilation

Downblast Centrifugal Fans with ECM

Twin City Fan & Blower

K SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS

TURNING AIR INTO SOLUTIONS. UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS DCRU DCRUR DCRW DCRWR BCRU BCRUR BCRW BCRWR BCRUSH

Inline Fans Options Featuring TD-MIXVENT/TD-SILENT

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

TURNING AIR INTO SOLUTIONS. PRESSURE BLOWERS. Model PBW

Centrifugal Spun Aluminum Products

LINEA Low Discharge Roof Exhausters

CEILING VENTILATOR ACCESSORIES 6393 Powers Avenue Jacksonville, Florida P: / F:

Centrifugal Inline Fans Models SQ and BSQ Direct and Belt Drive

Tubular Centrifugal Fans

DOWNBLAST ROOF EXHAUSTERS

Twin City Fan & Blower

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan PROPELLER WALL FANS WPD WPB CATALOG 4820 MARCH 2017

& 12" 96" / TABD CATALOG

Practical examples of installation in the TD range

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted

Direct Drive Centrifugal Exhausters Low Profile Roof/Sidewall and Roof Downblast

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS

Square Inline Fans with Multi-Directional Discharge

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products

Low Silhouette Power Roof Ventilator Propeller

Roof Upblast and Sidewall Exhaust

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

VDBA INDOOR SINGLE & TWIN LINE DUCT BLOWERS

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS

CENTREX INLINER Centrifugal Inline Fans

CAST ALUMINUM PRESSURE BLOWERS

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS

Advancing Ventilation

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE

Transcription:

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS T-Series TL-Series CATALOG 4600 March 2018

CEILING & INLINE VENTILATORS Overview T I TL Twin City Fan & Blower s T-Series Ceiling and TL-Series Inline/Cabinet Ventilators are designed for commercial applications requiring quiet, continuous, reliable operation. Exhausters are constructed with a low profile grille and are easy to duct horizontally, vertically or inline, with many models offering round duct connectors as standard. T-Series Ventilators Typical Applications Include Bathroom Exhaust, Attic Ventilation, HVAC, Home Ventilation Configurations Ceiling or Wall Mount; Horizontal, Vertical or Inline Mount Wheel Type Centrifugal Blower Certifications AMCA Sound and Air, HVI and Energy Star, and UL/CUL 705 Listed for Electrical TL-Series Ventilators HVI-2100 Certified Ratings comply with new testing technologies and procedures prescribed by the Home Ventilating Institute, for offthe-shelf products, as they are available to consumers. Product performance is rated at 0.1 in. static pressure, based on tests conducted in a state-of-the-art test laboratory. Sones are a measure of humanly-perceived loudness, based on laboratory measurements. Twin City Fan & Blower certifies that the T080E, T110E, T080LP, T110 and T150LP are HVI and Energy Star certified. Twin City Fan & Blower certifies that the T Ceiling and TL Inline/Cabinet Ventilators shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air and sound performance for all Model T and TL fans shown with exception of the T080LP, T110 and T150LP. 2 TWIN CITY FAN - CATALOG 4600 All models FS10 For complete product performance, drawings and available accessories, download Fan Selector at tcf.com.

CEILING & INLINE VENTILATORS Overview T I TL Features Grille Conceals interior Low profile styling blends with any decor Blower Low RPM for quiet operation Resilient anti-vibration mounts Designed for continuous operation Dynamically-balanced, polymeric centrifugal blower wheel for quiet, efficient performance (T2000L and T3500EXL furnished with metal wheel) Permanently lubricated, thermally protected motor Plug-in motor rated at 120V AC, 60 Hz, single phase, ODP. T3500EXL motor is rated at 240V. For other 240V units contact factory Model T Airflow to 1,590 CFM Static pressure to 1" w.g. Model TL Airflow to 3,868 CFM Static pressure to 1" w.g. Bathroom Application, Model T WWW.TCF.COM 3

CEILING & INLINE VENTILATORS Commercial Fans T I TL Models T100-T300 & Models T100L-T300L Model T200 20 gauge galvanized steel housing 6" round duct connector sizes T100 and T150 8" round duct connector sizes T200, T250 and T300 Built-in backdraft damper 1 2" acoustic insulation inside (inline models do not include insulation) May be installed in ceiling or wall, horizontally, vertically or inline 8-position mounting brackets for easy installation and greater adaptability to various mounting requirements Ceiling mount UL listed for use over bathtubs and showers when connected to a GFCI-protected branch circuit Inline models have a removable panel to allow easy access to the motor without disturbing ductwork Single impact resistant centrifugal blower wheel White polymeric grille (Model T only), metal as an option Models T400-T700 & Models T400L-T700L Model T100L Model T400 Model T400L 4 TWIN CITY FAN - CATALOG 4600 20 gauge galvanized steel housing 41 2" x 181 2" duct connector with built-in automatic backdraft damper 1 2" acoustic insulation inside (inline models do not include insulation) May be installed in ceiling or wall, horizontally, vertically or inline Painted white enamel steel grille (Model T only) Two impact-resistant centrifugal blower wheels 8-position mounting brackets for easy installation and greater adaptability to various mounting requirements Inline models have a removable panel to allow easy access to the motor without disturbing ductwork

CEILING & INLINE VENTILATORS Commercial Fans T I TL Models T900-T1500 & T900L-T1500L 20 gauge galvanized steel housing 8" x 12" duct connector with built-in backdraft damper 1 2" acoustic insulation inside (inline models do not include insulation) May be installed in ceiling or wall, horizontally, vertically or inline 8-position mounting brackets for easy installation and greater adaptability to various mounting requirements Painted white enamel steel grille (Model T only) Single impact-resistant centrifugal blower wheel Inline models have a removable panel to allow easy access to the motor without disturbing ductwork Model T900-T1500 Models T2000L & T3500EXL 20 gauge galvanized steel May be installed in ceiling or wall 8-position mounting brackets for easy installation and greater adaptability to various mounting requirements Factory-shipped in straight-through discharge position may be converted to right angle discharge T2000L fits 73 4" x 333 4" ducts T3500EXL fits 93 4" x 413 8" ducts Designed for continuous operation Two metal centrifugal blower wheels Model T2000L (Shown With Optional Grill) WWW.TCF.COM 5

CEILING & INLINE VENTILATORS Bath Fans T I TL Model T050 Durable fan and blower assemblies encased in sturdy steel housings Permanently lubricated motors drive specially designed blowers, quietly delivering high exhaust performance Durable dampers prevent cold backdrafts with no metallic clatter Built-in mounting ears for quick, sturdy installation Polymeric duct connectors feature long, tapered sleeves for easier, positive ducting UL listed for use over bathtubs and showers when connected to a GFCI-protected branch circuit Plug-in, permanently lubricated motor Centrifugal blower wheel Torsion spring grille mounting no tools necessary Designer styled white polymeric grille blends well with any decor Metal grille kits available Model T080E Model T050 Compact, galvanized steel housing attaches easily to wall or ceiling joists Double strength mounting flanges with keyhole slots Removable wiring cover make connections away from tight corners No electrical knockout to remove Polymeric duct fitting with tapered sleeve for easy, positive duct connection Quiet polymeric damper prevents cold backdrafts with no metallic clatter Compact housing fits easily between wall studs Double strength steel mounting flanges with keyhole slots for fast, sturdy installation 3" round duct connector Model T080E & T110E 6" round duct connector Built-in backdraft damper Ceiling mount UL listed for use over bathtubs and showers when connected to GFCI-protected branch circuit HVI certified High tech multi-speed EC motor Telescoping mounting frame for quick and easy installation 6 TWIN CITY FAN - CATALOG 4600

CEILING & INLINE VENTILATORS Bath Fans T I TL Model T080LP 4" oval duct Built-in backdraft damper 4" height Ceiling mount UL listed for use over bathtubs and showers when connected to GFCI-protected branch circuit HVI certified Model T080LP Model T081 Rugged steel housing Impact-resistant centrifugal blower wheel and 4-pole motor for high capacity at low sound levels Sturdy key-holed mounting brackets for quick, accurate and sturdy installation Tapered, polymeric duct fitting for easy, positive duct connection and no metallic clatter 4" round duct connector Model T110 Model T081 4" oval duct Built-in backdraft damper Ceiling mount UL listed for use over bathtubs and showers when connected to GFCI-protected branch circuit HVI certified Models T150LP 6" oval duct Built-in backdraft damper 4" height Ceiling mount UL listed for use over bathtubs and showers when connected to GFCI-protected branch circuit HVI certified Model T110 Model T150LP WWW.TCF.COM 7

PRODUCT ACCESSORIES CEILING MOUNT INLINE ROOF CAP WALL CAP SPEED BACK- RAD- FLAT FAN METAL SLOPED CON- DRAFT IATION (ALUMINUM) VIBRATION INLINE STEEL W/ MODEL GRILLE ALUM. HANGERS ADAPTER TROL DAMPER DAMPER LOUVERS STEEL ALUM FLASHED CURB MTD. T050 97011308 636P 642 634M T080E RDFU 641 634P T080LP 636P 636AL 642 T081 RDM1 MMG 636P T100 RD1 MG1 634M 644 611 611CM 641 V104 961L T110 RDM1 MMG 636P 636AL 642 T110E RDFUWT 634M T150LP 57W 634P 641 STD T150 634M 961L T200 RD1 MG1 644 611 611CM T250 634P 643 981L T300 T400 TRAN- SITION- SQUARE TO ROUND TIMER 15- MINUTE 115/230V 60- MINUTE 115/230V SWITCH ON/OFF 115V 61W 59W 69W FAN/LIGHT CONTROL W/ OFF- DELAY V104 T500 RD2 437 441 982L 423 T700 STD 612 612CM 613 T900 RD3 983L T81212 T1500 72W T100L 634M 641 T150L T200L 644 611 611CM T250L 634P 643 T300L 57W 64W STD T400L 69W V104 61W 59W T500L 437 441 423 T700L 612 612CM 613 T900L T81212 T1500L 72W T2000L D100 G102 T3500EXL 75V D101 G103 = Not Available 64W Wall Caps Models 613, 641, 642, 643 Model 613 Aluminum natural finish Built-in backdraft damper and birdscreen For 12" round duct Model 641 Same as Model 613 except for 6" round duct Model 642 Same as Model 613 except for 3-4" round duct and no birdscreen Model 643 Same as Model 613 except for 8" round duct and no bird screen Model 441 Steel with aluminum louvers Collar with bird screen for attaching 10" round duct 8 TWIN CITY FAN - CATALOG 4600

PRODUCT ACCESSORIES Roof Caps Models 634M, 634P, 636P, 644 Model 634M For 3 1 4" x 10" or up to 6" round duct Built-in backdraft damper and birdscreen Steel housing, black electricallybonded epoxy finish Model 634P Same as Model 634M except for 8" round duct Model 644 Same as Model 634M except aluminum natural finish, and for up to 8" round duct Model 636P Same as Model 634M except for 3" or 4" round duct Models 611 & 612 Models 611CM & 612CM Model 611 For flat roof installation Aluminum natural finish For up to 8" round duct Birdscreen Model 612 For flat roof installation Aluminum natural finish For up to 12" round duct Birdscreen Model 611CM For curb mount installation Other features same as Model 611 Model 612CM For curb mount installation Other features same as Model 612 Model 437 Model 437 High-capacity design up to 1200 CFM Built-in bird screen Steel housing, black electricallybonded epoxy finish For up to 10" round duct Inline Adapters Model 961L Galvanized steel 6" round duct intake Mounting hard-ware included Model 981L Galvanized steel 8" round duct intake Mounting hard-ware included Model 982L Galvanized steel 4 1 2" x 18 1 2" duct intake Mounting hard-ware included Model 983L Galvanized steel 8" x 12" duct intake Mounting hard-ware included WWW.TCF.COM 9

PRODUCT ACCESSORIES Controls Model 57W Speed Control Model 57W 120V, 3 amps Fits single-gang box Positive on/off action dial for variable selection of air speeds and sound levels Model 80L Speed Control Unit Mount Model 80L Models 72W, 75V Speed Control Model 69W On/Off Switch 120V, 6 amps Model 72W 240V, 6 amps Model 75V Other features same as 57W Model 72W 75V Model 59W Time Control 120V, 20 amp or 240V, 10 amp capacity Operates continuously or for any set period up to 60 minutes 120VAC, 15 amp Fits single gang box Model 69W Model 61W Time Control Model 59W 61W Operates for any set period up to 15 minutes (no continuous on position) Other features same as 59W Model 64W Radiation Dampers Model RD1 Model 64W Fan/Light Control with Off-Delay Fan and light operate together when control is turned on. Fan continues to operate for a useradjustable time period 5-60 minutes after light is turned off Fits single-gang box Center position bypasses timer and turns fan and light off immediately 120V, 4 amps (fan), 4 amps (light) Requires hot and neutral wires in the switch box Duct Transitions Models RD1, RDM1, RD2, RD3 Models 423, T81212 UL rated for use in 1, 2 or 3 hour fire-rated ceilings Galvanized steel frame High temperature, non-asbestos, reinforced fiber thermal fabric 212 F fusible link Stainless steel negator-type closure spring Galvanized steel Allows for quick transition to easyto-obtain-and-install round ducting Model 423 41 2" x 181 2" to 10" round Model T81212 8" x 12" to 12" round Model RDM1 Damper Kits Metal Grille Kit Model MG1, MMG, 97011308, G102, G103 White enamel painted steel 10 120V, 3 amps Mounts inside fan for room balancing without risk of tampering, access through grille (T) or access panel (TL) Vibration Dampening Hangers Models D100, 101 Model V104 Not illustrated Twin damper flaps and mounting hardware Foam cushion and magnetic catch assure quiet, effective backdraft prevention Not illustrated Heavy gauge steel construction with vibration dampening cushion Maximum load 75 lbs. (each) For 3 8" diameter threaded rod (provided by installer) TWIN CITY FAN - CATALOG 4600

DIMENSIONAL DATA Models T080E & T110E Model T050 4 71 4 71 2 6 35 8 75 8 101 2 9 3 113 8 SPANS 14 TO 24 ON-CENTER FRAMING 91 4 8 13 133 4 Model T080LP Model T110 Model T081 3 OVAL DUCT CONNECTOR FOR 4" ROUND DUCT 41 4 4 4 13 53 4 53 4 4 101 2 41 4 91 4 10 111 2 12 91 4 10 113 8 111 2 12 14 WWW.TCF.COM 11

DIMENSIONAL DATA Models T100-T300 & T100L-T300L* 121 4 Model T150LP Models T400-T700 & T400L-T700L* 121 4 121 4 211 2 75 8 113 4 113 4 113 8 101 2 14 231 4 14 14 133 4 13 *Panel replaces grille on inline models. *Panel replaces grille on inline models. Models T900 & T1500 and T900L & T1500L* Model T2000L Model T3500L 163 4 145 8 22 453 4 38 18 333 4 413 8 163 4 145 8 93 4 73 4 18 431 2 353 4 12 8 3 237 8 197 8 *Panel replaces grille on inline models. 12 TWIN CITY FAN - CATALOG 4600 141 2

Ceiling Mount PERFORMANCE DATA Ceiling Models Horizontally Mounted MODEL NO. PART NO. RPM AMPS @ 60HZ WATTS T050 59120001 1870-48 T080E 59120011 935 0.3 6.1 T080LP* 59120004 743 0.3 25 T081 59120003 840 0.3 26.9 T100 59120101 640 1.1 87 T110E 59120012 940 0.3 8.4 T110* 59120111 1137 0.4 47.3 T150LP* 59120005 708 0.5 42.8 T150 59120102 710 1.3 100 T200 59120103 740 1.8 127 T250 59120104 830 2.1 166 T300 5912015 905 2.6 212 T400 59120106 735 1.4 146 T500 59120107 810 2.2 232 T700 59120108 960 2.9 313 T900 59120109 650 3 306 T1500 59120110 955 5 468 * Units are HVI certified, but do not hold AMCA certification. CFM/SONES STATIC PRESSURES (IN. W.G.) 0" 1/10" 1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1" 52 49 47 42 29 3.9 4.3 4.4 4.6 5.5 80 80 80 78 66 38 <0.3 <0.3 0.6 1.4 2.2 3.0 91 80 76 61 49 35 17-1.0 - - - - - 87 76 72 56 38 1.0 1.5 1.5 2.5 3.0 136 115 109 93 80 65 44 12 0.5 0.8 0.9 1.3 1.8 2.3 3.0 3.2 110 110 109 100 62 28 <0.3 <0.3 1.4 2.3 3.0 3.6 122 110 109 102 75 31-3.0 - - - - 170 150 145 120 99 74 43-1.4 - - - - - 181 161 157 141 132 124 114 94 62 1.3 1.4 1.5 2.2 2.6 3.1 3.6 4.1 4.6 231 214 210 196 186 177 165 144 113 51 1.6 1.8 1.7 2.3 2.9 3.5 4.1 4.9 5.3 5.3 272 261 259 250 242 233 218 201 165 99 2.1 2.3 2.2 2.9 3.3 3.9 4.4 4.8 5.5 5.8 312 309 308 303 296 287 273 254 219 125 2.8 2.9 2.9 3.3 3.5 3.9 4.3 4.7 5.1 5.6 480 442 434 388 344 299 229 182 114 33 2.0 2.4 2.3 2.8 3.3 3.8 4.5 4.8 5.4 5.6 538 520 514 491 463 434 389 339 282 186 3.0 3.1 3.3 3.6 4.0 4.4 5.0 5.7 6.2 6.7 722 704 701 667 640 607 571 534 453 333 4.5 4.6 4.7 4.8 5.0 5.2 5.6 6.2 7.1 7.2 918 905 901 877 842 793 725 636 536 390 3.8 4.0 4.1 4.0 4.2 4.3 4.4 4.9 4.5 5.3 1578 1526 1513 1438 1371 1285 1198 1103 1000 816 8.6 8.4 8.4 8.1 7.5 7.0 6.7 6.2 5.8 5.8 Ceiling Models Vertically Mounted AMPS CFM/SONES MODEL PART RPM @ WATTS STATIC PRESSURES (IN. W.G.) NO. NO. 60 HZ 0" 1/10" 1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1" T100 59120101 650 1.1 87 138 117 112 94 80 67 46 13 0.7 0.9 1.0 1.3 1.8 2.2 2.8 3.0 T150 59120102 750 1.3 100 179 163 160 149 142 133 122 105 73 23 1.4 1.6 1.6 2.0 2.5 3.0 3.3 3.6 3.9 4.2 T200 59120103 760 1.8 127 224 210 207 197 187 179 167 144 99 41 1.5 1.8 2.0 2.3 2.7 3.4 4.0 4.5 5.1 5.2 T250 59120104 860 2.1 166 269 261 259 253 248 239 224 203 171 101 2.3 2.6 2.7 3.0 3.3 3.7 4.2 4.7 5.4 5.6 T300 59120105 940 2.6 212 319 314 313 306 299 288 274 251 219 120 2.6 2.9 3.0 3.4 3.6 3.9 4.4 4.7 5.0 5.5 T400 59120106 755 1.4 146 467 428 416 378 335 291 237 170 85 8 2.3 2.6 2.6 3.0 3.5 4.0 5.1 5.5 5.7 5.9 T500 59120107 865 2.2 232 539 517 512 481 451 418 367 319 247 137 2.9 3.1 3.2 3.4 3.8 4.2 4.8 5.9 6.3 6.4 T700 59120108 985 2.9 313 708 691 687 658 628 597 560 515 444 312 5.2 5.0 5.0 5.7 5.8 6.1 6.4 7.4 7.1 7.6 T900 59120109 650 3.0 306 909 892 885 850 807 756 695 568 440 282 3.8 3.4 3.4 3.5 3.6 3.7 3.9 4.2 4.3 4.4 T1500 59120110 955 5.0 468 1590 1519 1502 1423 1340 1259 1176 1069 954 689 8.5 8.4 8.4 8.1 7.9 7.5 7.2 7.1 6.9 6.5 Performance ratings include the effects of an inlet grille and backdraft damper. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type B: Free inlet hemispherical sone levels. Performance certified is for Installation Type B: Free inlet, ducted outlet. WWW.TCF.COM 13

PERFORMANCE DATA Inline Inline Models Straight-Through AMPS CFM/SONES MODEL PART RPM @ WATTS STATIC PRESSURES (IN. W.G.) NO. NO. 60 HZ 0" 1/10" 1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1" T100L 59120301 760 1.1 87 121 108 106 97 93 86 70 44 17 0.5 0.7 0.7 1.1 1.4 1.8 2.1 2.4 2.6 T150L 59120302 920 1.3 100 153 148 147 140 134 125 111 91 54 18 0.9 1.0 1.1 1.4 1.6 1.9 2.1 2.2 2.4 2.6 T200L 59120303 865 1.8 127 205 196 195 190 185 175 158 135 96 47 1.7 1.9 1.9 2.1 2.3 2.4 3.0 3.3 3.4 3.4 T250L 59120304 1005 2.1 166 248 245 245 241 235 224 208 183 141 84 2.0 2.3 2.3 2.6 2.8 3.2 3.4 3.6 3.9 3.8 T300L 59120305 1145 2.6 212 300 294 293 285 274 259 243 214 168 113 2.9 3.0 3.1 3.3 3.4 3.5 3.6 3.7 4.0 3.9 T400L 59120306 775 1.4 146 450 415 406 360 313 271 223 167 90 6.0 1.4 1.6 1.6 1.9 2.2 2.6 2.9 3.4 3.6 3.9 T500L 59120307 890 2.2 232 546 526 519 496 472 447 407 364 306 232 2.4 2.4 3.4 3.7 3.9 3.8 3.9 4.0 4.3 4.3 T700L 59120308 1090 2.9 313 704 686 681 656 631 604 575 533 480 412 3.6 3.8 3.7 3.9 4.0 4.2 4.3 4.4 4.7 5.0 T900L 59120309 810 3.0 306 930 902 894 853 807 754 685 587 442 300 3.7 3.8 3.8 3.8 3.7 3.8 3.9 4.0 4.0 4.1 T1500L 59120310 1055 5.0 468 1275 1228 1214 1152 1092 1029 958 871 764 631 6.8 6.8 6.7 6.5 6.3 6.0 6.0 6.0 6.0 6.1 T2000L 59120311 965 5.8 590 1891 1803 1791 1657 1508 1347 1165 808 284 10.3 9.8 9.4 9.0 8.6 9.1 8.9 7.0 6.7 T3500EXL 59120701 3605 3498 3452 3278 3073 2893 2679 2429 2093 1693 1105 5.4 1204 15.3 14.8 14.5 14.1 13.1 12.8 12.1 11.8 11.9 10.8 Inline Models Right Angle AMPS CFM/SONES MODEL PART RPM @ WATTS STATIC PRESSURES (IN. W.G.) NO. NO. 60 HZ 0" 1/10" 1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1" T100L 59120301 780 1.1 87 109 98 96 88 82 78 67 48 16 0.5 0.8 0.8 1.2 1.6 2.0 2.3 2.5 2.8 T150L 59120302 950 1.3 100 144 138 137 131 123 114 102 83 54 17 1.2 1.4 1.4 1.6 1.9 2.1 2.4 2.5 2.7 2.9 T200L 59120303 930 1.8 127 183 177 176 170 163 152 137 121 96 51 1.6 1.6 1.6 1.9 2.3 2.7 2.9 3.1 3.4 3.6 T250L 59120304 1115 2.1 166 229 224 222 214 204 193 177 157 132 95 2.4 2.5 2.6 2.8 3.0 3.2 3.4 3.7 3.8 3.8 T300L 59120305 1285 2.6 212 270 261 259 248 234 220 200 174 146 104 3.7 3.7 3.7 3.7 3.9 3.9 4.0 4.2 4.4 4.0 T400L 59120306 875 1.4 146 442 415 408 372 336 296 239 193 111 28 1.6 1.7 1.7 2.0 2.4 2.6 3.1 3.4 3.9 4.1 T500L 59120307 990 2.2 232 528 516 513 494 470 446 415 389 334 247 2.9 3.8 3.4 3.7 3.5 3.6 3.9 4.0 4.2 4.4 T700L 59120308 1205 2.9 313 680 667 663 644 621 594 557 513 440 342 5.0 5.0 5.0 5.3 5.2 5.1 5.3 5.5 5.4 5.5 T900L 59120309 755 3.0 306 795 778 772 743 709 668 613 527 432 291 4.3 4.5 4.4 4.6 4.4 4.2 4.1 4.3 4.2 4.3 T1500L 59120310 1020 5.0 468 1160 1117 1106 1051 998 928 856 769 657 499 7.9 7.8 7.9 7.4 7.1 6.8 6.3 5.9 5.4 5.4 T2000L 59120311 1020 5.8 635 2070 1931 1898 1769 1609 1424 1314 795 288 11.1 10.3 10.1 9.7 9.4 9.2 8.5 7.0 6.7 T3500EXL 59120701 1110 5.4 1205 3868 3714 3696 3537 3356 3168 2951 2671 2384 2005 14.6 14.2 14.2 13.3 12.8 12.5 11.6 11.4 11.4 13.4 T100L through T1500L Performance ratings include the effects of a backdraft damper. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type D: Ducted inlet hemispherical sone levels. Ratings do not include the effect of duct end correction. Performance ratings include the effects of 18 feet of round inlet duct and, if needed, a rectangular-to-round duct transition in the airstream. Performance certified is for Installation Type D: Ducted inlet, ducted outlet. T2000L and T3500EXL Performance ratings do not include the effects of appurtenances (accessories). Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type D: Ducted inlet hemispherical sone levels. Ratings do not include the effect of duct end correction. Performance certified is for Installation Type D: Ducted inlet, ducted outlet. 14 TWIN CITY FAN - CATALOG 4600

PERFORMANCE CURVES Ceiling Mount Model T050 Model T080E 0.35 0.25 0.15 0.05 0 20 40 60 80 100 0.0 Precise airflow rate adjustability allows fan to produce any CFM shown within this shaded area. 0 10 20 30 40 50 60 70 80 90 Model T080LP Model T081 Model AE80 0.0 0 10 20 30 40 50 60 70 80 90 100 0.0 0 10 20 30 40 50 60 70 80 90 T100, T150 Series Model T110 1.00 0.90 T100 Series T150 Series 0 20 40 60 80 100 120 140 160 180 200 0.0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Notes: Performance certified is for Installation Type D: Ducted inlet, ducted outlet. Performance ratings include the effects of a backdraft damper. WWW.TCF.COM 15

PERFORMANCE CURVES Ceiling Mount Model T110E Model T150LP Precise airflow rate adjustability allows fan to produce any CFM shown within this shaded area. 0 10 20 30 40 50 60 70 80 90 100 110 120 0 20 40 60 80 100 120 140 160 180 T200, T250, T300 Series T400, T600, T700 Series T900, T1500 Series 1.00 1.00 1.00 0.90 0.90 0.90 T200 Series T250 Series T300 Series 0 40 80 120 160 200 240 280 320 T400 Series T500 Series T700 Series 0 80 160 240 320 400 480 560 640 720 T900 Series T1500 Series 0 200 400 600 800 1000 1200 1400 1600 Notes: Performance certified is for Installation Type D: Ducted inlet, ducted outlet. Performance ratings include the effects of a backdraft damper. 16 TWIN CITY FAN - CATALOG 4600

Inline PERFORMANCE CURVES T100L, T150L Series T200L, T250L, T300L Series 1.00 0.90 T100L Series T150L Series 1.00 0.90 T200L T250L T300L 0 20 40 60 80 100 120 140 160 180 200 0 40 80 120 160 200 240 280 320 T400L, T500L, T700L Series T900L, T1500L 1.00 1.00 0.90 0.90 T400L 0 80 160 240 320 400 480 560 640 720 T500L T700L T900L Series T1500L Series 0 200 400 600 800 1000 1200 1400 T2000L, T3500EXL 1.00 0.90 T3500EXL T2000L 0 600 1200 1800 2400 3000 3600 Notes: Performance certified is for Installation Type D: Ducted inlet, ducted outlet. Performance ratings include the effects of a backdraft damper. WWW.TCF.COM 17

TYPICAL SPECIFICATIONS Model T Models T050 and T081 T-Series Ventilators shall be Model T050 or T081, as manufactured by Twin City Fan & Blower, Minneapolis, Minnesota. PERFORMANCE Air delivery shall be no less and sound level no greater than listed. Fans shall bear the AMCA ratings seal for sound and air performance. Units shall be UL listed for use over bathtubs and showers with GFCI branch wiring. HOUSING Units shall have steel housing and shall be ducted to a roof or wall cap. DAMPER A backdraft damper shall be located within the duct connector. MOTOR AND WHEEL ASSEMBLY Motor assembly shall have a centrifugal blower wheel, be removable and permanently lubricated. RPM not to exceed number listed for each model. Models T080E and T110E T-Series Ventilators shall be Model T080E or T110E, as manufactured by Twin City Fan & Blower, Minneapolis, Minnesota. PERFORMANCE Air delivery shall be no less and sound level no greater than listed. Fans shall bear the AMCA ratings seal for sound and air performance. Units shall be UL listed for use over bathtubs and showers with GFCI branch wiring. HOUSING Units shall have steel housing and shall be ducted to a roof or wall cap. DAMPER A backdraft damper shall be located within the duct connector. MOTOR AND WHEEL ASSEMBLY Motor assembly shall have a centrifugal blower wheel, be removable and permanently lubricated. RPM not to exceed number listed for each model. The motor will be an electrically commutated motor. Models T080LP, T110 and T150LP T-Series Ventilators shall be Model T080LP, T110 or T150LP, as manufactured by Twin City Fan & Blower, Minneapolis, Minnesota. PERFORMANCE Air delivery shall be no less and sound level no greater than listed. Units shall be UL listed for use over bathtubs and showers with GFCI branch wiring. HOUSING Units shall have steel housing and shall be ducted to a roof or wall cap. DAMPER A backdraft damper shall be located within the duct connector. MOTOR AND WHEEL ASSEMBLY Motor assembly shall have a centrifugal blower wheel, be removable and permanently lubricated. RPM not to exceed number listed for each model. Models T100, T150, T200, T250, T300, T400, T500, T700, T900 and T1500 T-Series Ventilators shall be of the centrifugal direct drive type, Model T100, T150, T200, T250, T300, T400, T500, T700, T900, T1500, as manufactured by Twin City Fan & Blower, Minneapolis, Minnesota. PERFORMANCE Air delivery shall be no less and sound levels no greater than listed. Fans shall bear the AMCA ratings seal for sound and air performance. Fans and motors shall carry the UL and/or cul listed. HOUSING Units shall have a galvanized steel housing insulated with at least 1 2" of acoustic insulation. Housing shall have adjustable mounting brackets. DAMPER A backdraft damper shall be located within the duct connector. Duct connector, blower assembly and wiring plate shall be adjustable for either horizontal or vertical installation. MOTOR AND WHEEL ASSEMBLY The blower unit shall be removable from the housing and shall have a polymeric, balanced centrifugal-type blower wheel. Motor shall be permanently lubricated and mounted with resilient antivibration mounts. RPM not to exceed number listed for each model. 18 TWIN CITY FAN - CATALOG 4600

TYPICAL SPECIFICATIONS Model TL Models T100L, T200L, T250L, T300L, T400L, T500L, T700L, T900L and T1500L TL-Series Ventilators shall be of the centrifugal direct drive type, Model T100L, T200L, T250L, T300L, T400L, T500L, T700L, T900L and T1500L, as manufactured by Twin City Fan & Blower, Minneapolis, Minnesota. PERFORMANCE Air delivery shall be no less and sound levels no greater than listed for each model. Fans shall bear the AMCA ratings seal for sound and air performance. Units shall be UL and cul listed. HOUSING Ventilators shall have galvanized steel housings with adjustable housing mounting brackets. Models T100L, T200L, T250L, T300L, T400L, T500L, T700L, T900L and T1500L shall have a removable panel to allow access to the motor without disturbing ductwork. MOTOR AND WHEEL ASSEMBLY The blower unit shall be removable from the housing. Models T100L, T200L, T250L, T300L, T400L, T500L, T700L, T900L and T1500L shall have a polymeric, dynamically balanced centrifugal type blower wheel. Motors shall be permanently lubricated and mounted with resilient anti-vibration mounts. RPM not to exceed number listed for each model. DAMPER On models T100L, T200L, T250L, T300L, T400L, T500L, T700L, T900L and T1500L, backdraft damper shall be located within the exhaust side duct connector. The exhaust side duct connector, blower assembly and wiring plate shall be adjustable for either horizontal or vertical installation. Models T2000L and T3500EXL TL-Series Ventilators shall be of the centrifugal direct drive type, Model T2000L and T3500EXL, as manufactured by Twin City Fan & Blower, Minneapolis, Minnesota. PERFORMANCE Air delivery shall be no less and sound levels no greater than listed for each model. Fans shall bear the AMCA ratings seal for sound and air performance. Units shall be UL and cul listed. HOUSING Ventilators shall have galvanized steel housings with adjustable housing mounting brackets. On models T2000L and T3500EXL, the duct connector, blower assembly and wiring plate shall be adjustable for either horizontal or vertical installation. MOTOR AND WHEEL ASSEMBLY The blower unit shall be removable from the housing. Models T2000L and T3500EXL shall have a metal, centrifugal-type blower wheel. Motors shall be permanently lubricated and mounted with resilient anti-vibration mounts. RPM not to exceed number listed for each model. WWW.TCF.COM 19

INDUSTRIAL & COMMERCIAL FANS Centrifugal Fans Utility Sets Plenum & Plug Fans Inline Centrifugal Fans Mixed Flow Fans Tubeaxial & Vaneaxial Fans Propeller Wall Fans Propeller Roof Ventilators Centrifugal Roof & Wall Exhausters Ceiling Ventilators Gravity Ventilators Duct Blowers Radial Bladed Fans Radial Tip Fans High Efficiency Industrial Fans Pressure Blowers Laboratory Exhaust Fans Filtered Supply Fans Mancoolers Fiberglass Fans Custom Fans Twin City Fan Companies, Ltd. A Twin City Fan Company TWIN CITY FAN & BLOWER WWW.TCF.COM 5959 Trenton Lane N Minneapolis, MN 55442 Phone: 763-551-7600 Fax: 763-551-7601 2018 Twin City Fan Companies, Ltd., Minneapolis, MN. All rights reserved. Catalog illustrations cover the general appearance of Twin City Fan & Blower products at the time of publication and we reserve the right to make changes in design and construction at any time without notice.