CYCLOPS Z Purge Indicator

Similar documents
CYCLOPS Z Purge Indicator

CYCLOPS Y Purge Indicator

CYCLOPS X Purge Controller XP Version

CYCLOPS X Purge Controller SM Version

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Type Z & Ex pz purge and pressurization system

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

PANEL MOUNT EXPLOSION PROTECTED AIR CONDITIONERS

Hazardous Location Enclosures INDEX. Hazardous Location Enclosures HAZ-2

Flow Computer Installation

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

Maxum II Modular Oven Automatic Purge Control Unit Product Update PU-002

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter. Min.

APPROVALS:

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Series 3730 Electropneumatic Positioner Type

APG. Explosion Proof and Non-Incendive Magnetostrictive Level Sensors Series: MPX. Features

Protection When Safety Matters Most

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Fisher i2p 100 Electro Pneumatic Transducer

FM Approved Remote Kit Assembly (Part No ) Standard Remote Kit Assembly (Part No ) G2 SERIES G2 Industrial METER MODULES

Flash Point Process Analyzer

CC3060 TYPE 12 COMPACT CABINET COOLER AIR-TO-WATER FLUSH-MOUNT MODEL

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

Ar-Mite TM Low Flow Armored Flowmeter

SafeSite LED Based Signaling for Hazardous Locations

Integrated Control modules

Quartz. Save Space with Low Profile Design

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

SKINNER Intrinsically Safe Series Four-Way

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 120

PISTON STYLE GAUGE. Mid-West Instrument

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Maxum II Modular Oven Automatic Purge Control Unit Product Update PU-002

SERVOMEX 335A2014 PURGE ASSY Operator Manual

Hazardous Locations CHAPTER13. Hazardous Location

Control Device System NEC Series ConSig 8040

Terminal Boxes Series 8125

Linear Valve Electric Actuator

GTV Series High Pressure Control Valves

Compact Electric Actuated Ball Valves PVC Body, Teflon/EPDM Seals 1/2 to 1 inch Pipe

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

Valve Position Monitors

SM-1000 SERIES ROTARY ACTUATORS

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Model 116 DPI Switch Installation and Operating Instructions

Safety Standards. Model Number:

SynergEX Panelboards for Hazardous Locations

Terminal Boxes Series 8125

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

AT100 Magnetostrictive Level Transmitter. High accuracy magnetostrictive liquid level transmitter K-TEK Products

List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

DIESEL Engine Fire Pump Controllers Features

Point level measurement Capacitance switches

Model VC volt to 12 volt DC to DC Converter. Table of Contents. Introduction. 2. Specifications.. 2. Operation... 2

High Pressure Solenoid Valves

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

Dimensions WxHxD [mm] Weight [kg]

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

SafeSite LED Based Signaling for Hazardous Locations

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

Series 1. Series 1 Pressure Switch. Pressure Switches Inc. Quality Pressure Solutions. Pressure Switches 1 G 10 N Key Features.

DIFFERENTIAL PRESSURE BATTERY CHARGERS

AT30 SERIES BATTERY CHARGER

VALVITALIA VALVE OPERATORS

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Integrated Control modules

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Oil & Gas Lubrication Systems

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Accord DS/DM Series UltraSwitch Switch box

Limit Switch Type 4747

Input Voltage: AC: VAC HC: VAC (50/60Hz) Electrical Ratings: WIDE FROSTED MODEL

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

Smart Pressure Transmitter

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

Transcription:

Low cost Simple to install & use Highly reliable & maintenance free Enclosure vent is part of casing Local & remote status indicator Casing available in anodized aluminum & 316 stainless steel 12 or 24 VDC & 115 or 230 VAC All in One Unit OVERVIEW: To prevent the possibility of fire or explosion inside the enclosures of energized electrical equipment, a protective gas supply is used to dilute potentially flammable vapors to an acceptable level, creating a safe area for the devices within the enclosure. Positive pressure prevents the ingress of flammable vapors in the surrounding atmosphere from entering into the enclosure as long as positive pressure is maintained. After the enclosure is purged, power may be manually applied to the protected electrical equipment. The Purge Solutions CYCLOPS provides objective evidence of positive enclosure pressure with both a visible indicator and supplied standard, a drycontact output for remote status monitoring. The enclosure purge vent is an integrated part of the CYCLOPS s casing, which mounts directly to the enclosure being purged. No additional holes, sheet metal, or plumbing is required.

FEATURES: The CYCLOPS mounts directly to purged enclosure. No additional sheet metal enclosures or plumbing is required. (Refer to Figures 1, 2, 3, & 4) Enclosure purge vent is an integrated part of the CYCLOPS casing. No additional holes or plumbing is required in purged enclosure. (Refer to Figure 4) Dry contact output for remote monitoring is supplied as standard. Contact open on alarm (Standard). Contact closed on alarm (Optional). Order optional contact closed on alarm by adding an X at end of Purge Solutions model number. (Refer to Figure 4) Rugged, visual green LED indicator. Green LED on; enclosure purge pressure at or above required pressure. Green LED off, enclosure purge pressure below required pressure. The CYCLOPS is certified to ATEX, CSA, IECEx, NEC, NFPA, UL and CE Marked for installation and use in Division 2 and Zone 2 hazardous areas. Figure 1 Figure 2 Figure 3 Figure 4

OPTIONS & ACCESSORIES AVAILABLE: Purge Indicator Casing: Anodized aluminum (standard) 316 stainless steel (optional). Input Voltages Available: Either 12 VDC, 24 VDC, 115 VAC, or 230 VAC. Purge Solutions Available Models: 1. Type : 12 VDC, Anodized aluminum, Gas hazardous area installations: Purge Solutions model number PSCZ-1A 2. Type : 12 VDC, 316 stainless steel, Gas hazardous area installations: Purge Solutions model number PSCZ-1S 3. Type : 24 VDC, Anodized aluminum, Gas hazardous area installations: Purge Solutions model number PSCZ-2A 4. Type : 24 VDC, 316 stainless steel, Gas hazardous area installations: Purge Solutions model number PSCZ-2S 5. Type : 115 VAC, Anodized aluminum, Gas hazardous area installations: Purge Solutions model number PSCZ-3A 6. Type : 115 VAC, 316 stainless steel, Gas hazardous area installations: Purge Solutions model number PSCZ-3S 7. Type : 230 VAC, Anodized aluminum, Gas hazardous area installations: Purge Solutions model number PSCZ-4A 8. Type : 230 VAC, 316 stainless steel, Gas hazardous area installations: Purge Solutions model number PSCZ-4S 9. Type : 12 VDC, Anodized aluminum, Dust hazardous area installations: Purge Solutions model number PSCZ-1AD 10. Type : 12 VDC, 316 stainless steel, Dust hazardous area installations: Purge Solutions model number PSCZ-1SD 11. Type : 24 VDC, Anodized aluminum, Dust hazardous area installations: Purge Solutions model number PSCZ-2D 12. Type : 24 VDC, 316 stainless steel, Dust hazardous area installations: Purge Solutions model number PSCZ-2SD 13. Type : 115 VAC, Anodized aluminum, Dust hazardous area installations: Purge Solutions model number PSCZ-3AD 14. Type : 115 VAC, 316 stainless steel, Dust hazardous area installations: Purge Solutions model number PSCZ-3SD 15. Type : 230 VAC, Anodized aluminum, Dust hazardous area installations: Purge Solutions model number PSCZ-4AD 16. Type : 230 VAC, 316 stainless steel, Dust hazardous area installations: Purge Solutions model number PSCZ-4SD Vortex Cabinet Cooler Systems: For applications where thermal management of electrical cabinets and control panels are required; Purge Solutions offers Vortex Cabinet Cooler Systems, which provide cooling capacities for your application and maintain a NEMA 4 and 4X (IP66) rating for installation and use in hazardous area. Contact your local Purge Solutions representative or the factory for sizing of system and installation information.

OPTIONS & ACCESSORIES AVAILABLE CONTINUED: Continuous Dilution Purge Gas Inlet Kits: For interfacing and regulating pressure of protective gas supply to enclosure. Small Continuous Dilution Purge Gas Inlet Kits for enclosures with a volume up to 15 cubic feet (425 liters). Model number PSO-SCD-A is our small aluminum version and PSO-SCD-S is our small stainless version. Small Continuous Dilution Purge Gas Inlet Kits supply gas inlet to regulator is 1/4-18 FNPT. Medium Continuous Dilution Purge Gas Inlet Kits for enclosures with a volume up to 75 cubic feet (2,125 liters). Model number PSO-MCD-A is our medium aluminum version and PSO-MCD-S is our medium stainless version. Medium Continuous Dilution Purge Gas Inlet Kits supply gas inlet to regulator is 3/8-18 FNPT. Large Continuous Dilution Purge Gas Inlet Kits for enclosures with volumes up to 200 cubic feet (5,663 liters). Model number PSO-LCD-A is our large aluminum version and PSO-LCD-S is our large stainless version. Large Continuous Dilution Purge Gas Inlet Kits supply gas inlet to regulator is 1/2-14 FNPT. All kits include input fitting, regulator, gauge, bracket and mounting hardware. Manual Leakage Compensation Purge Gas Inlet Kits: Having two outlets from manifold able to increase the amount of purge gas to enclosure during dilution may be manually selected to speed up dilution of potentially flammable materials to an acceptable level, reducing dilution time and permitting a more rapid restoration of power to purge protected equipment. Small Manual Leakage Compensation Purge Gas Inlet Kits are for enclosures with a volume up to 15 cubic feet (425 liters). Model number PSO-SLC-A is our small aluminum version and model number PSO-SLC-S is our small stainless steel version. Small Manual Leakage Compensation Purge Gas Inlet Kits supply gas inlet to regulator is 1/4-18 FNPT. Medium Manual Leakage Compensation Purge Gas Inlet Kits are for enclosures with a volume up to 75 cubic feet (2,125 liters). Model number PSO-MLC-A is our medium aluminum version and model number PSO-MLC-S is our medium stainless steel version. Medium Manual Leakage Compensation Purge Gas Inlet Kits supply gas inlet to regulator is 3/8-18 FNPT. Large Manual Leakage Compensation Purge Gas Inlet Kits are for enclosures with volumes up to 200 cubic feet (5,663 liters). Model number PSO-LLC-A is our large aluminum version and PSO-LLC-S is our large stainless steel version. Large Manual Leakage Compensation Purge Gas Inlet Kits supply gas inlet to regulator is 1/2-14 FNPT. All kits include input fittings, regulator, gauge and manifold block. Back-Up Purge Gas Kit: In the even that the initial protective gas supply is lost, a back-up source of protective gas may be automatically applied to the protected enclosure. Purge Solutions model number is PSO-BUPG-K Back-Up Vents: To protect the enclosure from over pressure; Purge Solutions offers three sizes of back-up vents. The first size is our Small Back Up Vent for enclosures with a volume up to 15 cubic feet (425 liters). Model number PSO-SBUV-S is our small side mount version and model number PSO-SBUV-T is our small top mount version. The second size we offer is our Medium Back-Up Vent for enclosures with volumes up to 75 cubic feet (2.125 liters). Model number PSO- MBUV-S is our medium side mount version and model number PSO-MBUV-T is our medium top mount version. The third size we offer is our Large Back-Up Vent for enclosures with volumes up to 200 cubic feet (5,663 liters). Model number PSO-LBUV-S is our large side mount version and model number PSO-LBUV-T is our large top mount version. All Back-Up Vents are constructed of 316 stainless steel and come with all mounting hardware.

OPTIONS & ACCESSORIES AVAILABLE CONTINUED: Increase Safety Window Kits: Purge Solutions also offers 5 different sizes of Increase Safety Window Kits with each size available in anodized aluminum or 316 stainless steel bezel material, which can be mounted on the side, top or bottom of an enclosure. Model number PSO-1/32DINW- A is our 1/32 Din size with anodized aluminum bezel, model number PSO-1/32DINW-S is our 1/32 Din size with 316 stainless steel bezel. Model number PSO-1/16DINW-A is our 1/16 Din size with anodized aluminum bezel, model number PSO-1/16DINW-S is our 1/16 Din size with 316 stainless steel bezel. Model number PSO-1/8DINW-A is our 1/8 Din size with anodized aluminum bezel, model number PSO-1/8DINW-S is our 1/8 Din size with 316 stainless steel bezel. Model number PSO-1/4DINW-A is our 1/4 Din size with anodized aluminum bezel, model number PSO-1/4DINW-S is our 1/4 Din size with 316 stainless steel bezel. Model number PSO-XLW-A is our X-Large size with anodized aluminum bezel, model number PSO-XLW-S is our X-Large size with 316 stainless steel bezel. Protective Gas Loss Indicator Kit: An explosion-proof differential pressure switch may be installed to provide an alarm contact output signal to indicate the loss of the backup source of protective gas. Another explosion-proof differential pressure switch may be installed on the main protective gas supply to indicate that the primary protective gas pressure is adequate. Purge Solutions model number is PSO-PGLI-K. Differential Pressure Gauge Kits: Purge Solutions also offers an all stainless steel differential pressure gauge kit, which can be mounted on left side model number PSO-DPG-L, right side model number PSO-DPG-R, top model number PSO-DPG-T or bottom model number PSO-DPG-B of enclosure. GENERAL SPECIFICATIONS: Casing Dimensions: 4.5 diameter x 1.9 tall (114.3mm diameter x 48.3mm tall). Operating Temperature Range: - 40ºF to 150ºF (- 40ºC to 65ºC). Purge Pressure Lower Limit Setting: 0.50 inches H20 (1.25 mbar). Casing: Anodized aluminum, 2.48 lbs. (1.13 kg), IP66, NEMA 4, (standard). 316 stainless steel, 6.70 lbs. (3.04 kg), IP66, NEMA 4X, (optional). Power Input / Consumption: 0.5 Watts max.

GENERAL SPECIFICATIONS CONTINUED: Voltage: 12 VDC Model, polarity-protected. 24 VDC Model, polarity-protected. 115 VAC Model, 50 / 60 Hz. 230 VAC Model, 50 / 60 Hz. Dry Contact Rating: Contact open on alarm (Standard). Contact closed on alarm (Optional). 250 Volts AC / DC, 150mA max. Standard Hardware: All stainless steel mounting fasteners, o-ring, 1/4" (6.4mm) diameter vent restrictor, warning label, and CD with all required documentation. Hazardous Area Approvals: ATEX and IECEx II 3 G Ex na nl [pz] IIC T6 for Zone 2 gas hazardous areas II 3 D Ex td A22 IP66 T79 C for Zone 2 dust hazardous areas ANSI / ISA 12.4, NEC / NFPA 496, CSA and UL Class I, Division 2, Group A,B,C&D, T6 for gas hazardous areas Class II, Division 2, Group F&G, T6 for dust hazardous areas Certified to an Ambient Temperature Range of - 40ºF (- 40ºC) <Tamb< + 149ºF (+ 65ºC) CE Marked Purge Solutions : 2201 North Highway 35 Bypass, Suite C, Alvin, Texas 77511 USA : Telephone 832-368-7166 Web Site = http://www.purgesolutions.com : Email = info@purgesolutions.com : Document # DO-11010-S