Tamini is the leading Italian company in the world for the design and production of industrial, power and special transformers.

Similar documents
Transformers for Power Applications

TRANSFORMERS UP TO 750 kv

ZREW Transformers Perfection in Detail. a company of Rauscher & Stoecklin SERW ZREW Tesar

MOBILE SUBSTATION DESIGN Brad Bozich & Vitor Vieira 2755 Northwoods Parkway Norcross, Georgia

MEDIUM POWER TRANSFORMER

YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS

Distribution transformers Efficiency over life-cycle

Power Voltage Transformers for Air Insulated Substations

Maximum temp. rise in oil by 40 thermometer above design ambient (deg C) specified time Short circuit rating (Sec) for As per IS 2026

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

Fuji Electric. Oil immersed. Transformer FTU08A1-E-0024

ABB Transformers Egypt

Chapter 6 Generator-Voltage System

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

AIR CORE REACTORS. Phoenix Electric Corporation

CAST RESIN TRANSFORMERS CRT ED.: DEC.13 REV.00

DISTRIBUTION TRANSFORMERS CATALOGUE

EMPAC Metal enclosed capacitor bank for wind applications

GAS INSULATED VOLTAGE TRANSFORMERS.

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

HIGH POWER RECTIFIER SYSTEMS

AC/DC Arc Furnace and Ladle Furnace Transformers

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

(A Government Company) CENTRAL WORK SHOP KOTHAGUDEM

INESING GROUP. Power System Solution

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

ADVISE DESIGN IMPLEMENT FOR ELECTROTECHNICAL EXCELLENCE

B kv T&D GAS INSULATED SWITCHGEAR

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

Small wonder. Station service voltage transformers for small power requirements

Shunt reactors Proven history for future success

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

SWITCHGEAR DIVISION PRODUCT PROFILES

DRY TYPE TRANSFORMERS

Key features. DESIGNS: - Conservator type - Hermetically sealed

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

RPS Station. Solutions for the North American Solar Market

BUSHINGS AND ACCESSORIES FOR DISTRIBUTION AND POWER TRANSFORMERS

This tender addendum and clarification forms part of the Request for Proposal and Contract documents, and modifies them as follows:

EH2741 Communication and Control in Electric Power Systems Lecture 3. Lars Nordström Course map

MESG 12 / 17.5 / 24 / 36 KV

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

Electrical Power Systems 2014/15

Powering industry since 1947.

Study of Fault Clearing by A Circuit Breaker In Presence of A Shunt Capacitor Bank

Modular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.

Transformer Components & Accessories

Targeted Application of STATCOM Technology in the Distribution Zone

Power System Solutions (PSS)

Final Draft Report. Assessment Summary. Hydro One Networks Inc. Longlac TS: Refurbish 115/44 kv, 25/33/ General Description

CAST RESIN TRANSFORMERS

Power and Distribution Transformers

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

Transforming Transforming Advanced transformer control and monitoring with TEC

C1000 Series Automatic Cap Bank

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Unified requirements for systems with voltages above 1 kv up to 15 kv

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

B kv Gas-insulated Substations

Medium Voltage Metal-Enclosed Switches

S C ELECTRIC EUROPE LTD. Excellence Through Innovation. Harnessing the Wind. November 2011 Descriptive Bulletin E

P2 : About Us. P3 : Elsewedy Transformers. P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers. P7 : Technical Data Sheets

PPT EN. Industrial Solutions

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Power Conversion System The Best Technology for your photovoltaic and storage system

NEXT STEP B) SAFETY :

SPECIFICATION SS-52/15 8 MVAR 25 MVAR, 157.5kV SHUNT REACTORS

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

Service and Rehabilitation Electrical Power Systems

Our Global Solutions CAPABILITIES

Minera. Oil distribution transformers up to kva. eco design. Minera at a glance. Standards

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

Multifunctional transformers and innovative solutions for contingency planning

ELG4125: Flexible AC Transmission Systems (FACTS)

Surabaya Seminar Ferdinand Sibarani, Surabaya, 30 th October Power Quality

Gas-insulated medium-voltage switchgear. For the metal industry. Answers for energy.

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

Noxon Rapids Reactor Project. Scott Wilson June 9, 2016 Tracy Rolstad

Site Services. Asset Management for Modern Networks

SIGENTICS HV Series S-modyn

production program 1

CONVETT OIL - AIR COOLERS

Independent Testing Laboratory for High Voltage Equipment

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

2000 Cooper Bussmann, Inc. Page 1 of 9 10/04/00

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

Metal enclosed capacitor banks: ABBACUS family

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

tests Partial discharge level from day 1 10 pc Insulation 24 kv : impulse tested at 125 kv Insulation 36 kv : impulse tested at 170 kv, 200 kv indeed.

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

September 2008 TEC, INTELLIGENT MONITORING SYSTEM

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks

Electrification and Power Supply. Andrea Nardinocchi Technological Design Department Italferr S.p.A., Rome, Italy

DESIGN CONSIDERATIONS FOR APPLICATION OF SHUNT CAPACITORS IN HEAVY HATER PLANT (TUTICORIN)

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Transcription:

Power

Tamini is the leading Italian company in the world for the design and production of industrial, power and special transformers. Founded in 1916 in Milan, it supplies its products to the most important industrial sectors (i.e. steel, aluminum, mining, oil & gas, chemical and transportation) and the most highly qualified operators in the energy sector (production, distribution and transmission). More than 8,300 Tamini transformers have been manufactured and installed for customers in more than 90 countries around the world. Tamini manages 4 production plants in Italy and operates through its own subsidiaries in the USA and North Africa.

Power Tamini designs power transformers for the distribution, transmission and production of electricity from both conventional and renewable sources. The Company's products are designed to provide solutions for specific customer needs, effectively responding to ongoing technological progress in electricity generation, transmission and distribution.

The goal of the research and development activity is to achieve the best possible quality/price ratio of the Tamini products by a continuous improving of design criteria and manufacturing and testing facilities. Quality Assurance, Quality Control and Safety Research & Development QA procedures are carried out and certified according to ISO 9001-2000 Standards. QC is performed at every step: engineering, production cycles, procurement, testing and on site installation. All Tamini's factories have their own testing facilities suitable for the routine, type and special tests in accordance with IEC or IEEE (ANSI) and other worldwide recognized Standards (ASA, CSA, BSS, SEV etc.). Tamini definitely complies with the most updated international legislation for safety and environmental protection. Investigation on power transformers, includes the following activities: Losses and noise level reduction Analysis of electromechanical stresses due to short circuits Analysis of mechanical stresses due to seismic and transportation shocks Materials and components with improved characteristics and performances Diagnostic systems Analysis of electrical stress due to fast-transient over-voltages Fluid dynamics

Generator Step Up (GSU) GSU transformers is an essential component of a power plant since it links the generation system to the transmission grid. for Energy Production Plant Auxiliary The Auxiliary Transformer supplies loads which are essential to the operation of the power generation plants such as lighting supplies, cranes, workshops and other services. System voltage up to 72.5 kv Power rating up to 50 MVA System voltage up to 550 kv Power rating up to 550 MVA Three-phase and Single-phase units Customized design for spare GSU transformers that can be used in different power plants Customized interface transformer/grid: oil/air, oil/oil, oil/sf6

Transmission Transmission transformers are used to interconnect high voltage transmission systems. System voltage up to 550 kv Power rating up to 700 MVA for Transmission Autotransformers These are particular units where primary and secondary windings are not separated but with a portion in common. System voltage up to 550 kv Power rating up to 700 MVA Shunt Reactors Shunt reactors are used in a power system to compensate the capacitive reactive power required by the large HV grids. System voltage up to 420 kv Power rating up to 300 MVAr Three-phase and Single-phase units

Following the deregulation of the energy sector, modern power grids have an articulated structure covering large areas, often in different countries. Energy is no longer produced and consumed in the same country, in the same area, but it is traded on a large scale between different countries and areas. Therefore, it is necessary to manage the energy flow according to the supply contracts and not to the natural path determined by the physical parameters of the interconnected networks. A Phase-Shifting Transformer (PST) is a special unit, specifically used for managing the power flow through complex interconnection lines. This goal is achieved by controlling the phase displacement between the input and the output voltages of the transmission lines interconnected through the PST. Both, the magnitude and the direction of the power flow can be controlled by varying the phase shift. Similar considerations can be made about the reactive power flow, but based on the in-phase regulation of the voltages. Some examples of PSTs Here below a short description of the most important PSTs manufactured by Tamini over the years. a) One core design with both in-phase and shifting regulation, 75 MVA Primary side: 154.5 kv +18/-10 x 1.97 kv with on load tap changer for in-phase regulation Secondary side: 138 kv ± j16 x 3.84 kv allowing a no load shifting capability of ±24 with on load tap changer b) One core design with both in-phase and shifting regulation, 62.5 MVA Primary side: 236 kv +18/-10 x 2.95 kv with on load tap changer for in-phase regulation Secondary side: 160 kv ± j16 x 4.045 kv allowing a no load shifting capability of +29-14.1 with on load tap changer for the symmetrical range of regulation, plus an off circuit tap changer to extend or reduce furthermore the angle regulation range The above mentioned units have been the first ones installed in the world with a special winding arrangements to obtain in-phase and angle regulation with only two three phase tap changers and with several working possibilities. c) Tamini one core design record is a 160 MVA PST 230 kv +24/-4 x 2.726 kv primary side (with OLTC for in-phase regulation) and secondary side 132 kv +± j17 x 5.426 kv to obtain ±35 of shifting capability with on load tap changer. The transformer is OFAF type. The unit is also equipped with a tertiary winding for feeding auxiliary equipment. The weight of the unit is approximately 240 Tons. Phase Shifting (PST) In order to satisfy these requirements, several design solutions of PST are available. The most common types are: Two-core design in symmetric and asymmetric configuration Single-core design in symmetric and asymmetric configuration Both of them allow a possible addition of an in-phase voltage regulation, to compensate the net voltage fluctuation or to combine in-phase and quadrature regulation. System voltage up to 420 kv with in-phase regulation if required Through-put rating up to 1800 MVA d) Another special application developed by Tamini is an autotransformer 150/200 MVA with primary voltage 330 kv and secondary voltage 161 kv ± 8 x 1.25% (with on load tap changer for in-phase regulation). This is also equipped with additional off circuit tap changer ±2 x 12 kv which allows shifting capability of ±6. This autotransformer is the only installation in the world with this capability. e) Two core design with both in-phase and shifting regulation, 160 MVA, obtained by coupling a main unit with a booster unit Primary side: 230 kv +16/-8 x 1.24% with on load tap changer for in-phase regulation Secondary side: 155 kv ± j16 x 2.54% allowing a no load shifting capability of ±22 with on load tap changer Total weight of the two assembled unit is 366 tons. f) The biggest units manufactured by Tamini (Two-core symmetric design among the largest in the world) have a throughput power of 1800 MVA with maximum shift angle of ±17,5. Each unit is composed by two transformers, connected together with inlet and outlet voltage of 400 kv and angle shift adjustable by a 33 positions OLTC. Moreover, in order to invert the phase angle, an "advanced-retard" switch (ARS) is installed.

HV/MV HV/MV can be manufactured either with off-circuit tap changer or on-load tap changer and with different cooling methods. Furthermore, transformers for railway application with various loading cycles can be manufactured as well. System voltage up to 420 kv Power rating up to 250 MVA Dry type MV/MV, MV/LV and LV/LV for Distribution Dry-type transformers are used to minimize fire hazard and other environmental contamination on surroundings and people, like in large office buildings, hospitals, shopping centers and warehouses, sea going vessels, oil and gas production facilities and other sites where a fire has potential for catastrophic consequences. Distribution transformers MV/MV, MV/LV and LV/LV type for energy distributions in our production range are dry type AIR FILLED, with AN or AF (or combined) cooling method, class H or F, in accordance with E0, F0 and C0 class. Our transformers can be offered also with protection box IP 21/31/44/54, in accordance with international standards. in this range are three phase or single phase and can be manufactured either with off-circuit tap changer or on load tap changer. MV/LV System voltage up to 36 kv Power rating up to 10 MVA MV/LV transformers act as final voltage transformation step in the electrical power distribution system. Distribution transformers MV/LV type for energy distributions are usually three or single phase, oil immersed, with different cooling method (K/L)ONAN - (K/L)ONAF with detachable radiators or corrugated tank (depending on transformer size and ambient temperature), with conservator technology or sealed construction (with or without nitrogen/air filling). These transformers can be manufactured either with off-circuit tap changer or on-load for environments with risk of explosion (ATEX) and for off-shore application. Furthermore, transformers for railway application with various loading cycles can be manufactured. System voltage up to 52 kv Power rating up to 30 MVA

Short-Circuit Test Room Short-circuit test room transformers are used in test laboratories to check the short-circuit withstand capability of electric devices such as circuit-breakers, switches, transformers, etc. An extremely solid design is required for this type of transformers, for which the short-circuit is their operating condition. Neutral Earthing Transformer and Reactors The practice of earthing the neutral of large generators, as well as transformers, aims to restrict the earth fault current to a low value and thereby limiting the damage caused in the event of a fault. Earthing transformers (neutral couplers) Special Three-phase zig-zag unit to provide a neutral connection for earthing purposes, directly or through an impedance. It can be equipped with an auxiliary LV winding to supply auxiliary loads. Current limiting reactors These series reactors are used to reduce the short circuit currents in the power system. Dry type are used as alternative to the oil filled type. Neutral earthing reactors Mobile Substation Mobile transformers are used when power needs to be temporarily supplied in a particular place and situation, like in cases of a system failure, system maintenance or civil construction. A typical mobile substation is electrical fully equipped and installed on one or more trailers, to be transported by road according to customer requirement. An optimum solution in terms of design is always a path to be walked side by side by the end-user and the manufacturer. These reactors are single phase units used to ground neutral terminals in MV networks, directly or by impedance. Dry type are used as alternative to the oil filled type. On requests, any Tamini solution can be studied for mobile applications (to be installed on trailers) for earthing MV side of power transformer. System voltage up to 170 kv Customized through power rating related to neutral fault current System voltage up to 245 kv Customized power rating related to trailer dimensions, maximum transportable weight, cooling system and thermal class

Bushings The bushings can be either of the oil/air type or oil/oil, in case of connections to cables in oil filled terminal boxes, or also oil/sf6 for connection to SF6 filled bus-bar ducts. HV bushings are usually of the condenser type with oil impregnated or with resin impregnated paper. Power Accessories Tap-Changers The transformers can be equipped either with on-load or no-load tap changer fitted on the HV side. The on-load tap-changers are suitable for local and remote operation and are fitted with all the accessories and with a marshalling cabinet mounted on the transformer tank. They can feature a device for parallel operation. Cooling System The transformers can be designed for any applicable cooling system following the requirements of the end user. The most used cooling systems for power transformers are ONAN and ONAF. These systems are achieved by radiator banks, mounted on the sides of the transformer tank, or in separate banks, with or without cooling fans. The cooling can also be OFAF (or ODAF) and OFWF (or ODWF) with coolers assembled on the transformer tank or in a separate bank.

Tank and Oil Expansion Tank The tank is made by welded steel streets creating a strong and stiffened structure to support full vacuum and over-pressure. The internal walls of the tank are painted with an hot oil resistent coating while externally the tank is painted according to Tamini Quality Assurance procedure. Specific painting requirements can be adopted on request. Power Accessories Ancillaries The power transformers are equipped with the following fittings and accessories: Two air silica gel breathers for the two conservator sections Two oil level indicators with electric contacts for the two conservator sections Buchholz relay with alarm and trip contacts Oil drain, filling and filtering valves Oil thermometer complete with alarm and trip contacts and, on request, a device for remote temperature monitoring Current transformers as per customers requirements Over-pressure protection Lifting lugs for core and winding Lifting lugs for the complete transformer Marshalling box for signaling and protection auxiliary circuits Earthing terminals Oil sample valve The tank is equipped with an oil conservator divided in two sections for transformers oil and OLTC switch oil. Suitable manholes for internal inspection and maintenance are provided on the tank.

INTERNO OTTO - ROME Editorial Design / Interno Otto Rome Photographs / Massimo Cangelli and Tamini Archive EVERY TAMINI TRANSFORMER IS DESIGNED TO BE UNIQUE Unique in its Quality Because Tamini has a production philosophy centred around people, combining the most advanced technologies with the quality and reliability of artisan products, making it an international leader in Made in Italy production. Unique in its Technology Because Tamini invests continuously in research and development, and guarantees installation and support services of the very highest technical order. Unique in its Customer Satisfaction Because Tamini designs its transformers according to the specific needs of each individual client, positioning itself at the top end of Made in Italy. www.tamini.it

INTERNO OTTO - ROME Tamini Trasformatori S.r.l. - Headquarters Via Cesare Battisti, 43-20077 Melegnano (Milano) - Italy Ph. +39.02.982051 - Fax +39.02.98231524 www.tamini.it Tamini Production Facilities Via Emilia, 37-20077 Melegnano (Milano) Italy Ph. +39.02.982051 - Fax +39.02.98231524 Via P. Ovidio Nasone, 5-20025 Legnano (Milano) Italy Ph. +39. 0331.51381 Corso Risorgimento, 209-28100 Novara Italy Ph. +39. 0321.473371 VTD Trasformatori S.r.l. Via Gasdotto, 6-36078 Valdagno (Vicenza) - Italy Ph. +39.0445.409080 r.a. - Fax +39.0445.409733 Tamini USA LLC 2803 Butterfield Road, Suite 385, Oak Brook, IL 60523 - USA Ph. 630.368.9907 - Fax 630.368.9910 Tamini Algeria 95, Cadat, Les Sources, Bir Mourad Rais, 16005 Alger - Algérie Mobile +39.335.6886235 - Fax 021543968