Pilot kick type 2 port solenoid valve for dry air (general purpose valve) ADK11-Z Series. NC (normally closed) type

Similar documents
AB41E4-Z Series. Pressure and explosion proof structure d2g4 (flame-proof grade 2, ignitability G4) NC (normally closed) type. Port size: Rc1/4, Rc3/8

General purpose direct acting 2, 3 port solenoid valve

NO (normally closed) type Common supply type (port C pressurization) MPa MPa MPa C C

Pilot operated 2 port solenoid valve (general purpose valve) AP11/AP12 Series. Air, water, kerosene, oil (50 mm 2 /s or less) -10 to to 60 B

Discrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type

Discrete direct acting 3 port solenoid valve (general purpose valve) NC pressurization type. Port size: Rc1/8, Rc1/4, Rc3/8

Discrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8

Discrete direct acting 3 port solenoid valve (general purpose valve) Universal type Port size: Rc1/8, Rc1/4, Rc3/ to to 60 B

CVE2/CVSE2 CVE3/CVSE3

HVB/HVL. Solenoid valve for high vacuum. For vacuum, inert gas, air, nitrogen CONTENTS. Overview

Pilot operated 2 port valve for dust collector control (pulsejet valve) Common specifications Air operated type. Solenoid valve mounted type Item OUT

HN B G1/US B G2/US B G3

Discrete air operated 2 port valve (compact cylinder valve) NC (normally closed) type

PD3/PDV3-20A/25A/40A Series

GENERAL PURPOSE VALVE AB31 AB41 AB42 SERIES Discrete valve. Direct acting poppet structure Port size : Rc1/8, Rc1/4, Rc3/8, Rc1/2.

New Products COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER. Lightweight and large flow rate, low power consumption Improved corrosion resistance!

PDVE4 Series PDVE4 20A 3T AC100V. Explosion proof 2 port solenoid valve for dust collector control (explosion proof pulsejet valve)

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm

2 port pilot operated solenoid valve

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

New Products. 3 Port Solenoid Valve with Spool Position Detection SNP Series

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Vacuum pump system type

4F0/1/2/3 Series. Min. working pressure MPa Refer to the individual specifications below to 60 Lubrication Not required (when lubricating,

Pilot Operated 2 Port Solenoid Valve for Dry Air

Soft Start-up Valve. AV2000/3000/4000/5000 Series

High Pressure Coolant Valve

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

Energy efficiency and Flow

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

1.0 cm 3 /min. Pilot Operated 2-Port Solenoid Valve/ Zero Pressure Differential Operation Series VXS22/23. Compact and Lightweight mm.

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

Coolant Valve. Air Operated/External Pilot Solenoid

Pilot Operated 2 Port Solenoid Valve for Dry Air

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

Exclusively for air pressure system and air-hydro circuit control

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

Series VP3145/3165/3185

Compact Proportional Solenoid Valve

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Series AV2000/3000/4000/5000

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

3 Port Solenoid Valve

3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application.

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Coolant Valve. VNC Series. Cylinder actuation by pilot air

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Design & Selection. Installation & Adjustment

2/3 Port Valve for Various Fluids Control

Compact / Lightweight 2 Port Solenoid Valve

Series VP3145/3165/3185

Series VQ Port Solenoid Valve

3 Port Solenoid Valve Direct Operated Poppet Type

Installation and Maintenance Manual VXZ Zero Pressure Differential Type Pilot Operated 2 Port Solenoid Valve

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Doc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number

MYB1/MYG1 Series DC12V. Metal free 2, 3 port solenoid valve for chemical liquid

VX Z. Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve VXZ22/23. For Air, Water, Oil. New. Series

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

MICRO EJECTORS ME12, ME25, ME60. Specifications. Mass MICRO EJECTORS. Vacuum switches. Micro ejectors. Single and twin solenoid valves.

Air Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. Port size: 1/4 to 1 JIS symbol Specifications Description

3 Port Solenoid Valve

Flow Switch Diaphragm Style Flow Switch IFW5 10 N Diaphragm style flow switch. Thread type. Nil. Body size Note)

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

MULTISTAGE MICRO EJECTORS

Design and selection. Installation and adjustment

Ready for outdoor use too!

1.3 x % reduction 18% High Vacuum Solenoid Valve. XSA Series CAT.ES140-7B. 5 to 60 C

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Compact direct acting precision regulator

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

Specifications VH600. Ambient temperature and operating fluid temperature. Operating angle Lubrication. Semi-standard

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Plug-in manifold W4G4 Series

Vacuum / Release Unit

Motorized Two-Way Ball Valve with Screwed-End Connection

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

Series VC Direct Operated 2 Port Solenoid Valve for Oil. Series VCL VX VN VQ VDW VC LV PA

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Process Valve HPW 6524NO [4] - 28 HPW 3212FO~5020FO [4] - 29 HPW6524FO [4] - 30

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure

Process Valve/Series VN

EX Series. Electric Actuators for Ball and Butterfly Valves

Doc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Check Valve AP64 P.149. Vacuum Generator Vacuum Generator Module Vacuum Generator Module AP7 & 70 AP71 AP72. Flow Switch Flow Switch (For high flow)

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42)

AV2000-A/3000-A/4000-A/5000-A

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air

Transcription:

Pilot kick type 2 port solenoid valve for dry air (general purpose valve) DK11-Z Series NC (normally closed) type Port size: Rc1/4 to Rc1 Diaphragm structure JIS symbol NC (normally closed) type OUT IN Common specifications Item Working fluid Working pressure differential range Max. working pressure Withstanding pressure (water) Fluid temperature mbient temperature eat proof class MPa MPa C C tmosphere Valve structure cm3/min. (NR) Valve seat leakage Mounting attitude Standard specifications Dry air (atmospheric dew point -60 C or more), inert gas, low vacuum (1.33 x 10 3 Pa (abs)) 0 to 0.7 (refer to max. working pressure differential in individual specifications.) 2 4-10 to 40 (no freezing) -10 to 40 B Place free of corrosive gas and explosive gas Pilot kick type poppet, diaphragm structure 1 (at pressure 0.02 to 0.7 MPa for 8/10, and at 0.02 to 0.6 MPa for 15 to 25)* Free * When used at a pressure less than 0.02 MPa, the sealant may be unstable. Consult with CKD in this case. Individual specifications Item DK11-8-*****Z -10-*****Z -15-*****Z -20-*****Z -25-*****Z Port size Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1 Orifice (mm) 12 12 16 23 28 Min. working pressure diff. (MPa) *1: The model numbers above show the basic port size (Rc). Refer to ow to order for other combinations. *2: Voltage fluctuation should be within ±10% of the rated voltage. *3: Keep the leakage current at the following value. 0 Max. working pressure diff. (MPa) 0.7 0.7 0.6 0.6 0.6 Rated voltage 100 V /60 z 200 V /60 z 12 VDC 24 VDC 48 VDC 100 VDC Power consumption (W) DC 17 14 Leakage current Voltage 100 V 200 V 12 VDC 24 VDC 48 VDC 100 VDC DK11-8 to 25-*****Z 10 m 5 m 40 m 20 m 10 m 5 m 348

DK11-Z Series Flow characteristics Port size Orifice Flow characteristics (mm) C [dm 3 /(s bar)] b S (mm 2 ) DK11-8-*****Z DK11-10-*****Z DK11-15-*****Z DK11-20-*****Z DK11-25-*****Z Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1 12 12 16 23 28 9.2 11 20 0.36 0.46 0.31 162 231 *1: Effective sectional area S and sonic conductance C are converted as S 5.0 C. NB/ USB/ FB/ FB/ FVB FWB/ FB FLB B P/ D PK/ DK For dry air Explosion proof VB/ VL SB/ SVB NP/NP/ NVP CB/ MXB/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve for dry air Pilot kick type 2 port solenoid valve 349

DK11-Z Series ow to order DK11 15 3 B S Z DC24V E Mounting plate Voltage Surge suppressor F Other options D Coil housing Port size B Type of thread C Body/sealant combination Symbol Port size 8 1 / 4 10 3 / 8 15 1 / 2 20 3 / 4 25 1 B Type of thread N C Body/sealant combination Body Sealant Treatment Remarks J L M Rc NPT Bronze Stainless steel Nitrile rubber Fluoro rubber Nitrile rubber Fluoro rubber Descriptions Oil free Refer to page 36 in the Introduction for details on the material combinations. D to Refer to the following page for details on the coil housing, other options and voltage, etc. <Example of model number> DK11-15-3BSZ-DC24V Series: DK11 Port size: 1/2 B Type of thread: Rc C Body/sealant combination : Body - bronze, sealant - nitrile rubber D Coil housing : Open frame lead wire for DC voltage E Mounting plate: Selected F Other options: Blank Surge suppressor: Selected Voltage: 24 VDC 3

DK11-Z Series NB/ USB/ For D to, the combinations indicated with symbols can be manufactured. Note that if options E to are not required, no symbol is indicated. FB/ D Coil housing E F Other options Rated voltage Cable gland Conduit Descriptions (Marine cable gland) (Conduit pipe) Descriptions -15a -15b -15c CTC19 1/2 3 3M 3N 3I 3J 5 5M 5N 5I 5J 3 5 3M 3N 5M 5N Open frame type Open frame type (Diode integrated) Lead wire + light (IP65 or equivalent) (1/2) (1/2) (1/2) + light (IP65 or equivalent) (1/2) Lead wire (1/2) + light (1/2) (IP65 or equivalent) (1/2) + light (IP65 or equivalent) (1/2) Manual override (locking) Open frame grommet lead wire 300 mm 5 (diode integrated) Open frame 5M, 5N (diode integrated) D E F D E F Surge suppressor S 12 VCD, 24 VDC, 48 VDC, 100 VDC 12 VDC, 24 VDC, 100 VDC 12 VCD, 24 VDC, 48 VDC, 100 VDC 12 VDC, 24 VDC, 100 VDC 100 V, 200 V Refer to the following precautions for D to. Conduit (CTC19) (1/2) FB/ FVB FWB/ FB FLB B P/ D PK/ DK For dry air Explosion proof VB/ VL SB/ SVB NP/NP/ NVP 3I 3J 5I 5J Open frame (IP65 or equivalent) 5I, 5J (diode integrated) Refer to page 306 for coil selection. Note on model no. selection Note on D * 1: 5, 5M, 5N, 5I and 5J are coils for which power is converted to DC with a diode. Not compatible with voltages less than 100 V. Note on E to * 2: Select one among D, E, F, and for F. * 3: The surge suppressor is an accessory for the lead wire coil. When selecting a coil with terminal box, the surge suppressor is mounted in the terminal box. * 4: The surge suppressor is incorporated in the coil with diode as standard. * 5: Tropicalization (rust-proof coating) is available as a measure against rust. Contact CKD for more information. Note on * 6: 100 V coil is compatible with 100 V /60 z, and 200 V coil is compatible with 200 V /60 z. * 7: For voltages other than above, consult with CKD. * 8: The lead wire is available in the standard 300 mm length, and 0 mm, 1000 mm, 2000 mm and 3000 mm lengths. Contact CKD for more information. 351 CB/ MXB/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve for dry air Pilot kick type 2 port solenoid valve

DK11-Z Series Internal structure and parts list DK11-Z Series 1 2 3 4 5 6 7 8 9 10 11 Figure shows DK11-8/10. 12 No. Parts name Material 1 Core assembly SUS405 or equivalent, 316, 403 Stainless steel 2 Coil assembly 3 4 Remaining magnetic force eraser PPS Plunger spring SUS304 Polyphenylene sulfide Stainless steel 5 6 Plunger Wear ring SUS405 or equivalent POM Stainless steel cetar resin 7 Valve sealant NBR (FKM) NBR: Nitrile rubber 8 O ring NBR (FKM) (FKM: Fluoro rubber) 9 O ring NBR (FKM) 10 Diaphragm assembly SUS304, NBR (FKM) Stainless steel, nitrile rubber (fluoro rubber) 11 Body 12 Stuffing C408 (SCS13) C3771 (SCS13) Bronze (stainless steel) Brass (stainless steel) ( ) shows options. Dimensions Open frame lead wire type DK11-*-* 3 ***Z 5 28 42 (300) 46 C D E B F DK11-8-*****Z DK11-10-*****Z DK11-15-*****Z DK11-20-*****Z DK11-25-*****Z B C D E 71 80 90 23 23 29 35 45 11.5 11.5 14.5 17.5 22.5 68.5 68.5 75.5 79 84.5 92.5 92.5 102 108.5 119 F 46 46 60 71 Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1 352

DK11-Z Series Optional dimensions Open frame type + DK11-*-* 3M***Z 5N * Refer to the open frame lead wire type dimensions on the left page for common dimensions. NB/ USB/ FB/ 72 103 FB/ FVB FWB/ 29 FB 58 FLB 45 B Open frame type + conduit DK11-*-* 3 5 57 (60) 1/2 P/ D PK/ DK For dry air Explosion proof VB/ VL SB/ SVB NP/NP/ NVP CB/ MXB/ Mounting plate DK11-*-** B **Z Dimensions shown in ( CTC19 (1/2) ) are for 1/2. Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order J K L DK11-8-**B**Z DK11-10-**B**Z DK11-15-**B**Z DK11-20-**B**Z DK11-25-**B**Z J K 30 30 40 45 56 63 75 ø7 ø7 ø9 ø9 ø11 2 2 3.2 3.2 3.2 L 33.5 33.5 45 56 eneral purpose valve for dry air Pilot kick type 2 port solenoid valve 353

2, 3 port solenoid valve for dry air (general purpose valve) Electronic Catalog file list 2, 3 port solenoid valve for dry air (general purpose valve) Direct acting 2 port B_Z (pages 316 to 317) DXF Folder name Filename B31-Z B _ Z B31-Z-K/ B31-Z- B31-Z-SUS B41-02-Z B41-02-7-Z B41-03/04-Z B41-Z-K/ B41-02-Z- B41-02-7-Z- B41-02-Z-SUS B41-02-7-Z-SUS B41-03/04-Z-SUS B3-Z B3-Z- Mounting plate, cable gland, conduit Direct acting 3 port _Z (pages 326 to 327) 354 3-Z 3-Z-K/ 3-Z- 3-Z-SUS 4-02-Z 4-03-Z 4-Z-K/ 4-02-Z- 4-03-Z- 4-02-Z-SUS 4-03-Z-SUS 3-Z 3-Z- Mounting plate, cable gland, conduit Folder name _ Z ab31 _ z ab31 _ z _ k _ h ab31 _ z _ a ab31 _ z _ sus ab41 _ 02 _ z ab41 _ 02 _ 7 _ z ab41 _ 03 _ 04 _ z ab41 _ z _ k _ h ab41 _ 02 _ z _ a ab41 _ 02 _ 7 _ z _ a ab41 _ 02 _ z _ sus ab41 _ 02 _ 7 _ z _ sus ab41 _ 03 _ 04 _ z _ sus gab3 _ z gab3 _ z _ a ab _ ag _ z _ op DXF Filename ag3 _ z ag3 _ z _ k _ h ag3 _ z _ a ag3 _ z _ sus ag4 _ 02 _ z ag4 _ 03 _ z ag4 _ z _ k _ h ag4 _ 02 _ z _ a ag4 _ 03 _ z _ a ag4 _ 02 _ z _ sus ag4 _ 03 _ z _ sus gag3 _ z gag3 _ z _ a ab _ ag _ z _ op Explosion proof direct acting 2 port B*E-Z (pages 342 to 343) Folder name DXF Filename B41E-02-Z B _ E _ Z ab41e _ 02 _ z B41E-02-7-Z ab41e _ 02 _ 7 _ z B41E-02-Z- ab41e _ 02 _ z _ a B41E-03-Z- ab41e _ 03 _ z _ a ccessory (mounting plate, manual mounting plate) a _ e _ f Explosion proof direct acting 3 port 4*E-Z (pages 346 to 347) Folder name DXF Filename 4E-02-Z _ E _ Z ag4e _ 02 _ z 4E-03-Z ag4e _ 03 _ z 4E-02-Z- ag4e _ 02 _ zva 4E-03-Z- ag4e _ 03 _ z _ a ccessory (mounting plate, manual mounting plate) a _ e _ f Pilot kick type 2 port DK_Z (page 352) DK11-8/10-Z DK11-15-Z DK11-20-Z DK11-25-Z Folder name DK _ Z DXF Filename adk11 _ 8 _ 10 _ z adk11 _ 15 _ z adk11 _ 20 _ z adk11 _ 25 _ z Electronic Catalog file list is applied to "CD DT 2006". MICRO CDM Filename (ROUP: CD, USER: STDLIB) CKD-B31-Z CKD-B31-Z-K/ CKD-B31-Z- CKD-B31-Z-SUS CKD-B41-02-Z CKD-B41-02-7-Z CKD-B41-03/04-Z CKD-B41-Z-K/ CKD-B41-02-Z- CKD-B41-02-7-Z- CKD-B41-02-Z-SUS CKD-B41-02-7-Z-SUS CKD-B41-03/04-Z-SUS CKD-B3-Z CKD-B3-Z- CKD-B/-Z-OP MICRO CDM Filename (ROUP: CD, USER: STDLIB) CKD-3-Z CKD-3-Z-K/ CKD-3-Z- CKD-3-Z-SUS CKD-4-02-Z CKD-4-03-Z CKD-4-Z-K/ CKD-4-02-Z- CKD-4-03-Z- CKD-4-02-Z-SUS CKD-4-03-Z-SUS CKD-3-Z CKD-3-Z- CKD-B/-Z-OP MICRO CDM Filename (ROUP: CD, USER: STDLIB) CKD-B41E-02-Z CKD-B41E-02-7-Z CKD-B41E-02-Z- CKD-B41E-03-Z- CKD-*E-F MICRO CDM Filename (ROUP: CD, USER: STDLIB) CKD-4E-02-Z CKD-4E-03-Z CKD-4E-02-Z- CKD-4E-03-Z- CKD-*E-F MICRO CDM Filename (ROUP: CD, USER: STDLIB) CKD-DK11-8/10-Z CKD-DK11-15-Z CKD-DK11-20-Z CKD-DK11-25-Z

P/PK/D/DK (eneral purpose valve) eneral purpose pilot operated 2 port solenoid valve For air, vacuum, water, oil NB/ USB/ FB/ FB/ Overview FVB The general purpose valve series enables control of various types of fluids including water, air, oil and vacuums. In addition to the high reliability and high quality of the valve, the variety of options and variations are available. FWB/ FB FLB B Features Various working fluids control Various types of fluids can be handled by selecting the proper body material and sealant. Wide option range Including open frame, coil with diode, and terminal boxes. great variety of series and variation wide selection is available from the Rc1/4 to large flanges with series such as pilot operated diaphragm and piston valves, and pilot kick type diaphragm and piston valves. CONTENTS Series variation 220 Coil selection guide 222 Safety precautions 226 Pilot operated 2 port solenoid valve Piston structure P11/12 NC (normally closed) type / NO (normally open) type 228 P21/22 NC (normally closed) type / NO (normally open) type 238 Diaphragm structure D11/12 NC (normally closed) type / NO (normally open) type 248 D21/22 NC (normally closed) type / NO (normally open) type 258 Pilot kick type 2 port solenoid valve Piston structure PK11 NC (normally closed) type 268 PK21 NC (normally closed) type 276 Diaphragm structure DK11/12 NC (normally closed) type / NO (normally open) type 282 PK21 NC (normally closed) type 294 Electronic Catalog file list 300 lways read the precautions in the Introduction and page 226 before starting use. 219 P/ D PK/ DK For dry air Explosion proof VB/ VL SB/ SVB NP/NP/ NVP CB/ MXB/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve Pilot operated/pilot kick type 2 port solenoid valve

Series variation eneral purpose pilot operated 2 port solenoid valve No. of port 2 port Model P11 P12 P21 P22 D11 D12 D21 D22 PK11 PK21 DK11 DK12 Pilot operated (Piston structure) Pilot operated (Diaphragm structure) Pilot kick type (Piston kick drive) DK21 *2: 20 mm 2 /s for PK11/12 Series. *1 *1 *1 *1 Structure Pilot kick type (Diaphragm structure) ctuation NC (normally closed) type NO (normally open) type NC (normally closed) type NO (normally open) type NC (normally closed) type NO (normally open) type NC (normally closed) type NO (normally open) type NC (normally closed) type NC (normally closed) type NC (normally closed) type NO (normally open) type NC (normally closed) type ir Low vacuum Water Kerosene (1.33 x 103 Pa [abs]) Working fluid Oil ( mm 2 /s ) *2 *2 ot water Steam 220

Port size Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1 Rc1 1/4 32 flange Rc1 1/2 40 flange Rc2 flange *3 *3 *3 *3 *3 *3 *3 *3 *3 *3 *3 *3 *3 *3 *4 *3 *3 *4 *3 *3 *3 *3 *3 *3 *3 *3 *3 *3 *3 *3 *3 228 228 238 238 248 248 258 258 268 276 282 282 294 *3: Refer to each ow to order column for the thread types. Refer to page 222 for details on the coil system. Page NB/ USB/ FB/ FB/ FVB FWB/ FB FLB B P/ D PK/ DK For dry air Explosion proof VB/ VL SB/ SVB NP/NP/ NVP CB/ MXB/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order 221 eneral purpose valve Pilot operated/pilot kick type 2 port solenoid valve

Coil selection guide Coil housing types and selection guide wide variety is available to match applications. Refer to the structure and features to select the optimum model. P/D* ppearance Coil variations dedicated (/60 z common) eat proof temperature 130 C Protection property symbols: IP61 or equivalent Outdoor use not available DC and (/60 z common) eat proof temperature 130 C Protection property symbols: IP61 or equivalent Outdoor use not available DC and (/60 z common) eat proof temperature 130 C Protection property symbols: IP65 or equivalent Outdoor use not available rommet lead wire Lead wire DIN terminal box Lead wire length 300 mm Easy wiring and maintenance Reliable electric protection (ground terminal) Light available (optional - 100, 200 V and 24 VDC only) Lead wire length 300 mm Conduit (CTC19) for direct conduit wiring can be mounted 2C 6C 2E 2 2 6E 6 6 3 DC and (/60 z common) eat proof temperature 130 C Protection property symbols: IP21 or equivalent Outdoor use not available Easy wiring Light available (optional - 100, 200 V / 24, 100 VDC only) 3M 3N DC and (/60 z common) eat proof temperature 130 C Protection property symbols: IP65 or equivalent Outdoor use not available Easy wiring Light available (optional - 100, 200 V / 24, 100 VDC only) 3I 3J eat proof class taped dedicated (/60 z common) eat proof temperature 180 C igh temperature fluid and high ambient temperature available Outdoor use not available Protection property symbols: IP00 Lead wire Lead wire length 300 mm Conduit (CTC19) for direct conduit wiring can be mounted 4 Open frame type with diode diode is mounted on the coil section for direct-current conversion (-DC conversion) dedicated (/60 z common) eat proof temperature 130 C Protection property symbols: IP65 or equivalent Perfect for places where beat can be a problem Outdoor use not available Lead wire Easy wiring Light available (optional - 100, 200 V only) Lead wire length 300 mm Conduit (CTC19) for direct conduit wiring can be mounted 4M 4N 5 with diode diode is mounted on the coil section for direct-current conversion (-DC conversion) dedicated (/60 z common) eat proof temperature 130 C Protection property symbols: IP21 or equivalent Perfect for places where beat can be a problem Outdoor use not available Easy wiring Light available (optional - 100, 200 V only) 5M 5N with diode diode is mounted on the coil section for direct-current conversion (-DC conversion) dedicated (/60 z common) eat proof temperature 130 C Protection property symbols: IP65 or equivalent Perfect for places where beat can be a problem Outdoor use not available Easy wiring Light available (optional - 100, 200 V only) 5I 5J Conduit Use a conduit (CTC19 or 1/2) when using direct conduit wiring for the open frame lead wire. 222

Repair parts table per coil option Coil option symbol Voltage Repair parts Plunger assembly Core assembly Coil assembly ctuator assembly *1 NB/ 0 or 2C USB/ 6C *2 DC FB/ FB/ 2E 2 2 2E 2 2 6E 6 6 *2 DC DC FVB FWB/ FB 3 DC FLB B 3M 3N 3I 3J 4 DC DC P/ D PK/ DK For dry air Explosion proof VB/ VL SB/ SVB NP/NP/ NVP CB/ 4M 4N MXB/ Other.P. systems PD/FD/ PJ 5 CVE/ CVSE CPE/ CPD Medical analysis 5M 5N Custom order 5I 5J *1: The actuator assembly includes the coil assembly, core assembly and plunger assembly. *2: s 6C, 6E, 6 and 6 are dedicated parts, they are provided as part of the actuator assembly. 223 eneral purpose valve Pilot operated/pilot kick type 2 port solenoid valve

Coil selection guide Coil housing types and selection guide Wide coil variation is available. Refer to the structure and features to select the optimum model. PK11/DK1* ppearance Coil variations dedicated (/60 z common) eat proof temperature 130 C Protection property symbols: IP61 or equivalent Outdoor use not available DC and (/60 z common) eat proof temperature 130 C Protection property symbols: IP61 or equivalent Outdoor use not available rommet lead wire DIN terminal box Lead wire length 300 mm Easy wiring and maintenance Reliable electric protection (ground terminal) Light available (optional - 100, 200 V and 24 VDC only) 2C 2E 2 2 DC and (/60 z common) eat proof temperature 130 C Protection property symbols: IP65 or equivalent Outdoor use not available Lead wire Lead wire length 300 mm Conduit (CTC19) for direct conduit wiring can be mounted 3 DC and (/60 z common) eat proof temperature 130 C Protection property symbols: IP21 or equivalent Outdoor use not available Easy wiring Light available (optional - 100, 200 V / 24, 100 VDC only) 3M 3N DC and (/60 z common) eat proof temperature 130 C Protection property symbols: IP65 or equivalent Outdoor use not available Easy wiring Light available (optional - 100, 200 V / 24, 100 VDC only) 3I 3J *1 eat proof class taped dedicated (/60 z common) eat proof temperature 180 C igh temperature fluid and high ambient temperature available Outdoor use not available Protection property symbols: IP00 Lead wire Lead wire length 300 mm Conduit (CTC19) for direct conduit wiring can be mounted 4 Open frame type with diode diode is mounted on the coil section for direct-current conversion (-DC conversion) dedicated (/60 z common) eat proof temperature 130 C Protection property symbols: IP65 or equivalent Perfect for places where beat can be a problem Outdoor use not available Lead wire Easy wiring Light available (optional - 100, 200 V only) Lead wire length 300 mm Conduit (CTC19) for direct conduit wiring can be mounted 4M 4N 5 with diode diode is mounted on the coil section for direct-current conversion (-DC conversion) dedicated (/60 z common) eat proof temperature 130 C Protection property symbols: IP21 or equivalent Perfect for places where beat can be a problem Outdoor use not available Easy wiring Light available (optional - 100, 200 V only) 5M 5N with diode diode is mounted on the coil section for direct-current conversion (-DC conversion) dedicated (/60 z common) eat proof temperature 130 C Protection property symbols: IP65 or equivalent Perfect for places where beat can be a problem Outdoor use not available Conduit Easy wiring Light available (optional - 100, 200 V only) Use a conduit (CTC19 or 1/2) when using direct conduit wiring for the open frame lead wire. 5I 5J *1 224 *1: Only DK1* is supported.

PK21/DK21 DC and eat proof temperature 130 C Protection property symbols: IP65 or equivalent Outdoor use not available Lead wire Lead wire length 300 mm Direct conduit wiring thread CTC19 integrated ppearance 3 NB/ USB/ FB/ FB/ DC and eat proof temperature 130 C Protection property symbols: IP21 or equivalent Outdoor use not available Easy wiring Light available (optional - 100, 200 V / 24, 100 VDC only) 3M 3N FVB FWB/ FB FLB Open frame type eat proof class taped with diode dedicated eat proof temperature 180 C igh temperature fluid and high ambient temperature available Protection property symbols: IP00 Outdoor use not available diode is mounted on the coil section for direct-current conversion (-DC conversion) dedicated (/60 z common) eat proof temperature 130 C Protection property symbols:ip65 or equivalent Perfect for places where beat can be a problem Outdoor use not available Lead wire Lead wire Lead wire length 300 mm Direct conduit wiring thread CTC19 integrated Easy wiring Light available (optional - 100, 200 V only) Lead wire length 300 mm Direct conduit wiring thread CTC19 integrated 4 4M 4N 5 B P/ D PK/ DK For dry air Explosion proof VB/ VL SB/ SVB NP/NP/ NVP CB/ MXB/ with diode diode is mounted on the coil section for direct-current conversion (-DC conversion) dedicated (/60 z common) eat proof temperature 130 C Protection property symbols:ip21 or equivalent Perfect for places where beat can be a problem Outdoor use not available Conduit Easy wiring Light available (optional - 100, 200 V only) Use a conduit (1/2) when using direct conduit wiring for the open frame lead wire. 5M 5N Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order 225 eneral purpose valve Pilot operated/pilot kick type 2 port solenoid valve

Safety precautions lways read this section before starting use. Pilot operated 2 port solenoid valve (P/D) and pilot kick type 2 port solenoid valve (PK/DK) 1 1 2 1 2 3 Design & Selection WRNIN Working fluid (1) When using this valve for dry air or inert gas, the life can be shortened considerably due to wear. Use a valve for dry air. (2) This valve cannot be used for maintaining the vacuum. CUTION Fluid viscosity The fluid viscosity must be mm 2 /s. Malfunctions could occur if the viscosity is higher than mm 2 /s. (This value is 20 mm 2 /s for the PK Series.) Leakage current from other fluid control components When operating the solenoid valve with CR circuit a programmable controller, etc., check that the output leakage current from the programmable controller is within the following specifications. Voltage Series no. P, D PK, DK Solenoid valve diode DC 100 V 200 V 100 V 200 V 12 V 24 V 6 m 6 m 3 m 3 m 2 m 2 m Triode switch Programmable controller side 1 m 1 m 2 m 2 m Installation, Piping & Wiring CUTION 1 m 1 m Installation (1) s a general rule, the valve must be installed vertically with the coil facing upward. Piping (1) If the pipe vibrates when the solenoid valve is opened and closed, securely fix the piping. (2) When passing steam, steam generated from a boiler will contain a large amount of drainage. lways install a drain trap. (3) When passing steam, water replenished to the boiler will contain matters such as "calcium salt" and "magnesium salt". These matters will react with oxygen and carbon oxide causing scales and sludge, so always install a "water softener" and a filter for steam. (4) When the regulator and solenoid valve are directly coupled, the parts could mutually vibrate causing resonance and chattering. (5) If the piping cross-section area on the fluid inlet is reduced, the operation may become unstable due to a differential pressure fault during valve operation. The piping on the fluid inlet must have a size that matches the valve port size. Wiring (1) Refer to page 53 in the Introduction for details on connecting the terminal box. C R Leakage current CUTION When Using 1 Instantaneous leakage With the pilot operated type or pilot kick type 2 port valve, if sudden pressure is applied when the pump starts while the valve is closed, the valve may open for an instant causing fluid to leak. Caution is required during use. 2 Operation Do not apply back pressure. The valve could malfunction. 3 Water hammer If water hammering occurs causing a problem, consider using the CKD "WL type" or "RSV type" solenoid valve or a motor valve. 4 Manual operation lways observe the following points when using a manual override. <For NO (normally open) type> Opening: Insert a flat-tip screwdriver into the slit on the manual shaft, and turn it approx. 120 to the right or left. The plunger will rise up, and the valve will open. The open state is held even when the screwdriver is removed. lways return the valve to the original position after use. Closing: Turn the manual shaft from the open position to the vertical position. The plunger will lower and the valve will close. (Refer to the following drawings.) C O Valve closed O C Valve opened <For NO (normally open) type> (1) Closing the valve with manual operations The manual shaft is threaded, so hold the manual dial and rotate the shaft clockwise. When the manual dial has been rotated downward 5 to 6 mm and no longer rotates, the solenoid valve will switch to closing operation. (2) Resetting (when not using manual override) lways rotate the manual dial counterclockwise and return it to the highest point. Manual dial Manual shaft Right-handed thread C O Valve opened 226

1 2 2 CUTION Maintenance Thermal insulation cover When piping for steam or hot water, etc., use an insulating cover structure that can be disassembled for maintenance purposes. void placing an insulating cover on the entire solenoid valve or on the coil section. The coil could burn. Tightening torque When disassembling or assembling, tighten the body bolt, core assembly and nut with the following tightening torques. NB/ USB/ FB/ FB/ FVB FWB/ FB P 12 11 D 12 PK11 11 DK P D 11 12 21 22 21 22 PK21 DK21 8 10 15 20 25 32 40 32 40 F F F F F F CUTION Body bolt tightening torque 3 to 4 N m 5 to 7 N m 9 to 12 N m 18 to 28 N m Core assembly tightening torque 30 to 45 N m 45 to 60 N m for PK11-15 to 25 80 to 120 N m Working Environment Nut tightening torque 8 to 16 N m IP65 (IEC60529 (IEC529:1989-11)) standards are applied to the test. void use in conditions where water or cutting oil directly contacts the valve. Explanation of protection property symbols and examination method of IP65 Protective structure Note: IP-65 is a standard as followings. IEC (International Electrotechnical Commission) standards IP-** 1st characteristic number (protection grade for foreign solid) rade 6 Degree of protection Dust proof type Powder and dust do not enter inside. Protection property symbols (International Protection) 2nd characteristic number (protection grade for entry of water) rade 5 Degree of protection Protection for jet No harmful effects occur even when water is sprayed with nozzles from all directions. (IEC60529 (IEC529:1989-11)) Overview of test method (fresh water is used) Using the following test device, spray water for 1 minute per 1 m 2 of test sample (exterior) surface area from all directions, for a total of 3 minutes or more. 2.5 to 3 m 12.5 L/min. Spray nozzle inner diameter: ø6.3 mm 227 FLB B P/ D PK/ DK For dry air Explosion proof VB/ VL SB/ SVB NP/NP/ NVP CB/ MXB/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve Pilot operated/pilot kick type 2 port solenoid valve