Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions

Similar documents
Sentinel Field Satellite Controller

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

OBE-3-FT Outdoor Series

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

NEC 2011 Code Changes

STAINLESS STEEL AUTOMATIC CONTROLLER ENCLOSURE ASSEMBLY. SEE IRRIGATION LEGEND FOR MAKE AND MODEL. 2

E.S.P. Embedded Sensing Probes for Motor Brushes

UNDERGROUND SERVICES - SECONDARY

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

NEC 2014 Code Changes

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present

Section 02: Pre-Installation Procedures

FieldSmart Fiber Active Cabinet (FAC) 3200 Installation Manual

Installation Manual. Rev

GROUNDING & BONDING PRODUCTS

Sunwize Power Ready Express Quick Start

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

Grounding Systems. Equipment Grounding & Grounded Conductors

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

OBE-3 Outdoor Series

Earthing UNIT. Learning Objectives. Introduction. To understand purpose of Earthing. To learn system of earthing.

Approved Contractor Construction e-guide Residential Commercial

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

Have You Been Grounded Lately

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

AMENDMENT ELECTRIC SERVICE MANUAL 2014

7. Residential Single-Family and Duplex Buildings (Dwellings)

Cabinet and Rack Installation

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

MODEL SIT -6E PAVEMENT-MOUNTED SNOW AND ICE SENSOR

AW70V6 70V Surface Mount Indoor/Outdoor Speakers Installation Manual

Table of Contents. Electrical Service Requirements. 1. General Requirements

Cabinet and Rack Installation

ELECTRO-MECH SCOREBOARD CO.

34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE

Installation Instructions Studio Makeup Station

Generator Fire Safety: Generator assemblies should be located outside the building.

RAIN BIRD - AQUAGATOR AQUAGATOR INSTALLATION & TROUBLESHOOTING MANUAL

CommScope MULTILAYERED 289-TYPE INSTALLATION INSTRUCTIONS

12 STATION MANUAL CONTROLLER INSTALLATION AND OPERATING GUIDE MODEL HRM-12

CHAPTER V RESIDENTIAL WIRING

5. Underground Requirements

G-170. r ve Pickup Lift Mounting Instructions Fullsize Chevy & GMC Trucks- 1500, 2500 & 3500: 2007-present

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes

Clearfield ODC-2000 Installation Guide

and Original Series Pickup Lift Mounting Instructions Fleetside Chevy & GMC Trucks Fleetside 4-door Chevy & GMC Trucks T-100

Electric Range installation manual

IMPORTANT SAFEGUARDS

Cantilever Series Mounting Instructions Fullsize Sprinter Van (US) WB (AB) present

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

Installing Power Components

Environmental Distribution Center (EDC-06P-NH)

Pavement-Mounted Deicing Controller SNOW SWITCH MODEL HSC 24. Installation and Operation Manual

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

SELF DRILL SCREWS FILLER STRIP

INSTALL SERVICE- ENTRANCE SYSTEMS

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

7 Single Family Service

2904 Power Supply Installation Instructions I-EA00041

Outdoor Power Transmission & Distribution

Instruction Sheet. Subject: Installations Instructions. Air Compressor Kits. Importan

2-row and All-row systems included.

MODEL HSC-24 AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

SPECIFICATIONS FOR COMMERCIAL CONSTRUCTION

5. Contractor Information 3M Model 2300 Series System Layout Checklist

and Original Series Pickup Lift Mounting Instructions Fullsize Nissan Titan Trucks present T-420 BOLT-ON GUSSET PART#5257

and Original Series Pickup Lift Mounting Instructions Fullsize Chevy & GMC Trucks: 1500 & 2500 LD HD & 3500HD BOLT-ON GUSSET

Installation Instructions: HYPERION R-Lite SYSTEM

Nanometrics Solar Power System

Fabric Studio Custom Roll Shades Installation Instructions

Apollo Solar Inverter Switchgear Module Installation Manual Rev 1.2 Page 1

WPS-2800 SERIES HIGH POWER VOICE & SIREN SYSTEM

Snow Switch Models HSC 4 (P/N 24220) & HSC 5 (P/N 24221)

Australian Wiring Instructions:

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

UNDERGROUND SERVICE. Items to consider. There will be charges from ComEd if you convert from overhead to underground service.

Q-VAULT Installation Instructions. Q-Tran, Inc. Milford, CT

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L

Installation Instructions: ACCENT SYSTEM

Access Riser Fits PRO370 and PRO380 Series

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

SunWize SWPB Series Solar Modules GENERAL INSTALLATION & USER GUIDE

P Original Series Cargo Van Lift Mounting Instructions Fullsize Ford Van present. Preparing the Gate

SPRINGVILLE CITY ELECTRICAL REQUIREMENTS & STANDARDS MANUAL

GENERAL INSTALLATION MANUAL

INSTALLATION GUIDE. For Carrier/Bryant Residential Power Systems

A-dec 541 Delivery System and 545 Assistant s Instrumentation

Photoelectric. Sensors Invisible Light Beam Protection Area

WeatherTRAK FlowLink Installation Instructions 04/23/2013 Revision 2 HydroPoint Customer Support

and Original Series Pickup Lift Mounting Instructions T-150-T T-150 PART#5177 T-150-T

accqpulse Velocity Profiler Sensor Installation Guide

Safety and Installation Instructions For Fluitecnik PV Modules

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

Catalog & Wiring. splice. irrigation. grounding systems. landscapelighting

SITRANS F. Ultrasonic Flowmeters. Hi-Precision Mounts. Operating Instructions. Answers for industry.

Transcription:

WARNING HIGH VOLTAGE 115V 4 M AP Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions Important: For your protection and the safety of the product user, please comply with all Caution and Warning statements within this document. All installation practices must comply with all applicable national and/or local electrical and building codes and be performed by qualified personnel only. Introduction The metal or plastic pedestal-mount satellite controller unit is designed for installation on a substantial concrete pad with embedded conduit of various diameters to enable wiring connections for power, field, earth ground, sensor and optional external antenna. Pedestal anchor bolts and a steel bolt pattern template are supplied with the controller. The wall-mount satellite unit is designed for installation on a structurally-sound building wall. The stainless steel cabinet is moisture resistant and suitable for outdoor installation. The cabinet has upper and lower support attachments and is supplied with a mounting bracket which attaches directly to the wall. Refer to wall mount installation procedures on page 2. Additional materials required to complete the installation must be obtained separately. A material list can be compiled by reading through the instructions completely prior to starting the installation. Metal Pedestal Installation 1. Prepare a hole for the pad and wiring conduit using the minimum recommended dimensions shown in Figure 1. This size pad requires approximately 4cu ft (122cu cm) of concrete. * Refer to local electrical codes for the required wire burial depth. 2. Position straight and sweep elbow conduit sections in foundation hole as shown. Placing the controller toward the back of the pad as shown protects the ground near the front of the controller from wear. 3. Tape the conduit ends to seal out dirt. Backfill soil to form a 6 (15cm) foundation depth. The conduit should not extend more than 2 (51mm) above the finished top surface of the foundation. 4. Form the perimeter of the pad area using 2 x 6 boards or 3/4 (19mm) plywood. 5. Prepare the mounting bolt template with the provided L-shaped bolts and hex nuts as shown in Figure 1. 6. Pour concrete into the formed area and trowel smooth. Finish the concrete pad with a level flat area for the pedestal base approximately 8 x 17 (20cm x 43cm). 7. Aligning the mounting bolt template with the conduit, press the L-shaped bolts into the concrete until the template makes contact. To prevent pooling at the base of the pedestal, add a slight taper away from the template. Allow the concrete to sufficiently harden before continuing. Figure 1 6 (15.2mm) 1/2 (13mm) Conduit for Earth Ground 3/4 (20mm) Conduit for Input Power Wiring 2 (50mm) Conduit for Field Wiring (12 24 Stations) 1 1/4 (32mm) Conduit for External Antenna Cable (Optional) 2 (50mm) Conduit for Field Wiring (25 48 Stations) 1/2 (15mm) Conduit for Sensor Wires (Optional) Wood Form 8. Remove the mounting bolt hex nuts. Remove and discard the mounting bolt template. Place the pedestal on the pad ensuring all bolts are inserted into the pedestal base. Install a flat washer and a hex nut on each bolt and tighten securely. Taper See *Note Mounting Bolt Template - Cabinet Base Area 8 x 17 (20.3cm x 43.2cm) 29 (73.7cm) Mounting Bolt Template 36 (91cm) Mounting Bolts w/hex Nuts (Typical Four Places) 2 (51mm) 6 (15cm)

Plastic Pedestal Installation 1. Prepare a hole for the foundation and wiring conduit using the minimum recommended dimensions shown in Figure 2. * Refer to local electrical codes for required wire burial depth. Figure 2 Wood Form Plastic Cabinet Base Area 2. Trench to the foundation site as required for each wiring run. 3. Position straight and sweep elbow conduit sections in foundation hole as shown. Tape the conduit ends to seal out dirt. Backfill soil to form a 6 (15.2cm) foundation depth. Conduit should not extend more than 2 (51mm) above the finished top surface of the foundation. 4. Prepare the sides of the foundation hole with wood forms. 5. Prepare the mounting bolt positioner with the 5/16 x 4-1/2 bolts and nuts (provided) as shown in Figure 2. The threads should extend 2 (51mm) from the top surface of the bolt positioner. 6. Pour concrete into the formed foundation hole. Press the mounting bolt positioner into the concrete until it is flush and level with the foundation surface and aligned with the conduit. Conduit Recommendations 4 (10cm) - Field Stations 1 1/2 (40mm) - External Antenna (Optional) 3/4 (20mm) - Earth Ground 3/4 (20mm) - Power Supply 2 (50mm) Maximum Mounting Bolt Positioner 6 (15cm) 2 (50mm) 30 (76cm) 30 (76cm) Taper See *Note 7. Finish the concrete with a level flat area of 16 x 16 (41cm x 41cm) for the pedestal base. To prevent pooling at the base of the pedestal, add a slight taper away from the cabinet base contact area. Allow concrete to sufficiently harden before continuing. 8. Remove the hex nuts from the mounting studs. Remove the cabinet cover and doors. Carefully position the controller onto the studs. Install a flat washer and a hex nut on each stud and tighten securely.

WARNING HIGH VOLTAGE 115V 4 M AP PROGRAMMING INSTRUCTIONS OFF ON ESC ON YES CLUSTER / SCHEDULE SELECT PROGRAM SELECT ENTER Wall-Mount Cabinet Installation 1. Position the upper support bracket on the wall with the joggle edge up to accept the mating upper cabinet bracket. The support bracket must be level and at a height approximately 2 (51mm) above eye level to enable the Sentinel control module display to be easily viewed. 2. Mark the two mounting screw hole locations and drill pilot holes for the screws or screw anchors. Use 3/8 (10mm) diameter fasteners to attach the cabinet support brackets. If installing the cabinet on dry wall or masonry, install the appropriate size and type screw anchors. 3. Secure the support bracket to the wall. Hang the cabinet on the wall by engaging the upper cabinet bracket and the support bracket. 4. Draw a pencil line the entire length of the lower support bracket. 5. Remove the cabinet from the wall and remove the lower support bracket from the cabinet. 6. Place the lower support bracket on the wall aligning it with the pencil mark. 7. Mark the two screw hole locations and drill pilot holes for the mounting screws or screw anchors. 8. Secure the bottom support bracket to the wall. * On early model cabinets, conduit access holes are only provided for power and one field wire conduit. Additional conduit access holes for earth ground, additional field wire conduit, optional sensor wires and optional external antenna must be cut or punched by the installer. All conduit access holes and knock-outs are provided on current production cabinets. 9. Remove optional conduit knock-outs as required for installation. See *Note above. 10. Hang the cabinet on the wall mount support bracket. The bottom edge of the cabinet should now rest squarely on the lower support bracket. 11. Secure the cabinet to the lower support bracket using the carriage bolts and nuts removed in Step 5 above. 12. Install electrical conduit for all wiring connections per local and national code. See Figure 4. Figure 3 Figure 4 3/4 (20mm) Conduit for Power Wires 1/2 (15mm) Conduit for Earth Ground Screw Anchors 1 2 3 F1 4 5 6 7 8 9 0 F2 F3 F4 Upper Cabinet Bracket Upper Support Bracket Lower Support Bracket 1/2 (15mm) Conduit for Sensor Wires (Optional) 2 (50mm) Conduit for Field Wiring (25 48 Stations) 2 (50mm) Conduit for Field Wiring (12 24 Stations) 1 1/2 (40mm) Conduit for External Antenna (Optional)

Earth Ground Installation IMPORTANT! The TDC surge protection components cannot properly function unless an efficient pathway to earth ground is provided. The ground path must be as direct as possible, without sharp bends and must not exceed 30 Ohm resistance (when measured with an earth ground resistance device). All electrical components throughout the irrigation system should be grounded similarly to provide the same ground potential. The following instructions depict one of several acceptable earth grounding methods. Due to variables in soil composition and terrain, the method shown may not be suitable for your installation site. Contact your local Toro distributor for assistance and availability of the required earth ground resistance test instrument. Step 1 Step 2 Step 3 Drive a 5/8" x 8' (17mm x 2.5m) copper-clad steel rod into well moistened soil not less than 8' (2.5m) or not more than 12' (3.7m) from the controller cabinet. The top of the ground rod should be 12" (30.5cm) below grade level. See Figure 2. Using a 5/8" (17mm) clamp or Cad weld fastener, attach an 8 AWG (8mm 2 ) solid copper wire near the top of the ground rod. Avoiding wire bends of less than 8" (20.3cm) radius and more than 90 o, route the wire through conduit and into the cabinet. Secure the wire to the copper ground lug. Make sure the soil surrounding the ground rod(s) remains well moistened at all times. The addition of some form of irrigation may be required if the cabinet is installed in a non-irrigated location. Measure the ground resistance per the instructions provided with the ground test instrument. A reading of 0.0 Ohm is optimum, up to 10 Ohm is good and 11 30 Ohm is acceptable in most cases. If the resistance exceeds the acceptable limit, additional ground rod(s) can be installed at a distance equal to twice the buried depth of the first rod; i.e., 16' (4.9m). Interconnect the ground rods using 8 AWG (8mm 2 ) solid copper wire and test again. If the measured ground resistance continues to read above the acceptable limit, contact your local Toro distributor for further assistance and recommendations. Installing a round valve box over the ground rod enables the ground rod to be easily located as well as providing access to the ground wire connection(s). Figure 2 Ground Lug Valve Box 8 AWG (8mm 2 ) Solid Copper Ground Wire 12" (30.5cm) 8" (20.3cm) Minimum Radius Ground Wire To Additional Rod(s) (Optional) 8' 12' (2.4m 3.7m) Copper Clad Ground Rod 90 o Minimum Angle

Power Source Installation WARNING! AC POWER WIRING MUST BE INSTALLED AND CONNECTED BY QUALIFIED PERSONNEL ONLY. ALL ELECTRICAL COMPONENTS AND INSTALLATION PROCEDURES MUST COMPLY WITH ALL APPLICABLE LOCAL AND NATIONAL ELECTRICAL CODES. SOME CODES MAY REQUIRE A MEANS OF DISCONNECTION FROM THE AC POWER SOURCE, INSTALLED IN THE FIXED WIRING, HAVING A CONTACT SEPARATION OF AT LEAST 3mm IN THE LINE AND NEUTRAL POLES. ENSURE THE AC POWER SOURCE IS OFF PRIOR TO SERVICING. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY DUE TO ELECTRICAL SHOCK HAZARD. Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Turn off the power at the power source location and place the controller s power switch to OFF. Connect and route the appropriate size 3-conductor cable (10 AWG [2.5mm 2 ] maximum) from the power source to the controller cabinet. The provided power cable access hole can accommodate a 1" (25mm) conduit fitting. If conduit is required, install a section of flexible 1" (25mm) electrical conduit from the power source conduit box to the cabinet s access hole. Open the cabinet door and remove the two retaining screws from the power supply cover. Locate the voltage cable assembly and note the voltage on the label. The TDC is equipped with 120V cable assembly from the factory. Replace the voltage cable assembly with the proper rating as necessary. See Figure 3. Strip the power cables and secure them to the terminal block. Reference Table 1 for the appropriate type of power connection. Reinstall the power supply cover. Apply power to the controller. Flexible Conduit (Optional) Voltage Cable Assembly Figure 3 Line Neutral Equipment Ground

Station Decoder Installation The station decoder module is available in 1-station, 2-station or 4-station configuration. The decoder modules are installed into the TDC output board terminals. The stand-alone TDC model can handle up to 100 stations per output board. These stations can be connected to the output board terminals in any configuration (25 stations connected to each of the four terminal pairs or 100 stations connected to one terminal pair, etc.). The decoder modules can be connected in parallel anywhere on the two-wire communication line connected to the station terminals. Each station can activate up to two solenoids. It is recommended that the decoder modules are installed in an approved valve box to provide easy access to the wiring. Use high-voltage waterproofing to all the wire connections. Recommended Controller-to-Decoder cable: 14 AWG (2.5mm 2 ), solid copper, jacketed 2-conductor, direct burial. The preferred wire make and model is the Paige Irrigation Wire, Spec P7350D. Recommended Decoder-to-Solenoid cable: 14 AWG (2.5mm 2 ), solid copper, 2-conductor, direct burial. The preferred wire make and model is the Paige Irrigation Wire, Spec P7351D. IMPORTANT! Cable Splices: In order for the wire connections to comply with the 2005 edition of the National Electric Code Article 300.5 (Underground Installations) and 110.14 (Electrical Connections), in wet or damp locations, the connector must be listed under specification UL 486D if installed in a valve box. It must be listed under specification UL 486D- Direct Burial if buried in dirt. This requirement applies to all electrical connections in wet or damp locations, regardless of voltage. The 3M DBY-6 and DBR-6 are listed as UL 486D-Direct Burial and meet these requirements for all underground installations. Cable Burial Depth: The TDC decoder operate at voltages between 30 40 volts. The 2005 edition of the National Electrical Code, Article 300-5, requires that wires and cables subjected to voltages higher than 30 volts are to have a minimum cover of 24" (60.96 cm). Use only wire approved for direct burial if installing the wires underground without conduit. All field wiring splices must be accessible to facilitate troubleshooting and/or service. Step 1 Route communication cable from the controller to the station decoder module installation location. The maximum wire length between the controller and the decoder module is 15,000' (4500m). Step 2 Secure the communication wires to terminal 1 of the TDC output board. White wire onto the 1st terminal and black wire onto the second terminal. See Figure 4. Step 3 Install the decoder module in a valve box. Record the decoder module s address number found on the side label. This address number identifies the station(s) that the decoder module control. Step 4 Secure the communication wires to the decoder module s black and white wires. Connect the black communication wire to the black decoder module wire. Connect the remaining communication wire (red or white) to the white decoder module wire. Use proper water proofing method for all wire connections. Step 5 Route output wires from the decoder module to the solenoid. The maximum wire length between the decoder module and the solenoid is 410' (125m). Step 6 Connect the solenoid wires to the decoder module s station wires. The station wires are color coded for easy identification. Connect the solid colored (red, green, orange or blue) station wire to the red/white solenoid wire. Connect the similar color station wire with black stripe to the black solenoid wire. Waterproof all wire connections. Step 7 Connect an additional solenoid to the station wire as necessary. Each station has a maximum load of two solenoids. Step 8 Repeat Steps 3 8 for additional decoder modules.

Figure 4 DC Latching Solenoid Red White Power/Communication Wire Power/Communication Wire Station 1 Solid Red Station Wire - Connect to the Red/White solenoid wire Red with Stripe Station Wire - Connect to the solenoid wire Station 2 Solid Green Station Wire - Connect to the Red/White solenoid wire Green with Stripe Station Wire - Connect to the solenoid wire Station 3 Solid Orange Station Wire - Connect to the Red/White solenoid wire Orange with Stripe Station Wire - Connect to the solenoid wire Station 4 Solid Blue Station Wire - Connect to the Red/White solenoid wire Blue with Stripe Station Wire - Connect to the solenoid wire Each station can activate up to two DC Latching Solenoids. 1-Station Decoder Module Output Board Station Wires The Stand-Alone TDC output board can accommodate up to 100 stations. The decoder modules can be connected in any configuration using the four station terminals. Out to additional decoder modules White White White White Paths 1 2 3 4 Valve Box The maximum communication wire length between the decoder module and the solenoid is 410ft (125m). Recommended Cable for Decoder-to-Solenoid is the Paige P7351D, 14 AWG, Solid Copper, 2-Conductor, Direct Burial cable. To easily identify stations for troubleshooting, install wires with the same color code as the station wires. When possible, install the decoder module in a valve box for ease of service. Maximum communication wire length between the controller and the farthest decoder is 15,000ft (4500m). Recommended Cable for Controller-to-Decoder is the Paige P7350D, 14 AWG, Solid Copper, Jacketed 2-Conductor, Direct Burial cable.

Grounding Communication Cable IMPORTANT! Cable Splices: In order for the wire connections to comply with the 2005 edition of the National Electric Code Article 300.5 (Underground Installations) and 110.14 (Electrical Connections), in wet or damp locations, the connector must be listed under specification UL 486D if installed in a valve box. It must be listed under specification UL 486D- Direct Burial if buried in dirt. This requirement applies to all electrical connections in wet or damp locations, regardless of voltage. The 3M DBY-6 and DBR-6 are listed as UL 486D-Direct Burial and meet these requirements for all underground installations. Cable Burial Depth: The TDC decoder operate at voltages between 30 40 volts. The 2005 edition of the National Electrical Code, Article 300-5, requires that wires and cables subjected to voltages higher than 30 volts are to have a minimum cover of 24" (60.96 cm). The optional lightning arrester (Toro P/N DEC-SG-LINE) is available to protect the decoder module in lightning prone areas. Without lightning arrester, the decoder are vulnerable to lightning damage. In order for these arrester to discharge lightning energy efficiently, they must be properly grounded. Figure 5 illustrates the proper grounding and wiring of the arrester. Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Locate decoder s power/communication wires (black and white wires). Disconnect the wire connectors that joins it to the controller-to-decoder cable. Strip the insulation from lightning arrester s white wire and connect it to the white wires from the decoder and controller-to-decoder cable. Secure the splices with a water proofed wire connector. (See Figure 5.) Strip the insulation from lightning arrester s black wire and connect it to the black wires from the decoder and controller-to-decoder cable. Secure the splices with a water proofed wire connector. (See Figure 5.) Connect the lightning arrester s ground wire to the ground plate s wire. If the ground plate is not pre-wired, use a 10 AWG bare copper wire. (See Figure 5.) IMPORTANT! Verify that the wire length between the lightning arrester and the ground plate is no less than 3' (91.44 cm). Longer lengths will decrease the lightning arrester s effectiveness. Bury the Ground plate next to the valve box or decoder s location. Set it at the maximum depth that the ground wire would allow. Surround the ground plate with 50 lbs (2.68 Kg) of Earth contact material such as PowerSet (Paige Electric, part number 1820058). Check the system for proper operation. Figure 5 Use Paige P7351D for Decoder-to-Solenoid Communication Wiring Toro Decoder Module Paige P7350D Controller-to-Decoder Communication Cable Lightning Arrester Toro P/N DEC-SG-LINE 4'' x 36'' (10.16 cm x 91.44 cm) Ground Plate - Surrounded by 50 lbs (2.68 Kg) of PowerSet 3' (91.4 cm) Minimum Distance Between the Arrester and the Ground Plate