Kämmer Multi-Z Severe Service Valves

Similar documents
flowserve.com Kämmer Multi-Z Kämmer Multi-Z Severe Service Valves

Kämmer Series Low Flow Valves

Kämmer Series Low Flow Valve

Kämmer Series Split Body Valves

Desuperheater FCD VLENTB /11. Experience In Motion

TECHNICAL BULLETIN. Valtek Multi-Z Anti-Cavitation Control Valve. Experience In Motion. Valtek Series Multi-Z FCD VLENTB /10

Vogt Valves The Connection Bulletin for Forged Steel Globe Valves for Water-Free Chlorine Service Class 300, 600 & 800 CB 07

Experience In Motion. Flowserve Control Valve Products North American Quick Response Centers

Vogt Valves The Connection Bulletin for Y Pattern Globe & Check Valves Class 1690 & Class 2680 CB 18

TECHNICAL BULLETIN. NAF Setball SF Ball Sector Valves. Experience In Motion. flowserve.com. NAF Setball FCD NFENTB A4 02/16

Valtek Flow Boosters

USER INSTRUCTIONS. Valtek Control Products Spring Cylinder Linear Actuators. Installation Operation Maintenance. Experience In Motion

Mark 100. Technical Bulletin F C D F C A T B

TECHNICAL BULLETIN. Valdisk TX3 Triple Offset Butterfly Control Valve. Experience In Motion FCD VLENTB A4 1/16

TECHNICAL BULLETIN. NAF Trunnball DL Ball Valves. Experience in Motion FCD NFENTB A4 09/14

TECHNICAL BULLETIN. Audco Ball Valve. Reduced Bore Fire safe Flanged Ball Valves 51/52 Series. Experience In Motion

Valtek MaxFlo Control Valves

NAF Duball DL Pocket Ball Valves TECHNICAL BULLETIN FCD NFENTB A4 11/17

MARPAC K SERIES. Full Bore Fire Safe Flanged Ball Valves

Valtek Tek-Check. Check Valves

Valtek Tek-Check Control Valves Valtek Tek-Check

Valtek Valdisk 150. Valtek Valdisk 150. Control Valves. Flowserve Corporation, Valtek Control Products, Tel. USA

TECHNICAL BULLETIN. NAF Duball DL Ball Valves. Experience in Motion FCD NFENTB A4 12/14

flowserve.com Flowserve Solenoid Valves Namur, Remote and Banjo Mounted Designs for Precision Control

flowserve.com Valtek ShearStream Segmented Ball Valve Series

WORCESTER CONTROLS F519/529/819/829. Full Bore Fire Safe Flanged Ball Valves

Logix 3800 Digital Positioner

Edward. Equiwedge Forged Gate Valvee. Experience In Motion

flowserve.com Limitorque LRP Limitorque Rack & Pinion Pneumatic Actuator

Valtek Spring Cylinder Linear Actuators

USER INSTRUCTIONS. Spring Diaphragm Rotary Actuators. Installation Operation Maintenance. Experience In Motion FCD VLAIM /12

Flowserve Spring Diaphragm Rotary Actuators

S-17 CATALOG. Forged Steel Strainers

Installation Instructions

ISC Series Innovative Standard Cartridge Seals

Valtek XL Series High Performance Positioner. for Control Valves

Installation Instructions

Valtek Beta Positioner. Valtek Beta Positioners. for Control Valves

Worcester Controls Directional Ball Valves

Logix 3800 Digital Positioner

Limitorque Actuation Systems PT Series Worm Gear Operator

USER INSTRUCTIONS. Limitorque TM V Series. Installation Operation Maintenance. Experience In Motion FCD LMENIM AQ 02/15

Installation Instructions

USER INSTRUCTIONS. Installation Operation Maintenance. NAF Setball SF Ball Sector Valves. Experience In Motion FCD NFENIM A4 09/16

USER INSTRUCTIONS. Valtek Valdisk TX3 Triple Offset Butterfly Control Valve. Installation Operation Maintenance. Experience In Motion

Installation Instructions

Limitorque Actuation Systems B320 Series. Rugged and dependable bevel gear operators for manual or motorized valve control applications

TECHNICAL BULLETIN. Valtek GS. General Service Control Valve FCD VLENTB0300A4 03/14

Flowserve Anchor Darling Isolation Valve Application

Installation Instructions

flowserve.com Kämmer SmallFlow Low and Micro Flow Valves

Installation Instructions

TECHNICAL BULLETIN. Valtek GS. General Service Control Valve FCD VLENTB0300AQ 03/13

Kämmer Series Multi-Z FCD KMENTB /16 TECHNICAL BULLETIN. Kämmer Multi-Z Severe Service Valves FCD KMENTB /16. Experience In Motion

Limitorque Accutronic MX/WTR Performance and Dimensions. Limitorque Actuation Systems

TECHNICAL BULLETIN. Logix 505si Series Digital Positioner. Experience In Motion FCD LGENTB /13

USER INSTRUCTIONS. NAF Trunnball DL Ball Valves. Installation Operation Maintenance. Experience In Motion FCD NFENIM A4 01/15

INSTRUCTION MANUAL. Anchor Darling 1878 Swing Check Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

Rotary Valve Maxflo + 60 and 80 Opening type NT

Valtek Valdisk 150. Valtek Valdisk 150. Control Valves

Installation Instructions

Limitorque. HBC Series Worm gear operators proven in the most demanding situations

TECHNICAL BULLETIN. Valtek MaxFlo 4. Eccentric Rotary Plug Control Valve. Experience in Motion FCD VLENTB AQ 9/16

TECHNICAL BULLETIN. Segmented V-port Ball Valves. Experience In Motion FCD VLENTB

Installation Instructions

Limitorque HBC Series Worm Gear Operators

PMV. P5 Pneumatic Positioner. Product Information

Solenoid Block Kit for Series 90 Modular Accessory System Installation, Operation and Maintenance Instructions

EDELSTAHL a. Flow Control Division. Kammer Control Valves. Kämmer Series Kämmer Series Aseptic and Sanitary Valves

RVX Upgrade. ISO 13709/API 610 back pullout retrofit. Experience In Motion

Installation Instructions

Installation Instructions

General Stem-Guided Control Valves

flowserve.com Durco PlugSeal Valve ASME Class 600 Plug Valves Serving the Worldwide Desalination Industry Experience In Motion

TECHNICAL BULLETIN. Valtek MaxFlo 4. Eccentric Rotary Plug Control Valve. Experience in Motion FCD VLENTB AQ 11/15

General Stem-Guided Control Valves

Valtek VL-HC Spring Cylinder Linear Actuators

Flow Control Division. Kammer Control Valves. Kämmer Series Corrosive Application Valves

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

Accord DS/DM Series UltraSwitch Switch box

Pleuger PMM. High-Efficiency Submersible Motor With Permanent Magnet Technology for Electrical Submersible Pumps (ESP) Experience In Motion

Kämmer Series Corrosive Application Valves

Tri-Pac E325 / E525 Ball Valve Three-Piece Bolted Body, In-Line Maintainable, Regular and Full Port. McCANNA/MARPAC Valves RO400-R4

E818/828 Series Fugitive Emissions 150# and 300# Flanged 2" - 8" Two-Piece Ball Valves Installation, Operation and Maintenance Instructions

Plug Valve Solutions for the Upstream Exploration and Production Pipelines Production manifolds, test manifolds and other dirty services

Installation Instructions

McCANNA Actuation Systems B

Product Specification

TECHNICAL BULLETIN. Valtek ShearStream SB Control Valves. Segmented V-port Ball Valves. Experience In Motion VLEETB

CONNECTION BULLETIN. Vogt Valves. Experience In Motion. Zero Leakage Forged Steel Check Valves Class 800. FCD VVABR /04 (Replaces CB-03)

High Pressure Valves Series Angle Valves Series Angle Valves

Flow Control Division

Valtek GS The Perfect Balance

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /13

Series 72 Electri-SAFE On/Off Operation Including CLC Option Installation, Operation and Maintenance Instructions

Installation Instructions

SPECIFICATIONS. Limitorque MX. Selection Data. Experience In Motion. Performance and Dimensions for MX Series 05 through 150 Electric Actuators

Valtek Survivor Control Valves

USER INSTRUCTIONS. Limitorque HBC Series. Installation Operation Maintenance. Experience In Motion FCD LMENIM A4 (10/14)

EDELSTAHL. Kämmer Series Aseptic and Sanitary Valves

Transcription:

flowserve.com Käer Multi-Z Severe Service Valves

Käer Multi-Z Introduction and cavitation completely under control Users from the power generation, petrochemical and industrial chemicals industries are frequently confronted with extreme pressure differentials in their process systems - differentials of up to 400 bar are not rare. Nevertheless, or rather precisely for this reason these customers desire continuous, harmonious, steady-state curves with appropriate flow characteristics, long and uniform service life, as well as low maintenance costs. The valves to be implemented must satisfy certain prerequisites, such as accoodating solids in liquid media, and prerequisites relative to high sound levels, high temperatures, cavitation formation, and corrosion. Now Flowserve Essen GmbH offers solutions with an interesting technological new development. Type Multi-Z valves are used if solids are entrained in the medium and if there is a possibility of cavitation forming. In addition this multiple stage valve is capable of reducing high-pressure differentials via a multiple stage relief process. Flowserve reduces pressure via division in partitions - a course which is different to that pursued by other suppliers. The major advantage is a noticeable reduction in wear combined with an extremely low-noise control valve. Likewise deviating from conventional procedures, in order to avoid cavitation a physically optimized technology has been implemented that achieves significantly better results. The valves are configured on the basis of customer specification so that the valve is optimally tailored to the special operating conditions. In this regard we do not rely on standard values, rather specially matched seat-plug fittings are used in each case. The individual stages of the plug are configured in such a manner that cavitation is impossible. Through the appropriate design of transitions and passages in the plug, solids in the process can be safely managed without destroying the fittings or the valve. The design of the linear / equal percentage multi-stage plug plug results in a greater rangeability and outstanding control characteristics for the installed strokes.

flowserve.com Features Eliminates cavitation Reduces sound level Tolerates solids in the process High rangeability Custom characteristics possible Seat is protected from high velocity, cavitation or flashing Variety of actuators: Pneumatic cylinder Pneumatic diaphragm Electric Hydraulic Available as unbalanced or pressure balanced Figure 1: Multi-Z Features

Applications Ideal for high-pressure drop applications in chemical, petrochemical and power. The Multi-Z is specifically designed to handle high-pressure drops where entrained solids are a problem, and is tested and certified for pump compatibility. Ideal for applications in chemical, petrochemical and power with pressure differentials of up to 5880 psi (400 bar), such as system start-up and boiler feed-water recirculation, the Multi-Z features a multistage trim design that eliminates cavitation and provides extended trim life. The addition of a unique venturi outlet nozzle provides further trim and seat protection from high velocity, cavitation and flashing. The Multi-Z linear multistage plug design provides high rangeability and throttling resolution, and dramatically reduces noise. Trim designs are available as unbalanced or pressure-balanced, with the number of stages optimised for specific service conditions. The Multi-Z is offered in nominal standard diameters of 1 to 6 es (DN25 to DN150) - in special applications up to 16 es (DN300) - and in pressure classes from ANSI 300 to ANSI 2500 (PN40 to PN400). These pressure classes enable the Multi-Z to operate within a maximum pressure drop of 5880 to 15 psi (400 to 1 bar). The Multi-Z body is available in angle configurations, and in a choice of carbon steel, stainless steel, nickel-based alloy, and CrMo steel. Custom options and configurations are also available upon request. Two main pneumatic actuator alternatives as the standard choice the first, a stainless steel diaphragm actuator for air pressure up to 88 psi (6 bar), and the second, an aluminum double-acting piston actuator for pressure up to 176 psi (12 bar). can be up to 0,4 (10 ) in size, depending upon the specific design. LP Drum FT FC To HP Economiser / Drum To IP Economiser / Drum HP / IP Boiler Feedpump Figure 2: Multi-Z at Work Figure 3: HP Feedpump Recirculation System 4

flowserve.com Cv Table The table shows standard values. For an engineered valve the values depend on the service conditions. Size DIN ANSI Stages 3 4 5 6 xf 0.957 0.985 0.995 0.998 Sigma 1.045 1.015 1.005 1.002 Stroke Min - Max Kvs Cv Min - Max Kvs Cv Min - Max Kvs Cv Min - Max Kvs Cv 25 10 1.1-2.0 1.31 0.9-1.2 0.77 2.0 0.46 0.4 0.26 1" 0.4 1.3-2.3 0.05 1.1-1.4 0.03 0.8 0.02 0.5 0.01 40 / 50 15 2.9-10.1 3.41 2.3-5.9 2.02 2.0-3.4 1.18 2.0 0.70 1.5 / 2" 0.6 3.3-11.7 0.13 2.7-6.8 0.08 2.3-4.0 0.05 2.4 0.03 80 25 5.5-25.0 5.35 4.5-14.5 3.15 3.9-8.5 1.86 3.5-5 1.09 3" 1.0 6.4-28.9 0.21 5.2-16.8 0.12 4.5-9.8 0.07 4.0-5.8 0.04 100 40 8.3-43.4 7.32 6.8-25.0 4.26 5.9-14.5 2.48 5.2-8.5 1.46 4" 1.6 9.6-50.2 0.29 7.8-28.9 0.17 6.8-16.8 0.10 6.1-9.8 0.06 150 60 12.7-88.3 10.42 10.4-51.0 6.09 9.0-30.0 3.60 8.1-18 2.18 6" 2.4 14.7-102 0.41 12.0-59.0 0.24 10.4-34.7 0.14 9.1-20.8 0.09 Specifications Size 1-6 ; DN25-150, other sizes upon request Pressure Class Class 300-2500; PN 40-400 Body Materials Carbon Steel (1.0460) Stainless Steel (1.4571, 1.4404) CrMo Steel (1.7335, 1.7380) Others upon request Body Type Angle End Connections Weld ends Flanged Screwed NPT Others upon request Trim Type Trim Design Plug Material Liner Material Seat Material Actuator Balanced or Unbalanced Linear Multistage Trim 3 to 6 stages 1.4122 (440C) required by application 1.4112 (440B) required by application 1.4112 (440B) required by application Depending on Cv value and size up to 0.4 (10 ) Diaphragm Actuator Type KP (Stainless Steel) Piston Actuator Type VL Electric Actuator Hydraulic Actuator 5

Exploded view Various Packing Options (including ISO 15848-1 certified) Bonnet Liner Optional Venturi outlet Multistage plug Seat Ring Various End Connection Types 6 Figure 4: Exploded View

flowserve.com Actuator Options Pneumatic actuators The Multi-Z Severe Service Valve can be equipped with two high performance pneumatic actuator options: The single acting diaphragm actuator Series KP made of stainless steel and The double acting cylinder actuator Series VL for high duty applications and high air supply. Both actuator series are widely used in different applications for almost all Valtek and Käer valve series around the world. The Multi-Z accoodates the different market demands by adapting the actuator individually to the valve. Precise actuator accuracy in combination with Flowserve positioners gives high performance and optimised processes back to the user. Figure 5: Pneumatic Actuator Electric actuators Most types of electric actuator can be adapted to operate the Multi-Z Severe Service Valve. Based on this flexible design in combination with linear motion units, Flowserve is able to provide the electric actuator the customer is familiar with. This helps to reduce maintenance cost and reduces spare part inventory. Electric actuators are used in environments where compressed air is not available. Figure 6: Electric Actuators 7

Worldwide Regional Headquarters Flowserve Corporation Flow Control 1350 N. Mt. Springs Parkway Springville, UT 84663 USA Phone: +1 801 489 8611 Fax: +1 801 489 3719 Your Contact: Flowserve (Austria) GmbH Control Valves - Villach Operation Kasernengasse 6 9500 Villach Austria Phone: +43 (0)4242 41181 0 Fax: +43 (0)4242 41181 50 Flowserve India Controls Pvt. Ltd Plot # 4, 1A, E.P.I.P, Whitefield Bangalore Kamataka India 560 066 Phone: +91 80 284 10 289 Fax: +91 80 284 10 286 Käer Products Europe, Middle East, Africa, Asia, Pacific KMENBR1631-00 08/08 Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products might be used in numerous applications under a wide variety of industrial service conditions. Although Flowserve can (and often does) provide general guidelines, it cannot provide specific data and warnings for all possible applications. The purchaser/user must therefore assume the ultimate responsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and understand the Installation Operation Maintenance (IOM) instructions included with the product, and train its employees and contractors in the safe use of Flowserve products in caonnection with the specific application. While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because Flowserve is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise concerning these provisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices. 2007 Flowserve Corporation, Irving, Texas, USA. Flowserve is a registered trademark of Flowserve Corporation. Flowserve Essen GmbH Manderscheidtstr. 19 45141 Essen Germany Phone: +49 (0)201 8919 5 Fax: +49 (0)201 8919 662 Käer Products Americas Flowserve (FCD) Käer Valves INC. 1300 Parkway View Drive Pittsburgh, Pa 15205 USA Tel.: +1 412 787 8803 Fax: +1 412 787 1944 8