S Voltage Regulators GENERAL. PRODUCT INFORMATION Introduction. Contents. Acceptance and Initial Inspection. Handling and Storage.

Similar documents
S Voltage Regulators GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage. Standards

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage.

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage

Effective June 2016 New Issue

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

Effective March 2015 Supersedes S August 2012

This Kit Is for Use with Types RE, RVE, WE, WVE, VWE, VWVE27, and VWVE38 Reclosers.

COOPER POWER SERIES. Testing a motor capacitor on a voltage regulator procedure instructions. Voltage Regulators MN225064EN

S Fault Indicators. S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions. Contents INSTALLATION PROCEDURES

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

Type NR oil switch installation and operation instructions

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

Effective November 2016 Supersedes February 2012 (S )

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

Effective November 2016 Supersedes September 1998 (S )

High-voltage primary bushings installation instructions

COOPER POWER SERIES. Pad-mounted Switchgear MN285019EN. Effective March 2017 Supersedes February 2007 (S )

COOPER POWER SERIES. Types 4H single-phase and 6H three-phase vacuum interrupter conversion kits. Reclosers MN280014EN

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

S Voltage Regulators. Contents. QD3 Quik-Drive Voltage Regulator Tap-Changer Manual. Figure 1B. QD3 Tap-changer. Figure 1A. QD3 Tap-changer.

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

Figure 1. Kearney Type HX cutout.

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

COOPER POWER SERIES. Quick Connect Assembly (QCA) Retrofit Kit, General Electric Installation Instructions. Voltage Regulators MN225075EN

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

COOPER POWER SERIES. KA1169R Closing Coil Transfer-Switch Accessory Operation. Reclosers MN280069EN

COOPER POWER SERIES. KA662R tank-lifting windlass assembly and installation instructions. Recloser Mountings MN280071EN

Effective May 2017 Supersedes January 2003 (S )

Effective May 2017 Supersedes December 2004 (S )

COOPER POWER SERIES. Dielectric grease application to recloser cable instructions. Reclosers MN280070EN

COOPER POWER SERIES. KA716L7001 adjustable control valve kit for Types L, E, 4E, V4E, and V4L reclosers installation and adjustment instructions

COOPER POWER SERIES. Mercury switch to microswitch retrofit kit KA349WE installation instructions. Reclosers MN280022EN

COOPER POWER SERIES. KA146W5 single pole-mounting hanger; KA146W2 tank lifting windlass assembly and installation instructions. Reclosers MN280039EN

COOPER POWER SERIES. 600 A 15 kv and 25 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650004EN

COOPER POWER SERIES. 600 A 35 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650003EN

COOPER POWER SERIES. 600 A 15/25 kv class BOL-T and separable splice connector assembly installation instructions

COOPER POWER SERIES. Electronic control battery testing, charging, and replacement instructions. Reclosers MN280074EN

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN

Installation Instructions For Motor Control Center (MCC) Units

Max IV Rear Axle Replacement For models after Serial Number and all rear splined axle replacements.

KFE10010-E. Reclosers. Contents. Type KFVE and KFVME (27kV) Bus Bar Kit KRK710-1 Installation Instructions. Cooper Power Systems

COOPER POWER SERIES. Fused loadbreak elbow connector installation instructions. Loadbreak Apparatus Connectors MN650014EN

ELB ELB

SIEMENS. XJ-L Busway Systems. Storage, Installation and Maintenance Instructions for... Piece No. 32-J Rev 3

S Contents. Applicable to Serial Numbers A101 and above or beginning with CP57.

S Fault Interrupters. Type CI; Three-Phase Installation and Operation Instructions. Service Information

Throttling Pendulum Gate O-ring Replacement Procedure Rev. A, May 2012

IK : High-Pressure Turbocharger Replacement. Study Guide. Course Code: 8472

COOPER POWER SERIES. Types D and DV recloser installation instructions. Reclosers MN280030EN

A/C COMPRESSOR SERVICING Article Text 1991 Saab 9000 For Copyright 1997 Mitchell International Friday, October 15, :22PM

BETTIS ACTUATOR & CONTROLS SERVICE INSTRUCTIONS FIELD CONVERSION OF SPRING CARTRIDGE FAIL DIRECTION CLOCKWISE TO COUNTER-CLOCKWISE OR THE INVERSE

COOPER POWER SERIES. Manually-Operated M-Force Switch Installation and Operation Instructions. Switches and Disconnects MN008003EN

INSTALLATION GUIDE. Kawasaki KLR Manual Revision:

COOPER POWER SERIES. Instructions for oil-filled, single-phase overhead distribution transformers. Distribution Transformers MN201003EN

Kysor On/Off Rear Air Fan Drive

Torqueflite Manual/Automatic Valve Body

Falcon 5250 complete repair kit

BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY FOR CB-SR-S SEISMIC SPRING RETURN SERIES PNEUMATIC ACTUATORS

GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

Raychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions

2013 IMPCO Technologies, Inc. Page 1 of 20 EPR Repair Kit Instructions (PPI-122, Rev-B)

Trike Conversion Installation Guide for Harley-Davidson Sportster Motorcycles 2004 & Up Revision 7

Discount-Equipment.com

Owner smanual. Banks TorqueTube System Ford 5.4L F-150 (Late Body Style) with Installation Instructions

INSTRUCTIONS. Disassembly. Shifter Cam Assembly. Shifter Forks

Maintenance Information

Maintenance Information

920 Remote Control Switches

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

Kysor On/Off Rear Air Fan Drive

INSTALLATION INSTRUCTIONS

BEFCO. Operator s Manual BABY HOP & HOP FERTILIZER SPREADERS ACCESSORIES SIDE ROW DISCHARGE. AA4-120 (fits models Hop 209 & 212) DEFLECTOR

NOTE: Visit our website at for video repair procedures, under the Tools section.

Weistec M113K Supercharger System Installation Guide

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications.

Maintenance Information

PRODUCT SERVICE MANUAL. BK6DHZ(C)-250, 275, 312 and 400 PUMPS

INSTALLATION GUIDE Bolt-On Drag-Race Strut Clip Chevy II

Installation Manual TWM Performance Kia Forte Short Shifter

INSTALLATION INSTRUCTIONS

HYDRAULICS. TX420 & & lower. Hydraulic Tandem Pump Removal. 4. Remove the LH side panel (Fig. 0388).

MODEL HD-BTC. Installation, Operation & Repair Parts Information REV041416

FOR FUTURE REFERENCE SERIES 93HPS

BMW 3 Series E46 Front Wheel Bearing

Suspension System RS6582B

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS

Transcription:

Voltage Regulators QD8 Movable Contact Board Replacement Procedure Kit 5742895B01 Service Information S225-50-38 Contents General..................................... 1 Parts Supplied............................... 1 Kit Parts................................... 1 Tools Required............................... 1 Product Information........................... 1 Safety Information............................ 2 Installation Procedure.......................... 3 GENERAL The purpose of this replacement procedure is to provide the instructions for replacing the QD8 Movable Contact Board. PARTS SUPPLIED Item Part Number Descrioption Qty 1 5742895B01 QD8 Movable Contact Board 1 Kit KIT PARTS Part Number Description Qty 0740785801 T875 TC-Main Contact Assembly 1 2242895B02 T875 TC-FPL-Steel Shaft 1 0800073768Z Screw #8-32x1.125 Sock HD Cap*SS* 1 2242895B01 T875 TC-FPL-G10 Shaft 1 A5212941 Net Lock: 1/2-13 (Hex-Top/Lock)*MS* GR-A 1 S2255038 T875 TC-G10 Shaft-Main Cont Instruction 1 0791646A04 T875 TC-Main Stat CNTCT Assy 1 0800005001Z Nut Hex 1/2-13 (Jam) *Brass* 1 TOOLS REQUIRED Description Qty 1/2 inch drive ratchet wrench 1 1/2 inch drive - 3/4 inch deep well socket 1 1/2 inch drive - 3/4 inch socket 1 1/2 inch drive ratchet wrench extensions - 12 inch 1 3/8 inch drive ratchet wrench 1 3/8 inch drive 7/16 inch socket 1 3/8 inch drive - 9/16 inch socket 1 1-1/8 inch open end wrench 1 3/4 inch open end wrench 1 5/8 inch open end wrench 1 Channel Lock pliers 1 1/2 inch drive 0-600 lb-in (0-75Nm) torque wrench 1 3/8 inch drive 0-200 lb-in (0-25 Nm) torque wrench 1 1/2 inch drive 0-180 ft-lb (0-250 Nm) torque wrench 1 3/8 inch drive 0-180 ft-lb (0-250 Nm) torque wrench 1 Long fl at bladed screwdriver 1 9/64 inch hex head socket - 3/8 inch drive 1 3/8 inch drive ratchet wrench extension - 12 inch 1 Rubber Mallet 1 Spreader bar 1 Loctite 243 1 Portable pump 1 Vacuum pump 1 Hi-pot tester 1 Tefl on tape 1 PRODUCT INFORMATION Introduction The new, improved QD8 Movable Contact Board design adds to the reliability of Cooper Power Sytstem's QD8 tap changer. The QD8 Movable Contact Board prevents the possibility of high voltage tracking between the movable contact and ground. Read This Manual First Read and understand the contents of this manual and follow all locally approved procedures and safety practices before installing or operating this equipment. Additional Information These instructions cannot cover all details or variations in the equipment, procedures, or process described nor provide directions for meeting every possible contingency during installation, operation, or maintenance. For additional information, contact your representative. Acceptance and Initial Inspection Each movable contact board is in good condition when accepted by the carrier for shipment. Upon receipt, inspect the shipping container for signs of damage. Unpack the movable contact board and inspect it thoroughly for damage incurred during shipment. If damage is discovered, file a claim with the carrier immediately. Handling and Storage Be careful during handling and storage of the movable contact board to minimize the possibility of damage. If the movable contact board is to be stored for any length of time prior to installation, provide a clean, dry storage area. Standards ISO 9001:2000 Certified Quality Management System March 2007 New Issue Printed in U.S.A. 1

QD8 Movable Contact Board Replacement Procedure! Cooper Power Systems products meet or exceed all applicable industry standards relating to product safety. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Cooper Power Systems employees involved in product design, manufacture, marketing and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high-voltage lines and equipment and support our Safety For Life mission.! The instructions in this manual are not intended as a sub stitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians, who are familiar with this equipment should install, operate and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high- and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as flash clothing, safety glasses, face shield, hard hat, rubber gloves, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. INFORMATION Safety Instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER: Hazardous voltage. Contact with high voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around high- and low-voltage lines and equipment. WARNING: Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING: Indicates a potentially hazardous situation which, if not avoided, could result In death or serious injury. CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in equipment damage only. WARNING: This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply may result in death, severe personal injury and equipment damage. WARNING: Power distribution equipment must be selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install or maintain this equipment can result in death, severe personal injury, and equipment damage. 2

! S225-50-38 INSTALLATION PROCEDURE 1. Manually run the tap changer to neutral. 2. Disconnect the control cable from the bottom of the junction box (refer to Figure 1). Junper Bar Junction Box Contact Lead 2-Raise Stationary Contact Control Cable Figure 1. Figure 2. 3. Remove the series arrester. Release the internal pressure by using the pressure relief device on the side of the regulator. Note: If the regualtor tank is round and has a thermometer, the thermometer needs to be removed. Lower the oil level below the thermometer well and remove the thermometer well before untanking the regulator. 4. Disconnect the cover grounding strap. Free the cover by removing the cover bolts. 5. Attach a sling or hooks with a spreader bar to the lifting eyes and raise the cover, with the core and coil assembly, until the top of the coil is approximately one inch under oil (ensure the capacity ratings of the lifting equipment are sufficient). As a safety precaution, blocking between the cover and the tank should be used. Lower assembly just enough to engage the blocking. 6. Remove the nuts from the 2-raise stationary contact posts using a 3/4 inch deep well socket. Remove the 2-raise stationary contact lead and jumper bar from the 2-raise stationary contact posts. Remove the 2- raise stationary contact from the phenolic panel (refer to Figure 2). Save the nuts for re-assembly. 7. Remove the two bolts that mount the actuator finger with a 7/16 inch socket wrench. Remove the actuator finger (refer to Figure 3). Save the bolts for re-assembly. Mounting Bolts Figure 3. Actuator Finger 8. Remove the nut from the end of the main shaft with a 3/4 inch socket wrench. While removing the nut, the shaft will have to be prevented from turning. Use a 5/8 inch open end wrench if the tap changer has a molded movable contact board (the shaft has two flats for the wrench engagement). Use a channel lock pliers if the tap changer has a phenolic movable contact board (the shaft does not have any flats to engage) (refer to Figure 4). 3

QD8 Movable Contact Board Replacement Procedure Main Shaft Nut 10. Slide the movable contacts off the neutral stationary contact into the open space created by the removal of the 2-raise stationary contact. Disengage the ring contacts from the rings by pulling the movable contact board toward the steel panel. Remove the movable contact board (refer to Figures 6 and 7.) Main Shaft Neutral Stationary Contact Figure 4. Figure 4. 9. Pull the main shaft out about 1 inch from the phenolic panel side of the tap changer. Use a rubber mallet to tap the main shaft through the metal panel if necessary. Now remove the E-clip from the main shaft with a pliers so the main shaft can be pulled out through the phenolic panel. To prevent the washer from falling off the shaft while removing the geneva gear, slide the washer toward the movable contact board (refer to Figure 5). Hold the geneva gear and pull the shaft out of the geneva gear hub only as far as needed to remove the geneva gear. Remove the geneva gear. Remove the washer from the shaft and then remove the shaft completely. If the shaft can not be pulled out completely because it is bumping into the reactor coils, unscrew and remove the white cap from the shaft to allow for shaft removal. Figure 6. Movable Contact Board Inner Contact Ring Figure XX E-Clip Washer Figure 7. Outer Contact Ring Geneva Gear Figure 5. 4

! S225-50-38 11. The new shaft consist of two parts, a thermoset composite shaft and a steel shaft (refer to Figure 8). Steel Shaft Half-moon shaped drive on the sprocket Sprocket Front of Geneva Gear Thermoset Composite Shaft Steel Shaft Figure 10. Figure 8. To install the geneva gear, insert the steel shaft into the front of the geneva gear and then insert the threaded end of the steel shaft into the mounting hole in the steel panel. The pin on the back of the geneva gear must line up with the slot in the geneva section and the half-moon shaped groove on the outer edge of the geneva gear must line up with the half-moon shaped drive on the sprocket. Secure the steel shaft to the steel panel using the nut removed in Step 8. Use a 1-1/8 inch open end wrench to hold the steel shaft while securing the nut on the threaded end of the shaft with a 3/4 inch socket wrench. Torque the nut to 180 to 400 in-lbs (20.33 to 45.19 Nm) (refer to Figures 9 and 10). Insure the geneva pin is engaged with the geneva section by checking the viewing hole in the steel panel (refer to Figure 11). Geneva Section Geneva Pin Figure 11. Viewing hole in the steel panel Steel Shaft Half-moon shaped slots on the outer edge of the geneva gear Geneva Gear Pin Geneva Section Figure 9. 5

QD8 Movable Contact Board Replacement Procedure 12. Hold the movable contact board so that the movable contacts are located in the space created after the 2-raise stationary contact was removed. Align the ring contacts with the rings. While holding the movable contact board in place, take a long blade screw driver and pry the buttons on one of the ring contacts apart. Push the contact onto the ring while the contact buttons are spread apart. Repeat this process on the other ring contact (refer to Figure 12). Ring Contact Screw driver prying the buttons on the ring contact apart 13. Insert the small end of the thermoset composite shaft through the hole of the phenolic panel, then through the hole in the movable contact board, and into the end of the steel shaft. Use a rubber mallet to lightly tap the back end of the thermoset composite shaft to ensure the shaft is inserted all the way into the steel shaft. Apply a drop of Loctite 243 on the last 1/4 inch of the coupling screw threads. Insert the screw into the side of the steel shaft with the countersunk hole. The thermoset composite shaft can be turned using a 3/4 inch open end wrench on the back end of the shaft to align the holes of the two shafts. Torque the coupling screw with a 9/64 hex wrench (Allen Wrench) to 10 to 15 in-lbs (1.12 to 1.69 Nm) (refer to Figure 14). Figure 12. Coupling Screw Slide the main contacts on to the neutral stationary contact (refer to Figure 13). Figure 14. Neutral Stationary Contact Figure 13. 14. Use the nuts that were removed in Step 6 to reinstall the 2-raise stationary contact and reconnect the jumper bar and contact lead. Torque the nuts for the stationary contact, jumper bar and lead to 180 to 192 in-lbs (20.33 to 21.69 Nm). 15. Reinstall the actuator finger to the geneva gear using the bolts removed in Step 7. The actuator finger should extend into the movable contact board actuator pocket. Torque the bolts to 30 to 40 in-lbs (3.38 to 4.51 Nm). 16. Lift the core and coil slightly and remove the safety blocking. Lower the assembly until the cover is 6 inches above the tank. 17. Wipe the outer edge of the cover and the tank lip so they are clean and free of debris. Replace the cover gasket on the tank lip and align the gasket bolt holes to the tank bolt holes. 18. Lower the cover until the cover is seated on the gasket, making sure the gasket bolt holes align with the cover bolt holes. If the cover does not seat on the gasket, remove the hand hole cover and loosen the horizontal side channels to ensure proper seating of the regulator in the tank and proper cover seal. 6

! S225-50-38 19. Replace the rubber bolt gaskets and lock washers and secure the cover to the tank using the cover bolts removed earlier (Note: the lock washers need to be stainless steel). Re-apply anti-seize to the bolts if needed. Torque the nuts to 26 to 28 ft-lbs (35.25 to 37.96 Nm). After all the nuts have been tighten once, torque them again. Torque the horizontal side channel bolts to 35 to 40 ft-lbs. (47.45 to 54.23 Nm) and replace hand hole cover. Torque the hand hole cover bolts to 26 to 28 ft-lbs (35.25 to 37.96). Note: If the regulator has a thermometer and is a round tank, re-install the thermometer well and replace the oil. 20. Pressurize the tank to 4 psi with nitrogen and check for leaks and reconnect the control cable. 21. After the unit has been re-assembled, perform the following test: 1) Run the regulator to 16 Raise using the automatic operation mode. This operation can be done by changing function code 1 to a value that causes the regulator control to see an out of band low indicator. Recommend setting function code 1 to 130 volts for this operation. This test should be done using an external power source to power the CAUTION: When applying external voltage to the control, a true AC wave power source must be used and the polarity checked before connections are applied to the external source connections on the control panel. control and tap changer. Return the Auto/Remote/Manual Control Function Switch to the Manual Position, use the Lower Switch and tap the regulator back to Neutral. Reprogram function code 1 back to the original set voltage value. 2) Apply 2 torr vacuum 25 minutes. 3) Allow 4 hours soak time before energizing. 4) After completing steps 1-3, perform a hipot test using the following guide. If the regulator is a new unit and has not been energized on a Utilities Electrical System, use the following AC voltage for hipot values for one minute: 150 BIL Regulators 50 kv AC 200 BIL Regulators 70 kv AC if the regulators are used or have been energized on a Utilities Electrical System, use the following AC voltages for hipot values for one minute: 150 BIL Regulators 30 kv AC 200 BIL Regulators 42 kv AC 7

2007 Cooper Power Systems, Inc., or its affiliates Locktite is a registered trademark of Henkel Technologies 1045 Hickory Street Pewaukee, WI 53072 www.cooperpower.com