Lube Level Maintainer

Similar documents
Lube Level Maintainer

Lube Level Maintainer

Lube Level Maintainer

LS200, LS200N, LS200NDVOR Series and L1100 Liquid Level Switches

Installation for L1100, L1200, L1200N Series Liquid Level Switches and DVU150, DVU175, and DVU2105/2115/2120 Series Dump Valves. GENERAL INFORMATION

Installation Notes for Ingersoll Rand KVG-123 Compressor Package (Up to 255 Gallon Sump Capacity) Ingersoll Rand KVG-123 Compressor Package

Moduflow. ILP and RFP Low Pressure Filters. Series

TL960 PARTS MANUAL. Fuel Section. Page 9-1. Fuel 09/97

KENCO ENGINEERING COMPANY P.O. BOX TULSA, OK PHONE(918) FAX: (918)

WARNING. Murphy W-Series Engine Panels General Installation Instructions. Installation Accessories

WARNING. Murphy W-Series Engine Panels General Installation Instructions. Installation Accessories

An Illustrated Manual: Constant Level Lubricators Function, Installation, and Features

15/40/80CN Series. Medium Pressure Filters

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

Low Profile J Series Power Unit with Vane Pump

OPW Installation and Maintenance Instructions OPW Series Primary and Secondary Bucket Replacement Instructions

Shop Press. Maximum Capacity: 25 Tons and 55 Tons SAFETY PRECAUTIONS

15/40/80CN Series Coreless Medium Pressure Filters

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

Oil Cooler Thermostat for GM LS Series Engines, Rear Sump

Hose Reel Kit for Multi-Pro 1200 and 1250 Sprayers. Installation Instructions. Form No Model No Serial No.

UNIVERSAL PUMP HANGER INSTALLATION INSTRUCTIONS

Moduflow Series IL2/RF2/CF2 Low Pressure Filters

DYNA OIL COOLER AND THERMOSTAT KIT

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

Auxiliary Transmission Filter Kit Designed For 7.3L Ford Powerstroke Trucks

Model RM-1 Riser Manifold Commercial and Residential General Description

IL8 Series. Medium Pressure Filters

Series 3900/M Pump Retrofit Kit

IL8 Series. Medium Pressure Filters

GM 4L80-E, 4L85-E SURE CURE KIT

The Better Dispensers by Bergquist

WARNING. Diode Package The Murphy diode package ( ) is designed to allow the fuel shutoff valve to be used with dual Magneto Ignition systems.

UNIVERSAL PUMP HANGER INSTALLATION INSTRUCTIONS

KENCO ENGINEERING COMPANY P.O. BOX TULSA, OK PHONE(918) FAX: (918)

GM 4L80-E, 4L85-E SURE CURE KIT

AEROMOTIVE Part # L Mustang Digital FMU INSTALLATION INSTRUCTIONS

Edelbrock EFI Universal Fuel Sump System - Adjustable Part #36031, INSTALLATION INSTRUCTIONS

Installation and Operating Instructions Electro-Pneumatic Rotary Positioner SP-21. Description of Device. Part Number System

Model 116 DPI Switch Installation and Operating Instructions

Installation, Operation and Maintenance Manual

Installation and Service Instructions

Instructions for Installation, Operation, Care and Maintenance

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

Step 6: Remove and save the MAP sensor for later use. Step 7: Remove the passenger side intercooler pipe and the EGR intake manifold.

ETP-5G & ETP-10G ECO-TECH PLUS GAS CONVECTION STEAMER PARTS AND SERVICE MANUAL

KENCO ENGINEERING COMPANY P.O. BOX TULSA, OK PHONE(918) FAX: (918)

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Mini-Roto TM Paddle Wheel Installation & Operation Manual

SHOP PRO FXP 95 UPGRADE KIT (REGULATED)

DESCRIPTION MECHANICAL FUEL PUMP FUEL FILTER HIGH PRESSURE (35-90 PSI) HIGH PRESSURE (35-90 PSI) (STEEL/INCLUDED)

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

BMK-12. Dual-Gard By-Pass Filter Mounting Kit Installation and Servicing Instructions

ENGINE DRIVEN COMPRESSOR --- GM 4.8, 5.3, 6.0, 6.2 ENGINES. (99-13 Fullsize GM trucks)

TMS Series MP46x Flex Probes* Installation Instructions

Technician Turbocharger Guide for the L Power Stroke Engine

MB SERIES SMB SERIES MINIATURE TANK BREATHERS MINIATURE TANK BREATHERS ACCCESSORIES. Phone (608) Fax (608)

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.

INSTALLATION MANUAL. MB-180, MB-210 and MB-210L Motor Brake INSTALLATION. Force Control Industries, Inc. DESCRIPTION OPERATION

LABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL

BD Twin Turbo Cobra Kit

DIGIFLO ELECTRONIC FLOWMETER

F479 HVE V PARTS LIST

Levalarm Gold. Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016

Oil Filter Cart. Quad Filtration OPERATOR S MANUAL & PARTS LIST

Solenoid Valve Installation Kit

BD Twin Turbo Cobra Kit

Sentry Battery Charger. Installation and Operations Manual Section 75

Suspension System RS6582B

DEMA 259B DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

P70, P72, and P170 Controls for Low Pressure Applications

FAX

I-BFV.KIT Butterfly Valve Gear Operator Replacement

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

632 Western Avenue Henniker, New Hampshire Tel. (603) Fax (603) POSITION OF THE ROLLER PLATES

Instruction Sheet. Subject: Installations Instructions. Air Compressor Kits. Importan

AFD-280U Parts List AFD-280U. (350 gm) (450 gm) (700 gm)

INSTALLATION INSTRUCTION 88094

PARTS LIST FOR AIR COMPRESSOR/GENERATOR/WELDER AGW-SR14-30M AGW-SR14-B

Installation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC

Installation Instructions

Installation Instructions for Series 3100V Low Level Indicator

Auxiliary Transmission Filter Kit Designed For 6.0/7.3L Ford Powerstroke Trucks Part # Vehicle Application Type

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:

Installation. Installation. 12. System Diagram... 10

PARTS LIST FOR AIR COMPRESSORS 15 Hp Industrial Duplex. Copyright 2009, Mi-T-M Corporation

Oil Cooler Thermostat for LS & Vortec Series Engines, Rear Sump

SERIES 270A HIGH SIDE FLOAT VALVES BULLETIN 270A-SB11-02 SERVICE BULLETIN

Oregon Fuel Injection

Auxiliary Transmission Filter Kit

Instant Chat off the main page of Or simply call our tech team at

Installation Manual v1.1: RFE Deep Transmission Pan Dodge Ram 2500 and 3500

a UCA Group Company Installation & Operation Manual Day Tank TRS Series Serial # UL Listed # Order #

Type N550 Snappy Joe Emergency Shutoff Valves

4 December 2017 PN# , , Dodge 6.7L Rumble B SXE (I-00400) 1. BD Rumble B SXE. D o d g e 6. 7 L H P C R Installation Instructions

earth safe Fuel Systems for Critical Power

Purging Air From Divider Block Lubrication Systems

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

LOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS

Transcription:

Lube Level Maintainer Models LM500/LM500-TF Installation Instructions 00-02-0729 02-11-11 Section 15

Please read the following information before installing. BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT: A visual inspection of this product for damage during shipping is recommended before installation. It is your responsibility to ensure that qualified mechanical and electrical technicians install this product. Disconnect all electrical power to the machine. Make sure machine cannot operate during installation. Follow all safety warnings of the machine manufacturer. Read and follow all installation instructions. Please contact FW MURPHY immediately if you have any questions.

Table of Contents General Information... 1 Description... 1 Dimensions... 1 Operating the Range of the Snap Switch... 2 Test Feature... 2 Thumb-Valve TM Operation... 3 LM500 Series Flow Rates... 3 Service Parts (Specify part number)... 3 Hose Kit: (P/N 15000355)... 4 Vent Fittings Kit: (P/N 15000954)... 4 Fittings Kit: (P/N 15000943)... 4 Typical Installation... 5 Mounting the LM500... 5 Pipe Bracket Mounting (PM) (P/N 15000518)... 5 Universal Bracket Mounting (UB) (P/N 15000519)... 5 Base Mounting... 5 Crankcase (Oil Pan) Mounting... 6 Connecting Fittings and Hoses... 7 Connecting the LM500 to an Oil Supply Tank... 8 LM500 Typical Installation Shown... 8 Specifications... 9

General Information Description The Murphy LM500 model maintains the crankcase oil level of an engine, pump or compressor. Adjusted to the correct running-oil-level, the LM500 will replenish oil as it is used. The low-level switch will alarm and/or shutdown the equipment if the supply oil is lost and the equipment continues to use oil. The LM500-TF model includes a test feature that confirms both the float and switch are operating correctly with a single press of the test button. Dimensions Pipe Mount Universal Mount 02-11-11-1 -

Operating the Range of the Snap Switch Figure 1 shows the LM500 dial and the operating range of the switch. If level is within the designated zones, the switch will activate. The switch activates approximately 1/4 in. (6 mm) from the bottom of the low zone. The dial-in Figure 1 shows that if the level continues to drop into the low-low zone, a shutdown will occur. Figure 1 NOTE: color zones on dial face show approximate normal operating zones. Actual conditions may vary depending upon operating characteristics of the engine. Placement of the LM500 according to the above instructions will compensate for these conditions. Test Feature The form C (3-wire) contact allows a controller/enunciator to be wired as a closed loop system, resulting in a reliable fault-sensitive circuit. NOTE: Holding test button in for a prolonged period of time could cause crank case to over fill. 02-11-11-2 -

Thumb-Valve TM Operation As the equipment uses oil, the float falls, providing immediate level compensation. At FULL position, the float holds the valve closed. If the clean oil supply is depleted and oil level contuse to fall, the low level switch will operate an alarm or equipment shutdown. LM500 Series Flow Rates LM500 Series Flow Rates are based on SAE 40 motor oil @2 ft. head pressure. Friction losses due to piping are not considered. Service Parts (Specify part number) Description Part Number Vent Fittings Kit 15000954 Hose Kit 15000355 1/2 NPT x1/2in Hose Barbed Fitting 89080801 3/4NPT x 1/2in Hose Barbed Fitting 89081001 Pipe Bracket Kit 15000518 Universal Flange Kit 15000519 02-11-11-3 -

Hose Kit: (P/N 15000355) Quantity Description 1 1/2in (13mm) I.D. x 3ft. (914mm) long hose. 1 1in (25mm) I.D.x 3ft (914mm) long hose. 2 1/2in (13mm) worm gear clamp 2 1in. (25mm) worm gear clamp 2 1/2NPT x 1/2in. (13mm) barbed fitting Vent Fittings Kit: (P/N 15000954) Quantity Description 1 Tubing vent 1 1/4 x 1/4NPT connector Fittings Kit: (P/N 15000943) Quantity Description 1 Tubing vent 1 Hose barb, 1/2NPT to ½ Hose. 1 Hose Barb, 1in. I.D. HOSEX 3/4NPT 1 Connector, 1/4T x 1/2 02-11-11-4 -

Typical Installation Mounting the LM500 NOTE: Mount the LM500 as close as possible to the crankcase. CAUTION: Excessive vibration can cause overfill. Be sure mounting brackets are supported. The following instructions are based on the use of the pipe and universal mounting brackets shown on page 1. Pipe Bracket Mounting (PM) (P/N 15000518) 1. Mount a nominal 1/2in. (13mm) diameter pipe to the base of the engine. 2. Install the pipe bracket to the lm500 using two 1/4-20 UNC x 1 inch bolts; nuts and lock washers supplied. See Figure 2A. 3. Slip the LM500 onto the pipe and install the two adjustment bolts. Each bolt consists of a 1/4-20 UNC x 1in. bolt, nuts and lock washers. See Figure 2B. DO NOT tighten the adjustment screws too tight as height adjustment might be needed later during the operation. Refer to Connecting Fittings and Hoses, for more information regarding height adjustment of the LM500 in alignment with the oil level in the crankcase. Figure 2A Figure 2B Universal Bracket Mounting (UB) (P/N 15000519) The universal bracket has two mounting methods: base mounting or pan mounting. Base Mounting 1. Install the universal bracket to the base as shown in Figure 3A using two split lock washers and two 5/16 inch dia. Bolts or others a necessary. 02-11-11-5 -

2. Mount the LM500 to the universal bracket using two 1/4-20 UNC x 1-1/4 inch (32mm) bolts; flat and lock washers supplied (Figure 3B). DO NOT tighten the adjustment screws too tight as you will have to adjust the LM500 later in the installation process. Refer to Connecting Fittings and Hoses for information regarding height adjustment of the LM500 in alignment with the oil level in the crankcase. Figure 3A Figure 3B Crankcase (Oil Pan) Mounting 1. Install the universal bracket to the crankcase using the existing crankcase bolts (Figure 4A). Crankcase bolt diameter must be no larger than 7/16 inch (11mm). Figure 4A Figure 4B NOTE: Check clearance between crankcase and mounting bracket before installing the mounting bracket. If space between the crankcase and mounting bracket is narrow, attach LM500 to mounting bracket prior to installation on crankcase. 02-11-11-6 -

2. Mount the LM500 to the universal bracket using two 1/4-20 UNC x 1-1/4 inch bolts, flat and lock washers supplied. DO NOT tighten the adjustment bolts to tight as height adjustment might be needed later during the operation. Refer to Connecting Fittings and Hoses for information regarding height adjustment of the LM500 in alignment with the oil level in the crankcase. Connecting Fittings and Hoses The following instructions are based on the Murphy hose kit described on page 3. 1. Install the LM500 fittings in their proper locations NOTE: Apply a sealant such as Teflon, to all threaded connections. 2. Attach the 1 inch (25mm) diameter, flexible monitoring hose to the crankcase and the monitoring port on the LM500. See Figure 5. CAUTION: The hose must slope slightly downward from the LM500 and MUST NOT have any droops or low spots. NOTE: if the drain plug on the crankcase is used for the connection, it is recommended that a tee be installed to allow draining of the crankcase for service. 3. Install the 1/2 inch (13mm) I.D. x 3 ft (914 mm) hose to the vent connection on the LM500 and to vent connection on the crankcase. See Figure 5. The vent connection on the crankcase must be well above the regulated oil level. All hoses must be clear of obstructions, valleys, or dips that could create liquid traps, or gas/air pockets. The vent and crankcase connections should be as straight as possible. BEFORE CONTINUING, VERIFY THAT ALL HOSE CLAMPS ARE TIGHT. 4. Fill the crankcase to the proper oil level. IMPORTANT: With the engine running and warm, loosen the mounting bracket adjustment bolts and adjust the LM500 so that the oil level in the sight gauge is aligned with the middle of the green bar on the dial (see example, Figure 5). 5. Tighten the adjustment bolts securely. 02-11-11-7 -

Connecting the LM500 to an Oil Supply Tank 1. Remove the plug from the oil inlet connection. Be sure the removable screen, inside the connection, is clear of debris. Install the oil inlet connection. 2. Connect a 1/2inch I.D. (13mm) or larger hose to the oil inlet fitting on the LM500 and to the shutoff valve on the oil supply tank. See Figure 6. Recommended minimum height above the LM500 is 2 ft. (0.6); maximum 25ft (7.7mm). The hose must maintain a downward slope and not have low spots or droops. Maximum head pressure rating is 9.50psi or 25ft. oil (head pressure). 3. Before filling the supply tank with oil, be sure the tank is clean and dry and the shutoff valve is closed. Also, be sure all hoses and clamps are tight. Fill the tank with CLEAN oil. WARNING: Overfill condition can be caused by excessive inlet pressure and/or improper vent-to-crankcase installation. 4. After oil supply tank is full, open the shutoff valve. Next, make the proper electrical connections for the application. (See snap switch ratings on page 8 and schematic on page 2.) LM500 Typical Installation Shown WARNING: Perform this installation using appropriate protection. Trapped air and hot oil may cause burns. 02-11-11-8 -

Specifications Crankcase Balance Vent Connection: 1/2 NPTF (top). Inlet Connection: 2 x 3/4 NPTF (side) 1 x 3/4 NPTF (bottom) Thumb-Valve TM Material: Viton Snap-switch: SPDT rating 10 A, 125 VAC; 0.5 A, 125 VDC; 10 A, 30 VDC Wire leads: 18 AWGT x 14 in +/- 2 in (355 mm) length. Conduit Connection: 1/2 inch conduit (female, top). (Refer to 00-02-0735 Teflon Tape Wrapping Technique). Case: Die cast aluminum Lens: Clear Frog Eye non-staining, high impact, high temperature nylon; UV and heat stabilized. Dial: High visibility white background with solid green band for normal level indication. Maximum Inlet Pressure: 9.50 psi/25 ft. oil (head pressure). Maximum Differential: 2 in (51mm) between running and stopped. Maximum Ambient Temperature: 250 o F (121 o C) Float: 304 Stainless Steel Flow Rates: Refer to Flow Rate Chart on page 3. Section 15 02-11-11-9 - 00-02-0729