SUMMARY. St-jean-sur-richelieu, January 15th 2016 Client: America s heat Project: PI-20114

Similar documents
SUMMARY. St-jean-sur-Richelieu, 2016, January 12th Client : J.A. Roby Project :PI model : Polaris; Sirius; Véga; Antares; Centauri; Rigel

Tested: written by :

Tested by: written by :

United States Stove Company Project # Model: Breckwell SP1000 Type: Pellet-Fired Room Heater July 25, 2018

United States Stove Company Project # Model: KP60 AKA: AP60, VG60 Type: Pellet-Fired Room Heater May 31, 2018

Foyers Supreme Inc. Fireplace Products Project # 019-S Model: Fusion Type: Residential Wood Fired Heater February 19, 2016

TEST REPORT SCOPE: EMISSIONS, EFFICIENCY AND OUTPUT FUEL: CORDWOOD TEST STANDARD: EPA & CSA B MODEL: CADDY WOOD FURNACE

LOPEZ LABS CO-OPERATIVE. heatkit.com/html/lopez.htm 1.) SUMMARY OF 87 MASONRY HEATER EMISSIONS TESTS 2.) SUMMARY OF 14 MASONRY HEATER EMISSIONS TESTS

Industrial, Commercial and Institutional Boilers at Area Source Facilities (Boiler GACT) Final Reconsidered Rule Requirements Summary

RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006)

NFPA 286 STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH

3.1 Air Pollution Control Officer (APCO): as defined in Rule 1020 (Definitions).

New Fuels for Oilheat

Copyright Statement FPC International, Inc

RULE BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12)

This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)"

DEP7007CC Compliance Certification

Boilers, Steam Generators, and Process Heaters (Oxides of Nitrogen) - Adopted 10/13/94, Amended 4/6/95, 7/10/97

Appendix A.1 Calculations of Engine Exhaust Gas Composition...9

Cooling Capacity CFM in. w.c. (125 Pa)

Table 0.1 Summary Pollutant Discharge Test Results Engine Manufacturer. Number 24652

IDEAL STEEL HYBRID GEAR HEAD STOVES OWNER S MANUAL MODEL 210 BY WOODSTOCK SOAPSTONE COMPANY

AIR QUALITY PERMIT. Kennesaw State University - Marietta Campus

ABSOLUTE STEEL HYBRID

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

SECTION METERS AND GAGES FOR HVAC PIPING

AVL Particle Measurement System Aviation

Chariton Valley Biomass Project Iowa Switchgrass Cofiring Update

A novel concept to study sauna stoves

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA

Automatic CFD optimisation of biomass combustion plants. Ali Shiehnejadhesar

Cordwood Technology Outlook- The 2020 Threshold and Emerging Technologies

VALMET IBMACT & Utility MATS. Boiler Tune-ups

Tune-up Information. Owners and operators of all biomass-fired and oil-fired area source boilers.

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Multi-Sector Air Pollutants Regulations (MSAPR) May 2017

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

ENGINEERING CALCULATION SHEET AIR RESOURCES DIVISION

BULDER 00 ROOMHEATER

Copyright Statement FPC International, Inc

Dekati Solutions. Engine Emissions

RULE 4306 BOILERS, STEAM GENERATORS, AND PROCESS HEATERS PHASE 3 (Adopted September 18, 2003; Amended March 17, 2005; Amended October 16, 2008)

Copyright Statement FPC International, Inc

F8MTL. Product Specifications

PROGRESS HYBRID WOODSTOCK SOAPSTONE STOVES OWNER S MANUAL MODEL 209. Tested To UL 1482 Listed By Intertek Report #

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

KG7T (E and N Series)

KG7T (C and L Series)

FG7T (E and N Series)

ALLEGHENY COUNTY HEALTH DEPARTMENT AIR QUALITY PROGRAM

NO x Emissions Control in a Fluidized-bed Combustor Fired with Rice Husk

Test procedure and Specifications for Particle Number Portable Emissions Measurement Systems (PN-PEMS)

Evaluation of metal based mesh catalysts for stoves

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

1996, or for which modification is commenced on or before March 16, 1998, shall not exceed the

G8MVL. Product Specifications

Cooling Capacity CFM in. w.c. (125 Pa)

KG7T (C and L Series)

Cooling Capacity CFM in. w.c. (125 Pa)

402 LOSS OF EXEMPTION LOW FUEL USAGE 4032 SOURCE TESTING FREQUENCY 4043 SOURCE TESTING PROTOCOL

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

State of New Jersey. General Permit (GP-009A)

VENTING & COMBUSTION AIR GUIDE

HP5. Heated Probe. Main characteristics. Heated Probe for Micropollutants sampling

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand

CHALLENGER Propane to Natural Gas Instructions

Cooling Capacity CFM in. w.c. (125 Pa)

Model CBEX Elite HP

August 23,

Model CBLE Boilers HP

1070 SERIES ULTRA LOW NO X

Boiler Operation, Maintenance, and Settings. Matthew Baxter Technical Director, Core Biomass

RULE EMISSIONS OF OXIDES OF NITROGEN FROM SMALL INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS

The bereal Project - Scientific Highlights

PRE-INSTALLATION VENTING AND COMBUSTION AIR DESIGN GUIDE

Proposed Addendum ag to Standard , Ventilation for Acceptable Indoor Air Quality

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

50 CAR EFFICIENCY EVALUATION OF THE OPW CONTROL SYSTEM ON THE GILBARCO VAPORVAC VAPOR RECOVERY SYSTEM AT COSTCO CAL EXPO TEST DATE: SEPTEMBER 4, 2002

3. Operation of any applicable boiler on any amount of fuel oil shall be prohibited, except as provided in Subsection C.3.

RULE NOX REDUCTIONS FROM MISCELLANEOUS SOURCES (Adopted 12/13/2016)

PRODUCT CONFORMITY CERTIFICATE

G9MXE. Product Specifications

2017Compliance Table with methods.xlsx

Features Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design

Emissions Testing Report

FG7S (C and L Series)

CEMS FOR COAL FIRED POWER STATIONS DEVICE CALIBRATION AND MAINTENANCE

G9MXE. Product Specifications

TEST REPORT UL Fire test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

WFMR/WFML. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

Combustion and Boiler Performance Assessment of Kardia Power Plant

G23 Bulletin # September 1998 Supersedes June 1995

THC Heated FID 3-300A

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

CHAPTER 3 : TYPE I TEST ON SI ENGINES (VERIFYING THE AVERAGE EMISSIONS OF GASEOUS POLLUTANTS)

Transcription:

SUMMARY 1 Introduction... 4 1.1 General... 4 1.2 Test unit information... 4 1.3 Results... 4 1.4 Pretest information... 4 2 Summary of test results... 5 2.1 table 1A: Data Summary Part A... 5 2.2 table 1B: Data Summary Part B... 6 2.3 Table 1C : Hang Tag Information... 6 2.4 Table 2: Annual Weighting... 7 2.5 Test facility condition... 7 2.6 Dilution tunnel flow rate measurements and sampling data (Section 6.23 ASTM E2515)... 8 2.7 Dilution tunnel dual train precision... 8 2.8 1 st hour emission & Co total emissions... 9 3 Process description... 9 3.1 Discussion... 9 3.2 Air supply system... 9 3.3 Process operation during test... 10 3.4 Start-up operation... 11 4 Sampling systems... 11 4.1 Sampling locations... 11 4.2 Drawings... 11 4.3 Emissions efficiency testing equipment list... 11 5 Sampling methods... 11 5.1 Particulate sampling... 11 6 Quality assurance... 11 6.1 Instrument calibration... 11 6.1.1 Gas meters... 11 6.1.2 Stack sample Mass flow controller... 11 6.1.3 Gas analyzers... 12 6.2 Test method procedures... 12 Page 2 of 24

6.2.1 Leak check procedures... 12 6.2.2 Tunnel velocity flow measurement... 12 6.2.3 Pm sampling proportionality (ASTM E2515)... 12 6.2.4 Heat Output measurement... 12 Appendix Appendix A Unit Operating Procedures Appendix B Appendix C Raw data, forms and Results Drawing and specifications Appendix D Equipment list, calibration certificates and fuel analysis Appendix E Appendix F Unit pre-burn Operator's manual Appendix G unlock data & calculation forms Appendix H Appendix I Appendix J Appendix K Proportionality results Test load photographs photograph of the test setup Drawing of air and water flow pattern Appendix L example calculation Page 3 of 24

1 INTRODUCTION St-jean-sur-richelieu, January 15th 2016 1.1 GENERAL Laboratory Location: Services Inc., 695-B Gaudette St-jean-sur-richelieu. Elevation: 100 feet above sea level. Test program Purpose: EPA Hydronic Heater Subpart QQQQ Standard of performance for new residential hydronic heater Test dates: December 7 th to 17 th 2015 Test methods used: EPA Method 28 WHH and ASTM E2515 1.2 TEST UNIT INFORMATION General Manufacturer: America s Heat Product type: Automatic feed Pellet boiler Combustion system: Pellet boiler Unit tested: AHB 170P model name and description : AHB 170 Particularities Options: none Product line similarities: none 1.3 RESULTS Emission results obtained Weighted average emission rate wood pellet : 0.108 lbs/mmbtu output Maximum rate cap: 1.68 grams/hour at run # 1 cat 4 Conformity: Step 1 of EPA Hydronic Heater Subpart QQQQ Standard of performance for new residential hydronic heater from May 2015 to May 2020, 0.32Lb/MMbtu heat output (weighted average) 1.4 PRETEST INFORMATION Unit condition: The unit was received by the client, inspected and found to be in good condition Set up Venting system type: 6 inch Steel pipe and insulated chimney System height from floor: 15 feet Page 4 of 24

Particularities: the pretest run was done with the same calibrated pellet as four official tests run Break in period Duration: the preburn has been done by the manufacturer, data provided in appendix E Average burn rate: 20% of the maximum heat output Fuel: Pellet 2 SUMMARY OF TEST RESULTS 2.1 TABLE 1A: DATA SUMMARY PART A Wfuel MCave Qin Qout CAT Run # 1 4 2 3 3 2 4 1 Load % Capacity Tgt Load (Btu/h) Act Load (Btu/h) Act Load (% max) Test Duration (h) Wood Wt (lb) Wood Moisture (%DB) Heat input (Btu) Heat output (Btu) <15% of max 11 200 10348 92% 4,12 10,47 5,90 85 919 42 598 16-24 % of max 17 600 14324 81% 4,12 13,97 5,90 114 672 58 966 25-50 % of max 36 000 36933 103% 4,03 29,90 5,90 245 404 148 963 max capacity 80 000 77771 97% 4,07 60,57 5,90 497 066 316 269 Page 5 of 24

2.2 TABLE 1B: DATA SUMMARY PART B T2 min Et (g) E (lb/mmbtu out) E (g/mj) E (g/hr) E (g/kg) hdel (%) hslm (%) CAT Run # Load % Capacity Min return water temp Total PM Emissions PM output based PM output based PM rate PM factor Delivered efficiency Stack loss Efficiency 1 4 2 3 3 2 4 1 <15% of max 145 2,5 0,129 0,055 0,60 0,55 50% 68% 16-24 % of max 144 3,6 0,133 0,057 0,86 0,59 51% 69% 25-50 % of max 141 4,4 0,064 0,028 1,08 0,34 61% 65% max capacity 127 6,8 0,048 0,020 1,68 0,26 64% 70% 2.3 TABLE 1C : HANG TAG INFORMATION Manufacturer Model Number America's Heat AHB 170P Maximum output rating 80 000 BTU/hr Annual efficiency rating ηavg 54% (using higher heating value) Particle emissions Eavg 0,997 GRAMS/HR (average) 0,108 LBS/ MILLION Btu OUTPUT Carbon monoxide Cog/min 0,477 Grams/minute Page 6 of 24

2.4 TABLE 2: ANNUAL WEIGHTING St-jean-sur-richelieu, January 15th 2016 CAT Weighting Factor (F j ) η del X F j E g/mj, j X F j E g/kg, j X F j E lb/mmbtu Output, j X F j E g/h, j X F j 1 0,437 0,217 0,024 0,242 0,056 0,264 2 0,238 0,122 0,014 0,141 0,032 0,205 3 0,275 0,167 0,008 0,093 0,018 0,297 4 0,050 0,032 0,001 0,013 0,002 0,084 Totals 1,000 0,538 0,046 0,490 0,108 0,850 2.5 TEST FACILITY CONDITION Run Room Barometric Relative Number Temperature pressure humidity Air Velocity Before After Before After Before After Before After (F) (F) (in.hg) (in.hg) (%) (%) (ft/min) (ft/min) 1 70 71 29,412 29,471 39,7 34,3 22 24 2 68 71 30,209 30,209 34,5 29,5 21 22 3 69 70 30,209 30,121 34,5 29,9 24 26 4 67 78 29,884 29,737 33,2 29,6 23 21 Page 7 of 24

2.6 DILUTION TUNNEL FLOW RATE MEASUREMENTS AND SAMPLING DATA (SECTION 6.23 ASTM E2515) Average dilution tunnel measurements Sample Data Run Burn Volumetric Total Volume sampled Particulate catch Number Rate Flow Rate Temperatures (DSCF) (mg) (Min) (dscf/min) ( R) 1 2 1 2 1 244 173,63 657,29 41,633 40,280 6,50 6,70 2 242 170,91 598,77 41,645 40,352 4,20 4,70 3 247 181,69 561,30 42,442 41,074 3,60 3,30 4 247 186,91 554,93 42,806 41,279 2,50 2,60 2.7 DILUTION TUNNEL DUAL TRAIN PRECISION Run Sample Ratio Total Emission (g) Number Train 1 Train 2 Train 1 Train 2 % Deviation 1 1017,59 1051,78 6,61 7,05 3,17% 2 993,19 1025,01 4,03 4,68 7,42% 3 1057,37 1092,58 3,65 3,45 2,83% 4 1078,53 1118,43 2,38 2,59 4,26% Page 8 of 24

2.8 1 ST HOUR EMISSION & CO TOTAL EMISSIONS Run Number ASTM E2515 Emissions First Hour (gr/hr) CSA B415.1 CO emission (gr/hr) 1 1.73 7.62 2 0.60 30.27 3 1.48 35.2 4 0.86 26.21 St-jean-sur-richelieu, January 15th 2016 3 PROCESS DESCRIPTION 3.1 DISCUSSION The unit was received at the lab by a carrier during the month of September 2015, the preburn was done on the unit the week before official testing in December 2015 with the same pellet fuel. Appliance Manufacturer: America s Heat Model: AHB 170P Type: Automatic feed Pellet boiler Materials of Construction: The unit is constructed primarily of middle steel. The firebox has no refractory brick. The door has a no glass panel and one gasket. Internal Baffles: A Steel baffle is mounted in the upper portion of the firebox. The flame path is forced to the bottom of the firebox where it travels up through the opening between the baffle and front of the firebox. Other Features: na Flue Outlet: The 6-inch diameter flue outlet is located in the back of the unit. 3.2 AIR SUPPLY SYSTEM Air Introduction System: combustion air enters through the combustion air blower on the burner the lower row of hole in the burner is primary air and a second upper row of holes is the secondary combustion air. Combustion Control Mechanisms: Example: Combustion air is modulated by cycling the combustion fan speed. The fuel delivery auger is cycling as well, to achieve the different burn rate, one aquastat activate or turn off at the same time the auger and the combustion fan. Page 9 of 24

Combustor: No electric ignition is available in this model. 3.3 PROCESS OPERATION DURING TEST During the 1 st run (cat.4) we set the flow rate of the load to aim for the maximum power of 80 000 Btu/hr. The flow of the water in the heat exchanger was set at 8.2 liter/min., 2 hours before the beginning of the sampling and maintained during 4.07 hours for the test. The boiler delivers during the test an average of 77 750 Btu/hr, and reach the targeted output delivery category of the maximum burn rate. The unit at this burn rate category get 63.6 % delivery efficiency with 0.0476 lb/mmbtu output, 60.57 lbs of fuel have been consume with 6.8 gr total emission During this test the boilers combustion run at maximum. During the 2 nd run (cat. 3) we set the flow rate of the load to aim for the maximum power of 36 000 Btu/hr. The flow of the water in the heat exchanger was set at 3.1 liter/min., 2 hours before the beginning of the sampling and maintained during 4.03 hours for the test. The boiler delivers during the test an average of 36 900 Btu/hr, and reach the targeted output delivery category of the maximum burn rate. The unit at this burn rate category get 60.7 % delivery efficiency with 0.064 lb/mmbtu output, 29.9 lbs of fuel have been consume with4.4 gr total emission During this test the boilers combustion run at maximum. During the 3 rd run (cat. 2) we set the flow rate of the load to aim for the maximum power of 17 600 Btu/hr. The flow of the water in the heat exchanger was set at 1.26 liter/min., 2 hours before the beginning of the sampling and maintained during 4 hours for the test. The boiler delivers during the test an average of 14 300 Btu/hr, and reach the targeted output delivery category of the maximum burn rate. The unit at this burn rate category get 51.4 % delivery efficiency with 0.13 lb/mmbtu output, 14.0 lbs of fuel have been consume with 3.6 gr total emission During this test the boilers combustion run at maximum. During the 4 th run (cat. 1) we set the flow rate of the load to aim for the maximum power of 11 200 Btu/hr. The flow of the water in the heat exchanger was set at 0.7 liter/min., 2 hours before the beginning of the sampling and maintained during 4 hours for the test. The boiler delivers during the test an average of 10 350 Btu/hr, and reach the targeted output delivery category of the maximum burn rate. The unit at this burn rate category get 49.6 % delivery efficiency with 0.128 lb/mmbtu output, 10.5 lbs of fuel have been consume with 2.5 gr total emission During this test the boilers combustion run at maximum. Test fuel Test fuel: wood pellet ( model: Hotzpellets), Description: The pellet for each test and pre-burn period was sent to Twin ports Testing inc for test fuel calorific analysis. This laboratory is ISO/IEC 17025 recognize. For the test fuel property refer to test fuel analysis in the appendix D Calibration data. Sourcing: Pellet already at the laboratory from another project Handling and storage: keep all bags in the same room (at 20C ambient and 50% humidity) all wrap together to ensure the stability of the moisture. Page 10 of 24

3.4 START-UP OPERATION St-jean-sur-richelieu, January 15th 2016 The complete firing procedure of each burn rate category is fully described in appendix. 4 SAMPLING SYSTEMS 4.1 SAMPLING LOCATIONS Particulate samples are collected from the dilution tunnel at a point 15 feet from the tunnel entrance. The tunnel has two elbows and two mixing baffles in the system ahead of the sampling section. The sampling section is a continuous 10 foot section of 6 inch diameter pipe straight over its entire length. Tunnel velocity pressure is determined by a standard pitot tube located 48 inches from the beginning of the sampling section. Thermocouple is installed on the pitot tube to measure the dry bulb tempo MC is assumed, as allowed, to be 2%. Tunnel samplers are located 56 inches downstream of the pitot tube and 16 inches upstream from the end of this section. 4.2 DRAWINGS Various drawings of the stack gas sampling train and of dilution tunnel system are found in Appendix 9. 4.3 EMISSIONS EFFICIENCY TESTING EQUIPMENT LIST The complete test equipment list together with all corresponding calibration data can be found in Appendix D. 5 SAMPLING METHODS 5.1 PARTICULATE SAMPLING Particulates were sampled in strict accordance with ASTM E2515. This method uses two identical sampling systems with Gelman AIE 61631 binder free (or equivalent), 47 mm diameter filters. The dryers used in the sample systems are filled with "Drierite" before each test run. 6 QUALITY ASSURANCE 6.1 INSTRUMENT CALIBRATION 6.1.1 GAS METERS At the conclusion of each test program the gas meters are verified using the reference dry gas meter. This process involves sampling the train operation for 1 cubic foot of volume. With readings made to.001 fr', the resolution is.1 %, giving an accuracy higher than the 2% required by the standard. 6.1.2 STACK SAMPLE MASS FLOW CONTROLLER The stack sample mass flow meter regulates each flow rate used during the test program. The flow rate is acquisition every minute during the test run and use for the proportionality calculation. The dry gas meter volume measured is then corrected to standard temperature and pressure conditions. Page 11 of 24

6.1.3 GAS ANALYZERS St-jean-sur-richelieu, January 15th 2016 The continuous analyzers are zeroed and spanned before each test with NBS traceable gases. A mid-scale multi-component calibration gas is then analyzed (values are recorded). At the conclusion of a test, the instruments are checked again with zero, span and calibration gases (values are recorded only). The drift in each meter is then calculated and must not exceed 5% of the scale used for the test. At the conclusion of each unit test program, a three point calibration check is made and must meet accuracy requirements of the applicable standards. Consistent deviations between analyzer readings and calibration gas concentrations are used to correct data before computer processing. 6.2 TEST METHOD PROCEDURES 6.2.1 LEAK CHECK PROCEDURES Before and after each test, each sample train is tested for leaks. Leakage rates are measured and must not exceed 0.02 CFM or 4% of the sampling rate. Leak checks are performed checking the entire sampling train. Pre-test and post-test leak checks are conducted with a vacuum of 5 inches of mercury. Vacuum is monitored during each test and the highest vacuum reached is then used for the post-test vacuum value. If leakage limits are not met, the test run is rejected. During these tests, the vacuum is typically less than 2 inches of mercury. Thus, leakage rates reported are expected to be much higher than actual leakage during the tests. 6.2.2 TUNNEL VELOCITY FLOW MEASUREMENT The tunnel velocity is calculated from a center point pitot tube signal multiplied by an adjustment factor. This factor is determined by a traverse of the tunnel as prescribed in EPA Method 1. Final tunnel velocities and flow rates are calculated from EPA Method 2, Equation 6.9 and 6.10. (Tunnel cross sectional area is the average from both lines of traverse.) Pitot tubes are cleaned before each test and leak checks are conducted after each test. 6.2.3 PM SAMPLING PROPORTIONALITY (ASTM E2515) Proportionality was calculated in accordance with ASTM E2515. The data and results are in appendix. 6.2.4 HEAT OUTPUT MEASUREMENT With water-to-water heat exchanger, PT100 insertion probe (+-0.25 F) and flow meter within 0.5% accuracy. Page 12 of 24

Appendix A Unit Operating Procedures Page 13 of 24

Appendix B Raw data, forms and Results Page 14 of 24

Appendix C Drawing and specifications Page 15 of 24

Appendix D Equipment list and calibration certificates Page 16 of 24

Appendix E Unit pre-burn Page 17 of 24

Appendix F Operator's manual Page 18 of 24

Appendix G unlock data & calculation forms Page 19 of 24

Appendix H Proportionality results Page 20 of 24

Appendix I Test load photographs and fuel analysis Page 21 of 24

Appendix J photograph of the test setup Page 22 of 24

Appendix K Drawing of air and water flow pattern Page 23 of 24

Appendix L: example calculation Page 24 of 24