MVX-Series Diesel Engine Air Shut Down Valves

Similar documents
Diesel Engine Shutdown Valves

SVX-Series Solenoid Actuated Diesel Air Shut Down Valves

HVX-Series Diesel Engine Shut Down Valves (Oil Pressure Latched Types with Manual Start Override/Emergency Stop)

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

Diesel Engine Shutdown Valve

Solenoid Actuated Diesel Engine Air Shut Down Valves

SVX-Series Diesel Engine Shut Down Valves (Solenoid Latched Types with Manual Start Override/Emergency Stop)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Stop Types)

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run Types for Non-Hazardous Areas)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override)

SELECTION, APPLICATION AND MAINTENANCE

D-Series Automatic Engine Overspeed Shut Down Valves (Mini Range)

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

D200 Spindle Type Automatic Engine Overspeed Air Intake Shut Down Valve (including Manual, Oil and Air Pressure Shut Down Control options)

E-M Series. Combined Manual and Automatic Engine Overspeed Shut Down Valves

SELECTION, APPLICATION AND MAINTENANCE

Diesel Engine Shutdown System

E Series. Automatic Engine Overspeed Shut Down Valves

FS2 Valves. Solenoid Powered to Close / Auto Reset Butterfly Valves

Diesel Engine Safety Solutions. Automatic Engine Overspeed Shut Down Valves - D Series

Air Intake Shut-off Valve

Automatic Fuel Shut Down Valves

FS3 Valves. Solenoid Powered to Open / Spring to Close (failsafe)

World class manufacturer of safety solutions SYSTEM SELECTION GUIDE. Safety solutions for vehicles and machines working in petrochemical plants

System Selection Guide

Flameproof Alternators

PH1 AIR INTAKE EMERGENCY SHUT-OFF VALVE PULL CABLE ACTUATION.

SELECTION, APPLICATION AND MAINTENANCE

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDB3 Compact Butterfly Valve. by AMOT. Overview. Typical Applications

by AMOT World class diesel engine safety solutions Automatic Engine Overspeed Shut Down Valves - D Series

Intake Air Shut-off Valve

Diesel Engine Air Intake Shutoff Valves

Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

AIR INTAKE EMERGENCY SHUT-OFF VALVE C50203 AIR INTAKE SHUT-OFF VALVES APPLICATION DODGE 5.9L CUMMINS.

AIR INTAKE EMERGENCY SHUT-OFF VALVE PH2 C50204 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS.

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Optimise your temperature control

PH2 AIR INTAKE EMERGENCY SHUT-OFF VALVES. APPLICATION C ½ DODGE 6.7L CUMMINS C DODGE 6.

PH2 C50219A AIR INTAKE SHUT-OFF VALVE. T800 KENWORTH / ISX ENGINE WITH POWERGUARD SMART OVERSPEED LIMITER

Model J. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations available

AIR INTAKE EMERGENCY SHUT-OFF VALVE C50207 AIR INTAKE SHUT-OFF VALVES APPLICATION FORD 6.7L POWERSTROKE.

Metal Particle Detector

PH2 POWERHALT AIR INTAKE SHUT-OFF VALVE C50201A ½ DODGE 6.7L CUMMINS C50202A DODGE 6.

by AMOT World class diesel engine safety solutions Product Selection Guide

2-Way Temperature Sensing Valves

Pilot Operated 2-Way Gas Valves

E1186X Breather Kit. For Yanmar L48N Engines

Pneumatic Indicating Relay

3-Way Temperature Control Valve

Is the heart of your engine protected?

C50254A PH3 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS WITH POWERGUARD SMART OVERSPEED LIMITER

Model H. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations

Thermostatic Control Valves

Pressure and Temperature Switches

PH3 AIR INTAKE EMERGENCY SHUT-OFF VALVE WITH POWERGUARD SMART OVERSPEED LIMITER. Generic PH3 Truck Shut-Off Valve Kit.

Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

Flameproof Alternator

Thermostatic Control Valve

Thermostatic Control Valve

Y690A Series Pressure Reducing Regulators

Flameproof Alternator

Flameproof Alternator

M High Performance Power Transmission Couplings

type 122a three-way Switching Valve

SI unit. Supplementary unit unit. in Ib Ibf Ibfft psi qt(us) F. kg N Nm bar 1 C

SECTION 3.00 WARNING WARNING ENGINE STARTUP AND SHUTDOWN PRESTART INSPECTION

type 630r relief Valve

SEries 41 check valve installation, operation & maintenance manual

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

EXPLOSION PROOF. Diesel Engines For Hazardous Areas

Model E. Thermostatic Control Valves. Typical applications

Installation, Operation and Maintenance Manual DOC.IOM.MO.E October MO-Series Manual Override Gearboxes

Type 310A-32A Pressure Reducing Regulator

IMO-200EN 09/2010. Trunnion mounted forged ball valves Model FF and GG. Installation, Maintenance and Operating Instructions IMO-200EN 09/2010

M1/M2 POCKET FEEDER. Compact design DESIGN FEATURES. Special ball and seat design. Large ball pocket capacity. Automatic cycling

Self-Exciting Flameproof Alternator

Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual

Double Block & Bleed Pipeline Ball Valves Taurus Series

Control Valves. Type HP-10, 10,000 PSI. User Manual. RCV-UM EN-01 (August 2014)

2009 PCED Gasoline Engines SECTION 1: Description and Operation. Intake Air System

EXPLOSION PROOF. Diesel Engines For Hazardous Areas

Engineering Standard. Fig 707 Safety Relief Valve Installation and Maintenance Instructions

Bulk Liquid Filtration

TYPE HSFE/HLFE/HTFE H SERIES HIGH PERFORMANCE COUPLINGS

25198:- 1/31/12 11:24 AM Page 2 Filtration Systems

Series 500. Liquid Level Transmitters. Instruction Manual

289 Series Relief Valves

Preventive maintenance 4

Series 100 Slam Shut Valve

Metal Particle Detector

Shafer RV-Series Rotary Vane Valve Actuators Valve Operating Systems for Critical Pipeline Applications

NELES BO SERIES BUTTERFLY VALVE FOR RECOVERY OF OXYGEN IN VACUUM PRESSURE SWING ADSORPTION (VPSA) PLANTS

TYPE 7700D/7700W DOUBLE OPPOSED CARTRIDGE MIXER SEAL

TYPE HSRE/HLRE/HTRE H SERIES HIGH PERFORMANCE COUPLINGS

Bulletin: Floating Ball Valve. Tartarini Floating Ball Valve. Introduction. Features and Benefits

WHEATLEY Dual-Plate Wafer Check Valve. Space-saving design with a full bore for improved flow characteristics in backflow prevention applications

Y610A, Y611A, and Y612A Series Vacuum Service Equipment and Relief Valves

Combustion Gas Turbine Fuel Pumps. CIRCOR White Paper

Transcription:

MVX-Series Diesel Engine Air Shut Down Valves (Cable operated closure/integral reset lever types) Selection, Application and Maintenance SPECIAL VALVE MVX-304 This is a special version of valve type MVX-303 but with twin pull cables. The installation and maintenance instructions given for MVX-303 are otherwise generally applicable. Valve Numbers MVX-301 MVX-302 MVX-303 MVX-501 MVX-502 MVX-503 MVX-801 MVX-802 MVX-803 page 1

DESCRIPTION A range of mechanically actuated diesel engine air intake closure valves based on standard Chalwyn 3, 5 and 8 butterfly valves. Suitable for both hazardous and non-hazardous area applications where a cable operated stop control combined with a valve mounted reset lever is required. Available in basic flange mounted form or fitted with hose adaptors or an integral flame trap housing. Body and disc manufactured in corrosion resistant hard anodised aluminium with PTFE coating. Spindle and mechanism made from 316 stainless steel. Typical Arrangement: Valve Types MVX-301, MVX-501 and MVX-801 Typical Arrangement: Valve Types MVX-302, MVX-502 and MVX-802 page 2

Typical Arrangement: Valve Types MVX-303, MVX-503 and MVX-803 Main Dimensions (mm) Valve Types MVX-301 MVX-302 MVX-303 MVX-501 MVX-502 MVX-503 MVX-801 MVX-802 MVX-803 Nominal Bore Diameter 76 (3 ) 127 (5 ) 203 (8 ) A 190.0 190.0 223.0 246.0 246.0 279.0 346.5 346.5 377.5 B 111.5 167.0 257.0 C 1 37.5 45.5 56.0 C 2 minimum & maximum 82.5 to 112.5 102.0 to 157.5 136.5 to 185.5 Note: Maximum temperature of the engine intake air at the MVX valve not to exceed 150 C. (See also Installation - page 5). page 3

SELECTION Determine the size and position of the MVX valve to be installed. Within the various constraints imposed by the application, the valve should be as generously sized as possible Check that the valve can be positioned such that the reset lever will be easily and safely accessible and that a reasonably straight run is available for the shut down cable. Select the cable length required from the options listed below. Remote Push Button and Cable options for use with PULL Cable Assembly Options (to suit valves Handle RTD-100 (To suit valves MVX-301/302, MVX-501/502 or MVX- MVX-303, MVX-503, or MVX-803) 801/802) Assembly part No. Length (meters) Cable part No. Length (meters) RBC--100 1.0 RBC-150 1.5 RBC-200 2.0 RBC-300 3.0 Select the required length of the manual shut down cable from the table. Alternative lengths may be available on request. CLD-100 1.0 CLD-150 1.5 CLD-200 2.0 CLD-300 3.0 Select the required length of the manual shut down cable from the table. Alternative lengths may be available on request. Also order handle RTD-100. If the valve is to be fitted into a hose as opposed to flange mounted, suitable hose adaptors may be selected from the table below for ordering with the valve. Hose Adaptor Options 76mm (3 ) Bore Valves Adaptor To Suit Hose Bore Part Number mm (inches) HAX-320 38 ( 1 1 / 2 ) HAX-322 44.5 (1 3 / 4 ) HAX-301 51 (2) HAX-303 57 (2 1 / 4 ) HAX-304 60 (2 3 / 8 ) HAX-305 63.5 (2 1 / 2 ) HAX-306 67 (2 5 / 8 ) HAX-307 70 (2 3 / 4 ) HAX-309 76 (3) HAX-312 82.5 (3 1 / 4 ) HAX-314 89 (3 1 / 2 ) HAX-319 102 (4) 127mm (5 ) Bore Valves Adaptor To Suit Hose Bore Part Number mm (inches) HAX-501 89 (3 1 / 2 ) HAX-503 95 (3 3 / 4 ) HAX-505 102 (4) HAX-507 108 (4 1 / 4 ) HAX-509 114 (4 1 / 2 ) HAX-511 121 (4 3 / 4 ) HAX-513 127 (5) HAX-518 140 (5 1 / 2 ) HAX-523 152 (6) 203mm (8 ) Bore Valves Adaptor To Suit Hose Bore Part Number mm (inches) HAX-807 178 (7) HAX-808 203 (8) page 4

INSTALLATION 1. In the case of a naturally aspirated engine, the Chalwyn MVX shut down valve should generally be fitted as close to the engine air intake manifold as possible. If an intake flame trap is also fitted, the MVX valve must be installed upstream (air cleaner side) of the flame trap. 2. To avoid excessively high intake air temperatures at the MVX valve when fitted to a turbocharged engine, it may be necessary to fit the MVX valve either upstream of the turbocharger or downstream of the intercooler (where fitted). Again, if an air intake flametrap is also fitted, the valve must be installed upstream of the flametrap. 3. Where more than one MVX valve is installed on an engine, as in the case of an engine with multiple intake pipes, the shut down valves must be arranged to all close simultaneously. an external breather system venting either to atmosphere or to the intake system upstream of the shut down valve. External breather system kits for various engine types are available from Chalwyn. 8. For values with the pull handle cable operated manual shut down, fit the T handle assembly RTD-100 through a suitable Ø20mm (3/4 dia) hole in a bulkhead or mounting bracket as follows. Release the handle locknut. Remove the handle,handle locknut and upper locknut and washer. Thread handle body through the bulkhead/bracket. Refit upper locknut and washer. Adjust lower and upper locknuts to position handle and tighten. Refit handle locknut and handle. Tighten locknut. 4. The valve may be installed either horizontally or vertically. 5. If hose adaptors are used, the mating hose should be of a reinforced type, provide adequate support for the valve and prevent excessive vibration. If necessary, additional support brackets mounted from the engine should be considered. 6. Particular care must be taken to ensure the integrity of the intake pipework between the Chalwyn valve and intake manifold. Ideally metal pipework should be used and any gaps kept as short as possible, (taking into account any relative movement) and closed by reinforced hose. The possibility of a hose collapse on closure of the shut down valve must be avoided. 7. Any engine crankcase breather connections into the intake system between the MVX valve and engine, or any internal crankcase breather arrangement venting directly into the engine intake ports must be sealed and replaced by page 5

OPERATION Prior to starting the diesel engine, the MVX valve must be latched open by rotating the reset lever clockwise as far as possible. Once latched, the reset lever will remain in the latched open position until manually released by the remote stop button. To carry out an emergency closure of the MVX intake valve to stop the engine, operate the manual stop control. No attempt should then be made to restart the engine until the MVX valve is again latched open. MAINTENANCE MONTHLY: Check that the fasteners locating the MVX valve and any associated intake systems or support bracket fasteners are securely tightened. Check that any flexible hoses between the MVX valve and engine are free from damage and suitable for further service. Run engine, preferably at low idle. Operate the stop button. The engine should stop within a few seconds. If not, check that the shut down cable is properly adjusted and that there are no leaks in the intake system between the MVX valve and the engine. If this does not resolve the problem, remove the MVX valve and return to Chalwyn for further investigation. page 6

page 7

Americas Asia Pacific Europe, Middle East and Africa AMOT - USA Tel: +1 281 940 1800 Fax: +1 713 559 9419 info@amotusa.com AMOT - China Tel: +86 (0)21 6279 7700 Fax: +86 (0)21 5237 8560 shanghair@amot.com AMOT - UK Tel: +44 (0)1284 715739 Fax: +44 (0)1284 715747 info@amot.com Roda Deaco by AMOT - Canada Tel: +1 780 465 4429 Fax: +1 780 469 6275 info@rodadeaco.com AMOT Singapore Tel: +65 6408 6265 Fax: +65 6408 6266 singapore@amot.com AMOT - Germany Tel: +49 (0)40 8537 1298 Fax: +49 (0)40 8537 1331 germany@amot.com AMOT - Russia Tel: +7 495 617 12 96 Fax: +7 495 913 97 65 russia@amot.com www.chalwyn.com by AMOT