The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers:

Similar documents
INSTALLATION & MAINTENANCE MANUAL HBL

PIL0478 ISSUE 01/ 07/16

GP12 TECHNICAL MANUAL

SUBMERSIBLE PUMP. Model No: HIPPO 2 OPERATING & MAINTENANCE INSTRUCTIONS

SUBMERSIBLE WATER PUMP

28W WORK LAMP Model: CTL28 Part No:

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

18W Round LED Slimline Emergency Light

LEAD ACID BATTERY CHARGER

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

Pack Cat. Nos. Single pole push switches gang 2 way push switch gang 2 way push switch marked PRESS gang 2 way

ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011

Element C8.3 Installation, Use and Inspection of Electrical Systems

DALI 650mA LED Driver

EC200 ELECTRONIC CONTROL SYSTEM

EC400 Power Control System

S HINE V ENTURE L IGHTING S LED LAMPS. Quality retrofit LED lighting products from a leader in the lighting industry. Full range dimming

SUBMERSIBLE WATER PUMPS

BRIDGE HARDWARE (WHOLESALE SUPPLIES) Tel: Fax: PRODUCT GUIDE

Dedicated PIR Light Controller c/w RF remote control for LEDPRO Floodlights

OPERATION & MAINTENANCE INSTRUCTIONS

1000mA - 650mA Phase Dimmable LED Driver

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

Installation Instructions

10W LED Die Cast Small Rectangle Bulkhead Light

EC400 / EC450 series Power Control System

SUBMERSIBLE PUMP HSE RANGE

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

pond and garden 3 x 1 watt / 5 x 1 watt

OPERATION & MAINTENANCE INSTRUCTIONS

Technical Data. Dimmer Switches - Push Type 881P/885P 882P 883P 884P

Installation Instructions

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

SUBMERSIBLE WATER PUMP

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

Getting started with

2x 10W LED Slimline Floodlight Twin Flood

SUBMERSIBLE PUMP HSE RANGE

INFRESCO-S-4kW X20034 Issue: 7

USER MANUAL PNEUMATIC TIME DELAY SWITCH

Dimmer / 2-Way Dimmer

SUBMERSIBLE WATER PUMP

650mA Phase Dimmable LED Driver

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032

25W LED Cross Bezel Bulkhead Light

Model: ECO1FL Model: ECO2FL Model: ECO3FL. Installation & Operating Instructions ECO CFL Flood Light Uncontrolled

Installation Instructions

I n s t a llat ion & O p e r atin g In s truc t ions

ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET

Initial and Periodic Inspection and Testing of Electrical Installations ( ) Sample Test

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

EC225 Power Control System

3000W Dusk to Dawn Light Controller

PROFESSIONAL 270 o PIR MOTION DETECTOR

Adjustable Pneumatic Time Delay Switch

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. System Universal LED dimming insert Standard

LED Lamp. Halogen Lamp

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Interior Lighting. t: e: w: detaelectrical.co.uk

Installation & Operation Instructions. Deluxe LED Spot Light

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

ASSEMBLY & FITTING INSTRUCTIONS P-LUX3 LED TRI-SENSOR LANTERN

Installation & User Instructions

Sprite Lite. Specification, Wiring Diagrams, Bulb Chart and Electrical Control Panel Information

PANELS STRIPS LAMPS DOWNLIGHTS DRIVERS

2-Way Dimmer (1 Gang)

OPERATION & MAINTENANCE INSTRUCTIONS

POND PUMP Model Nos:SPP3 & SPP6 0200

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

6 x 10 Belt Disc Sander

Safety Lampholders and Pendants

MK Electric IP Solutions

SubDrive Inline Constant pressure controller Additional information for Australia, NZ TOLL FREE HELP 1300 FRANKLIN

Horizon Colour Coated Matt Black Square Corners Data Sheet

Installation Instructions for direct line voltage connection / Basic / SubstiTUBE Value Advanced ST8-HV / ST8-HB / ST8-HA

INSTALLATION & OPERATING MANUAL LIGHT SABER LED SHAFT LIGHTING SYSTEM EN81-20 INNOVATION NOT IMITATION!

Rada Outlook 150, 190 & 225mm Sensor Spout. For wall panel installation PRODUCT MANUAL

OPERATION & MAINTENANCE INSTRUCTIONS

- Wiring Brochure Zone Manager 336

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

Modern Soft Edged White Moulded Wiring Accessories

FINAL-ER 42 Electrician Regulations Answer Schedule

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University

Horizon Antique Brass Square Corners Data Sheet

StarEye. 350 ma version. No control electronics on board

12 amp RMS Battery Charger

PSX-240 Enclosed Autotransformer Installation Manual

Installation Instructions

OPERATION & MAINTENANCE INSTRUCTIONS

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

MODEL Nos: CVAC20SS CVAC25SS CVAC30SSR OPERATING & MAINTENANCE INSTRUCTIONS. Distributed by CLARKE International Ltd.

GL1200T Cut & Seal. (GL1200 Seal only)

BATTERY STARTER/CHARGER MODEL NO: BC125, BC190

CFT24 &CFT230 PART NOS:

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

2-Way Dimmer (1 Gang)

Air duct switching damper

Transcription:

TT402 (300W) Incandescent Wireless receiver Inline Dimmer Product Description The TT- 402is a 40-300W dimmable wireless receiver. It can be paired with only circuits 1 and 2 (keys 4 or 5) on the Taptile Bathroom Sensor. Product Compatibility The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers: LED lighting of any kind G23, Metal Halide High Pressure sodium, CLF, Linear/Compact Fluorescents, SLE- PRO, PLE- C Pro, Single Ended High Pressure Lamps The TT- 402Wireless Inline Dimmers are COMPATIBLE with the following lighting types: G9 Strip & Architectural PAR30 PAR36 SES (Candle/Round PAR38 PAR20 GLS BC GLS ES GU10 SBC (Candle/Round) K1/9/11/12 G4 G6.35 MR16 MR11

Product specification TT402 Wireless Inline Dimmer: Input: 230V ~ 50Hz Fused: 1.6A Min load 40W (Loads below 40W will cause unstable operation) Max Load: 300W Indoor Use Only Frequency: 433.92MHz Warning: Never Exceed the Product Specification INSTALLATION WARNING: BEFORE COMMENCING INSTALLATION ISOLATE YOUR MAINS ELECTRIC SUPPLY Always read the instructions carefully before starting any installation and keep them for future reference. If you are in any doubt on the installation process, consult a qualified electrician. This product should be installed in accordance with the relevant sections of the building regulations code, and the current edition of the IEE Wiring Regulations (BS 7671: Requirements for electrical installations) and appropriate statutory regulations. Do not install ceiling receivers on lighting circuits used to supply other products such as extractor fans and shaver socket outlets. Do not exceed the Wireless Inline Dimmer s Maximum Power Rating of 300W. As of 1st April 2004, new installations in the UK should be wired using the EU harmonised colours for the supply conductors: New colours: Old colours: BROWN = Live BLUE = Neutral Earth = Yellow/Green RED = Live BLACK = Neutral The old colours will cease from April 2006. Electrical installations in bathrooms, kitchens, gardens, floor and heating systems, swimming pools, saunas and extra- low voltage lighting are classed as special installations and must be certified by an approved competent electrical contractor conforming to Part P, requirements of BS 7671:2001 and appropriate statutory regulations.

Installation Notes When installing TT402 Wireless Inline Dimmers in an existing lighting circuit, conventional light switches should be disconnected and terminated as part of the installation If your lighting circuits using ceiling roses, it is recommended that the current wiring connections should be re- terminated using a suitable junction box. The Taptile Wireless Inline Dimmer is designed to be connected to the existing permanently live lighting circuit between a convenient junction box and the light fitting. Any existing switches currently controlling the light fitting should be disconnected and appropriately terminated. Lighting circuits supplying Ceiling Receivers should always be protected by a 5 Amp rewire- able fuse or equivalent Miniature Circuit Breaker (MCB) located in the Consumer Unit. Under no circumstances should any protection devices with higher ratings be used. ** Wireless Inline Dimmers are not designed to be used with loop- in/loop- out wiring, a suitable junction box needs to be used if it s necessary to connect the supply to further fittings; the Taptile Sensor is designed for permanent installation. The TT402 Wireless Inline Dimmers are designed to be mounted inside a suitable enclosed housing, which are dry and adequately ventilated (indoor use). For outdoor use a suitable IP56 enclosure must be used. The Wireless Inline Dimmer is designed to be maintenance free, but where possible access should be available when needed. You will now need to pair the TT402 with the Taptile Sensor Please refer to your Taptile installation manual for the pairing procedure If in any doubt consult a qualified Electrician WARNING: Before installing the Taptile Wireless Inline Dimmers, isolate the circuit at the fuse/mcb board. Connect the supply Live and Neutral conductors to the Receiver terminals marked L and N SUPPLY. Connect the cable from the light fitting to the Receiver terminals marked L (Load) and N (Neutral). For earth continuity the supply and load Earth conductors must be terminated externally using a suitably insulated terminal block.

Changing the Fuse The TT402 is fuse protected, to change the fuse: 1. Isolate the mains power supply from the Wireless Inline Dimmer. 2. Using a small screw driver, remove the fuse holder and replace the fuse with a new 1.6A fuse. 3. Replace the fuse holder and reconnect the mains supply. Interference Occasionally interference from receiver sockets plugged into adjacent wall sockets or when used with transformers (low voltage products) can affect the operating range. Try placing one of the receiver sockets in another wall socket. For low voltage products the transformer should be sited as far away from the receiver socket as possible. RF Range The radio signals operating distance is reduced when the signal has to pass through walls or ceiling. The radio signals will reduce significantly with foil coated ceilings, or metallic- coated loft insulation. Please consider placement, and allow for potential movement if radio reception is an issue.

Please refer to the following diagrams for typical installations:

Warranty Taptile and Taptile Controls are registered trademarks of GPEG International Ltd. All Taptile products are fully CE compliant and accredited by Intertek Ltd. All products in the Taptile range come with a fixed two (2) year warranty from date of purchase. During the period of the warranty, GPEG International Ltd will arrange for the faulty parts to be repaired or (at our discretion) replaced. Any faulty parts must be returned with proof of purchase to the place of purchase for exchange. The Taptile system has been ingeniously designed to ensure that, so long as the installation guide is followed, all parts should be serviceable and the Taptile sensor itself can be easily replaced by the removal of only one tile keeping any remedial costs to a minimum. GPEG shall not be responsible for:- Damage or repairs required as a consequence of faulty installation or application Damage as a result of floods, fires, winds, lightning, accidents, corrosive environment or other conditions beyond the control of GPEG Use of components, fittings or accessories not compatible with the Taptile Sensor Products installed outside of the United Kingdom Damage caused by installation outside of that detailed in the installation and operating manual Damage or incorrect operation caused by parts not supplied or designated by GPEG Damage or repairs required as a result of any improper use, maintenance, operation or servicing Incorrect operation of damage to parts caused by out of specification or unstable electrical supply Damage caused through lack of protection by an RCD at all times Changes in the appearance of the product that does not affect its performance Incidental or consequential damages, including, but not limited to extra utility expenses or damages to property and interiors. The cost of repair or replacement of the product is your only remedy under this Warranty which does not affect your statutory rights. Such cost does not extend to any cost other than the direct cost of repair or replacement by GPEG and does not extend to the costs associated with retiling, rewiring, plastering or any other remedial work.