ANEXO 1: Ficha técnica de paneles fotovoltaicos

Similar documents

X-SERIES SOLAR PANELS

Staff Review Date: March 11, 2015 HDC

E-SERIES RESIDENTIAL SOLAR PANELS

Renewable Energy Product & Parts Catalog

More Energy. For Life. Maximise your energy production with SunPower.

Changing the way our world is powered.

International Product & Parts Catalog

Key Largo Wastewater Treatment District Board of Commissioners Meeting Agenda Item Summary

/ The personal storage solution for 24 hours of sun. / Ready for Storage

SPG-400. Solar-powered generators

18.6% 0-5w. Years. Grid. Certification. BYD PV Module 25 Years Linear Performance Warranty

Technical specifications

Maximize your ROI. Conext CL-60 String Inverter. The ideal solution for decentralized power plants and commercial rooftops

More energy. For your family. Go solar with SunPower.

P H O T O V O LTA I C

10KW 3 Phase Off Grid Hybrid System

INVERTER. MECHANICAL DATA Steel with powder paint Dimension (mm) 527 x 228 x 190 Net Weight (kgs) 18 STANDAR. Cont output power at 20ºC. Cos φ 0.

Current Automation Catalogue Page 27

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

X600. Technical Sheet

Details and specification for 30 W solar powered LED street lights.

EnergyCell FLA Series. Owner s Manual

1250W APS X Series 12VDC 230V Inverter/Charger with Auto Transfer Switching, 2 C13 Outlets

250 Watt. Features. Positive tolerance Positive tolerance of up to 5% delivers higher outputs reliablity

3 Phase Power Systems - Designed for Canada

MODEL NUMBER: APS2448UL

3000W APS X Series 24VDC 230V Inverter/Charger with Pure Sine-Wave Output, Hardwired

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

Wind Energy System.

KIT SOLAR MONTE PERDIDO

2400W APS INT Series 24VDC 230V Inverter/Charger with Auto-Transfer Switching, Hardwired

40 Módulos FV TRINA SOLAR 265Wp Policristalino (Estructura Incluida) 1 Inversor KACO Blueplanet 10,0 TL3

MODEL NUMBER: APS2424

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

TSM-DC01A. The Solution NEW. linear performance warranty. Module can bear snow loads up to 5400Pa and wind loads up to 2400Pa

K50. Technical Sheet

MODEL NUMBER: APS2012

400W / 600W / 1000W / 1500W DIY Wind Turbine

Conergy PH 185M 200M. Special Edition Australia. Specifications Photovoltaic modules

ENERGY STORAGE SOLUTIONS

750W PowerVerter RV Inverter/Charger with Hardwire Input/Output

Versatile and Rugged Industrial LIthium/LiPO Charger Series

Sail Away with Peace of Mind. Dolphin Series II Smart Battery Chargers

AC MODULE P72PCS-300W

Warranty on production defects: 12 years WP YEARS WARRANTY. CLASS 1 CLASS 1 Reaction to fire according to the UNI 9177 UNI standard IEC 61215

User Manual. Solar Charge Controller 3KW

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

SAMPLE PERMIT APPLICATION PACKAGE

INDEX. 3 BOREHOLE DC SOLAR PUMPS 3LLS...4 PERIPHERAL VANE DC SOLAR PUMP 3LSQB2...6

672W Off Grid Residential Package

General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07

K10. Technical Sheet

Ampd Silo. Energy Storage System. Maintenance-free Li-ion energy storage for mission critical backup. Power to Empower

Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS COMMERCIAL VEHICLES BACKUP POWER

MODEL NUMBER: APS3636VR

RES OPzV Premium Quality Batteries. for Renewable Energy Storage

RES OPzV Premium Quality Batteries. for Renewable Energy Storage

12-Batteries and Inverters. ECEGR 452 Renewable Energy Systems

AMERICAN MADE X SERIES LED SOLAR LIGHTING SYSTEM: X-3640-LED-185-T

X400. Technical Sheet

Power Inverter 400 MW Owner s Manual

User Manual Solar Charge Controller 3KW

Batteries and more. Powered by (CE, UL & ISO9001 APPROVAL)

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

Owner s Manual. Contents GP-PWM-30-SQ GP-PWM-30-SQ

1250W 12VDC PowerVerter Ambulance/EMS Inverter/Charger with 2 Hospital Grade Outlets

Owner s Manual. Contents GP-PWM-10-SQ

LOT Kwp Solar PV Power Solution with Battery Backup

PowerVerter 750W RV Inverter/Charger with Hardwire Input/Output

Chapter 3. Direct Current Power. MElec-Ch3-1

Section 7: Price Schedule Form 1

Sail Away with Peace of Mind. Dolphin Series II Smart Battery Chargers

Designing Stand Alone Systems. Overview, components and function, Elements in Design

FULLY CERTIFIED ON-TIME DELIVERY ATEC GRP ENCLOSURES

NorthStar Battery Company DCN: SES DCR: 1548-S09 Date:

Solar-Wind. Solar-Wind Hybrid LED Street light. Advantages and Benefits

SPECIAL SPECIFICATION 6576 Solar Panel Power Supply System

SUBSTATION EQUIPMENT - Page 1 of 8

CALL FOR A QUOTE (877)

MODEL NUMBER: APS750. Highlights. Package Includes. Description

INVERTER/CHARGERS Off-Grid Power Solutions

EFFEKTA Power Supplies

SAFE AND RELIABLE POWER FOR MARINE APPLICATIONS MEMBER CERTIFIED. The World Depends on Sensors and Controls

Solardyne Corporation Renewable Home Power Design Guide Call

: Next Generation Solar LED Solution

3.6 Kwp Solar system Supply, Installation, Commissioning & Maintenance of Solar Systems to YEMAC office in HADDA street, Sana a city

Pure Sine Wave Inverter Charger

DEGERtracker 3000HD / 3000NT / 5000NT Long-term power supplier. DEGERtracker - Dual-axis tracking system

ENERGY STORAGE SOLUTIONS

Switchgear Utility specific gravity nominal sulfuric acid. 10 years, full float service at 77 F (25 C)

FEATURES & benefits. Constant Power Discharge Ratings - Watts per 77 F (25 F) Operating Time (in minutes) to 1.

Technical standard for AC, DC and street light systems

LG Energy Freedom Solution

RFQ-YEM Solar Lighting System for UNDP

Tubular Flooded (OPzS) Batteries

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

Solar Inverter Manual

PowerSafe OPzV Operation Guide for Solar Applications

Transcription:

ANEXOS

Índice de anexos Anexo 1 Ficha técnica de paneles fotovoltaicos Anexo 2 Ficha técnica de aerogenerador Anexo 3 Ficha técnica de baterías Anexo 4 Ficha técnica de inversor

ANEXO 1: Ficha técnica de paneles fotovoltaicos

] E-Series Residential Solar Panels SunPower E-Series Residential Solar Panels E20-327 More than 20% Efficiency Ideal for roofs where space is at a premium or where future expansion might be needed. High Performance Delivers excellent performance in real-world conditions, such as high temperatures, clouds and low light. 1,2,4 High Performance & Excellent Durability 20 Proven Value Designed for residential rooftops, E-Series panels deliver the features, value and performance for any home. Maxeon Solar Cells: Fundamentally better Engineered for performance, designed for durability. Engineered for Peace of Mind Designed to deliver consistent, trouble-free energy over a very long lifetime. 3,4 Designed for Durability The SunPower Maxeon Solar Cell is the only cell built on a solid copper foundation. Virtually impervious to the corrosion and cracking that degrade conventional panels. 3 #1 Rank in Fraunhofer durability test. 9 100% power maintained in Atlas 25+ comprehensive durability test. 10 High Efficiency 5 Generate more energy per square foot E-Series residential panels convert more sunlight to electricity by producing 31% more power per panel 1 and 60% more energy per square foot over 25 years. 1,2,3 High Energy Production 6 Produce more energy per rated watt High year-one performance delivers 7 9% more energy per rated watt. 2 This advantage increases over time, producing 20% more energy over the first 25 years to meet your needs. 3 25-Year Energy Production / Watt Year 1 Energy Advantage / Watt 120% 110% 100% 90% 80% 70% 60% 8% more, year 1 SunPower E-Series Conventional 20% 00 More Energy Per Rated Watt 50% 0 5 10 15 20 25 Years 10% 8% 6% 4% 2% 0% SPR-E20-327 Maintains High Power at High Temps No Light-Induced Degradation High Average Watts Better Low-Light and Spectral Response High-Performance Anti-Reflective Glass 35% more, year 25 Datasheet

E-Series Residential Solar Panels SunPower E-Series Residential Solar Panels E20-327 SunPower Offers The Best Combined Power And Product Warranty 100% Power Warranty Product Warranty 95% 90% SunPower SunPower 85% 80% Traditional Warranty Traditional Warranty 75% Electrical Data SPR-E20-327 SPR-E19-320 Nominal Power (Pnom) 11 327 W 320 W Power Tolerance +5/ 0% +5/ 0% Avg. Panel Efficiency 12 20.4% 19.9% Rated Voltage (Vmpp) 54.7 V 54.7 V Rated Current (Impp) 5.98 A 5.86 A Open-Circuit Voltage (Voc) 64.9 V 64.8 V Short-Circuit Current (Isc) 6.46 A 6.24 A Max. System Voltage Maximum Series Fuse Power Temp Coef. Voltage Temp Coef. Current Temp Coef. 0 5 10 15 20 25 Years Conventional panel linear warranty More guaranteed power: 95% for first 5 years, 0.4%/yr. to year 25 7 600 V UL & 1000 V IEC 15 A 0.38% / o C 176.6 mv / o C 3.5 ma / o C REFERENCES: 1 All comparisons are SPR-E20-327 vs. a representative conventional panel: 250 W, approx. 1.6 m², 15.3% efficiency. 2 Typically 7 9% more energy per watt, BEW/DNV Engineering SunPower Yield Report, Jan 2013. 3 SunPower 0.25%/yr degradation vs. 1.0%/yr conv. panel. Campeau, Z. et al. SunPower Module Degradation Rate, SunPower white paper, Feb 2013; Jordan, Dirk SunPower Test Report, NREL, Q1-2015. 4 SunPower Module 40-Year Useful Life SunPower white paper, May 2015. Useful life is 99 out of 100 panels operating at more than 70% of rated power. 5 Second highest, after SunPower X-Series, of over 3,200 silicon solar panels, Photon Module Survey, Feb 2014. 6 8% more energy than the average of the top 10 panel companies tested in 2012 (151 panels, 102 companies), Photon International, Feb 2013. 7 Compared with the top 15 manufacturers. SunPower Warranty Review, May 2015. 8 Some restrictions and exclusions may apply. See warranty for details. 9 5 of top 8 panel manufacturers tested in 2013 report, 3 additional panels in 2014. Ferrara, C., et al. "Fraunhofer PV Durability Initiative for Solar Modules: Part 2". Photovoltaics International, 2014. 10 Compared with the non-stress-tested control panel. Atlas 25+ Durability test report, Feb 2013. 11 Standard Test Conditions (1000 W/m² irradiance, AM 1.5, 25 C). NREL calibration Standard: SOMS current, LACCS FF and Voltage. 12 Based on average of measured power values during production. 13 Type 2 fire rating per UL1703:2013, Class C fire rating per UL1703:2002. 14 See salesperson for details. Tests And Certifications Standard Tests 13 UL1703 (Type 2 Fire Rating), IEC 61215, IEC 61730 Quality Certs ISO 9001:2008, ISO 14001:2004 EHS Compliance RoHS, OHSAS 18001:2007, lead free, REACH SVHC-163, PV Cycle Sustainability Cradle to Cradle (eligible for LEED points) 14 Ammonia Test IEC 62716 Desert Test 10.1109/PVSC.2013.6744437 Salt Spray Test IEC 61701 (maximum severity) PID Test Potential-Induced Degradation free: 1000 V 9 Available Listings UL, TUV, JET, MCS, CSA, FSEC, CEC Operating Condition And Mechanical Data Temperature 40 F to +185 F ( 40 C to +85 C) Impact Resistance Appearance Solar Cells Tempered Glass Junction Box Weight Max. Load Frame 1046 mm [41.2 in] 0 5 10 15 20 25 Years Combined Power and Product defect 25 year coverage that includes panel replacement costs 8 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Class A 96 Monocrystalline Maxeon Gen II High-transmission tempered anti-reflective IP-65, MC4 compatible 41 lbs (18.6 kg) G5 Frame: Wind: 62 psf, 3000 Pa front & back Snow: 125 psf, 6000 Pa front G3 Frame: Wind: 50 psf, 2400 Pa front & back Snow: 112 psf, 5400 Pa front Class 1 black anodized (highest AAMA rating) 1558 mm [61.3 in] 46 mm [1.8 in] G5 FRAME PROFILE InvisiMount TM Compatible 46 mm [1.8 in] 30 mm [1.2 in] G3 FRAME PROFILE Not InvisiMount Compatible 46 mm [1.8 in] 32 mm [1.3 in] LONG SIDE 22 mm [0.9 in] SHORT SIDE See www.sunpower.com/facts for more reference information. For more details, see extended datasheet: www.sunpower.com/datasheets. G5 frames have no mounting holes. Please read the safety and installation guide. Document # 504860 Rev E /LTR_US March 2016 SunPower Corporation. All rights reserved. SUNPOWER, the SUNPOWER logo, MAXEON, SIGNATURE and InvisiMount are trademarks or registered trademarks of SunPower Corporation. Specifications included in this datasheet are subject to change without notice.

ANEXO 2: Ficha técnica de aerogenerador

Patent Pending SPECIFICATIONS Sphere of Operation Top View 24.5 inch radius 61 cm 26.6 inches (67.5 cm) 46 inches (1.15 cm) 22.5 inches (56 cm) Minimum Safe Pole Length Above Obstructions 2.0 inches 50 mm Rotor Diameter: Weight: Mount: Start-up wind speed: Voltage: Rated Power: Turbine Controller: Blades (three): Body: Kilowatt hours per month: Warranty: Survival Wind speed: Over-speed Protection: Power Output (Watts) 46 inches (1.15m) 13 lbs (5.85kg) (Shipping: 27 x15 x9 (686x38x228mm) / 17 lbs (7.7kg)) 1.5 schedule 40 pipe (1.9 OD, 48 mm) 7 mph (3.13 m/s) 12 and 24 VDC (36 and 48 VDC available soon) 400 watts at 28mph (12.5m/s) Microprocessor-based smart internal regulator with Peak Power Tracking Carbon Fiber Composite Cast aluminum (Air-X Marine is powder coated for corrosion protection) 38 kwh/mo @12mph (5.4m/s) 3 Year Limited Warranty 110 mph (49.2 m/s) Electronic torque control Performance Curves (preliminary*) 500 400 300 200 100 0 mph 5 10 15 20 25 30 35 40 45 m/s 2.3 4.5 6.8 9.0 11.3 13.5 15.8 18.0 20.3 Instantaneous Wind Speed Top Line - Non-Turbulent Site Bottom Line - Turbulent Site *derived from field and wind tunnel testing Monthly Energy Output (kwh) Southwest Windpower Renewable Energy Made Simple (928) 779-9463 www.windenergy.com 70 60 50 40 30 20 10 0 mph 4 6 8 10 12 m/s 1.8 2.7 3.6 4.5 5.4 Annual Average Wind Speed 14 6.3 Rayleigh Distribution Curve k=2 02SWP017

ANEXO 3: Ficha técnica de baterías

Power. Sheet. CR-430 Commercial Deep Cycle Crown Battery Manufacturing s team of research and development engineers welcome the opportunity to discuss your technical requirements during the design and specification stage. To access this technical assistance, please contact: Crown Battery Manufacturing s Product Support Department +1.419.334.7181 sales@crownbattery.com Fax +1.419.334.7124 AVAILABLE TERMINAL STYLES: Standard VENT CAP OPTIONS: White Standard Spin Vent SPW Manifold Vent PHYSICAL SPECIFICATIONS BCI Group Size Model Description Nominal Voltage Length Width Container Height Terminal Height Weight Cover & Container Material Case to Cover Seal Method in mm in mm in mm in mm lbs kgs 903 CR-430 6 12.38 314 7.19 183 15.29 388 16.13 410 122 55.3 Polypropylene Plastic Heat Seal ELECTRICAL SPECIFICATIONS Ampere Hour Capacity (Ah) Discharge Capacity Minutes KWH (kwh) Internal Resistance 100 Hr 72 Hr 48 Hr 20 Hr 10 Hr 5 Hr 2 Hr 100A 75A 50A 25A 10A 100 Hr 80 F / 27 C 525 490 460 430 355 340 256 165 240 391 904 2735 3.150 8.1mΩ CHARGING INSTRUCTIONS: Crown Battery Manufacturing Company specifies the following standard battery charge profile for the CR-430 deep cycle battery when used in an electric vehicle service: Phase 1: Constant Current (I1) I1 = highest amperage available < 100 amps Phase 1: Constant Current (I1) I1 = minimum amperage available > 40 amps Normal transition to Phase 2 at 2.37 Volts Per Cell. Safety transition to END OF CHARGE of dv / dt <0V / 1 hr, dt = 1 hr. (NEGATIVE SLOPE). Timeout for Phase 1 = 10 hours. Phase 2: Constant Voltage (U2) U2 = 2.37 VPC Normal Transition to Phase 3 at I2 = 15.0 amps or approximate. Safety transition to END OF CHARGE of l di/dt l < 0.4 amp / 1 hr, dt = 1 hr. Phase 3: Constant Current (I3) I3 = 15.0 amps or approximate Normal transition to END OF CHARGE at 115-118% of AH returned. PLEASE CONTACT CROWN BATTERY MANUFACTURING COMPANY TO ADVISE THE SPECIFIC CHARGE TERMINATION METHOD USED. Timeout for charging phases 1-3 at 16 hours. Temperature compensation coefficient = +/- 3 mv / C. Recommended Equalization Charge: Every seven (7) days. 4 additional hours at normal finish rate of 15.0 amps for 4 hours. Safety transition to END OF CHARGE at maximum voltage of 2.7 VPC. 1445 Majestic Drive P.O. Box 990 Fremont, OH USA 419.334.7181 Fax 419.334.7124 www.crownbattery.com Made in U.S.A.

CR-430 Commercial Deep Cycle Battery APPLICATION RECOMMENDATIONS Specific Gravity Operating Temperature Range Self Discharge Terminal Torque Specifications Fully charged battery specific gravity (100% state-of-charge) is 1.275 Fully discharged battery specific gravity (100% depth-of-discharge) is 1.125-40 F to 120 F (-40 C to 49 C). Flooded lead acid battery capacities are temperature sensitive: refer to the temperature / capacity projection chart below to identify available capacity at the application operating temperature. Application Note: Maintain a state of charge greater than 60 percent when operating flooded lead acid batteries at temperatures below 32 F (0 C). Fully charged batteries that are stored at a temperature of 80 F (27 C) will self-discharge at a rate of 3.5% per week. SAE / Automotive Terminal Style: 50 to 70 in-lbs / 6 to 8 Nm Stainless Threaded Terminal (Types C, S, Z): 100 to 120 in-lbs / 11 to 14 Nm Application Note: Lead acid batteries contain corrosive battery electrolyte and generate highly flammable hydrogen gas. When working near batteries wear protective clothing, gloves, and safety glasses when handling batteries and electrolyte and always work in a well-ventilated area. Do not over-torque terminals. Over-torque can result in terminal damage, breakage, terminal meltdown or fire. Crown Battery s flooded lead acid deep cycle batteries require periodic preventative maintenance and effective charging service to ensure dependable service life. Customers can find Crown Battery s recommended best practices for deep cycle battery care, maintenance and application at www.crownbattery.com/en/wp-content/uploads/2012/10/safetyfirst-deepcycle2.pdf or by contacting Crown Battery to request this information. AVAILABLE CAPACITY AT APPLICATION OPERATING TEMPERATURE 60 140 50 120 40 100 Temperature (C) 30 20 10 0-10 -20 80 60 40 20 0 Temperature (F) 12.38 (314) 16.13 (410) 15.29 (388) -30-20 -40-40 0% 20% 40% 60% 80% 100% 120% Percent of Available Capacity 11.51 (292) 7.19 (183) TYPICAL BATTERY CYCLE LIFE / DEPTH OF DISCHARGE Battery Model 100% DOD Cycles End-Cycle Voltage 50% DOD Cycles End-Cycle Voltage 40% DOD Cycles End-Cycle Voltage 20% DOD Cycles End-Cycle Voltage CR-430 500 1.75 VPC 1200 1.94 VPC 1500 1.97 VPC 3000 2.05 VPC The battery life references presented above are estimations based upon stationary life cycle testing conducted at Crown Battery Manufacturing s Testing Center in Fremont, Ohio USA. The data references are nominal and should not be construed as maximum or minimum values for specifications or for final design. Data for this product type may vary from that shown herein, and Crown Battery makes no warranties expressed or implied based upon the data shown above. Effect of Battery Temperature on Battery Life Lead acid batteries are electrochemical storage devices that store and release chemical energy upon demand in the form of electricity. By virtue of their design lead acid batteries are highly reactive to temperature with the rate of chemical reactions that occur within the battery being affected by the operating temperature where the battery is used. Higher operating temperatures will result in faster chemical reactions within the battery delivering improved discharge performance; conversely, cooler operating temperatures will result in slower internal chemistry. However, higher operating temperatures also result in shortened battery life as the increased rate of chemical reactions will accelerate the rate of deterioration of internal components. Typical battery life is based upon a baseline operating temperature of 80 F / 27 C. Temperature increases of 15 F / 10 C over the baseline will cause the battery s rate of internal chemical reactions to double something that will reduce battery life due to the accelerated deterioration of internal components. Please contact Crown Battery to discuss any minimal requirements for battery life when operating batteries in temperatures greater than 80 F / 27 C. 1445 Majestic Drive P.O. Box 990 Fremont, OH 43420-0990 USA +1.419.334.7181 Fax +1.419.334.7124 www.crownbattery.com sales@crownbattery.com The data shown are nominal and should not be construed as maximum or minimum values for specification or final design. Data for this product type may vary from that shown herein. 2013 Crown Battery Manufacturing Company Visit our website at www.crownbattery.com Form No. TDS-D06430-0213

ANEXO 4: Ficha técnica de inversor

The RD Series Inverter/Charger For Renewable Energy Applications The RD Series Inverter/Charger is powerful, easy-to-use, and cost effective. MODEL NUMBERS: RD2212 RD1824 RD2824 RD3924 AVAILABLE FOR: Renewable Energy Systems Off-grid Power Back-up Power AVAILABLE ACCESSORIES: AGS Battery Monitor Kit DC Load Disconnect Fuse Blocks Remote Remote Switch Adapter Series Stacking Interface Reliable Off-Grid Power from Magnum Energy The RD Series Inverter/Charger from Magnum Energy is a new generation inverter designed specifically for renewable energy use. The RD Series is powerful, easy-to-use, and best of all, cost effective. Power Factor Corrected (PFC) Charger: Our PFC charger is built into all of our inverter chargers. It uses less energy from a generator than a standard charger using 25-30% less AC current than standard chargers. Safe and reliable: The RD Series is ETL Listed to the stringent requirements of UL 1741, ensuring that the inverter is safe and reliable. Easy-to-install: Install the RD Series in four easy steps: simply connect the inverter s output to your distribution circuits or electrical panel, connect your power cable (AC) to the inverter s easy-toreach terminal block, connect the batteries, and switch on the power. Features You asked and Magnum listened. The RD Series Inverter/Charger is loaded with features: Multiple ports: The RD Series provides multiple ports, including an RS485 communication port for network expansion, and a remote port. Accessible design: The extra large AC access cover with terminal screw block and 360 DC connection terminals with covers make this inverter more accessible when it needs to be. Convenient switches: The RD Series comes with an on/off inverter-mounted switch with an easy-to-read LED indicator. Expanded transfer relay: 60 Amp transfer service is available on all models. Buy with ease: The RD Series is backed by a two-year (24-month) limited warranty. Accessories and Options* Remote control: For convenient finger-tip operation, including the new one-knob programming. AGS module: Automatically starts and stops your generator based on temperature or battery voltage. Choices: The RD Series comes in four power models and 12 and 24 volt models, allowing you to choose the model that is right for you. Versatile mounting: Mount the RD Series on a shelf or wall. Lightweight: The lightweight aluminum base and cover also provides noise reduction and corrosion resistance. The Powerful Difference * For more detailed information and specifications on these accessories, please see the accessories data sheet.

The RD Series Inverter/Charger Specifications RD2212 RD1824 RD2824 RD3924 Inverter Specifications Input battery voltage range 9-16 VDC 18-32 VDC 18-32 VDC 18-32 VDC Nominal AC output voltage 120 VAC 120 VAC 120 VAC 120 VAC Output frequency and accuracy 60 Hz ± 0.005% 60 Hz ± 0.005% 60 Hz ± 0.005% 60 Hz ± 0.005% 1 msec surge current (amps AC) 60 70 100 150 100 msec surge current (amps AC) 37 40 60 90 5 sec surge power (real watts) 3700 4000 6000 9000 30 sec surge power (real watts) 3450 3300 4800 6400 5 min surge power (real watts) 3100 2850 3950 5800 30 min surge power (real watts) 2400 2400 3500 4750 Continuous power output at 25 C 2200 VA 1800 VA 2800 VA 3900 VA Rated input battery current 191.0 ADC 88 ADC 133 ADC 188 ADC Inverter efficiency (peak) 95% 95% 94% 93% Transfer time 16 msecs 16 msecs 16 msecs 16 msecs Search Mode.2 ADC.3 ADC.3 ADC.3 ADC No Load (120 VAC output) 0.87 ADC.5 ADC.6 ADC.6 ADC Waveform Modified Sine Wave Modified Sine Wave Modified Sine Wave Modified Sine Wave Charger Specifications Continuous output at 25 C 110 ADC 50 ADC 80 ADC 105 ADC Charger efficiency 85% 85% 85% 92% Power factor > 0.95 > 0.95 > 0.95 > 0.95 Input current at rated output (AC amps) 15 15 21 29 General Features and Capabilities Transfer relay capability 2 legs at 30 A for 120 V/30 A or 240 V/60 A service Five stage charging capability Bulk, Absorb, Float, Equalize, and Battery Saver Battery temperature compensation With available temp sensor (battery temp 0 50 C) Remote inverter on/off switch With available pigtail to connect to dry contact Internal cooling 0 to 120 cfm variable speed drive using dual 92mm brushless DC fans Overcurrent protection Yes, with two overlapping circuits Overtemperature protection Yes on transformer, MOSFETS, and battery Conformal coating on PCB s for corrosion protection Yes Powder coated chassis & top for corrosion protection Yes Stainless steel fasteners for corrosion protection Yes Listings ETL listed to UL1741 Warranty Two years Environmental Specifications Operating temperature -20 C to +60 C (-4 F to 140 F) Nonoperating temperature -40 C to +70 C (-40 F to 158 F) Operating humidity 0 to 95% RH non condensing Physical Specifications Dimensions (h x w x d) 13.75 x 12.65 x 8.0 (34.9 cm x 32.1 cm x 20.3 cm) Mounting Shelf or wall (vents up) Weight 38 lb (17 kg) 38 lb (17 kg) 42 lb (19 kg) 45 lb (20 kg) Max operating altitude 15,000 (4570 m) Magnum Energy, Inc. 1111 80th Street SW, Suite 250 Everett, Washington 98203 USA The Powerful Difference Phone: 425-353-8833 Fax: 425-353-8390 Web: www.magnumenergy.com Testing for specifications at 25 C Specifications subject to change without notice. March 2007, Rev B Part #64-0300 Authorized Magnum Dealer