GAA. GasApps Australia P/L. MultiTimer MKII. Manual. Prepared By GasApps Australia P/L 2/11/05

Similar documents
GAA. Capillary Timer Box # Manual. GasApps Australia P/L. Prepared By GasApps Australia P/L 5/8/05.

MiG2 TIME SWITCHES. 1, 2 & 4 Channel, 365 Day, Energy Saving Time Switches

INSTALLATION INSTRUCTIONS. Timer Features

Instruction Manual MINI IRRIGATION CONTROLLER.

IRRIGATION CONTROLLER

Richdel 300 SERIES MECHANICAL CONTROLLERS INSTALLATION AND OPERATING GUIDE FOR ALL MODELS

Light switch timer 3 step Installation overview 3 minute quick programming guide. A police accredited product.

DEMA 257C / 257CV PRO BATTERY DRAIN CHIEF INSTALLATION & OPERATING INSTRUCTIONS

OWNERS MANUAL POWER PACK 44AH. Part No. COMPBI012. Australia s original Outdoor brand

AquaMatic Series. A100 and A200 Stager Controls

12V 160A/24V 185A MANUAL WORKSHOP BATTERY CHARGER

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

DEMA SQUIRT DRAIN UNIT

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Model LA 4400 Time Delay OFF Controller

Peri Dosage Pumps AQUARIUS. Peristaltic Dosage Pumps for the dosage of liquid Water Treatment Chemicals - rated to 250 kpa. For Reliable Dosage of

Gate & Door Controller with LCD and Intelligent Technology

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Touch Sensor 2 plus Installation Instructions

2-Way Dimmer (1 Gang)

PCS HIGH-LOW TIMER CONTROLLER USER GUIDE PCS HIGH-LOW TIMER CONTROLLER. Contents. Calibrating the Transducer... 6

Uninterruptible Power System

Portable Pack USER MANUAL

PULSE-8: MASTER PULSATION CONTROL

REVISION HISTORY REVISION HISTORY

Installation and Maintenancee Manual

MC2500. Installation and Operation Manual

MODEL No s: PP3, PP3K

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

INSTALLER MANUAL USER MANUAL. Contents

DEMA S.U.D.S Jr. SINGLE PRODUCT LAUNDRY 581K(I)(S)(V)

SPECTRA ENGINEERING PTY LTD. MXPS15 Series Technical Manual

3. Place of work. This should be where you are usually based, and where we can send correspondence for your attention.

DIESEL Engine Fire Pump Controllers Features

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

i n s t r u c t i o n m a n u a l

Instruction Manual LA-SDO1 Sectional garage door opener

Validator and Control Board Update Instructions for BC1

230VAC Power Inverter 400W Owner s Manual

Trapper Drain Maintenance/Odor Control Chemical Dispensing

12/24V 30A AUTOMATIC/MANUAL WORKSHOP BATTERY CHARGER

RECHARGEABLE PORTABLE EVAPORATIVE COOLER

DEMA Nitro for Europe Ware Wash Chemical Dispensing

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

World Leaders in Diesel Fuel Injection Test Equipment. IFT-c. Injector Function Tester Controller. Operating and Servicing Manual

BIOACTIVE SOLUTIONS AC DRAIN STATION

KELCO F60 DIGITAL PUMP CONTROLLER

CONTACT YOUR AUTHORISED STOCKIST

7C MERGER M40/50RF SYSTEM INSTALLERS GUIDE

INSTALLATION & OPERATING MANUAL LIGHT SABER LED SHAFT LIGHTING SYSTEM EN81-20 INNOVATION NOT IMITATION!

PASSENGER DEMAND WEST CHECKPOINT November 2018 Scheduled Departing Passengers & Seats

Uninterruptible Power System

ASI Model 8374 Automatic Roll Towel Mechanism Owner s Manual

Installation and Operating Instructions. Solar System Controller ISC3030

Reverse Polarity MANUAL. Surechlor S3500


360 o Excavator. pre use check sheet page 1/5. How to use this check sheet:

DEMA Dispensing. Overview. Warnings. I-1205 Rev. B a digital ware. The DEMA. Nitro Plus is. tee.

Sectional And Tilting Door Opener

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

N-BUGGY OPERATION MANUAL. Hayes Spraying ABN Troy Drive PO Box 515 GOONDIWINDI QLD 4390

SRC. An Outdoor Reset Control for Sub-Atmosphere Steam Systems OUTDOOR TEMPERATURE

28W WORK LAMP Model: CTL28 Part No:

SC-Max 48V series. User Manual. Solar Charge Controller 30A

OWNER S MANUAL Please read this manual before operating your power supply

FourStar Golf Cruiser

Mightylite Solar LED PIR Floodlight with Solar Panel

Sapling Converter Box

POWER LIFT OWNERS MANUAL CONTENTS

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

This manual covers the following model:

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Instruction Sheet. CFRD Series. High CFM Split Rear Doors

ATLAS Wheel Balancer Electrical Flow Chart

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Installation and Operations Manual

Rev. U8e PL80e. Advanced PWM Solar Charge Controller. User Guide. Read this before installing. Solar Charge Controller

Ezyfit AC Controller INSTRUCTION BOOK 2 & 4 STATION UNITS

Operation of Fork Lift Trucks

THUNDERBIRD Solar Electric Fence Energisers. S20 / S20B / S40 / S40B / S79 / S150

Articulated Dumper. pre use check sheet page 1/5. How to use this check sheet:

BATTERY METER SMART BATTERY GUAGE

SBC V In-Car Charger Dual Input (Solar MPPT & DC)

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

Web Volume Control Model WV220

Uninterruptible Power System

Owner s Manual. For SOLAR BOOM GATE. Model: CA-5000 SOLAR

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

FREQUENCY INVERTER INSTALLATION & USER GUIDE

MULTI FUNCTION POWER PAK PLUS

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

INTELLI-POWER BATTERY CHARGER 12 VOLT, 7 STAGE SWITCHMODE. P/No.s IC700, IC700W, IC1000, IC1500

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

Model LA 4100 Time Delay OFF Controller

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS

Loctite Spray Valve Controller Part Number EQUIPMENT Operation Manual

2-Way Dimmer (1 Gang)

digital tap timer co1705 InstructIon Manual

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

Transcription:

GAA GasApps Australia P/L MultiTimer MKII Manual Prepared By GasApps Australia P/L 2/11/05 1

Contents General Description General Specifications Installation Instructions Drawings & Photos Weekly Time Clock Manual Warranty 2

General Description The MultiTimer MKII is designed to control a single 240VAC solenoid valve for the dispensing of BOC Gases Envirosols products. These products include Pestigas, Deodourgas, Ripegas and Bactigas. The MKIII Spacecontroller is the only BOC Ltd approved dispensing equipment for use with Insectigas. Although limited approval is given to the use of solenoid valves for the automatic dispensing of Envirosols other than Insectigas, it is essential that only approved solenoid valves (#730016) and timers are used. The MultiTime MKII incorporates an electronic digital seven-day time clock in conjunction with an ON/Off Cycle timer. The combination of these two timers allow the operator to set up an external solenoid valve to pulse ON and OFF (adjustable ON and OFF from 01.s to 100h) during any period of time which is controlled by the seven-day time clock. The seven-day single channel time clock is capable of storing twenty different programme times, i.e. 10 ON switches and 10 OFF switches. These programmes can be set to run on any individual day or any combinations of days within each week. The time clock includes the following front panel buttons Time, Program, Manual, Day, Hour, Min, Clear, +1h, and Reset. The LCD display shows 12 or 24hr Time, Day/Number of the week, Switch status ie. ON or OFF, Automatic, Manual and FIX Modes Always clear existing programs before entering any new program. All previous programmes should be deleted to avoid any confusion between old and new programs. To clear all existing switching commands, press tee Prog key as often as necessary until FRxx appears. Then press the Clear key once. CL is displayed. Now press and hold down the Clear key. All memory locations are now deleted. The display should show Fr20 indicating all 20 memory locations are available. Always turn OFF all gas cylinders before attempting to set or adjust the weekly time clock. It s important to insure that the program is running correctly before gas is turned ON. The White Power Lamp indicates when the unit is plugged into mains 240VAC 50Hz power. A 6AMP circuit breaker is also included and can be used as an ON/OFF switch The Asymmetrical Cycle Timer controls the length of time in which the solenoid valve is ON and OFF for. Both the ON and OFF times can be adjusted from 0.1 second to 100 hours. The top two wheels marked RANGE 1 and TIME 1 are used to adjust the length of time in which the solenoid valve will switch ON (energise) for. The bottom two wheels marked RANGE 2 and TIME 2 are used to adjust the length of time in which the solenoid valve will switch OFF (deenergise) for. Below are a few examples of how to adjust the Cycle Timer WARNING! It s important not to cycle the solenoid too frequently as both the cycle timer and valve have a limited life cycle. It is recommended to program the ON time for 1 second or more and the OFF time for 5 seconds of more. Solenoid Valve Connection This unit has been fitted with two special solenoid outlet sockets and is supplied with two loose plug tops to match. The socket outlet and plug top are rated for 240VAC 50Hz 10A and have round earth pins so as to make it impossible for people to plug in standard appliances. 3

General Specifications Dimensions : 130mm wide x 180mm high x 110mm deep Weight : 1kg Power Requirements : 240VAC 50Hz x 10AMP Protection : IP55 Cycle Timer : 240VAC, On/OFF Cycling, Electronic (range 0.1s 100h) Seven-Day Timer : 240VAC, Electronic, Digital Display, 3 years Battery Backup Circuit Breaker : 6 AMP 240VAC single Phase LED Power Lamp : White, 240VAC [see Fig 3] Inlet Power : 240VAC Plug Top c/w 1.8m Power Lead Outlet Power : 240VAC 50Hz Socket Outlet, 3 Pin - Round Earth [see Fig 4] Temperature Range : -5ºC to +40ºC Mounting : Wall Mount Figure 1 4

Installation Instructions Mounting the MultiTimer MKII The MultiTimer MKII is a weatherproof enclosure, however it is recommended that the unit be installed undercover away from direct sunlight and in a secure area. This unit must be installed by a qualified electrician, as there are 240VAC terminals exposed inside. A 240VAC 50Hz 10A power point will need to be available to plug into. The unit is supplied with a rear PVC mounting plate with four mounting holes 145mm x 145mm x 7.0mm WARNING Always disconnect the mains power supply before removing the front cover. The front cover will need to be removed by undoing the four Phillips head screws. There are four potential mounting holes available in the rear of the enclosure. The mounting hole dimensions are as follows 125mm x 102mm with a hole size of 4mm. Once the box has been secured to the wall the front cover should then be carefully replaced using the four Phillips head screws. Take care not to over tighten the four screws. The external solenoid valve (#730016) will need to be wired up to the special plug top provided [see Fig 1, and Fig 4]. Figure 2 5

6

Figure 3 Figure 4 7

Figure 5 Setting Examples For Cycle Timer Required Wheel Settings Solenoid ON Time Solenoid OFF Time Required Time RANGE 1 Wheel TIME 1 Wheel RANGE 2 Wheel TIME 2 Wheel 8 seconds ON 18 minutes OFF 1s 8 0.1h 3 2 seconds ON 8 minutes OFF 1s 2 60s 8 12 seconds ON 2 minutes OFF 6s 2 60s 2 0.5 seconds ON 30 seconds OFF 0.1s 5 6s 5 1 minute ON 2 hours OFF 60s 1 1h 2 8

Grasslin Time Clock Quick-Setup Instruction Grasslin Time Clock Quick Setup Program Command Display Reset The Time Clock Depress "res" once 00:00 Repeatly Depress "+hr" until "No" appears No Depress " " once 00:00 CH1 Clear Existing Program Memory Depress "Prog" until "FR00" appears FR00 Depress "Clear" twice CL Flashing - then - FR20 Depress " " once 00:00 Set Time & Day Depress " " once 00:00 Depress "Day" to select the current day of the week ie 1=Mon, 2=Tue, 3=Wed, 4=Thur 5=Fri, 6=Sat, 7=Sun Depress "h" to select the current hour of the day 15:00 Depress "m" to select the current minute of the hour 15:45 When fiinished Depress " " once to enter the time 15:45 Setup 1st Program (eg. Turn ON Output) Depress "Prog" - - : - - Depress "Day" to select the current day of the week ie 1=Mon, 2=Tue, 3=Wed, 4=Thur 5=Fri, 6=Sat, 7=Sun Depress "h" to select the current hour of the day 17:00 Depress "m" to select the current minute of the hour 17:55 Depress the "hand" button until the " " appears (=Output ON) Depress " " once CH1 17:55 CH1 Setup 2nd Program (eg. Turn OFF Output) Depress "Prog" - - : - - Depress "Day" to select the current day of the week ie 1=Mon, 2=Tue, 3=Wed, 4=Thur 5=Fri, 6=Sat, 7=Sun Depress "h" to select the current hour of the day 18:00 Depress "m" to select the current minute of the hour 18:00 Depress the "hand" button until the " " appears (=Output OFF) Depress " " once CH1 17:55 CH1 9

WARRANTY GasApps Australia Pty Ltd warrants the design of the MultiTimer MKII System for a period of 12 months from the date of invoice. GasApps will not accept any liability whatsoever for any alterations or modifications, made to any part of the equipment supplied, without written and signed authorisation from GasApps Australia Pty Ltd. This Manual is supplied for the guidance of operators to enable them to understand and operate the equipment in accordance with its design specifications. The long-term operation of the components and the unit as a whole depends highly on maintenance procedures and gas quality. This is solely dependent on the operator or buyer. GasApps Australia Pty Ltd will not accept any liability for equipment failure due to poor quality gas and lack of maintenance. Installation of electrical and gas connections must be made in accordance with BOC and GasApps specifications. GasApps Australia Pty Ltd accepts no liability whatsoever for the consequences of any actions by persons other than GAA employees, which are not in accordance with the procedures set out in this Manual 10