SHORTER. LIGHTER. MORE VERSATILE. 1 VALVE 10 TRIM CONFIGURATIONS 4" AND 6" MODEL RCW WATER CONTROL VALVE FOR DRY, PREACTION AND DELUGE APPLICATIONS

Similar documents
MODEL RCW NON-INTERLOCK PREACTION SYSTEM

MODEL RCW DELUGE SYSTEM ELECTRIC, WET PILOT, AND DRY PILOT ACTUATION

MODEL UM UNIVERSAL MANIFOLD ASSEMBLY (With or Without Control Valve) 1¼", 1½", 2", 2½", 76.1mm, 3", 4", 6",165.1mm, 8"

TECHNICAL DATA. Q= C v P S

TECHNICAL DATA 1-1/2 (dn40)

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

Model DDX Deluge Valves 4" (100 mm), 6" (150 mm) and 165 mm Sizes

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

TECHNICAL DATA. Trimpac 249a. September 16, 2013

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

Features 1. Differential Latch-type, lightweight, dependable

Model DDX Deluge Valve 8 (200mm) Features

1-1/2 Inch (DN40) 9 lb (4,1 kg) Groove Groove 1 8 lb (3,6 kg) Flange Groove 1 N/A N/A. Flange Flange N/A N/A

TECHNICAL DATA TRIMPAC MODEL B-4, B-4B & B-4S SINGLE INTERLOCK PREACTION SYSTEM WITH PNEUMATIC RELEASE

Instructions for Installation, Operation, Care and Maintenance

Easy Riser swing check valve Models E-1 & F-1

DV-5 Deluge Valve Aluminium Bronze Diaphragm Style General Description

ALARM CHECK VALVE 3", 4" & 6" MODEL H-1 FLANGE/FLANGE 3" & 4" MODEL H-2 GROOVE/GROOVE 3", 4" & 6" MODEL H-3 FLANGE/GROOVE

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

Instructions for Installation, Operation, Care and Maintenance

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL H-2 HALAR COATED 2 (DN50) - 6 (DN150)

MODEL UMC UNIVERSAL MANIFOLD CHECK ASSEMBLY

TECHNICAL DATA. Trimpac 244a. April 15, 2011

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

Instructions for Installation, Operation Care and Maintenance

Series 758 FireLock Actuated System Valve

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

DELUGE VALVE DATA SHEET

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

Instructions for Installation, Operation, Care and Maintenance

TECHNICAL DATA. Q= C v P S. Table 1 - Valve Part Numbers and Specifications

TECHNICAL DATA OBSOLETE

Series 769 FireLock NXT Deluge Valve

DV-5a Automatic Water Control Valve Double Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

TECHNICAL DATA P S. Q= Cv MODEL E-2 DELUGE VALVE HALAR COATED ANGLE STYLE

TECHNICAL DATA 2-1/2-8 (dn65 - dn200)

AGCX Bulletin 519 C/Alfoz de Bricia nº4 P.l. Villalonquéjar Burgos (Spain) Tlfno: PAG 1 de 50

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL J-2 HALAR COATED 1-1/2 & 2 (DN40 & DN50) 1. DESCRIPTION

Q= C v P S. Flow control valve Model j-2 Halar coated

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

TECHNICAL DATA CAUTION

TotalPac 3 Deluge system Pneumatic release

4077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE FAX

Worldwide Contacts.

Instructions for Installation, Operation, Care, and Maintenance

TECHNICAL DATA CONCENTRATE CONTROL VALVE APPLICATIONS, PRIMING CONNECTIONS, AND TRIMS 1. GENERAL DESCRIPTION 2. LISTINGS AND APPROVALS.

TotalPac 3 Firecyle III Wet pipe Remote controlled system

TotalPac 3 Non interlock Preaction system Pneumatic release

INSTALLATION & MAINTENANCE GUIDE

Series 756 FireLock Dry System Check Valve

Instructions for Installation, Operation, Care and Maintenance

TotalPac 3 Deluge, Electric release Remote controlled system

TECHNICAL DATA OBSOLETE. Inlet Type Outlet Type in mm. Thread Thread in. ANSI B Flanged Flanged in.

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

Series 751 FireLock European Alarm Check Valve Stations

GW MKIII DELUGE VALVE - ALUBRONZE EXTERNAL RESET, PNEUMATIC

FireLock NXT Actuated Valve with Preaction Trim. System No. Submitted By Spec Sect Para Location Date Approved Date

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Remote controlled system

DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Wet Pilot Actuation General Description

Section R Foam Systems

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

Section R Foam Systems

Instructions for Installation, Operation, Care and Maintenance

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

TotalPac 3 Double interlock Preaction, Electric/Pneumatic release Remote controlled system

Grooved Piping System for Fire Protection Services

Wet pipe low flow foam/water manifold system

TotalPac 3 Non interlock Preaction, Electric release Remote controlled system

Preaction System with DV-5 Deluge Valve Double Interlock Electric/Electric Actuation. General Description. Page 1 of 14 DECEMBER 2014 TFP1465

GW MK3 DELUGE VALVE HYDRAULIC & PNEUMATIC SPARES 100mm (4 ) 150mm (6 ) 200mm (8 )

TECHNICAL DATA. Table Standard Materials

model E Spray nozzles vk810 - vk817

DV-5A Automatic Water Control Valve Remote-Resetting Deluge Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

TotalPac 3 Double interlock Firecyle III Preaction Remote controlled system

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

Sl. No. Description Pages

Technical Data. UL Listing is based on the following criteria:

HD Series. Pilot-Operated Regulating Valves. HD Series features & benefits

TECHNICAL DATA VK810 (65 ) VK811 (80 ) VK812 (95 ) VK813 (110 )

Grooved Piping System for Fire Protection Services

Deluge Valves. Model 68 DE\ HM-MR. Hydraulically Actuated Manual-Reset Deluge Valve. Dorot Fire Protection Division

TECHNICAL VALVES PRINCIPLE OF OPERATION DOROT PLASTIC VALVES. 3-Way Control System. 2-Way Control System T48

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose

Technical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE

CJ=TN=- FRONT DELUGE VALVE, EXTERNAL RESETTING. MODEL F470 MULTIMATIW - 4 and 6 INCH (100 and 150 mm) a P il

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 227b - d

Colt Series C400, C500

CUSTOM COMBINATION AIR VALVE

Deluge Valves. Model 68 DE\ HRV-MR. Hydraulically Actuated, Anti-Columning, Manual-Reset Deluge Valve. Dorot Fire Protection Division

AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT

Temperature Sensor Series

FireFlex DUAL Single Interlock, Remote controlled system

Instructions for Installation, Operation, Care and Maintenance 2 PSI (0,14 bar) Pneumatic Supervising Pressure with Electric Actuation

Adjustable Differential Relay A1

627 Series Pressure Reducing Regulators

4 - Way Control 4 - Way Control 4 - Way Control with lock

Deluge Pressure Reducing Valves. Model 68 DE\ RCL\ PR. Electrically Actuated, Manual-Reset, Pressure Reducing, Deluge Valve

Transcription:

SHORTER. LIGHTER. MORE VERSATILE. " AND 6" MODEL RCW WATER CONTROL VALVE FOR DRY, PREACTION AND DELUGE APPLICATIONS Globe is proud to introduce the new Model RCW Water Control Valve for dry pipe, preaction and deluge applications. It is uniquely engineered to minimize many of the field issues historically seen with hydraulically operated differential-style valves. All system types use one common valve body and its lighter weight and smaller size make it easier and faster to install. 1 VALVE 10 TRIM CONFIGURATIONS One valve comes in 10 different culus-listed/fm-approved trim configurations, lowering your inventory costs. The " and 6" RCW is lighter than any other manufacturer s valve currently on the market. In each trim configuration, it is lighter than other makers versions. The RCW has the shortest end-to-end dimensions of any water control valve on the market. Double-seat design means no additional check valve is needed for preaction systems. Single-bolt clapper seal replacement, easy access to hinge pin and minimal bolts for handhole cover removal make the RCW easier to maintain and inspect. Diaphragm-to-clapper latching mechanism uses our unique, patent-pending roller arm design, offering lower friction loss and ensuring dependable performance unimpeded by corrosion or debris.

ONE VALVE. MANY APPLICATIONS. The Globe RCW Water Control Valve and each of its trim options have been engineered to meet the most important needs of both the installer and end user. INSTALLATION As an installer, you need only stock one valve for a variety of different system configurations. The RCW s compact design makes it lighter and shorter in size than any other comparable valve on the market. This makes installation easier and, often, faster. The completed assembly takes up a smaller footprint in the building. The RCW s double-seat design means no additional check valve is required. And you are backed by Globe s renowned customer service and technical support every step of the way. OPERATION The RCW is designed to perform. Its diaphragm-to-clapper mechanism is a unique new design featuring a low-friction roller arm. It uses a positive action spring force to assist movement of the diaphragm away from the clapper when diaphragm chamber water pressure is evacuated. Coupled with the minimal movement of the roller assembly, this results in faster operation on pressure drop and more dependable operation. The robust design allows for free movement of the lever arm assembly, even if debris or corrosion are present. The RCW is a differential latching valve with a convenient external reset knob. Internal inspections and maintenance are easier, thanks to unique features such as one-bolt clapper seal replacement and easy handhole cover removal. And color-coded handles make it easy to identify, at a glance, if trim valves are in their proper positions.

Easy access hinge pin External reset Patent-pending low-resistance roller arm The Globe RCW Valve is available pre-trimmed or loose-trimmed in the following system configurations: Dry System Available with Standard or Low Pressure Actuator Optional Accelerator Deluge System Electric Actuation Dry Pilot Actuation Wet Pilot Actuation Single Interlock Preaction System Electric Actuation Dry Pilot Actuation Wet Pilot Actuation Double Interlock Preaction System Electric/Electric Actuation Electric/Pneumatic Actuation - Available with Standard or Low Pressure Actuator Non Interlock Preaction System

DRY SYSTEMS Dry pipe sprinkler systems are typically used in unheated areas and other locations exposed to freezing temperatures, where water-filled pipe cannot be used. When set for service, a dry pipe sprinkler system incorporating automatic sprinklers (closed) is pressurized with air or nitrogen. In response to heat from a fire, an operated automatic sprinkler causes a loss of air pressure and permits the dry pipe valve to open. This allows a flow of water into the sprinkler system piping. RCW IN HONOR OF Robert C. Worthington, PE Robert C. Worthington was a pioneer in fire sprinkler system engineering, with a long and successful career before he purchased Globe in 1988. Mr. Worthington made a commitment to producing a high-quality product in the U.S. This valve is named in honor of his spirit of innovation and his lifelong dedication to saving lives and protecting property from fire. Dry systems are used in any unheated portion of a building: Warehouses Loading Docks Unheated Attic Spaces Shipping Platforms Cold Storage Parking Garages Outdoor Piers Unheated Attic Spaces Dry Pipe Systems

DELUGE SYSTEMS Deluge systems are used for special hazards where there are easily ignitable and fast-burning substances which promote rapid fire development. They are typically used for fire extinguishment, fire control or exposure protection in applications such as: With materials having high rates of heat release Conveyors Water Curtains Fuel Storage Tanks Electrical Transformers Aircraft Hangars Chemical Plants Electric Actuation Dry Pilot Actuation Wet Pilot Actuation SINGLE INTERLOCK PREACTION SYSTEMS Single interlock preaction systems are used in any portion of a building where it is undesirable to have water-filled pipes over the hazard being protected. Such systems typically employ air or nitrogen under pressure, with a supplemental detection system installed in the same area as the sprinkler system. These valves are activated by a single event, an electrical detector activation, an activation of a pilot sprinkler connected to pilot lines under air pressure (dry pilot), or an activation of a pilot sprinkler connected to pilot lines under water pressure (wet pilot). They are commonly used in: Computer Rooms Archives Libraries Document Storage Centers Single Interlock Electric Actuation Single Interlock Dry Pilot Actuation Single Interlock Wet Pilot Actuation

DOUBLE INTERLOCK PREACTION SYSTEMS Double interlock preaction systems are used in any portion of a building where flooding or inadvertent discharge of water would be especially damaging. These valves are activated by two separate events: an electric activation plus a sprinkler activation. In the case of Electric/Pneumatic Actuation, a detector activation sends an electrical signal to the release panel, opening a solenoid valve. This event would typically be followed by a sprinkler activation, releasing air pressure in the sprinkler piping, allowing the pneumatic actuator to open, and tripping the RCW valve. In the case of Electric/Electric Actuation, a detector activation will send the first electrical signal to the release panel. The activation of a sprinkler will allow air pressure in the sprinkler piping to escape, activating a low air pressure switch. This sends a second signal to the release panel, which opens the solenoid valve, tripping the RCW valve. They are commonly used in applications such as: Freezers Valuable Archives Critical Document Storage Double Interlock Electric/ Pneumatic Actuation Double Interlock Electric/ Electric Actuation AND DONE! The simplicity and versatility of the Globe RCW make it an excellent choice for every application. With it, it s truly one and done. To learn more about the Globe RCW Water Control Valve, contact your local Globe territory manager, contact our customer service team at (989) 86-583 or visit globesprinkler.com/rcw.

TECHNICAL SPECIFICATIONS Approvals: culus and FM Maximum system working pressure: 300 psi (20.6 bar) Materials of construction: See Table below Take out dimensions (end to end): " (DN100) Valve 13.13" (333,5mm) " (DN100) Valve w/ Model GLR300G 17.66" (8,5mm) 6" (DN150) Valve 1.7" (367,5mm) 6" (DN150) Valve w/ Model GLR300G 19.69" (500mm) 3 2 1 Model RCW Cross-Section ITEM DESCRIPTION MATERIAL 1 RCW-2 Body (groove/groove) Ductile Iron 2 Seat Ring Bronze 3 Clapper Bronze 25 29 9 26 20 3 22 33 Retaining Ring 31 Stainless 5 Retaining Bolt Steel 6 Clapper Facing Disc EPDM B 8 7 Latch Arm Bronze 13 1 10 19 23 12 7 11 6 30 28 5 3 15 1 2 8 Clapper Latch Bronze 9 Reset Plunger Bronze 16 10 Push Rod Bronze 11 Roller Stainless 12 Diaphragm Retainer Ductile Iron 13 Diaphragm Rubber 21 2 2 1 17 18 1 Diaphragm Cover Ductile Iron 15 Clapper Hinge Pin Stainless 16 Clapper Hinge Pin Bushing Bronze 21 17 32 Hand 27Hole Cover Gasket Rubber 18 Hand Hole Cover Ductile Iron 19 Diaphragm Spring Stainless 20 Reset Bushing Bronze A 31 21 Cover Bolt Steel B 22 Clapper Latch Hinge Pin Stainless 23 Roller Arm Hinge Pin Stainless 2 Roller Arm Hinge Pin Clip Stainless 15 1 2 3 16 25 Reset Plunger Knob Bronze 2 26 Plunger O-Ring Rubber 27 Name Plate Aluminum 28 Return Spring Stainless 1 29 Reset Plunger Spring Stainless 30 Roller Bushing Bronze 31 1/2" NPT Plug Steel 17 18 32 Drive Screw Stainless 33 Clapper Latch Bushing Bronze 21 32 27 A

Technical Support 989-1-2600 techservice@globesprinkler.com Customer Service 989-86-583 domesticsales@globesprinkler.com 2017 Globe Fire Sprinkler Corporation. All Rights Reserved. globesprinkler.com

077 Airpark Dr. Standish, MI 8658 989-86-583 www.globesprinkler.com Technical Support 989-1-2600 techservice@globesprinkler.com MODEL RCW FLOW CONTROL VALVE GENERAL DESCRIPTION The Globe Model RCW* Water Control Valve is a hydraulically operated external resetting differential latching style valve designed for use where quick-opening and total flooding of sprinkler system piping is desired. It is used as an automatic water control valve in Deluge, Dry Pipe, or Preaction systems, as well as foam-water sprinkler systems. Setting of the Model RCW Valve requires water pressure in the diaphragm chamber provided via a connection from the main water supply from a point upstream of the system main control valve, through a restricted orifice. Water pressure on the diaphragm is transferred to the plunger rod which forces the roller arm mechanism against the clapper, preventing the supply water from entering the sprinkler system piping. Actuation (tripping) of the Model RCW Valve is accomplished by releasing water from downstream of the restricted orifice. Water pressure release can be caused by a variety of types of actuation trim and devices. For example the supply can be fed to a line of wet pilot sprinklers for wet pilot type Deluge or Preaction systems. Other devices which can be used for valve actuation include a dry pilot actuator, or an electric solenoid valve with an associated releasing control panel. TECHNICAL DATA Approvals culus FM Note: When trimmed in accordance with Technical Literature: 1 GFV-205- Deluge System Technical Data Sheet 2 GFV-305- Dry System Technical Data Sheet 3 GFV-00- Single Interlock Preaction Technical Data Sheet GFV-10- Double Interlock Preaction Technical Data Sheet 5 GFV-20- Non Interlock Preaction Technical Data Sheet Maximum System Working Pressure 300 psi (20.6 Bar) Materials of Construction See Figure 1 Friction Loss Information See Figure 2 for Friction Loss Data " (DN100) Valve 13.13" (333,5mm) " (DN100) Valve w/ Model GLR300G 17.66" (8,5mm) 6" (DN150) Valve 1.7" (367,5mm) 6" (DN150) Valve w/ Model GLR300G Note: Take Out Dimensions (End to End) *Patents Pending 19.69" (500mm) MODEL RCW FLOW CONTROL VALVE MAINTENANCE Note: All valves should be carefully inspected, tested, and maintained in accordance with NFPA 25 or other applicable Standard. It is important to ensure a clean water supply free of debris and solid particles such as sand, gravel, or mud. If, during an inspection of a water control valve, sediment or free particles of matter are noted, a further examination of internal valve parts is necessary. All valves should be carefully inspected, tested, and maintained in accordance with NFPA 25 or other applicable Standard. It is important to ensure a clean water supply free of debris and solid particles such as sand, gravel, or mud. If, during an inspection of a water control valve, sediment or free particles of matter are noted, a further examination of internal valve parts is necessary. All deposits should be removed from all operating parts and ports. Vent holes through intermediate chamber should be thoroughly cleaned and flushed with clean water. JUNE 2017 GFV-200 (Formerly H-1) PAGE 1 OF 3

28 26 26 31 9 31 9 3 27 27 36 20 20 23 23 FIGURE 1:MODEL RCW MATERIALS OF CONSTRUCTION 8 1 1 32 22 8 17 12 12 33 1 1 10 10 13 30 30 7 7 19 2 2 19 6 6 15 15 16 18 313 3 35 11 5 5 2 2 25 21 SECTION A-A SECTION VIEW ISOMETRIC VIEW REV. REVISION REVISION METRIC UNITS SHOWN IN BRACKETS, DUE T MAY BE APPROXIMATE. LIMITS ON 2 PLC. DEC..010 [.3mm]; 3 PLC. DE ITEM DESCRIPTION MAT'L. 1 RCW BODY DI " [100mm] P/N 6" [150mm] P/N SEE ORDERING INFORMATION ITEM DESCRIPTION MAT'L. NOTE: SOME PARTS ARE NOT FIELD SERVICEABLE, CONTACT CUSTOMER SERVICE FOR AVAILABILITY " [100mm] P/N DR.BY: 6" [150mm] P/N 19 CLAPPER BRONZE 31703 31762 SCALE: NOT TO SCALE 2 MACHINED SEAT RING BRASS 31721 31767 20 RESET BUSHING BRASS 31706 31769 3 5 DIAPHRAGM TAPER SPRING CLAPPER RETAINER PLATE HEX HEAD CAP SCREW 1/2-13 X.75 STAINLESS 31732 31732 21 HEX HEAD CAP SCREW, 1/2-13 STEEL 31733 1 IN 317553 1.5 IN STAINLESS 31717 31770 22 TOP ARM BUSHING BRONZE 31711 31758 STAINLESS 317552 317552 23 TOP ARM PIN STAINLESS 31712 31772 6 CLAPPER GASKET EPDM 31716 31757 2 ROLLER ARM PIN STAINLESS 31709 3177 7 ROLLER ARM BRONZE 31713 31766 25 ROLLER PIN E-CLIP STAINLESS 31727 31779 8 RCW CLAPPER LATCH BRONZE 31722 31722 26 RESET PLUNGER KNOB BRONZE 31707 31707 9 RESET PLUNGER BRONZE 31708-31708-6 27 PLUNGER 0-RING EPDM 31736 31736 10 PUSH ROD BRONZE 31723 31768 28 NAME PLATE STAINLESS 31728 31728 11 ROLLER STAINLESS 31710 31778 29 DRIVE SCREW STEEL 32320 32320 12 DIAPHRAGM RETAINER BRONZE 31720 31765 30 LATCH RETURN SPRING STAINLESS 31725 31725 13 DIAPHRAGM EPDM 3170 31777 31 RESET PLUNGER SPRING STAINLESS 31726 31726 1 DIAPHRAGM COVER DI 31705 31763 32 1/2" NPT PIPE PLUG STEEL 311003 311003 15 CLAPPER HINGE PIN STAINLESS 31715 31775 33 ROLLER BUSHING BRONZE 3172 31782 16 CLAPPER HINGE PIN BUSHING BRONZE 3171 3171 3 17 COVER GASKET EPDM 31719 31773 35 18 MACHINED HAND HOLE COVER PLUNGER BUSHING 0-RING, #2-01 1/2-13 HEX HEAD CAP SCREW (COVER BOLTS) EPDM 31735 31735 STEEL 31756 1 IN 317551 1.25 IN DI 31718 3176 36 RESET PLUNGER END BRONZE 317378 317378 0 ST 31700 FOR A Where difficulty in performance is experienced, the damaged (e.g., foreign matter embedded in the surface), manufacturer or its authorized representative shall the facing should be replaced. If it is dirty, it should be be contacted before any field adjustment is to be cleaned. Compounds which could damage the rubber facing must never be used. made. Clapper Facing. The rubber clapper facing should be Seat Ring. The seat ring should be checked for nicks and checked for wear or damage to determine that it is free of for stones, dirt or other foreign matter lodged in the grooves dirt and other foreign substances. If found to be worn or or holes. It should be cleaned thoroughly. If the seat ring is found to be damaged, valve should be replaced. JUNE 2017 GFV-200 (Formerly H-1) PAGE 2 OF 3

FIGURE 2:FRICTION LOSS CURVES " (DN100) 6" (DN150) The approximate friction loss, based on the hazen- williams formula; expressed in equivalent length of pipe with c=120, is as follows: 1 11 Ft (3,35 m) of equivalent length of schedule 0 " (DN100) piping for " (DN100) valve 2 2 Ft (12,8 m) of equivalent length of schedule 0 6" (DN150) piping for 6" (DN150) valve Alarm Line Check Valve. The ¾ check valve connected to the intermediate chamber should be checked for clapper and seat condition. RCW Valve. Main Drain Valve and all controlling valves which are normally closed when the deluge valve is in the set position should be checked to be sure that they are fully closed and not leaking. TESTING / INSTALLATION See appropriate system Technical Literature for Testing and Installation Instructions. ORDERING INFORMATION RCW Water Control Valve (Groove X Groove) Specify: RCW-2 Valve Only (specify valve size), PN inch RCW GxG............ 31700 6 inch RCW GxG............ 317550 DN 150 (165,1 mm) RCW GXG.... 317550-D GLOBE PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 077 Airpark Dr. Standish, MI 8658 Ph. 989-86-583 Technical Support 1-800-28-0278 techservice@globesprinkler.com www.globesprinkler.com JUNE 2017 GFV-200 (Formerly H-1) PAGE 3 OF 3