Features 1. Differential Latch-type, lightweight, dependable

Similar documents
Model DDX Deluge Valve 8 (200mm) Features

Model DDX Deluge Valves 4" (100 mm), 6" (150 mm) and 165 mm Sizes

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation Care and Maintenance

AGCX Bulletin 519 C/Alfoz de Bricia nº4 P.l. Villalonquéjar Burgos (Spain) Tlfno: PAG 1 de 50

Instructions for Installation, Operation, Care, and Maintenance

Instructions for Installation, Operation, Care and Maintenance 2 PSI (0,14 bar) Pneumatic Supervising Pressure with Electric Actuation

Instructions for Installation, Operation, Care and Maintenance

Model F1 Res Sprinklers engineered for the lowest flows to meet the minimum design density of.05 gpm/ft 2

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York Bulletin 617 Rev. C

Instructions for Installation, Operation, Care and Maintenance

Model F1 Model F1 Recessed Standard Response Sprinklers

Series 758 FireLock Actuated System Valve

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

TECHNICAL DATA. Q= C v P S

Instructions for Installation, Operation, Care and Maintenance

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

TECHNICAL DATA CONCENTRATE CONTROL VALVE APPLICATIONS, PRIMING CONNECTIONS, AND TRIMS 1. GENERAL DESCRIPTION 2. LISTINGS AND APPROVALS.

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

SHORTER. LIGHTER. MORE VERSATILE. 1 VALVE 10 TRIM CONFIGURATIONS 4" AND 6" MODEL RCW WATER CONTROL VALVE FOR DRY, PREACTION AND DELUGE APPLICATIONS

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

DELUGE VALVE DATA SHEET

1-1/2 Inch (DN40) 9 lb (4,1 kg) Groove Groove 1 8 lb (3,6 kg) Flange Groove 1 N/A N/A. Flange Flange N/A N/A

DV-5 Deluge Valve Aluminium Bronze Diaphragm Style General Description

Easy Riser swing check valve Models E-1 & F-1

TECHNICAL DATA 1-1/2 (dn40)

MODEL RCW NON-INTERLOCK PREACTION SYSTEM

DV-5a Automatic Water Control Valve Double Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

TotalPac 3 Firecyle III Wet pipe Remote controlled system

TotalPac 3 Deluge, Electric release Remote controlled system

TotalPac 3 Deluge system Pneumatic release

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

GW MKIII DELUGE VALVE - ALUBRONZE EXTERNAL RESET, PNEUMATIC

MODEL RCW DELUGE SYSTEM ELECTRIC, WET PILOT, AND DRY PILOT ACTUATION

FRAME STYLE SPRAY NOZZLES TECHNICAL DATA

TECHNICAL DATA. Trimpac 249a. September 16, 2013

Series 769 FireLock NXT Deluge Valve

Section R Foam Systems

TECHNICAL DATA OBSOLETE

Section R Foam Systems

Wet pipe low flow foam/water manifold system

Sl. No. Description Pages

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

TECHNICAL DATA TRIMPAC MODEL B-4, B-4B & B-4S SINGLE INTERLOCK PREACTION SYSTEM WITH PNEUMATIC RELEASE

DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Wet Pilot Actuation General Description

Series 756 FireLock Dry System Check Valve

TotalPac 3 Non interlock Preaction system Pneumatic release

TECHNICAL DATA. Trimpac 244a. April 15, 2011

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

TotalPac 3 Double interlock Firecyle III Preaction Remote controlled system

TECHNICAL DATA OBSOLETE

FireFlex DUAL Single Interlock, Remote controlled system

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Remote controlled system

TotalPac 3 Double interlock Preaction, Electric/Pneumatic release Remote controlled system

TotalPac 3 Non interlock Preaction, Electric release Remote controlled system

TECHNICAL DATA 2-1/2-8 (dn65 - dn200)

model E Spray nozzles vk810 - vk817

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL H-2 HALAR COATED 2 (DN50) - 6 (DN150)

Maxon Shut-Off and Vent Valves General Purpose

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL J-2 HALAR COATED 1-1/2 & 2 (DN40 & DN50) 1. DESCRIPTION

Q= C v P S. Flow control valve Model j-2 Halar coated

TECHNICAL DATA CAUTION

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11

Preaction System with DV-5 Deluge Valve Double Interlock Electric/Electric Actuation. General Description. Page 1 of 14 DECEMBER 2014 TFP1465

TECHNICAL DATA OBSOLETE. Inlet Type Outlet Type in mm. Thread Thread in. ANSI B Flanged Flanged in.

CJ=TN=- FRONT DELUGE VALVE, EXTERNAL RESETTING. MODEL F470 MULTIMATIW - 4 and 6 INCH (100 and 150 mm) a P il

EMERGENCY SHUTOFF AND FIRESAFE VALVES FIGURE 1075

Grooved Piping System for Fire Protection Services

TECHNICAL DATA. Q= C v P S. Table 1 - Valve Part Numbers and Specifications

SOLID CONE SPRAY NOZZLES TECHNICAL DATA

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 2-4

DV-5A Automatic Water Control Valve Remote-Resetting Deluge Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

TECHNICAL DATA P S. Q= Cv MODEL E-2 DELUGE VALVE HALAR COATED ANGLE STYLE

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

Grooved Piping System for Fire Protection Services

Series 751 FireLock European Alarm Check Valve Stations

Technical Data. UL Listing is based on the following criteria:

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

TECHNICAL DATA VK810 (65 ) VK811 (80 ) VK812 (95 ) VK813 (110 )

TECHNICAL DATA. mixture, with a freeze temperature

January 2007 Approval Guide Fixed Extinguishing Systems 5-57

TECHNICAL DATA OBSOLETE

FireLock NXT Actuated Valve with Preaction Trim. System No. Submitted By Spec Sect Para Location Date Approved Date

Installation Manual DIAPHRAGM WELL TANK

Worldwide Contacts.

TECHNICAL DATA. Table Standard Materials

mirage standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (K5.6)

Hydraulic Concentrate Control Valve

Date: Project #: Engineer: Prepared By: Bid Date:

MARINE INERGEN 150-BAR SYSTEMS Component Sheet Library

ALARM CHECK VALVE 3", 4" & 6" MODEL H-1 FLANGE/FLANGE 3" & 4" MODEL H-2 GROOVE/GROOVE 3", 4" & 6" MODEL H-3 FLANGE/GROOVE

GROOVED COUPLINGS - STANDARD FLEXIBLE Model 101

Installation Manual FTI-10A & FTI-20A SINGLE TANK. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

Deluge Valves. Model 68 DE\ HM-MR. Hydraulically Actuated Manual-Reset Deluge Valve. Dorot Fire Protection Division

Data Sheet 3.03 Issue D

Transcription:

Bulletin 516 Rev. B Model DDX-SS Deluge Valve (100mm), (150mm) & (200mm) Bulletin 516 Rev. B Features 1. Differential Latch-type, lightweight, dependable construction. 2. Easily trimmed for releasing by: Manual pull stations Wet pilot sprinklers Dry pilot actuators Solenoid valves 3. Screw in seat & clapper assembly simplifies maintenance. 4. Stainless steel construction to resist corrosion. 5. Pressure-actuated clapper facing provides dependable seal. 6. Reset externally. Cover removal is not required. 7. Grooved or Flanged inlet and outlet connections. 8. Drain valve to drain standing water column. 9. Valve latches in open position. No pressure operated relief valve is required. 10. Pressure rating of 250 psi (17,2 bar). Fig. 1 Listings & Approvals (Only when used with Reliable s Trim Sets.) 1. Listed by Underwriters Laboratories, Inc. and UL certified for Canada (culus). 2. Certified by Factory Mutual Approvals (FM). The Reliable Model DDX-SS Deluge Valve is a hydraulically operated, latching clapper-type valve used to control the water supply to a deluge or preaction system. Deluge systems use open sprinklers or nozzles as discharge outlets in the fire area, while preaction systems use closed sprinklers or nozzles. Both systems use separate detection devices to control the operation of the Deluge Valve. Three simple trim arrangements allow for actuation of the Reliable Model DDX-SS Deluge Valve by utilizing manual, hydraulic, pneumatic, or electrical devices. These devices include break glass stations, wet pilot sprinklers, dry pilot sprinklers, thermal detectors, and smoke detectors. The Reliable Model DDX-SS Deluge Valve can be reset externally, without cover removal. This is accomplished by pushing in and turning the external reset knob at the rear of the Deluge Valve (see Fig. 2). Fig. 2 The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523

Valve Operation The Reliable Model DDX-SS Deluge Valve is shown in both closed and open positions in Fig. 3. In the closed position, the supply pressure acts on the underside of the clapper and also on the push rod through the push rod chamber s inlet restriction. The resultant force due to the supply pressure acting on the push rod is multiplied by the mechanical advantage of the lever and is more than sufficient to hold the clapper closed against normal supply pressure surges. When a fire is detected, a releasing device vents the push rod chamber to atmosphere through the chamber s outlet. Since the pressure cannot be replenished through the inlet restriction as rapidly as it is vented, the push rod chamber pressure falls instantaneously. When the push rod chamber pressure approaches approximately one third of the supply pressure, the upward force of the supply pressure acting beneath the clapper overcomes the lever-applied force thereby opening the clapper. Once the clapper has opened, the lever acts as a latch, preventing the clapper from returning to the closed position. Water from the supply flows through the Deluge Valve into the system piping. Water also flows through the Deluge Valve s alarm outlet to the alarm devices. After system shutdown, resetting the Model DDX-SS Deluge Valve is quite simple. Doing so only requires pushing in and turning the reset knob at the rear of the valve (see Fig. 2). The external reset feature of the Model DDX-SS Deluge Valve provides a means for simple, economical system testing, which is one essential facet of a good maintenance program. The external reset feature does not, however, eliminate another important facet of good maintenance, namely, periodic cleaning and inspection of the internal valve parts. In the event that water builds up inside the valve due to condensate from the air supply system, or water left inside from valve system testing, a drain is available for venting. After closing the main supply valve, a small valve over the drain cup can be opened slightly until the water inside the valve body and the main pipe column has drained. Whenever ambient temperature conditions are high, the water temperature in the Model DDX-SS Deluge Valve s pushrod chamber could possibly increase, thereby increasing the pressure in the chamber to values exceeding the rated pressure of the system. In an indoor installation where standard room temperatures are exceeded, a pressure relief kit may be needed. Pressure relief kit, P/N 6503050001, can be installed into the pushrod chamber s releasing line to limit the pressure to 250 psi (17,2 bar). Reliable Model DDX-SS Deluge Valve with associated trim size [ (100mm)][ (150mm)][ (200mm)], is rated for use at a minimum water supply pressure of 20 psi (1,4 bar) and a maximum water supply pressure of 250 psi (17,2 bar). Water supplied to the inlet of the valve and to the push rod chamber must be maintained between 40 F (4 C) and 140 F (60 C). 2. Detection and Actuation In general, the Reliable Model DDX-SS Deluge Valve can be released by any Reliable UL Listed or FM Approved device that opens sufficiently to vent the push rod chamber in response to a fire. The releasing device is simply connected to the push rod chamber s outlet. When the releasing device operates and vents the push rod chamber, the Deluge Valve opens. Typical releasing devices include hydraulic manual emergency stations, Model F1-FTR Fixed Temperature Detectors on wet pilot lines, dry pilot actuators, and solenoid valves. Model F1-FTR Detectors perform both Deluge Valve releasing and fire detection functions with wet pilot lines. The use of a solenoid valve for Deluge Valve releasing enables various types of electrical fire detection devices to be used. Typical detection devices include electrical emergency pull stations, thermal detectors, and ionization or photoelectric smoke detectors. Electrical detection and releasing equipment used in Electrical Systems is described in Bulletins 700 and 722, for both deluge and preaction systems. Fig. 3 Model DDX-SS Deluge Valve Description 1. Rated working pressure: Valve & System - 250 psi (17.2 bar). 2. Factory tested to a hydrostatic pressure of 500 psi (34,5 bar). (Valve only) 3. End and trim connections: ANSI/AWWA C606 grooved inlet and outlet Nominal Pipe Size 4" 6" 8" Outlet Diameter 4.500" (114mm) 6.625" (168mm) 8.625" (219mm) Groove Dimension Groove Diameter 4.334" (110mm) 6.455" (164mm) 8.441" (214mm) Groove Width 3/8" (9.5mm) 3/8" (9.5mm) 7/16" (11mm) Outlet Face to Groove 5/8" (16mm) 5/8" (16mm) (19mm)

Nominal Pipe Size 4" 6" 8" ASME B16.5 Flanged inlet and outlet Class Rating 150 300 150 300 150 300 Note: Due to thickness of flange, the Class 150 bolt length is 1/2 (12.7 mm) longer than normally recommended per ASME B16.5 Threaded openings Per ANSI B 2.1 4. Valve Exterior s Color: Natural 5. Face to Face Dimensions: Nominal Pipe Size Groove/ Groove Flange/ Flange 1 (356mm) 1 (406mm) 1 (406mm) 1 (457mm) 19 3 / (492mm) 21¼ (540mm) 6. Shipping weight: Valve Shipping Weight Bolt Circle 7.50" (191mm) 7.88" (200mm) 9.50" (241mm) 10.62" (270mm) 11.75" (298mm) 13" (330mm) Flange Dimensions Bolt Hole Diameter (19.1mm) 7/8" (22.2mm) 7/8" (22.2mm) 7/8" (22.2mm) 7/8" (22.2mm) 1" (25.4mm) Number of Bolts Grv/Grv Flg/Flg Grv/Grv Flg/Flg Bolt Diameter Recommended Bolt Length Machine Stud Bolt Bolt 68 lbs (30,8 kg) 110 lbs (49,9 kg) 101 lbs (45,8 kg) 170 lbs (77,1 kg) Grv/Grv 159 lbs (72,1 kg) Flg/Flg 259 lbs (117,5 kg) Trim Shipping Weight Trim Configuration Weight Wet Pilot Deluge 32 lbs (14,5 kg) Dry Pilot Deluge 43 lbs (19,5 kg) Electric Actuation Deluge 34 lbs (15,4 kg) 7. Friction loss (Expressed in equivalent length of Schedule 40 pipe, based on Hazen & Williams formula with C=120: Valve Size Equivalent Length (100mm) 14.9 ft (4.54 m) (150mm) 31.8 ft (9.69 m) (200mm) 53.5 ft (16,31 m) 8. Installation position: Vertical Trim Descriptions The trims for the Reliable Model DDX-SS Deluge Valve are arranged for rapid, easy, and compact attachment, and serve as connection points to Reliable Model C Mechanical Alarms and other devices. All Model DDX-SS Trim sets are available in 304 stainless steel or 316 stainless steel versions. The available Model DDX-SS Deluge Valve trim sets are: Wet Pilot Trim Dry Pilot Trim Electric Actuation Trim 8 8 8 12 8 12 5/8" (16mm) (19.1mm) (19.1mm) (19.1mm) (19.1mm) 7/8" (22.2mm) 3.50" (88.9mm) 3.75" (95.3mm) 3.75" (95.3mm) 4.25" (108.0mm) 4.00" (101.6mm) 4.75" (120.7mm) 4.00" (101.6mm) 4.50" (114.3mm) 4.50" (114.3mm) 4.75" (120.7mm) 4.75" (120.7mm) 5.50" (139.7mm) The Wet Pilot Trim (see Fig. 4) is used when wet pilot sprinklers or hydraulic manual emergency pull boxes are used for detection and releasing. This trim set provides a two inch main drain, alarm test, supply pressure gauge, push rod chamber pressure gauge, push rod chamber supply connections, Model B-SS Hydraulic Manual Emergency Station, and a connection for releasing devices. The Dry Pilot Trim (see Fig. 5) is used when dry pilot sprinklers are used as the fire detection means. This trim set includes the Model LP-SS Dry Pilot Line Actuator, air and water pressure gauges, low air pressure switch (for Dry Pilot Line), air pressure relief valve, connections for the air supply and pilot sprinkler lines, a two inch main drain, alarm test, push rod chamber connections, push rod chamber pressure gauge, and the Model B-SS Hydraulic Manual Emergency Station. Table A provides the recommended air pressure when the dry pilot trim set is used as the actuation means. Table A Water Pressure psi (bar) Pneumatic Pressure to be Pumped into Sprinkler System psi (bar) Maximum Not Les Than Not More Than 20 (1.4) 10 (.7) 14 (1.) 50 (3.4) 12 (.8) 16 (1.1) 75 (5.2) 13 (.9) 17 (1.2) 100 (6.9) 15 (1.) 19 (1.3) 125 (8.6) 16 (1.1) 20 (1.4) 150 (10.3) 17 (1.2) 21 (1.4) 175 (12.1) 18 (1.2) 22 (1.5) 200 (13.8) 19 (1.3) 23 (1.6) 225 (15.5) 21 (1.4) 25 (1.7) 250 (17.2) 22 (1.5) 26 (1.8) *Note: During system set-up, a higher pneumatic pressure may be required in order to properly set the Model LP Dry Valve Actuator. The Electric Actuation Trim (see Fig. 6) is used when electric detection and releasing are desired. This trim set includes a solenoid valve 250 psi (17,2 bar) rated, two inch main drain, alarm test supply pressure gauge, push rod chamber supply connections, push rod chamber pressure gauge, and the Model B-SS Hydraulic Manual Emergency Station. Detailed description of electrical operation can be found in Bulletins 700 and 722. The Model B-SS Hydraulic Manual Emergency Station is a standard item in all trim sets. However, the Model A Hydraulic Manual Emergency Station, described in Bulletin 506, is also available as an option. All Model DDX-SS Deluge Valves are listed by Underwriters Laboratories, Inc, and certified by UL for Canada (cu- Lus) and certified by Factory Mutual Approvals, only when used with the valve manufacturer s trim sets. 3.

4. Fig. 4

5. Fig. 5

6. Fig. 6

Ordering Information Specify: Valve Model & Size (100 mm) Grv/Grv (P/N 6103040037), (100 mm) Flg/Flg Class 150 (P/N 6103040039), (100 mm) Flg/Flg Class 300 (P/N 6103040040), (150 mm) Grv/Grv (P/N 6103060037), (150 mm) Flg/Flg Class 150 (P/N 6103060039), (150 mm) Flg/Flg Class 300 (P/N 6103060040), (200 mm) Grv/Grv (P/N 6103080002), (200 mm) Flg/Flg Class 150 (P/N 6103080005), (200 mm) Flg/Flg Class 300 (P/N 6103080006). Trim Wet Pilot Trim, Dry Pilot Trim, or Electric Actuation Trim. Each trim set is available in individual parts, in time-saving, segmentally assembled kit forms, or fully assembled to the Model DDX-SS Deluge Valve without a control valve. All trims are available in 304 stainless steel or 316 stainless steel version. The Electric Actuation trim includes a 250 psi (17,2 bar) rated solenoid valve. Wet Pilot Line Deluge Size 304 Trim Configurations Trim Part Numbers Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505041201 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505041202 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505041203 Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505061201 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505061202 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505061203 Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505081201 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505081202 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505081203 Segmentally Assembled (DDX Valve Sold Separately) 6503001025, & Individual Parts (DDX Valve Sold Separately) 6503001024 Size 316 Trim Configurations Trim Part Numbers Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505042201 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505042202 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505042203 Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505062201 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505062202 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505062203 Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505082201 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505082202 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505082203 Segmentally Assembled (DDX Valve Sold Separately) 6503001027, & Individual Parts (DDX Valve Sold Separately) 6503001026 7.

Dry Pilot Line Deluge UL/FM Approved Pressure Switch ULC Approved Pressure Switch UL/FM Approved Pressure Switch ULC Approved Pressure Switch { { {{ Size 304 Trim Configurations Trim Part Numbers Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505041206 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505041207 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505041208 Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505061206 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505061207 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505061208 Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505081206 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505081207 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505081208 Segmentally Assembled (DDX Valve Sold Separately) 6503001132, & Individual Parts (DDX Valve Sold Separately) 6503001131 Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505041209 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505041210 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505041211 Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505061209 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505061210 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505061211 Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505081209 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505081210 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505081211 Segmentally Assembled (DDX Valve Sold Separately) 6503001134, & Individual Parts (DDX Valve Sold Separately) 6503001133 Size 316 Trim Configurations Trim Part Numbers Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505042206 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505042207 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505042208 Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505062206 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505062207 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505062208 Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505082206 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505082207 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505082208 Segmentally Assembled (DDX Valve Sold Separately) 6503001136, & Individual Parts (DDX Valve Sold Separately) 6503001135 Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505042209 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505042210 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505042211 Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505062209 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505062210 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505062211 Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505082209 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505082215 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505082216 Segmentally Assembled (DDX Valve Sold Separately) 6503001138, & Individual Parts (DDX Valve Sold Separately) 6503001137 8.

Electric Actuation Deluge (Explosion Proof Solenoid Available Upon Request) Size 304 Trim Configurations Trim Part Numbers Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505041212 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505041213 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505041214 Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505061212 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505061213 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505061214 Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505081212 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505081213 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505081214 Segmentally Assembled (DDX-SS Valve Sold Separately) 6503001530, & Individual Parts (DDX-SS Valve Sold Separately) 6503001529 Size 316 Trim Configurations Trim Part Numbers Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505042212 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505042213 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505042214 Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505062212 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505062213 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505062214 Fully Assembled to Grv/Grv DDX-SS Valve w/o Control Valve 6505082212 Fully Assembled to Flg/Flg Class 150 DDX-SS Valve w/o Control Valve 6505082213 Fully Assembled to Flg/Flg Class 300 DDX-SS Valve w/o Control Valve 6505082214 Segmentally Assembled (DDX-SS Valve Sold Separately) 6503001536, & Individual Parts (DDX-SS Valve Sold Separately) 6503001535 Note: For metric installations, a 2 NPT x R2. ISO 7/1 x Close Nipple (Reliable P/N 98543401) is sold separately as an adapter for the single drain outlet of the trims. Additional equipment Air compressors, electric detection, actuation equipment, and mechanical sprinkler alarms must be ordered separately. These devices are described in Bulletin 700. 9.

Nominal Pipe Size Installation Dimensions in Inches (mm) A B C D* D** E F G H J K L M N P Q R 10½ (267) 10½ (267) 10½ (267) 7¾ (197) 9¼ (235) 10 (254) 10¾ (273) 11½ (292) D* is for groove-groove versions D** is for flange-flange versions 14 (356) 16 (406) 19 3 / 8 (492) 16 (406) 18 (457) 21¼ (540) 29¾ (756) 31½ (800) 31¾ (807) 23¾ (603) 25½ (648) 25¾ (654) 31 (787) 32¾ (832) 33 (838) 7¾ (197) 8¼ (210) 9 (229) 15¾ (400) 16¼ (413) 17 (432) 7 (178) 7 (178) 7 (178) 17 (432) 18 (457) 17 (432) 8 (203) 10½ (267) 10½ (267) 10 (254) 11½ (292) 11¾ (298) 12¼ (311) 13¾ (349) 14¼ (362) 15 (381) The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 11/12 P/N 9999970375