AGCX Bulletin 519 C/Alfoz de Bricia nº4 P.l. Villalonquéjar Burgos (Spain) Tlfno: PAG 1 de 50

Similar documents
Instructions for Installation, Operation, Care and Maintenance

Features 1. Differential Latch-type, lightweight, dependable

Instructions for Installation, Operation, Care, and Maintenance

Model DDX Deluge Valves 4" (100 mm), 6" (150 mm) and 165 mm Sizes

Model DDX Deluge Valve 8 (200mm) Features

Instructions for Installation, Operation, Care and Maintenance 2 PSI (0,14 bar) Pneumatic Supervising Pressure with Electric Actuation

TECHNICAL DATA. Q= C v P S

Instructions for Installation, Operation, Care and Maintenance

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

Instructions for Installation, Operation, Care and Maintenance

DELUGE VALVE DATA SHEET

Instructions for Installation, Operation, Care and Maintenance

TECHNICAL DATA 1-1/2 (dn40)

DV-5a Automatic Water Control Valve Double Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

Instructions for Installation, Operation Care and Maintenance

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

Series 758 FireLock Actuated System Valve

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Instructions for Installation, Operation, Care and Maintenance

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

TECHNICAL DATA CONCENTRATE CONTROL VALVE APPLICATIONS, PRIMING CONNECTIONS, AND TRIMS 1. GENERAL DESCRIPTION 2. LISTINGS AND APPROVALS.

MODEL RCW DELUGE SYSTEM ELECTRIC, WET PILOT, AND DRY PILOT ACTUATION

MODEL RCW NON-INTERLOCK PREACTION SYSTEM

Series 769 FireLock NXT Deluge Valve

1-1/2 Inch (DN40) 9 lb (4,1 kg) Groove Groove 1 8 lb (3,6 kg) Flange Groove 1 N/A N/A. Flange Flange N/A N/A

DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Wet Pilot Actuation General Description

Instructions for Installation, Operation, Care and Maintenance

Series 756 FireLock Dry System Check Valve

Worldwide Contacts.

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11

TotalPac 3 Deluge, Electric release Remote controlled system

TECHNICAL DATA. Trimpac 249a. September 16, 2013

TotalPac 3 Firecyle III Wet pipe Remote controlled system

Preaction System with DV-5 Deluge Valve Double Interlock Electric/Electric Actuation. General Description. Page 1 of 14 DECEMBER 2014 TFP1465

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

TECHNICAL DATA. Trimpac 244a. April 15, 2011

DV-5 Deluge Valve Aluminium Bronze Diaphragm Style General Description

Technical Data. UL Listing is based on the following criteria:

Easy Riser swing check valve Models E-1 & F-1

GW MKIII DELUGE VALVE - ALUBRONZE EXTERNAL RESET, PNEUMATIC

TotalPac 3 Deluge system Pneumatic release

TECHNICAL DATA TRIMPAC MODEL B-4, B-4B & B-4S SINGLE INTERLOCK PREACTION SYSTEM WITH PNEUMATIC RELEASE

TECHNICAL DATA 2-1/2-8 (dn65 - dn200)

TotalPac 3 Non interlock Preaction system Pneumatic release

TotalPac 3 Non interlock Preaction, Electric release Remote controlled system

SHORTER. LIGHTER. MORE VERSATILE. 1 VALVE 10 TRIM CONFIGURATIONS 4" AND 6" MODEL RCW WATER CONTROL VALVE FOR DRY, PREACTION AND DELUGE APPLICATIONS

TotalPac 3 Double interlock Preaction, Electric/Pneumatic release Remote controlled system

TECHNICAL DATA P S. Q= Cv MODEL E-2 DELUGE VALVE HALAR COATED ANGLE STYLE

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Remote controlled system

Wet pipe low flow foam/water manifold system

Q= C v P S. Flow control valve Model j-2 Halar coated

TECHNICAL DATA CAUTION

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL H-2 HALAR COATED 2 (DN50) - 6 (DN150)

FireLock NXT Actuated Valve with Preaction Trim. System No. Submitted By Spec Sect Para Location Date Approved Date

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL J-2 HALAR COATED 1-1/2 & 2 (DN40 & DN50) 1. DESCRIPTION

DV-5A Automatic Water Control Valve Remote-Resetting Deluge Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 2-4

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

TotalPac 3 Double interlock Firecyle III Preaction Remote controlled system

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

Series 751 FireLock European Alarm Check Valve Stations

PRESSURE RELIEF / SUSTAINING CONTROL VALVES

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

SOLENOID CONTROL VALVE

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

PRESSURE REDUCING CONTROL VALVES

Grooved Piping System for Fire Protection Services

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

TECHNICAL DATA. Q= C v P S. Table 1 - Valve Part Numbers and Specifications

Deluge Valves. Model 68 DE\ HM-MR. Hydraulically Actuated Manual-Reset Deluge Valve. Dorot Fire Protection Division

ALTITUDE CONTROL VALVES FOR ONE WAY FLOW

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

Section R Foam Systems

Section R Foam Systems

PRESSURE REDUCING CONTROL VALVE

TECHNICAL DATA OBSOLETE. Inlet Type Outlet Type in mm. Thread Thread in. ANSI B Flanged Flanged in.

Technical Data Sheet SEVO 1230 Clean Agent Cylinders

TECHNICAL DATA OBSOLETE

Deep Well Pump Control Valve

FLOAT CONTROL VALVES

Grooved Piping System for Fire Protection Services

S v S e r i e s F M f i r e e x t i n g u i s h i n g s y s t e m

Deluge Pressure Reducing Valves. Model 68 DE\ EL\ PORV\ PR. Electrically and Pneumatically Actuated, Pressure Reducing, Remote-Reset, Deluge Valve

FireFlex DUAL Single Interlock, Remote controlled system

MODULATING FLOAT CONTROL VALVE

Deluge Pressure Reducing Valves. Model 68 DE\ RCL\ PR. Electrically Actuated, Manual-Reset, Pressure Reducing, Deluge Valve

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

Deluge Valves. Model 68 DE\ HRV-MR. Hydraulically Actuated, Anti-Columning, Manual-Reset Deluge Valve. Dorot Fire Protection Division

PRESSURE REDUCING VALVE

CJ=TN=- FRONT DELUGE VALVE, EXTERNAL RESETTING. MODEL F470 MULTIMATIW - 4 and 6 INCH (100 and 150 mm) a P il

A. This Section includes natural gas piping, specialties, and accessories within the building.

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

TECHNICAL DATA. Table Standard Materials

FRAME STYLE SPRAY NOZZLES TECHNICAL DATA

Transcription:

Instructions for Installation, Operation, Care and Maintenance Model AGCX Deluge Valve (50 mm), ½ (65 mm), 3 (80 mm), 4 (00 mm), 6 (50 mm), 8 (00 mm) Wet Pilot Line, Dry Pilot Line, and Electric Actuation Trims, Electro-Pneumatic Actuation Trims,Combination of Electric or Dry Pilot Line Actuation Trims PAG de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

GENERAL The AG Sprinkler Model AGCX Deluge Valve is a hydraulically operated, differential latching clapper-type valve designed for use as primary control valve in deluge, preaction, or special types of fire protection systems. Following operation, the valve is easily reset externally (see Fig.). The Wet Pilot Line Trim set is connected to the push rod chamber outlet and provides a one and one quarter inch main drain on (50mm), ½ (65mm), 3 (80mm) valve sizes or a two inch main drain on 4 (00mm), 6 (50mm) and 8 (00mm) valve sizes, alarm test, supply pressure gauge, and the push rod chamber supply connections. Releasing devices that can be used are wet pilot line detectors (Model F-FTR) or hydraulic manual emergency stations/pull boxes (Models A & B). Two alternate or combined actuation trim sets, Dry Pilot Line or Electric Actuation, are available when dry pilot sprinklers or solenoid valves are used for releasing. Actuation by solenoid valves enables a full range of electrical detectors to be used for remote sensing. LISTINGS & APPROVALS (Only when used with Trim Sets.). Listed by Underwriters Laboratories, Inc. and UL certified for Canada (culus).. Certified by Factory Mutual Approvals (FM). 3. LPCB (4 (00mm), 65mm, 6 (50mm) & 8 (00mm) only) 4. CE 5. VdS Schadenverhütung GmbH VALVE OPERATION The AG Sprinkler Model AGCX Deluge Valve is shown in both closed and open positions in Fig.. In the closed position, the supply pressure acts on the underside of the clapper and also on the push rod through the push rod chamber s inlet restriction. The resultant force due to the supply pressure acting on the push rod is multiplied by the mechanical advantage of the lever and is more than sufficient to hold the clapper closed against normal supply pressure surges. When a fire is detected, a releasing device vents the push rod chamber to atmosphere through the chamber s outlet. Since the pressure cannot be replenished through the inlet restriction as rapidly as it is vented, the push rod chamber pressure falls instantaneously. When the push rod chamber pressure approaches approximately one-third of the supply pressure, the upward force of the supply pressure acting beneath the clapper overcomes the lever-applied force thereby opening the clapper. Once the clapper has opened, the lever acts as a latch, preventing the clapper from returning to the closed position. Water from the supply flows through the Deluge Valve into the system piping. Water also flows through the Deluge Valve alarm outlet to the alarm devices. After system shutdown, resetting the Model AGCX Deluge Valve is quite simple. Doing so only requires pushing in and turning the reset knob at the rear of the valve (see Fig.). The external reset feature of the Model AGCX Deluge Valve provides a means for simple, economical system testing, which is one essential acet of a good maintenance program. The external reset feature does not, however, eliminate another important facet of good maintenance, namely, periodic cleaning and inspection of the internal valve parts. In the event that water builds up inside the valve due to condensate from the air supply system or water left inside from valve system testing, a drain is available for venting. After closing the main supply valve, a small valve over the drain cup can be opened slightly until the water inside the valve body and the main pipe column has drained. Whenever ambient temperature conditions are high, the water temperature in the Model AGCX Deluge Valve s pushrod chamber could possibly increase, thereby increasing the pressure in the chamber to values exceeding the rated pressure of the system. In an indoor installation where standard room temperatures are exceeded, a pressure relief kit may be needed. Pressure relief kit, can be installed into the pushrod chamber s release line to limit the pressure to 50 psi (7, bar). AG Sprinkler Model AGCX Deluge Valve with associated trim sizes (50 mm), ½ (65 mm), 3 (80 mm), 4 (00 mm), 6 (50 mm) and 8 (00 mm) are rated for use at a minimum water supply pressure of 0 psi (,4 bar) and a maximum water supply pressure of 50 psi (7, bar) for (50mm), / (65mm), 3 (80mm), 8 (00mm) valve sizes and 300 psi (0,7 bar) for 4 (00mm), 6 (50mm) valve sizes). Water supplied to the inlet of the valve and to the push rod chamber must be maintained between 40 F(4 C) and 40 F(60 C). PRESSURIZING LINE CONNECTION The water supply for the push-rod chamber must be provided by connection of its inlet pressurizing line to the water supply piping. Pressurizing lines for multiple Model AGCX Deluge Valve push-rod chambers must never be manifolded together, having only a single tap on the water supply piping. Each Model AGCX Deluge Valve must have its own push-rod chamber pressurizing line connection. This connection must be made on the supply side of the water supply control valve (see Fig. 4 or Fig. 5). This can be accomplished by: Using a tapped connection directly below or next to the main water supply control valve using a welded outlet or the appropriate mechanical fittings. A grooved-end outlet coupling is one way to achieve this; or PAG de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

Using a water supply control valve that has an available threaded (NPT) supply-side tap design to allow for a direct water supply connection to the Model AGCX Deluge Valve s push-rod chamber. Caution: AG Sprinkler AGCX valve is designed with an inlet restriction built into the pushrod chamber. It is important not to introduce additional restrictions into the direct water supply connection or the discharge from the pushrod chamber by installing additional valves or improperly installing the copper lines used in the trim of the valve. PAG 3 de 50 Fig. HYDROSTATIC TESTING OF AGCX VALVES AND AGCX SYSTEMS As required by NFPA 3, fire sprinkler systems with working pressures up to and including 50 psi are to be hydrostatically tested at a water pressure of 00 psi and maintain that pressure without loss for two hours. Fire sprinkler systems with working pressures above 50 psi are required to be hydrostatically tested at 50 psi above the system working pressure and maintain that pressure without loss for two hours. In addition to the hydrostatic tests described above, dry pipe and double interlock preaction systems require an additional low pressure air test. In some cases, hydrostatic testing (in accordance with the NFPA 3 requirements noted above) will result in pressures that exceed the working pressure of the valve and trim kit for the two-hour test period. The valve and applicable trim kit have been tested, approved and listed under these conditions and as such, hydrostatic testing in accordance with NFPA 3 is acceptable. In addition, the clapper can remain in the closed position and the trim kit need not be isolated, as each has been designed to withstand hydrostatic testing as required by NFPA 3. Hydrostatically testing the valve and trim to pressures higher than their rating is limited to the hydrostatic test as referenced by NFPA 3. It does not address the occurrence(s) of a water hammer effect, which can indeed damage the valve. A water hammer in the water supply piping of the valve can create pressures in excess of the rated pressure and should be avoided by all necessary means. This condition may be created from improper fire pump settings, underground construction work, or an improper venting of trapped air in the water supply piping. ENGINEERING SPECIFICATION (50 mm), ½ (65 mm), 3 (80 mm), 4 (00 mm), 6 (50 mm) and 8 (00 mm) Model AGCX Deluge Valve Deluge valve shall be a [ (50 mm)][½ (65 mm)] [3 (80 mm)][4 (00 mm)][6 (50 mm][8 (00 mm] [culus Listed] [Factory Mutual Approved] hydraulically operated, differential latching clapper type valve. Deluge valve construction shall be of lightweight, ductile iron construction with either a screw in stainless steel seat and clapper assembly or drop in bronze seat and clapper assembly. Stainless steel or Bronze seat shall have O-ring seals to resist leakage and corrosion. Clapper AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

facing shall be pressure actuated, providing a limited compression seat for the sealing force between the clapper rubber facing and the valve seat. Deluge valve shall have an external reset knob for resetting the clapper without requiring the removal of the valve face plate. Push-rod chamber design shall consist of a stainless steel piston/ push-rod and spring assembly with diaphragm seal secured to the casting through a push-rod guide constructed of a synthetic engineering plastic to resist corrosion. Casting shall have a bleeder hole located on the pushrod chamber for air/water leakage indication. Trip ratio shall be approximately a 3: force differential. Deluge valve shall be of the straight through design to minimize friction loss. Deluge valve shall be activated by [hydraulic wet-pilot][low pressure, pneumatic dry-pilot][electric] actuation trim. Inlet restriction orifice shall be factory installed into the inlet port of the deluge valve push-rod cover plate and not be a separate part of the deluge valve trim. End connection style to be [ (50 mm)] [½ (65 mm)][76 mm] [3 (80 mm)][4 (00 mm)][65 mm] [6 (50 mm)][8 (00mm)] grooved per ANSI/AWWA C606 or flanged per ASME 6.5 or ISO 7005. Deluge valve shall have a rated working pressure of 50 psi (7, bar) for (50mm), ½ (65mm), 3 (80mm), 76mm and 8 (00mm) valve sizes or 300 psi (0,7 bar) for 4 (00mm), 6 (50mm) and 65mm valve sizes and shall be factory hydrostatic tested at 500 psi (34,5 bar) for (50mm), ½ (65mm), 3 (80mm), 76mm and 8 (00mm) valve sizes or 600 psi (4,4 bar) for 4 (00mm), 6 (50mm) and 65mm valve sizes. Deluge valve to be [ (50 mm)][½ (65 mm)] [3 (80 mm)][4 (00 mm)][6 (50 mm][8 (00 mm)] AG Sprinkler Model AGCX Deluge Valve (Bulletin 59). WET PILOT LINE TRIM Deluge valve wet pilot line trim shall be galvanized and include a ¼ main drain on (50 mm), ½ (65 mm) and 3 (80 mm) valve sizes or a main drain on 4 (00 mm), 6 (50 mm) and 8 (00 mm) valve sizes, alarm line test, water pressure gauges, pushrod chamber supply connections, manual emergency release valve, connection for wet pilot line of detectors, and 4 diameter drip cup assembly. Condensate drain trim shall also be included to prevent water columning above the clapper. The wet pilot line detection piping shall be ½ galvanized pipe and extend from the deluge valve pushrod chamber outlet to the protected area. Maximum wet pilot line length and height shall be in accordance with manufacturer s guidelines (see Fig. ). Wet pilot line shall utilize AG Sprinkler Model F-FTR fixed temperature release pilot line detectors spaced and positioned in accordance with the device listing or in accordance with NFPA 7 as fixed temperature heat detectors. DRY PILOT LINE TRIM Dry pilot line trim to be used in areas: Where ambient temperatures are expected to exceed 50 F (65 C) Subject to freezing Maximum wet pilot line height and/or length are exceeded Deluge valve dry pilot line trim shall be galvanized pipe and include Model AGLP Dry Pilot Line Actuator, a ¼ main drain on (50 mm), ½ (65 mm) and 3 (80 mm) valve sizes or a main drain on 4 (00 mm), 6 (50 mm) and 8 (00 mm) valve sizes, alarm line test, air and water pressure gauges, push-rod chamber supply connections, manual emergency release valve, pressure relief valve, low air pressure switch, connections for dry pilot line of detectors and 4 diameter drip cup assembly. Condensate drain trim shall also be included to prevent water from columning above the clapper. Dry pilot line detection piping shall be ½ galvanized pipe and extend from the deluge valve push-rod chamber outlet to the protected area. Dry pilot line shall utilize AG Sprinkler Model F-FTR fixed temperature release pilot line detectors spaced and positioned in accordance with the device listing or in accordance with NFPA 7 as fixed temperature heat detectors. ELECTRIC ACTUATION TRIM Deluge valve electric trim shall be galvanized pipe and include a normally closed, powered open electric solenoid valve, a ¼ main drain on (50 mm), ½ (65 mm), 3 (80 mm) valve sizes or a main drain on 4 (00 mm), 6 (50 mm) and 8 (00 mm) valve sizes, alarm line test, water pressure gauges, push-rod chamber supply connections, manual emergency release valve, and 4 diameter drip cup assembly. Condensate drain trim shall also be included to prevent water from columning above the clapper. STANDARD SOLENOID VALVE SPECIFICATIONS: Skinner Model 738BN4UNLVN0CC Rated working pressure: 75 psi (, bar) Voltage: 4 VDC Power: 0 Watts Current: 0.4 Amps Holding Enclosure Coil: NEMA 4X Pipe Size: ½ NPT Female Cv Factor: 4.0 -More options available PAG 4 de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

ALTERNATE SOLENOID VALVE SPECIFICATIONS FOR 300psi (0.7bar): Skinner Model 73BN4TNLVN0C3C Rated working pressure: 300 psi (0,7 bar) Voltage: 4 VDC Power: Watts Current: 0.83 Amps Holding Enclosure Coil: NEMA 4X Pipe Size: ½ NPT Female Cv Factor:.8 -more options available. ELECTRO-PNEUMATIC ACTUATION TRIM Deluge valve electro-pneumatic trim to be used in cases where it is advantageous to keep the solenoid dry, such as seawater installations. Deluge valve electro-pneumatic trim shall be galvanized pipe and include a normally closed powered open electric solenoid valve, a Model AGLP Dry Pilot Line Actuator, a ¼ main drain on (50 mm), ½ (65 mm), and 3 (80 mm) valve sizes or a main drain on 4 (00 mm), 6 (50 mm) and 8 (00 mm) valve sizes, alarm line test, air and water pressure gauges, push-rod chamber supply connections, manual emergency release valve, pressure relief valve, low air pressure switch and 4 diameter drip cup assembly. Condensate drain trim shall also be included to prevent water from columning above the clapper. COMBINATION OF ELECTRIC OR DRY PILOT LINE TRIM Deluge valve with combination of electric or pneumatic trim to be used in cases where it is advantageous to maintain a dual actuation with both an electric or a dry pilot trim. Deluge valve electro-pneumatic trim shall be galvanized pipe and include a normally closed powered open electric solenoid valve, a Model AGLP Dry Pilot Line Actuator, a ¼ main drain on (50 mm), ½ (65 mm), and 3 (80 mm) valve sizes or a main drain on 4 (00 mm), 6 (50 mm) and 8 (00 mm) valve sizes, alarm line test, air and water pressure gauges, push-rod chamber supply connections, manual emergency release valve, pressure relief valve, low air pressure switch, connections for dry pilot line of detectors and 4 diameter drip cup assembly. Condensate drain trim shall also be included to prevent water from columning above the clapper. Dry pilot line detection piping shall be ½ galvanized pipe and extend from the deluge valve push-rod chamber outlet to the protected area. Dry pilot line shall utilize AG Sprinkler Model F-FTR fixed temperature release pilot line detectors spaced and positioned in accordance with the device listing or in accordance with NFPA 7 as fixed temperature heat detectors. MODEL AGCX DELUGE VALVE DESCRIPTION. Rated working pressure: Valve & System - 50 psi (7. bar) for (50mm), ½ (65mm), 3 (80mm), 8 (00mm) valve sizes or 300 psi (0,7 bar) for 4 (00mm), 6 (50mm) valve sizes).. Factory tested to a hydrostatic pressure of 500 psi (34,5 bar) for (50mm), ½ (65mm), 3 (80mm), 8 (00mm) valve sizes or 600 psi (4,4 bar) for 4 (00mm), 6 (50mm) valve sizes). (Valve only) 3. Installation position: Vertical 4. End and trim connections: ANSI/AWWA C606 grooved inlet and outlet Threaded openings Per ANSI B. Flange Dimensions Flange Type: AMSE B6.5 Class 50 ISO 7005- PN6 AMSE B6.5 Class 50 ISO 7005- PN6 AMSE B6.5 Class 50 ISO 7005- PN6 Nominal Pipe Size Bolt Circle Diameter Bolt Hole Diameter Flange Outside Diameter Flange Thickness Number of Bolts 4 (00mm) 7 ½ (9mm) ¾ (9mm) 9 (9mm) 5/6 (4mm) 8 4 (00mm) 73/3 (80mm) ¾ (9mm) 9 (9mm) 5/6 (4mm) 8 6 (50mm) 9½ (4mm) 7/8 (mm) (79mm) 5/6 (4mm) 8 6 (50mm) 9 7/6 (40mm) 9/3 (3mm) (79mm) 5/6 (4mm) 8 8 (00mm) ¾ (98mm) 7/8 (mm) 3½ (343mm) (5.4mm) 8 8 (00mm) 5/8 (95mm) 9/3 (3mm) 3½ (343mm) (5.4mm) PAG 5 de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

5. Face to face dimensions: Valve Size: End Connection: End to End: " (50mm), ½" (65mm), 3" (80mm) Groove/ Groove ½" (38mm) 4" (00mm) 6" (50mm) 8" (00mm) 6. Valve Shipping Weight: Groove/ Groove Flange/ Groove Flange/ Flange Groove/ Groove Flange/ Groove Flange/ Flange Groove/ Groove Flange/ Flange 4" (356mm) 6" (406mm) 6" (406mm) 6" (406mm) 9" (483mm) 9" (483mm) 9 3/8 (49mm) ¼" (540mm) Valve Size: End Connection: Weight: " (50mm), ½" (65mm), 3" (80mm) Groove/ Groove 34 lbs (5 kg) 4" (00mm) 6" (50mm) 8" (00mm) 7. Trim Shipping Weight: Groove/ Groove Flange/ Groove Flange/ Flange Groove/ Groove Flange/ Groove Flange/ Flange Groove/ Groove Flange/ Flange 64 lbs (9 kg) 79 lbs (36 kg) 9 lbs (4 kg) 95 lbs (43 kg) lbs (56 kg) 38 lbs (69 kg) 48 lbs (67 kg) 97 lbs (90 kg) Trim Confi guration " (50 mm), ½" (65 mm), 3" (80 mm) 4" (00 mm), 6" (50 mm), 8" (00 mm) Wet Pilot Deluge 3 lbs (4 kg) 37 lbs (7 kg) Dry Pilot Deluge 39 lbs (8 kg) 50 lbs (3 kg) Electric Actuation Deluge 33 lbs (5 kg) 38 lbs (7 kg) Electro-Pneumatic 4 lbs (9Kgr) 53 lbs (4Kgr) Combination of Electric or Pneumatic Deluge. 4 lbs (9Kgr) 53 lbs (4Kgr) 8. Friction loss (Expressed in equivalent length of Schedule 40 pipe, based on Hazen & Williams formula: Valve Size: End Connection: C = 0 C = 00 Cv " (50mm) 4.4 ft (,3 m) 3. ft (,0 m) 0 ½" (65mm) 6.0 ft (,8 m) 4.3 ft (,3 m) 36 3" (80mm).6 ft (3,8 m) 9.0 ft (,7 m) 54 4" (00mm) 4 ft (4,3 m) 0 ft (3,0 m) 469 6" (50mm) 9.4 ft (9,0 m) 0.9 ft (6,4 m) 886 8" (00mm) 53.5 ft (6,3 m) 38. ft (,6 m) 56 PAG 6 de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

0 MODEL AGCX HYDRAULIC FRICTION LOSS GRAPH FLOW RATE (L/SEC) 00 500 INCH (50 MM) -/ INCH (65 MM) & 76M M 3 INCH (80 MM) 4 INCH (00 MM) 6 INCH (50 MM) & 65 MM 8 INCH (00 MM) 0.5 PRESSURE LOSS (PSI) 0. INCH (50 MM) -/ INCH (65 MM) & 76M M 4 INCH (00 MM) 3 INCH (80 MM) 6 INCH (50 MM) & 65 MM 8 INCH (00 MM) 0. 0.05 0.0 PRESSURE LOSS (BAR) FLOW RATE (GPM) Equivalent Length of Pipe 4,4 (,3 m) 6,0 (,8 m),6 (3,8 m) 4,0 (4,3 m) 9,4 (9,0 m) 53,5 (6,3 m) Cv Factor 0 36 54 469 886 56 Valve Size TRIM DESCRIPTIONS The trims for the AG Sprinkler Model AGCX Deluge Valve are arranged for rapid, easy, and compact attachment, and serve as connection points to AG Sprinkler Mechanical Alarms and other devices. The available Model AGCX Deluge Valve trim sets are: Wet Pilot Trim Dry Pilot Trim Electric Actuation Trim Electro-Pneumatic Trim Combination of Electric or Pneumatic Deluge Trim. All trim configurations can be ordered as individual parts, in time-saving segmentally assembled kit forms, or fully assembled to the Model AGCX Deluge Valve (with or without a control valve). The Hydraulic Manual Emergency Station (see Fig. 9) is a standard item of all Deluge Valve trim sets. It consists of an aluminum nameplate mechanically attached to a ball valve. The valve handle in its OFF position is guarded against accidental turning to the ON position (and system discharge) by a nylon cable tie provided with each trim kit. The cable tie is inserted, as shown in Fig. 9, after the system has been restored for operation. The nylon cable tie is designed to allow, in case of an emergency, forceful turning of the valve handle to the ON position. As an alternative to the Hydraulic Manual Emergency Station, the Hydraulic Manual Emergency Pull Box (see Bulletin 506) is also available and can be provided as an option. Model F-FTR fixed temperature pilot line detectors and spacing requirements are described in Bulletin 80. WET PILOT LINE TRIM " (50 mm) /" (65 mm) 3" (80 mm) 4" (00 mm) 6" (50 mm) Wet pilot line operation is the simplest method of Deluge Valve Actuation. The trim is a basic one and its components are included in all other AG Sprinkler Model AGCX Deluge Valve Trims regardless of application. Shown in Figures 4 & 5, it contains components required on all installations, such as a one and one quarter main drain on (50 mm), ½ (65 mm), 3 (80 mm) valve sizes or a two inch main drain on 4 (00 mm), 6 (50 mm) and 8 (00 mm) valve sizes, alarm test, supply and push rod chamber pressure gauges, and push rod chamber connections. The wet pilot line consists of a line of closed detectors (Model F-FTR) located over the area to be protected. This line contains water under pressure and is connected PAG 7 de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08 8" (00 mm)

to the outlet of the push rod chamber of the Deluge Valve. When one of the pilot line detectors actuates, the push rod chamber is vented and the Deluge Valve operates. The Deluge Valve can also be operated manually by opening the ball valve of the Hydraulic Manual Emergency Station (see Fig. 9) or the optional Hydraulic Manual Emergency Pull Box (see AG SPrinkler Bulletin 506). Based on Hazen-Williams Formula With C=0, Using ½ Schedule 40 Pilot Line Pipe The wet pilot line is only a detection system and does not contribute to controlling the fire. Its installation is subject to the following restrictions: a) It is not to be installed in an area subject to freezing. b) It is not to be installed in an area where temperatures in excess of 50 F (65 C) are anticipated. c) NFPA 7 or the authority having jurisdiction should be consulted for spacing and elevation requirements. d) Maximum wet pilot line length and height must comply with data provided in Fig.. Wet Pilot Trim installation on Model AGCX Deluge Valves uses eight tapped openings for trim connections. Each opening and its function are indicated on Fig. 4 or Fig. 5. Using Fig. 4 or Fig. 5 as reference, the recommended trim installation is as follows:. Install ½ nipple (#33, Fig. 4 or #37, Fig. 5) in the tapped opening marked TEST. Note: If interference occurs between the supply gauge and the control valve, the /4 plug (#48, Fig. 4 or #50, Fig. 5) in the opening marked SUPPLY may be swapped with: the /4 nipple (#3, Fig. 4), angle valve (#9, Fig. 4) and gauge (#60, Fig. 4) for the (50mm), -/ (65mm), and 3 (80mm) valve sizes; /4 nipple (#3, Fig. 5), /4 elbow (#3, Fig. 5), /4 nipple (#33, Fig. 5), 3-way valve (#6, Fig. 5) and the gauge (#6, Fig. 5) for the 4 (00mm) and 6 (50mm) valve sizes; /4 nipple (#33, Fig. 5), 3-way valve (#6, Fig. 5) and the gauge (#6, Fig. 5) for the 8 (00mm) valve size, in the trim installed in the opening marked TEST.. Install ½ nipple (#35, Fig. 4 or #34, Fig. 5) in the tapped opening marked ALARM and connect balance of this trim line. 3. Install ¼ plug (#48, Fig. 4 or #50, Fig. 5) in the tapped opening marked SUPPLY. Note: If interference occurs between the supply gauge and the control valve, the /4 plug (#48, Fig. 4 or #50, Fig. 5) in the opening marked SUPPLY may be swapped with: the /4 nipple (#3, Fig. 4), angle valve (#9, Fig. 4) and gauge (#60, Fig. 4) for the (50mm), -/ (65mm) and 3 (80mm) valve sizes; /4 nipple (#3, Fig. 5), /4 elbow (#3, Fig. 5), /4 nipple (#33, Fig. 5), 3-way valve (#6, Fig. 5) and the gauge (#6, Fig. 5) for the 4 (00mm) and 6 (50mm) valve sizes; /4 nipple (#33, Fig. 5), 3-way valve (#6, Fig. 5) and the gauge (#6, Fig. 5) for the 8 (00mm) valve size, in the trim installed in the opening marked TEST. 4. Install ½ nipple (#3, Fig. 4 or #34, Fig. 5) in the tapped opening marked OUT and connect balance of this trim line. 5. Install ¼ inline check valve (#5, Fig. 4 or #4, Fig. 5) in the tapped opening marked IN and connect balance of this trim line. Caution: Over tightening check valve can cause a restriction in fl ow that may prevent the valve from setting up. 6. Install ¼ Nipple (#40, Fig. 4) or nipple (#4, Fig. 5) in the tapped drain opening and connect balance of this trim line. 7. Install ¾ x ¼ reducing coupling (#44, Fig. 4 or #46, Fig. 5) in the lower-most tapped opening at the rear of the Deluge Valve and connect the balance of this trim line. 8. Install ¾ pipe plug (#50, Fig. 4 or #5, Fig. 5) in the upper- most tapped opening at the rear of the Deluge Valve PAG 8 de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

Small AGCX Wet Pilot Line Trim (Refer to Fig. 4) Item No. 3 4 Part No. Galvanized VD050RR0 VD065RR0 VD080RR0 VM050RA300V0 VM065RA300V0 VM080RA300V0 OR80800 OR0000 OR00 OR0400 OR0400 OR04003 5 OR53000 6 OR53004 Description Valve Assembly, " (50mm) - For " Valve Assembly, ½" (65mm) For ½" Assembly Only Valve Assembly, 3" (80mm) - For 3" Butterfly Valve, " For " Butterfly Valve, ½" For ½" Butterfly Valve, 3" For 3" Rigid Coupling, " For " Rigid Coupling, ½" For ½" Rigid Coupling, 3" - For 3" Outlet Spool, " For " Outlet Spool, ½" - For ½" Outlet Spool, 3" For 3" Manual Emergency Station Assembly Valve Caution Station Assembly 7 VMDB05 Ball Drip Valve, ½" 8 9908000 Adhesive Pad 9 OR400 Angle Valve, ¼" 0 OR4006 Angle Valve, ¼" A008794 VRROMM008 3 VRR005 4 VR005 5 VRROMH008 6 A008777 7 AG3055-9-/4 8 0R5680 9 OR56705 0 OR867 Ball Valve, ¼" NPTF x ¼" NPTM Check Valve, ¼" NPTM x ¼" NPTF Check Valve, Horizontal Swing, ½" NPT Check Valve, Horizontal Swing, " NPT Check Valve, Inline Poppet, ¼" Compression Connector, 3/8" ID Tube x ¼" NPT Compression Connector, Elbow 3/8" ID Tube x ¼" NPT Connector, 3/8" ID Tube x ½" NPT Connector, Elbow, 3/8" ID Tube x ¼" NPT Copper Tubing, 3/8" OD x ft. OR695 Deluge Valve Nameplate D0-40DWV Drain Cup, PVC 3 OR0670 Drain Hose Clip QTY. Item No. Part No. Galvanized Description 4 VH3060G00 Elbow, ¼" 5 VH30500G00 Elbow, " 6 OR7444 Elbow, ¼" 7 OR09 Flex Line, ½" 8 VGL008 Globe Valve, ¼" 9 VGL05 Globe Valve, ½" 30 VH3040NPTG Nipple ¼" x ½" 3 3 VH3038NPTG Nipple ¼" x 4" 3 VH3035NPTG Nipple ½" x ½" 5 33 VH3034NPTG Nipple ½" x " 4 34 VH303NPTG Nipple ½" x 3" 35 VH3004NPTG Nipple ½" x Close 4 36 VH304NPTG Nipple ¾" x " 37 OR4363 Nipple " x 3" 38 A00880 Nipple " x Close 39 OR4339 Nipple ¼" x 3" 40 OR4350 Nipple ¼" x 4" 4 OR4385 Nipple ¼" x Close 4 VH30060G00 Pipe Cross, ½" 43 A008796 44 A00500 45 OR480 46 40PVC PVC Tubing, 3/8" ID x 6 ft. Reducer Bushing, ¾" x ¼" Reducer Bushing, ¾" x ½" Reducer Bushing, " Spigot x " NPTF, PVC 47 OR4 Retaining Tie 9 48 VH3000G00 Square Head Plug, ¼" 49 VH3000G00 Square Head Plug, ½" 50 VH300G00 Square Head Plug, ¾" 5 FILY008 Strainer, ¼" 5 OR74400 Street Elbow, ½" 53 VH330G00 Tee, ½" 54 OR6649 Tee, ½" x ¼" x ½" 55 VH33930G00 Tee, ½" x ½" x ¼" 56 VH339G00 Tee, ¾" 57 A008767 Tee, ¾" x ½" x ½" 58 96606630 Tee, ¼" x ¼" x " 59 VH34030G00 Union, ½" 60 V3V008 Valve, 3-way, ¼" 6 MANAA300 Water Pressure Gauge (0-300 psi) QTY. 6 OR0655 Hose Clamp PAG 9 de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

PAG 0 de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

Large AGCX Wet Pilot Line Trim (Refer to Fig. 5) Item No. Part No. Galvanized VD00RR0 Description Valve Assembly, 4" (00mm) -For 4" Assembly Only QT Y. Item No. Part No. Galvanized Description 5 VH30500G00 Elbow, " QTY. 3 4 VD50RR0 VD00RR0 VM00RA300V0 VM50RA300V0 VM00RA300V0 OR6600 OR4400 OR300 OR04004 OR04006 OR04008 5 OR53000 6 OR53004 Valve Assembly, 6" (50mm) -For 6" Assembly Only Valve Assembly, 8" (00mm) -For 8" Assembly Only Butterfly Valve, 4"- For 4" Butterfly Valve, 6" For 6" Butterfly Valve, 8" - For 8" Rigid Coupling, 4" - For 4" Rigid Coupling, 6" - For 6" Rigid Coupling, 8" - For 8" Outlet Spool, 4" - For 4" Outlet Spool, 6" - For 6" Outlet Spool, 8" - For 8" Manual Emergency Station Assembly Valve Caution Station Assembly 7 VMDB05 Ball Drip Valve, ½" 8 9908000 Adhesive Pad 9 9884000 Angle Valve, " 0 A008794 VRROMM008 VRR005 3 VRR005 4 VRROMH008 5 A008797 6 AG3055-9-/4 7 OR5680 8 OR56705 9 OR867 Ball Valve, ¼" NPTF x ¼" NPTM Check Valve, ¼" NPTM x ¼" NPTF Check Valve, Horizontal Swing, ½" NPT Check Valve, Horizontal Swing, " NPT Check Valve, Inline Poppet, ¼" Compression Connector, 3/8" ID Tube x ¼" NPT Compression Connector, Elbow 3/8" ID Tube x ¼" NPT Connector, 3/8" ID Tube x ½" NPT Connector, Elbow, 3/8" ID Tube x ¼" NPT Copper Tubing, 3/8" OD x ft. 0 OR695 Deluge Valve Nameplate D0-40DWV Drain Cup, PVC OR0670 Drain Hose Clip 3 VH3060G00 Elbow, ¼" 6 OR74405 Elbow, " 7 OR09 Flex Line, ½" 8 VGL008 Globe Valve, ¼" 9 VGL05 Globe Valve, ½" 30 VH3040NPTG Nipple ¼" x ½" 3 OR730 Nipple ¼" x ½" 3 VD985430 Nipple ¼" x 3" 33 VH3036NPTG Nipple ¼" x 6" 34 VH3035NPTG Nipple ½" x ½" 9 35 VH3034NPTG Nipple ½" x " 3 36 VH303040NPTG Nipple ½" x 3" 37 VH303050NPTG Nipple ½" x 3½" 38 VH304000NPTG Nipple ¾" x Close 39 A008803 Nipple " x 3½" 40 A008804 Nipple " x 6" 4 A00880 Nipple " x Close 4 OR436 Nipple " x 3½" 43 VH305NPTG Nipple " x Close 44 VH30060G00 Pipe Cross, ½" 45 A008796 46 OR4805 47 OR480 48 40PVC PVC Tubing, 3/8" ID x 6 ft. Reducer Bushing, ¾" x ¼" Reducer Bushing, ¾" x ½" Reducer Bushing, " Spigot x " NPTF, PVC 49 OR4 Retaining Tie 9 50 VH3000G00 Square Head Plug, ¼" 3 5 VH3060G00 Square Head Plug, ½" 5 VH300G00 Square Head Plug, ¾" 53 FILY008 Strainer, ¼" 54 VH330G00 Tee, ½" 55 OR6649 Tee, ½" x ¼" x ½" 56 VH33930G00 Tee, ½" x ½" x ¼" 57 VH3390G00 Tee, ¾" 58 OR066 Tee, ¾" x ½" x ½" 59 OR0667 Tee, " x " x " 60 VH34030G00 Union, ½" 6 V3V008 Valve, 3-way, ¼" 6 MANAA300 Water Pressure Gauge (0-300 psi) 63 OR0655 Hose Clamp 4 VH300G00 Elbow, ¾" PAG de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

PAG de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

Dry Pilot Line Trim Dry pilot line operation is used in areas which are subject to freezing conditions or to obtain installed sprinkler heights and pipe lengths greater than allowed for wet pilot line trim. Dry pilot operation uses a pilot line of closed sprinklers (Model F-FTR) containing air under pressure located in the area to be protected. This pressurized line is connected to a Model AGLP Dry Pilot Line Actuator. The dry pilot line actuator functions very much like a miniature dry pipe valve. In areas where moisture-laden air could cause freezing or other problems in the dry pilot line, the use of a cylinder of dry compressed gas such as nitrogen is suggested. Approved gas handling regulators and connections are then recommended. When one of the closed sprinklers on the dry pilot line actuates, the air pressure is reduced, thus opening the Model AGLP Dry Pilot Line Actuator, which releases the Deluge Valve. NFPA 7 or the Authority Having Jurisdiction should be consulted for spacing and elevation requirements of the pilot line sprinklers. The Dry Pilot Line Trim, shown in Figures 7 and 8, includes gauges to read the air and water pressure, a low air pressure switch, a pressure relief valve, a Model AGLP Dry Pilot Line Actuator, and connections for the dry pilot line of detectors. Dry Pilot Line Trim installation on Model AGCX Deluge Valves uses eight tapped openings for trim connections. Each opening and its function are indicated on Fig. 7 and Fig. 8. Using Fig. 7 and Fig. 8 as reference, the recommended trim installation is as follows:. Install ½ nipple (#39, Fig. 7 or #43, Fig. 8) in tapped opening marked TEST. Note: If interference occurs between the supply gauge and the control valve, the /4 plug (#57, Fig. 7 or #58, Fig. 8) in the opening marked SUPPLY may be swapped with: the /4 nipple (#37, Fig. 7), angle valve (#, Fig. 7) and gauge (#7, Fig. 7) for the (50mm), - / (65mm), 76mm and 3 (80mm) valve sizes; /4 nipple (#37, Fig. 8), /4 elbow (#7, Fig. 8), /4 nipple (#38, Fig. 8), 3-way valve (#69, Fig. 8) and the gauge (#7, Fig. 8) for the 4 (00mm), 65mm and 6 (50mm) valve sizes; /4 nipple (#38, Fig. 8), 3-way valve (#69, Fig. 8) and the gauge (#7, Fig. 8) for the 8 (00mm) valve size, in the trim installed in the opening marked TEST.. Install ½ nipple (#4, Fig. 7 or #39, Fig. 8) in tapped opening marked ALARM and connect balance of this trim line. 3. Install ¼ plug (#57, Fig. 7 or #58, Fig. 8) in tapped opening marked SUPPLY. Note: If interference occurs between the supply gauge and the control valve, the /4 plug (#57, Fig. 7 or #58, Fig. 8) in the opening marked SUPPLY may be swapped with: the /4 nipple (#37, Fig. 7), angle valve (#, Fig. 7) and gauge (#7, Fig. 7) for the (50mm), -/ (65mm), 76mm and 3 (80mm) valve sizes; /4 nipple (#37, Fig. 8), /4 elbow (#7, Fig. 8), /4 nipple (#38, Fig. 8), 3-way valve (#69, Fig. 8) and the gauge (#7, Fig. 8) for the 4 (00mm), 65mm and 6 (50mm) valve sizes; /4 nipple (#38, Fig. 8), 3-way valve (#69, Fig. 8) and the gauge (#7, Fig. 8) for the 8 (00mm) valve size, in the trim installed in the opening marked TEST. 4. Install ½ nipple (#38, Fig. 7 or #39, Fig. 8) in tapped opening marked OUT and connect balance of this trim line. 5. Install ¼ inline check valve (#8, Fig. 7 or #7, Fig. 8) in tapped opening marked IN and connect balance of this trim line. Caution: Over tightening check valve can cause a restriction in flow that may prevent the valve from setting up. 6. Install ¼ Nipple (#47, Fig. 7) or nipple (#48, Fig. 8) in tapped drain opening and connect balance of this trim line. 7. Install ¾ x ¼ reducing bushing (#5, Fig. 7 or #53, Fig. 8) in the lower-most tapped opening at the rear of the Deluge Valve and connect the balance of this trim line. 8. Install ¾ pipe plug (#59, Fig. 7 or #60, Fig. 8) in the upper-most tapped opening at the rear of the Deluge Valve. Connect the air supply to the air inlet side of the Model AGLP Dry Pilot Line Actuator as shown in Fig. 7 or Fig. 8. Table A specifies the air pressure to be used in a dry pilot line. The level of air pressure is adjusted by removing the cap nut on the end of the Relief Valve (#55, Fig. 7 or #56, Fig. 8) and turning the now exposed slotted adjusting screw clockwise to increase pressure or counterclockwise to reduce it. Replace the cap nut after the correct pressure setting has been made at 5 psi above the maximum pilot line pressure required by Table A. An appropriate automatic pressure maintenance device must be used to safeguard against the Deluge Valve tripping due to air pressure leaks in the dry pilot line. See Bulletin 54 for pressure maintenance device information. Install the dry pilot line as required. Wire the low air pressure switch (#5, Fig. 7 or #5, Fig. 8) to an annunciating device or control panel. This low air pressure switch should be set to open at an air pressure which is slightly lower than the Not Less Than values found in Table A. PAG 3 de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

Water Pressure psi (bar) Table A Pneumatic Pressure to be Pumped into Sprinkler System psi (bar) Maximum Not Les Than Not More Than 0 (.4) 0 (.7) 4 (.0) 50 (3.4) (.8) 6 (.) 75 (5.) 3 (.9) 7 (.) 00 (6.9) 5 (.) 9 (.3) 5 (8.6) 6 (.) 0 (.4) 50 (0.3) 7 (.) (.4) 75 (.) 8 (.) (.5) 00 (3.8) 9 (.3) 3 (.6) 5 (5.5) (.4) 5 (.7) 50 (7.) (.5) 6 (.8) 75 (9.) 3 (.6) 7 (.9) 300 (0.7) 4 (.7) 8 (.9) Note: During system set-up, a higher pneumatic pressure may be required in order to properly set the Model AGLP Dry Pilot Line Actuator (AG Sprinkler PART NUMBER ORR3000) (SHOWN IN OPEN POSITION) PAG 4 de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

Model AGLP Dry Pilot Line Actuator Parts List VD393037000 Item No. Part No. Description Qty. Required ORR06936 Lower Housing ORR06935 Upper Housing 3 ORR06905 Seat 4 ORR063 Diaphragm 5 ORR069 Facing Plate Assembly 6 ORR063 Diaphragm Washer 7 ORR06406 Facing Plate Nut 8 ORR0690 Seat O-Ring 9 ORR06305 Bolt 6 0 ORR0690 Compression Spring Maintenance Model AGLP Dry Pilot Line Actuator Refer to Figs. 6 & 4 If water constantly flows through the Model AGLP Dry Pilot Line Actuator and into the drain, there is a leak in the seal of the Actuator s seat.. Close the main valve controlling water supply (Fig. 4) to the Dry Pipe Valve and close off the air/nitrogen supply to the sprinkler system. Close valve A (Fig. 4).. Drop pressure in the system by opening the ¼ angle valve, valve H (Fig. 4), and remove the Actuator from the system. 3. Remove all six bolts (#9, Fig. 6) holding the Actuator together. Clean or replace the facing plate assembly (#5, Fig. 6), seat (#3, Fig. 6) and seat o-ring (#8, Fig. 6). 4. Reassemble the Actuator, using a torque of 8 ft-lbs on the facing plate nut (#7, Fig. 6) and ft-lbs on the six bolts (#9, Fig. 6). Use a cross-tightening pattern. Reinstall the Actuator. Set up the Model AGCX Deluge Valve as per the section Resetting Model AGCX Deluge Valve System. PAG 5 de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

Small AGCX Dry Pilot Line Trim (Refer to Fig. 7) Item No. 3 4 5 Part No. Galvanized VD050RR0 VD065RR0 VD080RR0 VM050RA300V0 VM065RA300V0 VM080RA300V0 OR080800 OR0000 OR00 OR0400 OR0400 9004003 SY340404 Description Valve Assembly, " (50mm) For " Valve Assembly, ½"(65mm) For ½" Valve Assembly, 3" (80mm) For 3" Butterfly Valve, " For " Butterfly Valve, ½" For ½" Butterfly Valve, 3" For 3" Rigid Coupling, " For " Rigid Coupling, ½" For ½" Rigid Coupling, 3" - For 3" Outlet Spool, " For " Assembly Only Outlet Spool, ½" - For ½" Outlet Spool, 3" For 3" Assembly Only Pressure Switch (EPS40-) (UL/FM) QTY. SY340404 Pressure Switch (EPSA40-) (ULC) 6 VD393037000 Model AGLP Pilot Line Actuator 7 OR53000 Manual Emergency Station Assembly 8 OR53004 Valve Caution Station Assembly 9 VMDB05 Ball Drip Valve, ½" 0 OR8000 Adhesive Pad OR400 Angle Valve, ¼" OR4006 Angle Valve, ¼" 3 VRROMH008 Ball Valve, ¼" NPTF x ¼" NPTM 4 OR4009 Ball Valve, ½" 5 VRROMM008 6 VRRO05 7 VRRO05 Check Valve, ¼" NPTM x ¼" NPTF Check Valve, Horizontal Swing, ½" NPT Check Valve, Horizontal Swing, " NPT 8 VRROMH008 Check Valve, Inline Poppet, ¼" 9 A008797 0 Ag3055-9-/4 A0088 A008809 3 OR56704 Compression Connector, 3/8" ID Tube x ¼" NPT Compression Connector, Elbow 3/8" ID Tube x ¼"NPT Connector, 3/8" ID Tube x ½" NPT Connector, Elbow, 3/8" ID Tube x ¼" NPT Connector, Elbow, 3/8" ID Tube x ½" NPT 4 A008808 Copper Tubing, 3/8" OD x ft. 5 OR695 Deluge Valve Nameplate 6 D0-40DW Drain Cup, PVC 7 OR0670 Drain Hose Clip 8 VH3060G00 Elbow, ¼" Item No. Part No. Galvanized Description QTY. 9 VH3000NPTG Elbow, ½" 30 VH30600G00 Elbow, " 3 OR7444 Elbow, ¼" 3 OR09 Flex Line, ½" 33 VGL008 Globe Valve, ¼" 34 VGL05 Globe Valve, ½" 35 VH3040NPTG Nipple ¼" x ½" 3 36 VD985430 Nipple ¼" x 3" 37 VH3038NPTG Nipple ¼" x 4" 38 VH3035NPTG Nipple ½" x ½" 39 VH3034NPTG Nipple ½" x " 4 40 VH303NPTG Nipple ½" x 3" 4 VH3004NPTG Nipple ½" x Close 4 VH304NPTG Nipple ¾" x " 4 43 OR4363 Nipple " x 3" 44 A00880 Nipple " x Close 45 OR4339 Nipple ¼" x 3" 46 OR4350 Nipple ¼" x 4" 47 OR4385 Nipple ¼" x Close 48 VH30060G00 Pipe Cross, ½" 49 A008796 50 A00500 5 OR48000 5 OR4805 53 40PVC 54 OR4805 55 A008638 PVC Tubing, 3/8" ID x 6 ft. Reducer Bushing, ¾" x ¼" Reducer Bushing, ½" x ¼" Reducer Bushing, ¾" x ¼" Reducer Bushing, ¾" x ½" Reducer Bushing, " Spigot x " NPTF, PVC Relief Valve, ½" NPT, 33 psi 56 OR4 Retaining Tie 9 57 VH3000G00 Square Head Plug, ¼" 3 58 VH3000G00 Square Head Plug, ½" 59 VH300G00 Square Head Plug, ¾" 60 FILY008 Strainer, ¼" 6 OR74400 Street Elbow, ½" 6 VH33030G00 Tee, ½" 3 63 OR6649 Tee, ½" x ¼" x ½" 64 VH33930G00 Tee, ½" x ½" x ¼" 65 VH339G00 Tee, ¾" 66 A008767 Tee, ¾" x ½" x ½" 67 OR06630 Tee, ¼" x ¼" x " 68 VH34030G00 Union, ½" 3 69 V3V008 Valve, 3-way, ¼" 70 MANAA80 Air Pressure Gauge (0-80 psi) 7 MANAA300 Water Pressure Gauge (0-300 psi) 7 OR0655 Hose Clamp 3 PAG 6 de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

PAG 7 de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

Large AGCX Dry Pilot Line Trim (Refer to Fig. 8) Item No. Part No. Galvanized Description QTY. 7 VH3060G00 Elbow, ¼" 8 VH3000NPTG Elbow, /" VD00RR0 VD50RR0 Valve Assembly, 4" (00mm) -For 4" Valve Assembly, 6" (50mm) -For 6" 9 A004990 Elbow, ¾" 30 VH30500G00 Elbow, " 3 OR74405 Elbow, " 3 OR09 Flex Line, ½" VD00RR0 Valve Assembly, 8" (00mm) -For 8" 33 VGL008 Globe Valve, ¼" 34 VGL05 Globe Valve, ½" 3 4 VM00RA300V0 VM50RA300V0 VM00RA300V0 OR6600 OR4400 OR300 OR04004 OR04006 OR04008 Butterfly Valve, 4"- For 4" Butterfly Valve, 6" For 6" Butterfly Valve, 8" - For 8" Rigid Coupling, 4" - For 4" Rigid Coupling, 6" - For 6" Rigid Coupling, 8" - For 8" Outlet Spool, 4" - For 4" Assembly Only Outlet Spool, 6" - For 6" Assembly Only Outlet Spool, 8" - For 8" Assembly Only Pressure Switch SY340404 (EPS40-) (UL/FM) 5 Pressure Switch SY340404 (EPSA40-) (ULC) 6 VD393037000 Model AGLP Pilot Line Actuator 7 OR53000 Manual Emergency Station Assembly 8 OR53004 Valve Caution Station Assembly 9 VMDB05 Ball Drip Valve, ½" 0 OR8000 Adhesive Pad OR4000 Angle Valve, " A008794 Ball Valve, ¼" NPTF x ¼" NPTM 3 OR4009 Ball Valve, ½ 4 VRROMM008 5 VRRO05 6 VRRO05 Check Valve, ¼" NPTM x ¼" NPTF Check Valve, Horizontal Swing, ½" NPT Check Valve, Horizontal Swing, " NPT 7 VRROMH008 Check Valve, Inline Poppet, ¼" 8 Ag3055-9-/4 9 A008809 Compression Connector, 3/8" ID Tube x ¼" NPT Compression Connector, Elbow 3/8" ID Tube x ¼" NPT 0 A0088 Connector, 3/8" ID Tube x ½" NPT Ag3055-9-/4 9056704 3 A008808 Connector, Elbow, 3/8" ID Tube x ¼" NPT Connector, Elbow, 3/8 ID Tube x ½ NPT Copper Tubing, 3/8" OD x ft. 35 VH3040NPTG Nipple ¼" x ½" 36 OR730 Nipple ¼" x ½" 37 VD985430 Nipple ¼" x 3" 38 VH3036NPTG Nipple ¼" x 6" 39 VH3035NPTG Nipple ½" x ½" 5 40 VH3034NPTG Nipple ½" x " 3 4 VH3033NPTG Nipple ½ x ½ 4 VH303NPTG Nipple ½" x 3" 43 VH303NPTG Nipple ½" x 3½" 44 A00497 Nipple ¾" x Close 45 A008803 Nipple " x 3½" 46 A008804 Nipple " x 6" 47 A00880 Nipple " x Close 48 OR436 Nipple " x 3½" 49 OR4338 Nipple " x Close 50 VH30060G00 Pipe Cross, ½" 5 A008796 PVC Tubing, 3/8" ID x 6 ft. 5 OR48000 Reducer Bushing, ½ x ¼ 53 OR4805 Reducer Bushing, ¾" x ¼" 54 OR480 Reducer Bushing, ¾" x ½" 55 40PVC Reducer Bushing, " Spigot x " NPTF, PVC 56 A008638 Relief Valve, ½ NPT, 33 psi 57 OR4 Retaining Tie 9 58 VH3000G00 Square Head Plug, ¼" 4 59 VH3000G00 Square Head Plug, ½" 3 60 VH300G00 Square Head Plug, ¾" 6 FILY008 Strainer, ¼" 6 VH33930G00 Tee, ½" 3 63 OR6649 Tee, ½" x ¼" x ½" 64 VH33930G00 Tee, ½" x ½" x ¼" 65 VH339G00 Tee, ¾" 66 A008767 Tee, ¾" x ½" x ½" 67 OR0667 Tee, " x " x " 68 VH34030G00 Union, ½" 3 69 V3V008 Valve, 3-way, ¼" 3 70 MANAA80 Air Pressure Gauge (0-80 psi) 7 MANAA300 Water Pressure Gauge (0-300 psi) 7 OR0655 Hose Clamp 3 4 OR695 Deluge Valve Nameplate 5 D0-40DWV Drain Cup, PVC 6 OR0670 Drain Hose Clip PAG 8 de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

PAG de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

Electric Actuation Trim Electric Actuation trim (see Figures 0 and ) combines a normally closed/powered-open solenoid valve with the Wet Pilot Trim for releasing the Deluge Valve. The solenoid valve used in the assembly is available in both a 75 psi (, bar) or 300 psi (0,7 bar) rating. Details on the electrical portion of this trim can be found in AG Sprinkler Bulletin 700, which describes Deluge and Preaction Systems. Caution: Repairs or disassembly of the solenoid valve should only be done by a trained technician. An improperly repaired or partially assembled solenoid valve could result in failure of the valve to operate. Electric Actuation Trim installation on Model AGCX Deluge Valves uses eight tapped openings for trim connections. Each opening and its function are indicated on Fig. 0 or Fig.. Using Fig. 0 or Fig. as reference, the recommended trim installation is as follows:. Install ½ nipple (#35, Fig. 0 or #39, Fig. ) in tapped opening marked TEST. Note: If interference occurs between the supply gauge and the control valve, the /4 plug (#50, Fig. 0 or #5, Fig. ) in the opening marked SUPPLY may be swapped with: the /4 nipple (#3, Fig. 0), angle valve (#0, Fig. 0) and gauge (#63, Fig. 0) for the (50mm), -/ (65mm), 76mm and 3 (80mm) valve sizes; /4 nipple (#34, Fig. ), /4 elbow (#5, Fig. ), /4 nipple (#35, Fig. ), 3-way valve (#63, Fig. ) and the gauge (#64, Fig. ) for the 4 (00mm), 65mm and 6 (50mm) valve sizes; /4 nipple (#35, Fig. ), 3-way valve (#63, Fig. ) and the gauge (#64, Fig. ) for the 8 (00mm) valve size, in the trim installed in the opening marked TEST.. Install ½ nipple (#37, Fig. 0 or #36, Fig. ) in tapped opening marked ALARM and connect balance of this trim line. 3. Install ¼ plug (#50, Fig. 0 or #5, Fig. ) in tapped opening marked SUPPLY. Note: If interference occurs between the supply gauge and the control valve, the /4 plug (#50, Fig. 0 or #5, Fig. ) in the,opening marked SUPPLY may be swapped with: the /4 nipple (#3, Fig. 0), angle valve (#0, Fig. 0) and gauge (#63, Fig. 0) for the (50mm), -/ (65mm), 76mm and 3 (80mm) valve sizes; /4 nipple (#34, Fig. ), /4 elbow (#5, Fig. ), /4 nipple (#35, Fig. ), 3-way valve (#63, Fig. ) and the gauge (#64, Fig. ) for the 4 (00mm), 65mm and 6 (50mm) valve sizes; /4 nipple (#35, Fig. ), 3-way valve (#63, Fig. ) and the gauge (#64, Fig. ) for the 8 (00mm) valve size, in the trim installed in the opening marked TEST. 4. Install ½ nipple (#34, Fig. 0 or #36, Fig. ) in tapped opening marked OUT and connect balance of this trim line. 5. Install ¼ inline check valve (#6, Fig. 0 or #5, Fig. ) in tapped opening marked IN and connect balance of this trim line. Supply line must be connected to the inlet mof the control valve for each Deluge Valve as shown. Caution: Over tightening check valve can cause a restriction in flow that may prevent the valve from setting up. 6. Install ¼ Nipple (#4, Fig. 0) or nipple (#44, Fig. ) in tapped drain opening and connect balance of this trim line. 7. Install ¾ x ¼ reducing bushing (#46, Fig. 0 or #48, Fig. ) in the lower-most tapped opening at the rear of the Deluge Valve and connect the balance of this trim line. 8. Install ¾ pipe plug (#5, Fig. 0 or #54, Fig. ) in the upper-most tapped opening at the rear of the Deluge Valve. Maintenance AG Sprinkler Deluge Valves and associated equipment shall periodically be given a thorough inspection and test. NFPA 5 provides minimum requirements for inspection, testing and maintenance. The Deluge Valve should be tested, operated, cleaned, and inspected at least annually and parts replaced as required. PAG 0 de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

Small AGCX Electric Actuation Trim (Refer to Fig. 0) Item No. Part No. Galvanized Description QTY. Item No. Part No. Galvanized Description QTY. VD050RR0 VD065RR0 Valve Assembly, " (50mm) For " Assembly Only Valve Assembly, ½"(65mm) For ½" 3 OR695 Deluge Valve Nameplate 4 D0-40CWV Drain Cup, PVC 5 OR0670 Drain Hose Clip 6 VH3060G00 Elbow, ¼" 7 VH30500G00 Elbow, " VD080RR0 Valve Assembly, 3" (80mm) For 3" Assembly Only 8 OR7444 Elbow, ¼" 9 OR09 Flex Line, ½" VM050RA300V0 VM065RA300V0 VM080RA300V0 Butterfly Valve, " For " Butterfly Valve, ½" For ½" Butterfly Valve, 3" For 3" 30 VGL008 Globe Valve, ¼" 3 VGL05 Globe Valve, ½" 3 VH3040NPTG Nipple ¼" x ½" 3 33 VH3038NPTG Nipple ¼" x 4" 34 VH3035NPTG Nipple ½" x ½" 6 3 OR80800 OR0000 OR00 Rigid Coupling, " For " Rigid Coupling, ½" For ½" Rigid Coupling, 3" - For 3" 35 VH3034NPTG Nipple ½" x " 4 36 VH3004NPTG Nipple ½" x Close 37 VH304NPTG Nipple ¾" x " 4 38 OR4363 Nipple " x 3" 39 A00880 Nipple " x Close 4 OR0400 OR0400 Outlet Spool, " For " Outlet Spool, ½" - For ½" 40 OR4339 Nipple ¼" x 3" 4 OR4350 Nipple ¼" x 4" 4 OR4385 Nipple ¼" x Close 5 OR04003 IOM7 OR0000 6 OR53000 7 OR53004 Outlet Spool, 3" For 3" Solenoid Valve, 75 psi Rated Solenoid Valve, 300 psi Rated Manual Emergency Station Assembly Valve Caution Station Assembly 43 VH30060G00 Pipe Cross, ½" 44 A0088796 PVC Tubing, 3/8" ID x 6 ft. 45 OR4805 Reducer Bushing, ¾" x ¼" 46 OR4805 Reducer Bushing, ¾" x ¼" 47 OR480 Reducer Bushing, ¾" x ½" 48 40PVC Reducer Bushing, " Spigot x " NPTF, PVC 49 OR4 Retaining Tie 9 8 VMDB05 Ball Drip Valve, ½" 9 OR8000 Adhesive Pad 0 OR400 Angle Valve, ¼" OR4006 Angle Valve, ¼" A008794 Ball Valve, ¼" NPTF x ¼" NPTM 3 VRROMM008 4 VRRO05 5 VRRO05 6 VRROMH008 7 A008797 8 AG3055-9-/4 9 A0088 Check Valve, ¼" NPTM x ¼" NPTF Check Valve, Horizontal Swing, ½" NPT Check Valve, Horizontal Swing, " NPT Check Valve, Inline Poppet, ¼" Compression Connector, 3/8" ID Tube x ¼" NPT Compression Connector, Elbow 3/8" ID Tube x ¼"NPT Connector, 3/8" ID Tube x ½" NPT 0 A008809 Connector, Elbow, 3/8" ID Tube x ¼" NPT OR56704 Connector, Elbow, " ID Tube x ½" NPT A008808 Copper Tubing, " OD x 50 VH3000G00 Square Head Plug, ¼" 5 VH3000G00 Square Head Plug, ½" 5 VH300G00 Square Head Plug, ¾" 53 FILY008 Strainer, ¼" 54 OR74400 Street Elbow, ½" 55 VH33030G00 Tee, ½" 56 9876649 Tee, ½" x ¼" x ½" 57 VH33930G00 Tee, ½" x ½" x ¼" 58 VH339G00 Tee, ¾" 59 A008767 Tee, ¾" x ½" x ½" 60 OR06630 Tee, ¼" x ¼" x " 6 VH34030G00 Union, ½" 6 V3V008 Valve, 3-way, ¼" 63 MANAA300 Water Pressure Gauge (0-300 psi) 64 OR0655 Hose Clamp 3 PAG de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

PAG de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08

Large AGCX Electric Actuation Trim (Refer to Fig.) Item No. Part No. Galvanized Description QTY. Item No. Part No. Galvanized Description QTY. VD00RR0 Valve Assembly, 4" (00mm) -For 4" Assembly Only 5 VH3060G00 Elbow, ¼" 6 A004990 Elbow, ¾" VD50RR0 Valve Assembly, 6" (50mm) -For 6" Assembly Only 7 VH30500G00 Elbow, " 8 OR74405 Elbow, " 3 4 5 VD00RR0 VM00RA300V0 VM50RA300V0 VM00RA300V0 OR6600 OR4400 OR300 OR04004 OR04006 OR04008 IOM7 OR000 6 A008806 7 A008807 Valve Assembly, 8" (00mm) -For 8" Assembly Only Butterfly Valve, 4"- For 4" Butterfly Valve, 6" For 6" Butterfly Valve, 8" - For 8" Rigid Coupling, 4" - For 4" Rigid Coupling, 6" - For 6" Rigid Coupling, 8" - For 8" Outlet Spool, 4" - For 4" Outlet Spool, 6" - For 6" Outlet Spool, 8" - For 8" Solenoid Valve, 75 psi Rated Solenoid Valve, 300 psi Rated Manual Emergency Station Assembly Valve Caution Station Assembly 8 VMDB05 Ball Drip Valve, ½" 9 OR8000 Adhesive Pad 0 OR4000 Angle Valve, " A008794 VRROMM008 3 VRRO05 4 VRRO05 5 VRROMH008 6 A008797 7 AG3055-9-/4 8 A0088 9 A008809 0 A008809 A008808 Ball Valve, ¼" NPTF x ¼" NPTM Check Valve, ¼" NPTM x ¼" NPTF Check Valve, Horizontal Swing, ½" NPT Check Valve, Horizontal Swing, " NPT Check Valve, Inline Poppet, ¼" Compression Connector, 3/8" ID Tube x ¼" NPT Compression Connector, Elbow 3/8" ID Tube x ¼" NPT Connector, 3/8" ID Tube x ½" NPT Connector, Elbow, 3/8" ID Tube x ¼" NPT Connector, Elbow, 3/8" ID Tube x ¼" NPT Copper Tubing, 3/8" OD x ft. OR695 Deluge Valve Nameplate 3 D0-40DWV Drain Cup, PVC 4 OR0670 Drain Hose Clip 9 OR09 Flex Line, ½" 30 VGL008 Globe Valve, ¼" 3 VGL05 Globe Valve, ½" 3 VH3040NPTG Nipple ¼" x ½" 33 OR730 Nipple ¼" x ½" 34 VD985430 Nipple ¼" x 3" 35 OR437 Nipple ¼" x 6" 36 VH3035NPTG Nipple ½" x ½" 0 37 VH3034NPTG Nipple ½" x " 3 38 VH303NPTG Nipple ½" x 3" 39 VH303NPTG Nipple ½" x 3½" 40 A00497 Nipple ¾" x Close 4 A008803 Nipple " x 3½" 4 A008804 Nipple " x 6" 43 A00880 Nipple " x Close 44 OR436 Nipple " x 3½" 45 OR4338 Nipple " x Close 46 VH30060G00 Pipe Cross, ½" 47 A008796 48 OR4805 49 OR480 50 40PVC PVC Tubing, 3/8" ID x 6 ft. Reducer Bushing, ¾" x ¼" Reducer Bushing, ¾" x ½" Reducer Bushing, " Spigot x " NPTF, PVC 5 OR4 Retaining Tie 9 5 VH3000G00 Square Head Plug, ¼" 3 53 VH3000G00 Square Head Plug, ½" 54 VH300G00 Square Head Plug, ¾" 55 FILY008 Strainer, ¼" 56 VH33030G00 Tee, ½" 57 OR6649 Tee, ½" x ¼" x ½" 58 VH33930G00 Tee, ½" x ½" x ¼" 59 VH339G00 Tee, ¾" 60 A008767 Tee, ¾" x ½" x ½" 6 OR0667 Tee, " x " x " 6 VH34030G00 Union, ½" 63 V3V008 Valve, 3-way, ¼" 64 MANAA300 Water Pressure Gauge (0-300 psi) 65 OR0655 Hose Clamp 3 PAG 3 de 50 AGCX Bulletin 59 C/Alfoz de Bricia nº4 P.l. Villalonquéjar 0900 Burgos (Spain) Tlfno: +34 947 8 08