Series ISA. Air Catch Sensor. For Detection of Work Presence

Similar documents
Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation

Non-Contact Sensor for Workpiece Placement Verification

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation

2-Color Display High-Precision Digital Pressure Switch

ZSE30A(F) ISE30A. 105 to 105 kpa 10 to 105 kpa to 1.05 MPa. (0 to 50 C) ±0.2% F.S. ±1 digit. NPN/PNP open collector

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

Compact Proportional Solenoid Valve

Vacuum Equipment. Application. Series

Vacuum Switch Diaphragm Style. Specifications

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

Glossary of Terms/Technical Information

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

Vacuum pump system type

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

MULTISTAGE MICRO EJECTORS

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter

2-Color Display High-Precision Digital Pressure Switch

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Vacuum Ejector with Solid State Timer

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Cylindrical Inductive Proximity Sensor GX-M SERIES

2-Color Display Digital Pressure Switch

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

2-Color Display Digital Pressure Switch

Model Pressure range ON/OFF output Linear output

2-Color Display Digital Pressure Switch

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

GH-5S. 5.6 times approx. Tightening torque 0.78N m or less. Disconnection Alarm Indicator

Series 10-ZSE40A(F)/10-ISE40A

Series PSE560 Pressure Sensor For General Fluids... 90

Series PSE100. Controller PSE10. How to Order. Controller Specifications Option. Output specifications. Mounting

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

2-Color Display Digital Flow Switch

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

LCD Readout Digital Pressure Switch

Digital display Pressure range ON/OFF output Linear output Model

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

Digital Gap Checker. ISA3 series

Digital Flow Switch for Deionized Water and Chemicals Body and sensor New PFA Tube Super PFA

Ionizer (Nozzle type) Series IZN10

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Low Differential Pressure Sensor ±1% F.S.

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Related vacuum products

Air Catch Sensor to 0.5mm. Series ISA2. Air Catch Sensor for Work Piece Detection. Detection distance. Repetition accuracy

Electro-Pneumatic Regulator / Electronic Vacuum Regulator

Series VQ Port Solenoid Valve

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Vacuum Module. Series ZX. Ejector System/Vacuum Pump System

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electronic Pressure Switch EDS 3000

Series ZM Applications

Three types of flow range. 0.4 to 4 L/min (PF2D504) 1.8 to 20 L/min (PF2D520) 4.0 to 40 L/min (PF2D540) Swept flow characteristics (reference)

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Rectangular-shaped Inductive Proximity Sensor.

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

Digital Flow Switch (Sensor Part) Operation Manual

Pilot Operated 2 Port Solenoid Valve for Dry Air

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

High-frequency AC Method. panasonic-electric-works.net/sunx

3 Port Solenoid Valve

Remote Type Pressure Sensors Pressure Sensor Controllers

Thread type to 0.8 MPa to 0.8 MPa. Note) Air operated type is model IR2120 only. Note) Air operated type is model IR3120 only.

Digital Flow Switch. How to Order PF2D C. Port size: (inch) PF2D504 PF2D520 PF2D540

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Transmitters: Relay Valve VR4151/4152

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less.

2-colour Display High Precision Digital Pressure Switch

Model Pressure range ON/OFF output Linear output

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil

HS6B Series Subminiature Interlock Switch

GXL SERIES. High performance in micro-size design. Micro-size Inductive Proximity Sensor PROXIMITY SENSORS INDUCTIVE. Wide model variety

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

SOLENOID VALVES, SERIES

2 Port Solenoid Valve For Dust Collector

DPS280 / DVS280 Series

Digital Gap Checker. ISA3 series

High Pressure Coolant Valve

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

SA1W: Water Detection Sensors

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

80g. 10.5mm. Width: Weight: Complex Vacuum Generator with Lightweight, Compact Body and High Vacuum Cycle Vacuum Generator VX Series

Transcription:

ED Bar graph for easy calibration The ED bar graph indicator in conjunction with the adjustment knob for the variable orifice allows for easy and correct calibrations. Over range (Red) Correct range (Green) Under range (Green) Adjustment knob for variable orifice Air Catch Sensor Series Reliable detection of a µm gap The operation of the Air-Catch Sensor is stable during supply pressure fluctuations due to the internal air bridge circuit and solid state sensors. For Detection of Work Presence Up to Air-Catch Sensors can be manifold mounted for centralized wiring and piping. Mounting orientation Due to the use of a pressure sensor, stable detection is guaranteed regardless of mounting orientation. Wide detection range Applicable to to 00 µm Enclosure IP Dust proof and drip proof Due to the construction of the sensor, fluctuations in the supply pressure do not influence operations. Non contact style sensor for applications requiring confirmation of work present for machining operations..8-1

Air Catch Sensor How to Order Individual/Centralized Wiring 01 Output specifications 11 1 NPN open collector 1 output PNP open collector 1 output Example 1) NPN output, stations, centralized wiring with terminal block box on left side, with bracket and gauge. 11--01BG Example ) PNP output, single unit individual wiring, with gauge. 1-1-01G Accessories (Optional) Bracket -1-A G--01 DIN rail --1 to 7 Station 1 to Option Applicable to DIN rail B With bracket G With gauge Order DIN rail separately. Wiring specifications Individual wiring (Without terminal block box) Centralized wiring (With terminal block box on left side) Centralized wiring R (With terminal block box on right side) PSE ZSE ISE ZSE ISE ZSE ISE ZSE ISE GS PS ZSE1 ISE1 ZSE ISE ZSP IS ZSM PF IF /G--01 Bracket /-1-A DIN rail/--1 to 7 Material: SPC (Nickel plated) Material: Aluminum hex. q w e r t -ø. 1 0 7. ø0 9 R 1 /8 8 1. 1.. 7 Description No. q w e r t Description Cover Front rim Retaining rim Cross recessed round head screw Stub Material Glass Stainless steel Stainless steel Stainless steel Brass Part no. includes M X 8 tapping screws ( pcs.) Part No. --1 -- -- -- -- -- --7 10 80 1 Applicable model -1 -/ -1R -/ -R -/ -R -/ -R -/ -R - R.8-

Specifications Fluid Operating pressure range Recommended pressure range Detection zone Repeatability including temperature characteristics Hysteresis Detection nozzle size Indicator light Power supply voltage Current consumption Output Flow consumption 11 1 Operating temperature range Operating humidity range Noise resistance Voltage resistance Insulation resistance Vibration resistance Impact resistance Cable Weight Port size Enclosure Supply pressure Dry air (Filtered through a µm filter) 0.0 to 0.MPa 0.1 to 0.MPa to 00 µm ±µm (for 0 to C on the basis of C) ess than µm (Detection distance to 10 µm) ø1.0 standard (Refer to p..8-7 when nozzle size is changed) Operation indicator light (lighting under ON condition) level indicator light 1 to V DC (Ripple less than ±%) ess than 0 ma (Output ON, ED ON) NPN open collector less than 0V 80mA PNP open collector less than 80mA 0 to C (No condensation) to 8% RH 00 Vp-p Pulse width 1µS, Standing 1ns pulse 00V AC 0/Hz for one minute between external terminals and case M or more (at 00VDC megameter) between external terminals and case to 00Hz vibration width 1.mm or 9.8m/s to X, Y, Z directions hours for each direction 980 m/s X, Y, Z direction, times for each direction Oil-proof chloroethylene cable (ø., 0.mm, m) 0g (Including gauge, m lead wire) Rc 1/8 IP (Dust proof and drip proof) 1l/min at 0. MPa 1l/min at 0.1 MPa l/min at 0.0 MPa Operation Principles Method of Calibration S1 S P1 Sensor P S1, S: Fixed orifice S: Variable orifice (Set via adjustment knob) S: Detection nozzle S The bridge circuit is constructed as shown in the diagram. Position the work piece in front of the nozzle (S). With a gap gauge adjust the distance between work piece and the nozzle. Remove the gauge and balance the bridge circuit (P1 = P) by adjusting the variable orifice (S) via the adjustment knob. By moving the work piece away from the nozzle (S) a pressure differential (P1 >_ P) is created. As soon as the work piece is moved within the detection range of the Air- Catch Sensor the back pressure P increases. If P is equal or greater than P1, the switch output is ON. As soon as the work piece is outside of the detection zone the switch output is OFF. S The Air-Catch Sensor is adjusted using the ED bar graph and the adjustment knob. Gap too big BEST POSITION ED lever meter + Red 1 Red Green 1 Red is on: Output OFF Green is on: Output ON Gap too small Green a Place the gap gauge on the detection nozzle for precise adjustment. s Confirm applied air pressure. If the variable orifice is closed (turn the adjustment knob counterclockwise), all ED's are off. d When opening the variable orifice (turn the adjustment knob clockwise) the ED's will light up in the following order: Red 1, Red, Green 1, Green f When the ED Green 1 is on, the output is energized. This should conclude the calibration. g Confirm calibration setting by removing the gap gauge from the nozzle. The ED Green 1 should go off. Place the gap gauge on to the detection nozzle again, the Green 1 ED should light up again. h Secure the setting of the adjustment knob with the spanner nut..8-

Air Catch Sensor Internal Circuit/Wiring The lead wire colors indicated inside "( )" are old colors prior to compliance with the IEC standard. NPN Open Collector (Sinking) Main circuit MAX.80mA PNP Open Collector (Sourcing) Main circuit + 1 to V DC + 1 to V DC Installation qdo not allow water, cutting oil, etc. to flow back from the detection nozzle to the switch body. Always mount switch body higher than detection nozzle if possible. Brown DC (+) Black Blue DC ( ) Piping qpiping materials Do not mount any equipment or fittings between the switch body and the detection nozzle in order to avoid leaks and pressure drops. Do not use one-touch fittings in applications where these fittings might be exposed to liquid being sprayed onto them. q Supply air Be careful not to allow any foreign materials into the supply of the Air Catch Sensor. Contamination of the sensor will decrease the sensor s accuracy. Especially important when measuring small bore orifices. Use dry and filtered (µm) supply air. woperating pressure Do not exceed the max. operating pressure of 0. MPa. Damage to the solid state pressure sensor may occur. oad Brown DC (+) Black Blue DC ( ) MAX.80mA oad Supply Pressure side Precautions Centralized Wiring Style Relation between terminal block wiring in terminal box and switch is shown below. 1 GND VCC NC qif the Air Catch Sensor is mounted in an enclosure, make sure that the exhaust port is open to atmospheric pressure to avoid malfunction due to possible pressure build-up inside the enclosure. wconnect the tubing via the M fittings to the Air Catch Sensor. Place the tubing in such a way that no water, oil, etc. can enter the sensor. The Air Catch Sensor is rated IP. However in order to achieve this rating the gauge has to be removed from the sensor screw a fitting into the gauge port and run tubing to the gauge. When remove mounting the gauge keep the tubing as short as possible otherwise the response time will increase. qafter removing the mounting screws (M X 8) pull the switch body off vertically. If the switch body is pulled off in an angle the connector pins may be bent. wwhen mounting the switch body onto the base, be careful that the body is lowered vertically onto the base and the connector pins are not bent. Tighten the mounting screws equally (M X 8). Note) Do not forget to insert the seals prior to mounting the body onto the base. (Tightening torque is 0. Nm.) q w e r t y Be sure to read before handling. Refer to p.0- and 0-7 for Safety Instruction and common precaution of the products mentioned in this catalog, and refer to p..0-7 to.0-9 for precautions on every series. Environment Maintenance Switch ass y R side PSE ZSE ISE ZSE ISE ZSE ISE ZSE ISE GS PS ZSE1 ISE1 ZSE ISE ZSP IS ZSM PF IF O ring Gasket Base.8-

Dimensions/Centralized Wiring (Terminal Block Box Style) Unit With bracket Manifold level indicator 0 7 0 Terminal block box (9.) SUP. DIN rail center SUP level indicator 0 1 0 Terminal block box (9.) 9.(MAX7.).1 19. -ø. Electrical entry Applicable O.D. ø. to ø8. Bracket EXH port station manifold, if the terminal block is located on the right side of the manifold assembly, the mounting bracket is located on the second Air-Catch Sensor. If the terminal block is located on the left side of the manifold assembly, the mounting bracket is located on the first Air-Catch Sensor. For manifolds with more than stations, the mounting brackets are located on the first and last Air-Catch Sensor. 0 0 (.) 1 GND VCC 1 Terminal block box wiring Adjusting knob 9-M 9.(MAX.7.) 19. Station 1.1 8-ø. n Dimensions Station 1 1 1 Electrical entry Applicable O.D. ø. to ø8. Bracket EXH port 180 71 1 0 11 Unit With DIN rail Manifold level indicator. 7 0 Terminal block box (9.) Electrical entry Applicable O.D. ø. to ø8. SUP. DIN rail center 0 0 (.) 1 1 SUP Adjusting knob level indicator. Station 1 1 0 Electrical entry Applicable O.D. ø. to ø8. n EXH port Terminal block box (9.) GND VCC Terminal block box wiring 9.(MAX7.) 19. Dimensions/With DIN rail Station 1 1 10 1 180 1 80 0 80 1.8-

Air Catch Sensor Dimensions/Individual Wiring (ead Wire Style) Unit With bracket Manifold Electrical entry (m) level indicator 9.(MAX78.) 19..1 0 Bracket -ø. EXH port For station manifold, the mounting bracket is located on the first Air-Catch Sensor. For manfolds with more than stations, the mounting brackets are located on the first and last Air-Catch Sensor. (18) SUP. DIN rail center 0 0 (.) 1 SUP Adjusting knob Electrical entry (m) level indicator 9.(MAX78.).119. 1 Station 1 8-ø. n Dimensions Station 1 10 71 Bracket 0 EXH. port 11 PSE ZSE ISE ZSE ISE ZSE ISE ZSE ISE GS PS ZSE1 ISE1 ZSE ISE ZSP IS Unit With DIN rail Electrical entry (m) Manifold 1 ZSM PF IF level indicator. (18) SUP. DIN rail center SUP level indicator. 0 0 (.) 1 Adjusting knob 9.(MAX78.) 19. Station 1 n EXH. port Dimensions/With DIN rail Station 1 10 10 10 80.8-

Guide for Use/Design Data When designing a pneumatic circuit with an Air-Catch Sensor, please refer to the data below. The detection distance for the Air-Catch Sensor is between to 00µm. When the supply pressure of the nozzle diameter changes reliable detection is not possible. Nozzel Diameter and Detection Distance The graphs below show the hysteresis in relationship to the detection distance. When high accuracy is required, design the system so the hysteresis is within the µm detection distance. When the Hysteresis exceeds µm use the Air-Catch Sensor as a confirmation of position of work piece. : Stable adjustment range Detection side nozzle: ø1.0 Detection side piping: ø X ø tubing Detection side nozzle: ø1. Detection side piping: ø X ø tubing Detection side nozzle: ø.0 Detection side piping: ø X ø tubing 0 0 Supply pressure 0 Supply pressure Detection Hysteresis (µm) 0 0 Supply pressure 0.1MPa Hysteresis (µm) 0 0 0.1MPa Hysteresis (µm) 0 0 0.1MPa not possible 0 0.1MPa 0.MPa 0 0.1MPa 0.MPa 0 0.1MPa 0.MPa 0 0 00 00 0 0 00 00 0 0 00 00 Example 1) When requiring 00µm detection, select the detection nozzle of ø1.0 with supply pressure 0.MPa. Example ) When requiring µm detection, select the detection nozzle of ø1.. Nozzle Shape Nozzle shape should be designed as follows. Pay attention to detection surface and the chamfer of nozzle hole as shown in Fig.1 since they can affect performance. Fig.1 ø1 ø1. ø Detection surface Chamfer not allowed or more or more or more ø or more ø or more ø or more.8-7

Air Catch Sensor Response Time The response time is dependent on the detection distance and the piping length. The supply pressure and the nozzle diameter do not influence the response time. Table shows the response time for different detection distance settings and a constant piping length. Table shows the response time when the detection distance is constant but the piping length changes. As can be seen from the graphs below, if the piping length is kept short and the detection distance is small, the response time is faster. Response time (sec)..0 1. 1.0 0. 0 Detection nozzle: ø1.0 Piping: ø X ø tubing m Supply pressure: 0.MPa Set value 0µm 0µm 00µm 00µm 0 0 10 00 0 00 0 Fig. Detection distance vs. Response time Response time (sec).0..0..0 1. 1.0 0. Detection nozzle: ø1.0 Piping: ø X ø tubing Supply pressure: 0.1MPa Detection distance: 0µm Piping length m 8m m m 1m PSE ZSE ISE ZSE ISE ZSE ISE ZSE ISE GS PS ZSE1 ISE1 ZSE ISE ZSP IS ZSM PF 0 0 0 IF Fig. Response time vs. Piping length Supply Pressure vs. Detection Distance The graphs below show the detection distance for different supply pressure setting. 00 Detection side nozzle: ø1.0 Detection side piping: ø X ø tubing 00 Detection side nozzle: ø1. Detection side piping: ø X ø tubing 00 Detection side nozzle: ø.0 Detection side piping: ø X ø tubing 00 0 00 0 00 0 0 0.1 0. 0. 0 0.1 0. 0. 0 0.1 0. 0. Supply pressure (MPa) Supply pressure (MPa) Supply pressure (MPa).8-8