Infilex ZM Zone Manager Model WY5122

Similar documents
Intelligent Component Series ACTIVAL Electro-Mechanical Actuator for Model VY530X Control Ball Valve Model MY5390A

Direct Coupled Damper Actuator Model MY6050A1001

Direct Coupled Damper Actuator Model MY9050A1001

Intelligent Component Series ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (PN16 / GG-20) (Spring Return Type Actuator)

Intelligent Component Series ACTIVAL Motorized Three-Way Valve with Flanged-End Connection (JIS 10K / FC200)

Intelligent Component Series ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (JIS 10K / FC200, SCS13A) (Spring Return Type Actuator)

Intelligent Component Series ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (JIS 10K / FC200, SCS13A)

Differential Pressure Transmitter

Pressure Transmitter

MIZCON Plus Cooling Tower Controller Model R7010W

Intelligent Component Series ACTIVAL Flow Measurement and Control Valve (JIS 10K / FC200)

ACTIVAL Motorized Three-Way Valve with Flanged-End Connection (JIS 10K / FC200)

ACTIVAL Two-way Ball Valve with Threaded-end Connection

ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (Spring Return Type Actuator) (JIS 10K-FC200, -SCS13A)

ACTIVAL Electro-Mechanical Actuator for Control Ball Valve

ACTIVAL Electro-Mechanical Actuator for Control Ball Valve Model MY53X0AX000

ACTIVAL Motorized Two-Way Valve with Flanged-End Connection for High Differential Pressure Application (JIS 10K-FC200, -SCS13A)

Motorized Two-Way Ball Valve with Screwed-End Connection

Operating Instructions (Translation)

HS6B Series Subminiature Interlock Switch

DC I/O Conversion Module FA1-TESV32XY FA1-TESV38COM User's Manual

Switching DC Power Supply

Valve Linkages Models Q455C, Q455D, Q455F

ACTIVAL Motorized Two-Way Valve with Flanged-End Connection <4-20 ma DC Input with 4-20 ma DC Feedback Output> (JIS 10K-FC200, -SCS13A)

SAFETY PRECAUTIONS (Always read these precautions prior to use.)

High-speed detection even a little liquid leak

ACTIVAL Electro-Mechanical Actuator for Control Ball Valve

ACTIVAL Flow Measurement and Control Valve Standalone Model (PN10 / GG-20)

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Insertion Thermostat

ComfortPoint Programmable Lon, VAV/Unitary Controllers

MODEL: PSN3. Final Control Elements. STROKE 6: 0 to 60 mm (0 to 2.36 )

ACTIVAL Three-Way Ball Valve with Threaded-End Connection

D4DL. Guard Lock Safety-door Switch. Model Number Structure

AS4V DC ALARM BEFORE USE... CAUTION WARNING INSTRUCTION MANUAL AS4V MODEL. (dual or quad alarm trip; field-configurable)

ThinkTop DeviceNetTM VDC DeviceNet is a Trademark of the Open DeviceNet Vendor Association, Inc. (ODVA).

HEAVY DUTY POWER RELAYS FEATURES

Extended Battery Cabinet for Nfinity

The Battery is a client module in the Cabinet Control. It is a backup/ups module which

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

DIGITAL TORQUE GAUGE MODEL BTGE-G

Battery Unit BHM60PC/BHM100PC Instruction Manual

Uninterruptible Power System

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Insertion Temperature/Humidity/ Dewpoint temperature Sensor HTY78X3/HY78X3/HTY78X6/HY78X6/HY79X3

SITESTAR ELECTRONICS CABINET DESCRIPTION

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

System 3 ZB1PS Device Chassis. Operator s Manual

Door Interlock Switches

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

TS , -850 Series TS , -850 Series TS-57031, TS

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Electronic Circuit Breaker ESS20-0..

Fuse state indicator MEg72. User manual

OPERATING MANUAL. High-efficiency AR Series. Stepping motor and driver package. Introduction. Applicable motor. Before use

Model Number Structure

Technical Documentation

MPA Chassis for Multi-Probe Magnetic Transducers

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

VF-S11 RS485 built-in board option RS4003Z Instruction Manual

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Metric Series Overview

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Installation Instructions

General Description. Product Specification. Document Digital Temperature Interlock

Hinged Safety Door Switch

Valve terminal VTUG-...-M/VTUG-...-V

G72x Series Direct Spark Ignition Controls

GETTING STARTED GUIDE NI AI, ±10 V, 12 Bit, 500 ks/s Aggregate

UZK12.071, UZO DATA 1. GENERAL DESCRIPTION 4. MARKINGS 3. ORDER NUMBERS PASSIVE BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

HS1C Interlock Switches with Solenoid

POWERWARE User s Guide VA.

Uninterruptible Power System

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

PHOENIX CONTACT

362 Clamp Meter. Users Manual

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Automatic Burnout Furnaces 115 to 230-volt Models OPERATOR S MANUAL

Series VQ Port Solenoid Valve

Uninterruptible power supply Supply MEg101.4

VA-7450 Series. Electric Valve Actuators

OPERATING INSTRUCTIONS

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

HS1E Series Full Size Solenoid Locking Switches

SIRIUS 3RU2 Thermal Overload Relays

POWER REGULATOR LD -40PSU

Models SPG5A and SPG6A

HYBRID HYDRAULIC O OIL COOLING EQUIPMENT O-1

Non-Contact Sensor for Workpiece Placement Verification

UZK12.071, UZO GENERAL DESCRIPTION 2. DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

Safety Precautions. Safety Precautions for

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

Installation Manual. OptoLoop. MiniBMS. Model Numbers

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

MEMS Air Velocity Sensor D6F-W. Application Examples. Ordering Information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Transcription:

Specifications/Instructions Infilex ZM Zone Manager Model WY5122 General Infilex ZM (Infilex: named for Infinity and Flexible ) Model WY5122, integrated into savic-net FX BMS (building management system), manages remote units (also called sub-controllers), such as Infilex VC, Infilex FC, and Infilex SC. Up to 50 remote units can be connected. Infilex ZM can control these units separately as well as per group. Infilex ZM communicates with the savic-net FX center unit through the transmission trunk line NC-bus and with the remote units through the transmission trunk line. Features Compact design: Small size body ensures space saving. Installation: A quick-fit screwless (clamp) terminal block is used for the communication terminal block of the I/O module, ensuring the labor saving of the wiring work. Additionally, either DIN rail mounting or screw mounting can be selected. Management of remote units: Infilex ZM manages up to 50 connected remote units (Infilex VC, Infilex FC, Infilex SC, etc.), allowing ON/OFF, failure monitoring, measuring, and setting individually from the BMS center unit. Infilex ZM can perform such managements of remote units by group and is applicable to any group configuration consisting of up to 50 units of Infilex VC and Infilex FC. Additionally, Infilex ZM provides flexible management. For example, group ON/OFF can be commanded even when individual measuring is commanded. Risk diversification and high-speed supervision: Infilex ZM has 50 programs of time schedules, analog alarm monitoring, and runtime/cycle-count integrating in order to manage the connected Infilex VC, Infilex FC, Infilex SC, etc. This achieves diversification of risks and high-speed supervision of BMS. Azbil Corporation s controller Infilex series: Infilex is named for Infinity and Flexible. One Infilex ZM controls up to 4 sets of VAV (VAV: variable air volume, controlled by Infilex VC) and AHU (controlled by Infilex GC). Load reset control of supply air temperature, fan speed control, interlocking operation are available. Additionally, the mixing loss control of the interior VAV and perimeter FCU (fan coil unit) can be performed. Support functions: Infilex ZM supports to adjust VAV by setting the max./min. air volume levels of all VAV units included in a specified set. Infilex ZM also supports to adjust AHU/FCU flow rate and to flush the piping by fully opening and closing all the valves that the Infilex ZM controls. CE Marking certified product: Infilex ZM Model WY5122W0000 (NC-bus model (Line A)) conforms to all the applicable standards of CE Marking (Class A). 1

Safety Instructions Please read instructions carefully and use the product as specified in this manual. Be sure to keep this manual near by for ready reference. Usage Restrictions This product is targeted for general air conditioning. Do not use this product in a situation where human life may be affected. If this product is used in a clean room or a place where reliability or control accuracy is particularly required, please contact Azbil Corporation s sales representative. Azbil Corporation will not bear any responsibility for the results produced by the operators. WARNING DANGER: To prevent the risk of severe or fatal electrical shock, always disconnect power source and product power supply before performing any wiring. Be sure to ground with 100 or lower ground resistance. Improper grounding may cause electrical shock or equipment damages. Do not detach the terminal cover at any time except when wiring. After wiring, be sure to attach the terminal cover. Before attaching/detaching the terminal cover, make sure that the wires are not current-carrying to prevent electrical shock. Disconnect power before the product replacement to prevent electrical shock. Wire strip length to be connected to the quick-fit screwless terminal block must be 8 mm. If the strip length is longer than 8 mm, the conductor will be exposed, causing electrical shock or short circuit between adjacent terminals. If it is shorter, the conductor will not contact the connector. Do not disassemble the product. Disassembly may result in electrical shock or equipment damage. CAUTION Installation and wiring must be performed by qualified personnel in accordance with all applicable safety standards. This product must be operated under the operating conditions (power, temperature, humidity, vibration, shock, installation position, atmospheric condition, etc) specified in this manual to prevent equipment damages. All wiring must comply with local codes of indoor wiring and electric installation rules. Use crimp terminal lugs with insulation for electric wires connected to the screw terminals. Connect cables to the power source with terminals or the like for permanent connection. Make sure all the wires are tightly connected to prevent heat generation or equipment damages. If more than the rated power supply voltage is applied, product replacement is required for safety. Install this product in a location out of reach of unauthorized people. (e.g. Inside of the control panel cabinet) Lightening protection based on the regional characteristics and the building structure is needed to minimize equipment damages. Noise protection is necessary when the product is installed in a location close to many noise sources. Do not block the vent holes on the upper or lower part of the product to prevent equipment damages. Remove protective sheet after installation and wiring. After mounting on DIN rail, make sure that the holding parts of all the connected modules are securely fixed on the DIN rail. The modules may drop from the DIN rail and get damaged due to improper mounting. Dispose of the lithium battery in accordance with your local regulations. Dispose of this product in accordance with your local regulations. Do not reuse all or a part of this product. Trademark information: Infilex, Neopanel, PARAMATRIX and savic-net are trademarks or registered trademarks of Azbil Corporation in Japan or in other countries. BACnet is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). 2

System Configurations MIS SMS DSS Client PC BACnet IP SCS NC-bus* (Max. 25 units and 500 m, but extendable up to 1000 m with the repeater module.) Infilex AC Model WY5117C Infilex GC Model WY5111 Infilex GD Model WY5110 Infilex ZM Model WY5122 Other connectable units to NC-bus: DIF/DIF-II/BMIF/energy meter Note that the number of units to be connected must satisfy the following formula. (Infilex ZM + DIF + DIF-II + BMIF) 5 units number of NC-bus lines Neopanel Model QY7205 (Digital user terminal) Neoplate Model QY7290 (Analog user terminal) (Max. 50 units and 1000 m) BMIF: Building Multi Air-Conditioning Interface DIF: DGP (Data Gathering Panel) Interface DIF-II: DGP Interface-II DSS: Data Storage Server MIS: Management Integration Server NC-bus: New Controller bus PMX-III: PARAMATRIX -III : Sub Controller bus SCS: System Core Server SMS: System Management Server PMX-III Model WY2001 Infilex SC Model WY5207W Infilex FC Model WY5205 Infilex VC Model WY5206 Neopanel Model QY7205 (Digital user terminal) Neopanel Model QY7205 (Digital user terminal) Note: MIS may be used instead of SMS and DSS for your system. Note that MIS cannot be mixed with SMS or DSS in the same system. Figure 1. System configuration example Neoplate Model QY7290 (Analog user terminal) Model Numbers Model number WY5122 Basic model number W 100 V AC to 240 V AC power 0000 NC-bus model (Line A) * CE Marking (Class A) certified 0010 Redundant NC-bus model (Lines A and B) Description Parts for Installation Part number Description 83165861-001 Screw tab 83104567-001 DIN rail mounting bracket Note: For mounting Infilex ZM, either the screw tab (for screw mounting) or the DIN rail mounting bracket (for DIN rail mounting) is required. Be sure to separately order depending on your mounting type. 3

Specifications Basic specifications Item Specification Rated voltage 100 V AC to 240 V AC, 50 Hz/60 Hz Allowable voltage range 85 V AC to 264 V AC, 50 Hz/60 Hz Power supply Power shutdown detection 80 V AC or less Power consumption 35 VA (when 50 remote units (sub- controllers) are connected from the Infilex ZM) Leakage current 1 ma or less Ambient temperature 0 C to 50 C Rated operating Ambient humidity 10 %RH to 90 %RH (non-condensing) conditions Altitude 2000 m or lower Vibration Max. 5.9 m/s 2 (0.6 G) at 10 Hz to 150 Hz Environmental Ambient temperature -20 C to 60 C conditions Ambient humidity 5 %RH to 95 %RH (non-condensing) Transport/ Vibration for storage Max. 5.9 m/s 2 (0.6 G) at 10 Hz to 150 Hz storage conditions Vibration for Max. 9.8 m/s 2 (1 G) at 10 Hz to 150 Hz transportation Power supply Green LED ON: Power ON (POWER) Green LED OFF: Power OFF Operation Major failure (ERR1) Red LED ON: Major failure or system restart Red LED OFF: Normal operation Minor failure (ERR2) Red LED ON: Minor failure or system restart Red LED OFF: Normal operation NC-bus Transmit (TX), Receive (RX) Communication LED indication Transmit (TX), Receive (RX) LED Flashing ON OFF POWER ON OFF NC-bus TX Normal Abnormal Description of LED NC-bus RX Normal Abnormal indication TX Normal Abnormal RX Normal Abnormal ERR1 Abnormal Normal ERR2 Abnormal Normal Power failure backup RAM, RTC* Lithium battery backup Data file Non-volatile memory (flash memory) backup Transmission system Current transmission Transmission speed 4800 bps NC-bus Transmission distance 500 m Remote units (controllers) Max. 25 units connectable Transmission system Voltage transmission Transmission speed 4800 bps Transmission distance 1000 m Remote units (sub-controllers) Max. 50 units connectable Weight 400 g Material (housing), color Modified PPE, light gray Terminal block Power supply, ground M3 (7.62 mm pitch between terminals) NC-bus communication Quick-fit screwless terminal block Note: RTC: Real Time Clock. RTC is backed up by a lithium battery to ensure accurate clocking while the power is OFF. Communications 4

Wiring specifications Item Wiring Wiring length Condition Power supply JIS IV2.0 mm 2 or JIS CVV 2.0 mm 2 or greater Ground JIS IV 2.0 mm 2 or JIS CVV 2.0 mm 2 or greater Ground resistance: 100 or lower NC-bus JCS IPEV-S 0.9 mm 2 500 m LAN cable compliant with EIA/TIA-568 category 3 or over 1000 m Notes: As M3 screw terminal block is used for power supply and ground, crimped terminal lug is required for the cable end. Since a quick-fit screwless terminal block is provided for NC-bus connection, the wires can be connected only by stripping the sheath. Sheath stripped length: 8 mm (Pin terminal cannot be used.) Organize the cables with cable binding bands so as not to hide LED, Data Setter connector, mark, switch, battery holder, or tag. JIS: Japanese Industrial Standards JCS: Japanese Electric Wire and Cable Makers Association CE Marking Conformity This product must be installed in a panel cabinet. Besides, the product in the panel cabinet must be out of reach of unauthorized people who are not well-trained for electric facilities. This product complies with the following Electromagnetic Compatibility (EMC) and the Low Voltage Directive (LVD). EMC: EN61326-1 Class A, Table 2 (For use in an industrial electromagnetic environment) LVD : EN61010-1 Overvoltage category II Pollution degree 2 Input/Output Terminal Arrangement 100 V AC to 240 V AC 1 2 3 4 TX IN TX OUT (+) (-) Shield Shield (+) (-) 5 6 7 8 9 10 NC-bus Line A TX IN (+) 11 NC-bus Line B TX Out (-) 12 RJ-45 modular jack Figure 2. Input/output and terminal arrangement example 5

Dimensions 60 90 1 2 3 ~ E NC-bus Tx RX Tx RX 4 I ERR1 ERR2 S1 H-MMI O POWER BATT. NC-bus + - S S + - + - 5 6 7 8 9 10 11 12 140 Stripping Length 8mm CN1 Figure 3. Dimensions (mm) 6

Parts Identification 1 2 3 4 ~ E NC-bus Tx RX Tx RX LED for operating status Power switch LED for power ON/OFF Battery holder I O POWER BATT. NC-bus + - S S + - + - ERR1 ERR2 S1 H-MMI 5 6 7 8 9 10 11 12 S1 switch* Connector (female) for Data Setter Do not press S1 switch. DIN rail mounting hook Stripping Length 8mm CN1 Figure 4. Parts identification LED indication Data transmitting Data receiving Data transmitting Data receiving Major failure / initializing Minor failure / initializing Table 1. Indication and operation of operating status LED LED operation NC-bus TX LED: flashing NC-bus RX LED: flashing TX LED: flashing RX LED: flashing ERR1: ON ERR2: ON Connections of Data Setter (H-MMI) 1) Connection of Data Setter Model QY5111A No conversion cable is required. Directly insert the male connector of the Data Setter into the female connector provided on the Infilex ZM main unit. At this time, hold the male connector with the mark facing left and insert it as the mark points to the mark on the Infilex ZM main unit. 2) Connection of Data Setter Model QY7211A Convert the D-SUB connector to the mini DIN connector with the conversion cable (Part No. 83104995-001). At this time, hold the male connector with the mark facing left and insert it as the mark points to the mark on the Infilex ZM main unit. Insert the connector as the two arrows point to each other. Figure 5. Connecting Data Setter 7

Mounting Dimensions DIN rail mounting Mount and fix Infilex ZM on DIN rail so that it does not fall from the DIN rail. Fasten the bilateral sides of Infilex ZM with two DIN rail mounting brackets (Part No. 83104567-001, separate order is required). 20 60 20 92 (60) (122.5)* 1 (132.5)* 1 65 75 DIN rail Infilex ZM Duct (45) 35 140 35 (45) DIN rail mounting bracket (for bilateral sides) Part No. 83104567-001 DIN rail position is shifted 5 mm downward from the center of Infilex ZM. Duct Infilex ZM Duct DIN rail Hook Infilex ZM Holder Notes: 1 Pitch between upper/lower duct and DIN rail. 2 Hatched area shows the maintenance clearance. (60) Figure 6. Mounting dimensions: DIN rail mounting (mm) Direct screw-mounting When Infilex ZM is mounted with screws, the screw tab (Part No. 83165861-001) is required. Mount and fix Infilex ZM on the wall with two M4 8 screws. Lengthwise mounting 20 60 20 Incorrect mounting: Crosswise* 2 (face-up) 35 140 35 *1 Infilex ZM Infilex ZM 154 Screw tab Part No. 83165861-001 Rear side Screw tab To attach the screw tab, insert the screw tab into the slit provided on the rear side of Infilex ZM. DIN rail holder Pull out the DIN rail holder. Vertical direction Notes: 1 Hatched are shows the maintenance space. 2 Do not mount Infilex ZM in crosswise (face-up) direction. Do not mount it with the surface plate facing upward or downward, either. Figure 7. Mounting dimensions: Direct screw mounting (mm) 8

Wiring Wiring from power supply to terminal block Attach the crimp terminals for the M3 screw terminal block to the wire ends, and connect them to the terminal block. Wiring to the NC-bus Terminal Block Since quick-fit screwless terminal block is used for the NC-bus terminal block, the procedure for wiring is specified as follows. 1) Strip the wire sheath 8 mm. (The gauge for the strip length is located at the front lower part of Infilex ZM main unit. If the stripped part is longer than 8 mm, the conductor will be exposed, causing electrical shock or short circuit between adjacent terminals. If it is shorter, the conductor may not contact the connector.) 2) Make sure that no wire fiber is protruded from the stripped conductor. 3) Press the button on the terminal block deeply enough to insert the wire using a slotted screwdriver. (Maximum button-pressing force is 14 N {1.4 kgf}.) 4) Release the button, and gently pull out the wire to make sure that it is tightly fastened. (If you pull out the wire diagonally, it may be disconnected.) Make sure that no wire fiber is protruded from the stripped conductor. Precautions for connected cables Neatly place the cables connected to Infilex ZM so as not to hide the parts shown in Fig. 8. Make sure there is no slack in the wires from the cable ducts to Infilex ZM. System indication label for the controller number The indication tag has the system indication label on its back. Turn it over and fill in the controller number on the label. Turn over. Figure 9. System indication label Protective sheet After wiring installation, be sure to peel off the protective sheet before turning on the power. 1) Adhesive is applied to the sheet approximately 20 mm from the front edge. Peel off this area. 2) Tear off the sheet along the perforations. 1) Peel off the adhesive area. 2) Tear off. Indication tag Figure 10. Protective sheet Power switch LED LED S1 switch Connector for Data Setter Battery holder Tube marker Since Infilex ZM adopts quick-fit screwless terminal block for communication, communication cables are connected to the terminals without crimp terminal lugs. Therefore, if normal tube markers are used, they may come off when the cables are disconnected. To prevent this, use the Flat Tube Marker. It is held on a cable by friction and thus does not come off easily. Manufacturer Phoenix Contact Part name Flat Tube Marker Part number 5880029 Model TMC-3 Applicable wire size 0.4 mm 2 to 2 mm 2 Package unit 200 m/roll Indication tag Figure 8. Connected wires in position 9

Maintenance (Lithium Battery Replacement) Replace the lithium battery for backup (Part No. 83104934-001) every 5 years. IMPORTANT: Only authorized service personnel is allowed to replace the battery. Do not touch the power supply unit when replacing the battery. Since the remaining battery capacity cannot be checked by measuring the terminal voltage, be sure to replace the battery every 5 years. Replace the lithium battery with the power ON. Replace the lithium battery every 5 years if the product is always in use (in ON state). If the product has never or hardly been operated (in OFF state) for a year, replace the lithium battery before the product operation. Battery replacement 1) Lithium battery for backup 2) 4) 3) Infilex ZM main body 5) Battery holder Battery Connector Replace the battery with the Infilex ZM in ON state. Figure 11. Battery replacement 1) Pull out the battery holder using a slotted screwdriver. 2) Disconnect the connector and detach the lithium battery from the battery holder. 3) Place a new lithium battery in the battery holder and connect the connector to it. 4) Insert the battery holder into the main unit. 5) Fill in the date for next replacement (5 years after the replacement) on the tag using an oil-based pen. 10

Precautions for Use Do not mount the product under the conditions of high temperature and humidity. Do not drop the product. For the wire replacement, be sure to shut down the power. (Disconnect the wiring between the power supply and the product power terminals.) Before turning on the power, make sure that the wires are correctly connected. Several tens of seconds are required for the product normal operation after the power is turned on. During this time, the red LED ERR1 (major failure) on the front lights up indicating major failure temporarily, but this does not indicate an error. Do not connect wires to vacant terminals. Leave at least 35 mm clearance between the top/bottom surfaces of the product and other devices. Peel off the protective sheet on the top surface of the product before turning ON the power. (See Figs. 10 and 12.) Protective sheet Battery label on the Indication tag Figure 12. Battery label on the indication tag and protective sheet 11

Specifications are subject to change without notice. Building Systems Company http://www.azbil.com/ Rev.8.0 Sep. 2015 (J: AI-6439 Rev. 4.2) 12 AB-6439 H (W03) Printed in Japan.