SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 130 kw 163 kva 60 Hz

Similar documents
SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 60 kw 75 kva 60 Hz

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 20 kw 25 kva 60 Hz

SD L 130 kw INDUSTRIAL DIESEL GENER ATOR SE T EPA Certified Stationary Emergency

SD L 40 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 150 kw 188 kva 60 Hz

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 70 kw 88 kva 60 Hz

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 130 kw 163 kva 60 Hz

Power Ratings. Standby SG kva / 320 kw. Prime PG kva / 288 kw

Standby Rated Generators. Standby SG kva / 28 kw. Prime PG kva / 22 kw

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency POWERING AHEAD CODES AND STANDARDS

Power Ratings. Standby SG kva / 160 kw. Prime and standby ratings based on 3-Phase voltages. Model number based on kw rating.

SG L 250 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

Power Ratings. Standby SG kva / 240 kw. Prime PG kva / 192 kw

SG L 35 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

SG L 50 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

Standby Rated Generators. Standby SG kva / 184 kw. Prime PG kva / 147 kw

MD L 400 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

SG L 300 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

MG L 150 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

SD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. SD kw

G130LG2 6.8L. Industrial Spark-Ignited Generator Set. Codes and Standards. G130LG2 130 kw. Standby Power Rating 130 kw 163 kva 60 Hz

G150LG4 12.9L. Industrial Spark-Ignited Generator Set. Codes and Standards. G150LG4 150 kw. Standby Power Rating 150 kw 188 kva 60 Hz

SD L 1000 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

MD L 1000 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

MD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. MD kw. Standby Power Rating 1000 kw 1250 kva 60 Hz

INDUSTRIAL DIESEL GENER ATOR SE T CODES AND STANDARDS POWERING AHEAD. STANDBY POWER RATING 400 kw, 500 kva, 60 Hz

MD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. MD kw

SB600/MB600. Industrial Bi-Fuel Diesel Generator Set. features. primary codes and standards. 600 kw Bi-Fuel. Standby Power Rating 600 kw 750 kva 60 Hz

SB500/MB500. Industrial Bi-Fuel Diesel Generator Set. 500 kw Bi-Fuel. features. primary codes and standards. Standby Power Rating 500 kw 625 kva 60 Hz

SG L 350 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

QT025A 2.4L 25 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

G150LG6. Industrial Spark-Ignited Generator Set. Codes and Standards. G150LG6 150 kw. Standby Power Rating 150 kw 188 kva 60 Hz

MG L 130 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET. Codes and Standards. Powering Ahead. Standby Power Rating 130 kw, 163 kva, 60 Hz

MDG75DF4 4.5L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

SG070. Industrial Gaseous Generator Set. SG070 70kW. primary codes and standards. Standby Power Rating 88kVA 70kW 60 Hz

SG L 130kW POWERING AHEAD. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

PROTOTYPE & TORSIONALLY TESTED UL2200 TESTED RHINOCOAT PAINT SYSTEM WIDE RANGE OF ENCLOSURES EPA COMPLIANT INDUSTRIAL TESTED, GENERAC DESIGNED

SG150. Industrial Gaseous Generator Set. SG kW. primary codes and standards. Standby Power Rating 188kVA 150kW 60 Hz

70 kw GENERAC STANDBY GENERATORS. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES: Standby Power Rating Model QT070 (Bisque) - 70 kw 60Hz

GENERAC GUARDIAN SERIES STANDBY GENERATORS

DATA CENTER SOLUTIONS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

PROTOTYPE & TORSIONALLY TESTED PROVIDES A PROVEN UNIT UL2200 TESTED ENSURES A QUALITY PRODUCT RHINOCOAT PAINT SYSTEM IMPROVES RESISTANCE TO ELEMENTS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

G130LG. Industrial Gaseous Generator Set. G130LG 130kW. primary codes and standards. Standby Power Rating 163kVA 130kW 60 Hz

MG L 150kW POWERING AHEAD. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

MDG75DF4 4.5 L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

22 kva GENERAC STANDBY GENERATORS ISO. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES:

GENERAC GUARDIAN SERIES STANDBY GENERATORS

Diesel generator set QSK23 series engine

PROTOTYPE & TORSIONALLY TESTED UL2200 TESTED RHINOCOAT PAINT SYSTEM WIDE RANGE OF ENCLOSURES AND TANKS EPA TIER COMPLIANT

GENERAC GUARDIAN SERIES STANDBY GENERATORS

MD300. Industrial Diesel Generator Set. 300 kw Diesel. primary codes and standards. Standby Power Rating 375kVA 300kW 60Hz

G300LG. Industrial Gaseous Generator Set. G300LG 300kW. primary codes and standards. Standby Power Rating 375kVA 300kW 60 Hz

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

13,000 Watt Diesel Generator AGi13P E

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

Diesel generator set QSX15 series engine

10,000 Watt Diesel Generator AGi9P E

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Diesel generator set QSB7 series engine

DIESEL GENERATOR SET. 60 Hz FEATURES

60 Hz FEATURES. Exclusively from your Caterpillar dealer

STANDBY GENERATOR 80 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

DIESEL GENERATOR SETS

Diesel generator set QSK23 series engine

MD400. Industrial Diesel Generator Set. 400 kw Diesel. primary codes and standards. Standby Power Rating 500kVA 400kW 60Hz PARALLELING UNIT

MDG100DF4CAN 4.5 L 100 kva MOBILE DIESEL GENERATOR SET. Codes and Standards Generac Mobile products are designed to the following standards:

STANDBY GENERATOR 25 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

STANDBY GENERATOR 130 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 100 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

SG L 300kW. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

Diesel generator set QSX15 series engine

Standby Generators ISO FEATURES. Standby Generators Liquid-Cooled Gaseous Engine. Standby Generators INCLUDES:

60 Hz FEATURES. Exclusively from your Caterpillar dealer

SG L 200kW. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

MG300. Industrial Gaseous Generator Set. MG kW. primary codes and standards. Standby Power Rating 375kVA 300kW 60 Hz PARALLELING UNIT

G100U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

Spark-ignited generator set

Quietsource Series ISO. QUIETSOURCE SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Quietsource Series INCLUDES:

RENTAL DIESEL GENERATOR SET

Guardian Series. GUARDIAN SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Guardian Series INCLUDES:

Protector Series ISO FEATURES. Standby Generators Liquid-Cooled Gas Engine INCLUDES:

1P 120/240V, 3600 RPM,

Centurion Series. CENTURION SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Centurion Series INCLUDES:

DG175 GC to DG450 GC GAS GENERATOR SETS

Spark-ignited generator set

Diesel generator set 6BT5.9 series engine

G80U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

Transcription:

SD130 6.7L Industrial Diesel Generator Set EPA Certified Stationary Emergency SD130 130 kw 1 of 6 Power Rating 130 kw 163 kva 60 Hz Prime Power Rating* 117 kw 146 kva 60 Hz *EPA Certified Prime ratings are not available in the U.S. or its Territories Codes and Standards *Built in the USA using domestic and foreign parts Generac products are designed to the following standards: UL2200, UL508, UL142, UL498 NFPA70, 99, 110, 37 NEC700, 701, 702, 708 ISO9001, 8528, 3046, 7637, Pluses #2b, 4 Powering Ahead Image used for illustration purposes only For over 50 years, Generac has led the industry with innovative design and superior manufacturing. Generac ensures superior quality by designing and manufacturing most of its generator components, including alternators, enclosures and base tanks, control systems and communications software. Generac s gensets utilize a wide variety of options, configurations and arrangements, allowing us to meet the standby power needs of practically every application. NEMA ICS10, MG1, 250, ICS6, AB1 ANSI C62.41 IBC 2009, CBC 2010, IBC 2012, ASCE 7-05, ASCE 7-10, ICC-ES AC-156 (2012) Generac searched globally to ensure the most reliable engines power our generators. We choose only engines that have already been proven in heavy-duty industrial application under adverse conditions. Generac is committed to ensuring our customers service support continues after their generator purchase.

SD130 130 kw SD130 Standard Features ENGINE SYSTEM ALTERNATOR SYSTEM ENCLOSURE (if selected) 2 of 6 General Oil Drain Extension Air Cleaner Fan Guard Stainless Steel flexible exhaust connection Critical Exhaust Silencer (enclosed only) Factory Filled Oil Radiator Duct Adapter (open set only) Fuel System Fuel lockoff solenoid Primary fuel filter Cooling System Closed Coolant Recovery System UV/Ozone resistant hoses Factory-Installed Radiator Radiator Drain Extension 50/50 Ethylene glycol antifreeze 120 VAC Coolant Heater Engine Electrical System Battery charging alternator Battery cables Battery tray Solenoid activated starter motor Rubber-booted engine electrical connections UL2200 GENprotect 12 leads (3-phase, non 600 V) Class H insulation material Vented rotor 2/3 pitch Skewed stator Auxiliary voltage regulator power winding Amortisseur winding Brushless Excitation Sealed Bearings Automated manufacturing (winding, insertion, lacing, varnishing) Rotor dynamically spin balanced (get tolerance) Full load capacity alternator Protective thermal switch GENERATOR SET Internal Genset Vibration Isolation Separation of circuits - high/low voltage Separation of circuits - multiple breakers Silencer Heat Shield Wrapped Exhaust Piping Silencer housed in discharge hood (enclosed only) Standard Factory Testing 2 Year Limited Warranty ( rated Units) 1 Year Limited Warranty (Prime rated units) Silencer mounted in the discharge hood (enclosed only) Rust-proof fasteners with nylon washers to protect finish High performance sound-absorbing material Gasketed doors Stamped air-intake louvers Air discharge hoods for radiator-upward pointing Stainless steel lift off door hinges Stainless steel lockable handles Rhino Coat - Textured polyester powder coat TANKS (if selected) UL 142 Double wall Vents Sloped top Sloped bottom Factory pressure tested (2 psi) Rupture basin alarm Fuel level Check valve in supply and return lines Rhino Coat - Textured polyester powder coat Stainless hardware CONTROL SYSTEM Control Panel Digital H Control Panel - Dual 4x20 Display Programmable Crank Limiter 7-Day Programmable Exerciser Special Applications Programmable PLC RS-232/485 All-Phase Sensing DVR Full System Status Utility Monitoring Low Fuel Pressure Indication 2-Wire Start Compatible Power Output (kw) Power Factor kw Hours, Total & Last Run Real/Reactive/Apparent Power All Phase AC Voltage All Phase Currents Oil Pressure Coolant Temperature Coolant Level Engine Speed Battery Voltage Frequency Date/Time Fault History (Event Log) Isochronous Governor Control Waterproof/sealed Connectors Audible Alarms and Shutdowns Not in Auto (Flashing Light) Auto/Off/Manual Switch E-Stop (Red Mushroom-Type) NFPA110 Level I and II (Programmable) Customizable Alarms, Warnings, and Events Modbus protocol Predictive Maintenance algorithm Sealed Boards Password parameter adjustment protection Single point ground 15 channel data logging 0.2 msec high speed data logging Alarm information automatically comes up on the display Alarms Oil Pressure (Pre-programmable Low Pressure Coolant Temperature (Pre-programmed High Temp Coolant Level (Pre-programmed Low Level Low Fuel Pressure Alarm Engine Speed (Pre-programmed Over speed Battery Voltage Warning Alarms & warnings time and date stamped Alarms & warnings for transient and steady state conditions Snap shots of key operation parameters during alarms & warnings Alarms and warnings spelled out (no alarm codes)

SD130 Configurable Options ENGINE SYSTEM ALTERNATOR SYSTEM ENCLOSURE SD130 130 kw General Oil Make-Up System Oil Heater Industrial Exhaust Silencer Fuel System Flexible fuel lines Primary fuel filter Engine Electrical System 10A UL battery charger 2.5A UL battery charger Battery Warmer Alternator Upsizing Anti-Condensation Heater Tropical coating Permanent Magnet Excitation CIRCUIT BREAKER OPTIONS Main Line Circuit Breaker 2nd Main Line Circuit Breaker Shunt Trip and Auxiliary Contact Electronic Trip Breakers GENERATOR SET Gen-Link Communications Software (English Only) IBC Seismic Certification 8 Load Position Load Center 2 Year Extended Warranty 5 Year Warranty 5 Year Extended Warranty Weather Protected Level 1 Sound Attenuation Level 2 Sound Attenuation Steel Enclosure Aluminum Enclosure 150 MPH Wind Kit 12 VDC Enclosure Lighting Kit 120 VAC Enclosure Lighting Kit AC/DC Enclosure Lighting Kit Door Alarm Switch TANKS (Size on last page) Electrical Fuel Level Mechanical Fuel Level 8" Vent Extension 13" Vent Extension 19" Vent Extension 3 of 6 CONTROL SYSTEM 21-Light Remote Annunciator Remote Relay Panel (8 or 16) Oil Temperature Sender with Indication Alarm Remote E-Stop (Break Glass-Type, Surface Mount) Remote E-Stop (Red Mushroom-Type, Surface Mount) Remote E-Stop (Red Mushroom-Type, Flush Mount) Remote Communication - Modem Remote Communication - Ethernet 10A Run Relay Ground fault indication and protection functions Engineered Options ENGINE SYSTEM ALTERNATOR SYSTEM ENCLOSURE Coolant heater ball valves Block Heaters Fluid containment pans CONTROL SYSTEM Spare inputs (x4) / outputs (x4) - H Panel Only Battery Disconnect Switch 3rd Breaker System GENERATOR SET Special Testing Motorized Dampers Door switched for intrusion alert Enclosure ambient heaters TANKS Overfill protection valve UL2085 Tank ULC S-601 Tank Stainless Steel Tank Special Fuel Tanks (MIDEQ and FL DEP/DERM, etc.) Vent Extensions Rating Definitions Applicable for a varying emergency load for the duration of a utility power outage with no overload capability. Prime Applicable for supplying power to a varying load in lieu of utility for an unlimited amount of running time. A 10% overload capacity is available for 1 out of every 12 hours. The Prime Power option is only available on International applications. Power ratings in accordance with ISO 8528-1, Second Edition dated 2005-06-01, definitions for Prime Power (PRP) and Emergency Power (ESP).

SD130 130 kw 4 of 6 SD130 ENGINE SPECIFICATIONS General Make Iveco/FPT EPA Emissions Compliance Stationary Emergency EPA Emissions Reference See Emission Data Sheet Cylinder # 6 Type In-Line Displacement - L (cu in) 6.7 (408.86) Bore - mm (in) 104 (4.09) Stroke - mm (in) 128 (5.2) Compression Ratio 16.5:1 Intake Air Method Turbocharged/Aftercooled Cylinder Head Type 2 Valve Piston Type Alloy Aluminum Crankshaft Type Forged Steel Engine Governing Governor Electronic Isochronous Frequency Regulation (Steady State) ± 0.25% application and engineering data Cooling System Cooling System Type Closed Recovery Water Pump Flow Belt Driven Centrifugal Fan Type Pusher Fan Speed (rpm) 2538 rpm Fan Diameter mm (in) 599 (23.6) Coolant Heater Wattage 1500 Coolant Heater Standard Voltage 120 V /240 V Fuel System Fuel Type Ultra Low Sulfur Diesel Fuel Fuel Specifications ASTM Fuel Filtering (microns) 5 Fuel Inject Pump Stanadyne Fuel Pump Type Engine Driven Gear Injector Type Mechanical Fuel Supply Line - mm (in) 12.7 (0.5) NPT Fuel Return Line - mm (in) 12.7 (0.5) NPT Lubrication System Oil Pump Type Gear Oil Filter Type Full Flow Crankcase Capacity - L (qts) 17 (18) Engine Electrical System System Voltage Battery Charging Alternator Battery Size Battery Voltage Ground Polarity 12 VDC Std See Battery Index 0161970SBY 12 VDC Negative ALTERNATOR SPECIFICATIONS Standard Model 390 mm Poles 4 Field Type Revolving Insulation Class - Rotor H Insulation Class - Stator H Total Harmonic Distortion < 3% Telephone Interference Factor (TIF) < 50 Standard Excitation Synchronous Brushless Bearings Single Seated Cartridge Coupling Direct, Flexible Disc Load Capacity - 100% Prototype Short Circuit Test Yes Voltage Regulator Type Digital Number of Sensed Phases All Regulation Accuracy (Steady State) ± 0.25%

SD130 POWER RATINGS Single-Phase 120/240 VAC @1.0pf 130 kw Amps: 542 Three-Phase 120/208 VAC @0.8pf 130 kw Amps: 451 Three-Phase 120/240 VAC @0.8pf 130 kw Amps: 391 Three-Phase 277/480 VAC @0.8pf 130 kw Amps: 195 Three-Phase 346/600 VAC @0.8pf 130 kw Amps: 156 operating data SD130 130 kw 5 of 6 STARTING CAPABILITIES (skva) skva vs. Voltage Dip 480 VAC 208/240 VAC Alternator kw 10% 15% 20% 25% 30% 35% 10% 15% 20% 25% 30% 35% Standard 130 116 174 323 290 348 406 87 131 174 218 261 305 FUEL CONSUMPTION RATES* Diesel - gph (lph) Fuel Pump Lift - ft (m) Percent Load gph (lph) 3 (1) 25% 2.9 (11.0) 50% 5.4 (20.4) Total Fuel Pump Flow (Combustion + Return) 75% 7.7 (29.1) 29.1 gph 100% 9.6 (36.3) * Fuel supply installation must accommodate fuel consumption rates at 100% load. COOLING Coolant Flow per Minute gpm (lpm) 44.6 (168.8) Coolant System Capacity gal (L) 5.65 (21.4) Heat Rejection to Coolant BTU/hr 353,900 Inlet Air cfm (m3/hr) 7900 (223.7) Max. Operating Radiator Air Temp Fº (Cº) 122 (50) Max. Ambient Temperature (before derate) Fº (Cº) 104 (40) Maximum Radiator Backpressure in H 2 O 0.5 COMBUSTION AIR REQUIREMENTS Flow at Rated Power cfm (m3/min) 390 (11.05) ENGINE Rated Engine Speed rpm 1800 Horsepower at Rated kw** hp 198 Piston Speed ft/min (m/min) 1559 (475) BMEP psi 213 ** Refer to Emissions Data Sheet for maximum bhp for EPA and SCAQMD permitting purposes. EXHAUST Exhaust Flow (Rated Output) cfm (m 3 /min) 910 (25.8) Max. Backpressure (Post Silencer) inhg (Kpa) 1.5 (5.1) Exhaust Temp (Rated Output) ºF (ºC) 960 (516) Exhaust Outlet Size (Open Set) mm (in) 101.6 (4) Deration Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions. Please consult a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528 and DIN6271 standards.

SD130 130 kw 6 of 6 SD130 OPEN SET dimensions and weights* WT lbs (kg) - Tank & Open Set NO TANK - 110 (2794) x 40 (1016) x 65 (1651) 3104 (1408) 9 90 (340.7) 110 (2794) x 40 (1016) x 77 (1955.8) 3813 (1730) 23 220 (832.8) 110 (2794) x 40 (1016) x 89 (2260.6) 4146 (1881) 36 350 (1324.9) 110 (2794) x 40 (1016) x 101 (2565.4) 4488 (2036) 53 510 (1930.6) 110 (2794) x 40 (1016) x 105 (2667) 4469 (2029) 61 589 (2229.6) 128 (3251.2) x 49 (1244.6) x 107 (2717.8) 4948 (2244) 72 693 (2623.3) 136 (3454.4) x 53 (1346.2) x 107 (2717.8) 4667 (2117) STANDARD ENCLOSURE NO TANK - 133 (3378) x 40 (1016) x 64 (1625.6) 9 90 (340.7) 133 (3378) x 40 (1016) x 77 (1956) 23 220 (832.8) 133 (3378) x 40 (1016) x 89 (2261) 36 350 (1324.9) 133 (3378) x 40 (1016) x 101 (2565) 53 510 (1930.6) 133 (3378) x 47 (1194) x 105 (2667) 61 589 (2229.6) 133 (3378) x 49 (1125) x 107 (2718) 72 693 (2623.3) 133 (3378) x 53 (1346) x 107 (2718) WT lbs (kg) - Enclosure Only Steel Aluminum 500 (227) 165 (75) LEVEL 1 ACOUSTIC ENCLOSURE NO TANK - 154 (3912) x 40 (1016) x 64 (1626) 9 90 (340.7) 154 (3912) x 40 (1016) x 77 (1956) 23 220 (832.8) 154 (3912) x 40 (1016) x 89 (2261) 36 350 (1324.9) 154 (3912) x 40 (1016) x 101 (2565) 53 510 (1930.6) 154 (3912) x 47 (1194) x 105 (2667) 61 589 (2229.6) 154 (3912) x 49 (1245) x 107 (2718) 72 693 (2623.3) 154 (3912) x 53 (1346) x 107 (2718) WT lbs (kg) - Enclosure Only Steel Aluminum 750 (340) 250 (112) LEVEL 2 ACOUSTIC ENCLOSURE NO TANK - 145 (3683) x 40 (1016) x 81 (2057) 9 90 (340.7) 145 (3683) x 40 (1016) x 84 (2134) 23 220 (832.8) 145 (3683) x 40 (1016) x 106 (2692) 36 350 (1324.9) 145 (3683) x 40 (1016) x 118 (2997) 53 510 (1930.6) 145 (3683) x 47 (1194) x 122 (3099) 61 589 (2229.6) 145 (3683) x 49 (1245) x 124 (3150) 72 693 (2623.3) 145 (3683) x 53 (1346) x 124 (3150) WT lbs (kg) - Enclosure Only Steel Aluminum 1000 (454) 330 (150) * All measurements are approximate and for estimation purposes only. Sound dba can be found on the sound data sheet. Enclosure Only weight is added to Tank & Open Set weight to determine total weight. Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings. Generac Power Systems, Inc. S45 W29290 HWY. 59, Waukesha, WI 53189 generac.com 2014 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0K5094-D / Printed in U.S.A. 11/11/14