PAGE: 1 OF 5 Flood optic General information 4" (102mm) 45/8" (118mm) Luminaire characteristics: Input load: 4.5 to 11.5W/foot Lumens: 214 to 491lm/foot (delivered) 36.7 to 50.8lm/W Source: White LED 3000: 85CRI. 4000: 80CRI. Lumen maintenance: >80% of initial lumens at 100000 hours (L80) LM80 (LED) / LM79 tested. 61/2" (166mm) optic Configuration: Multiple option of continue rows using three different lengths: 2, 4 and 5.5 feet. Optics: 14 grazer or 45 Flood optic. Mounting: Wall, ceiling or ground recessed with outer casing. Ground recessed must have adequate drainage. Body: Extruded aluminum body, diecast aluminum end caps, power supply box made of PPS (polyphenylene sulfide) and a transparent glass screen, factory sealed. Luminaire with flood optic are supplied with non skid glass. 51/8" (131mm) SIDE VIEW Electrical: Universal high efficiency electronic driver, rated at 50000 hours, 120277V. Two option for the feed point on either side of the luminaire run. Temperature of operation: 22 F to 113 F (30 C to 45 C) Dimming: Supplied standard with 010V dimmable power supply. VARIABLE LENGTH TOP VIEW Finish: Gray painted finish (RAL9007) coated with liquid acrylic paint with a high level of weather and UV ray resistance. Weight: 2,82lbs/ft. (1.27kg/ft.) Warranty: 5 year limited warranty, 10 year on paint finish. Certification: culus listed Ratings: Wet location, IP67 and I10. Load capacity: Maximum static load 2200 lb (1000 kg). Contact temperature: The maximum glass temperature is 104 F (40 C). DUE TO CONTINUOUS IMPROVEMENTS, THE INFORMATION HEREIN MAY BE CHANGED WITUT NOTICE.
PAGE: 2 OF 5 TECHNICAL DATA 3000, 85CRI 1111 lm 46.7 lm/w 3000, 85CRI 2392 lm 40.1 lm/w 3000, 85CRI Flood 2188 lm 36.7 lm/w 4000, 80CRI 1188 lm 49.9 lm/w 4000, 80CRI 2551 lm 42.7 lm/w 4000, 80CRI Flood 2336 lm 39.1 lm/w DUE TO CONTINUOUS IMPROVEMENTS, THE INFORMATION HEREIN MAY BE CHANGED WITUT NOTICE.
PAGE: 3 OF 5 CONFIGURATIONS Note NOMINAL LENGTHS Single elements can be combined to obtain dark spot free continuous run with a single feed point. SINGLE ELEMENTS L Installation 2' L : 1'115/8" (601mm) 4' L : 3'81/2" (1129mm) 5.5' Ground and wallrecessed using the outer casing included. For ground installation a drainage channel must be created or gravel inserted for drainage under the outer casing before installation, to guarantee the degreeof protection stated. For ceiling or wall application in drywall, wood and other materials the luminaire can be installed without back box, thickness to 1/8 to 11/8"(130 mm) L : 5'51/4" (1658mm) CONTINUOUS ROWS EAMPLES 6' L : 5'81/4" (1732mm) 7.5' L : 7'5" (2260mm) 9.5' L : 9'13/4" (2789mm) 11' L : 10'105/8" (3318mm) 13' L : 12'103/8" (3920mm) 15' L : 14'10" (4522mm) 16.5' 1/16 (2mm) L : 16'4" (4978mm) 18.5' L : 18'33/4" (5581mm) 22' L : 21'93/8" (6638mm) 24.5' L : 24'27/8" (7387mm) DUE TO CONTINUOUS IMPROVEMENTS, THE INFORMATION HEREIN MAY BE CHANGED WITUT NOTICE.
PAGE: 4 OF 5 WALL WASHER OPTICS M1* Back box for concrete installation A 77/8" (200mm) B 97/8" (250mm) M2* Back box with 1'101/2" safety cable + M3* Back box with 71/8" safety cable + only for and output A M4 Safety support L1'101/2" (570mm) cable kit and plate for ceiling application B M5 Safety support L71/8" (200mm) cable kit for wall application *Wiring box included The will be limited by : 1 ) THE LIGHTING FITURE CAPACITY OR 2) THE DIMMER CURRENT CARRYING CAPACITY Consult guidelines below to determine both values for you application. The lower value of theses 2 criterias will determine you max length LIGHTING FITURE CAPACITY CRITERIA FOR Guidelines based on fixture load of 5.5 ft luminaires generaly use to acheive longer lengths. FOR 277V FOR 120V Total Load (A) Fixture Load (A) Total Load (A) Fixture Load (A) 343ft 0.19A 6 0.1A 131ft 0.5A 283ft 0.23A 131ft 0.5A 283ft 0.23A Dimmer AWG14 120V or 277V WET LOCATION (Supplied) 010V DIMMER CURRENT CARRYING CAPACITY CRITERIA FOR See calculation example below based on a 30mA capacity dimmer. 5.5 ft luminaire with 3 ma current sink are generaly use to acheive longer lengths and therefore should be used in the calculation. DIMMER CURRENT CARRYING CAPACITY (ma) LUMINAIRE SIN CURRENT (ma) 120V or 277V MA. NUMBER OF LUMINAIRE x 5.5 ft MA. LENGTH 30 ma 3 ma 10 LUMINAIRES (5.2ft) x 5.5 ft 55ft AWG14 WET LOCATION (Supplied) Note: if no dimmer is used, only the lighting fixture capacity criteria is used. DUE TO CONTINUOUS IMPROVEMENTS, THE INFORMATION HEREIN MAY BE CHANGED WITUT NOTICE.
PAGE: 5 OF 5 T color Output Code Watt/Foot I.LCRL4 Lumen/Foot 4.5W/ft Wall Grazing Height (for 30mA dimmer capacity) Optic 230lm/ft 1316ft 3642ft 4000 I.LCRL4 491lm/ft I.LCRL3 4.5W/ft 214lm/ft 1316ft 3000 I.LCRL3 459lm/ft 3642ft I.LCRL4 450lm/ft 45 I.LCRL3 421lm/ft 45 45/8" 4" 4000 3000 RESET INFO ORDERING INFO I.LCR MODEL OUTPUT LED COLOR LENGTH OUTPUT LED COLOR Base L3 3000 High Flood optic L4 4000 UNV VOLTAGE NOMINAL LENGTH ' Refer to configurations table on page 3. 15 FINISH NA No accessories M1 Back box M2 Back box with 1'101/2" safety cable M3 Back box with 71/8" safety cable M4 1'101/2" safety cable M5 71/8" safety cable DUE TO CONTINUOUS IMPROVEMENTS, THE INFORMATION HEREIN MAY BE CHANGED WITUT NOTICE.