CM3-E Operation Manual DOK-347E / Rev.:1.01 KH / October 1999 Portable 3 turbine check meter

Similar documents
Operating instructions

English. Instruction and operation manual S 212. Dew point sensor

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

Instruction Manual. Ex-Time 40 / 50

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

Oil-free piston compressors KK and piston vacuum pumps KV

GARDEN HOSE UTILITY PUMP

Battery Charger Series EASY Charger

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

Meter FMT II. Operating manual. original operating manual. Translation of the

original operating manual Operating manual Manual flow meter FMOGne Translation of the Item-No.: ,

MV Series Motors Operation & Parts Manual

original operating manual Operating manual Translation of the Item-No.: ,

Operating Instruction for Flowmonitor. Model: DF-WM

US - UP2/OIL 12V US - UP2/OIL 24V

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

Battery Charger. Series EASY Charger. User s manual

Installation instruction Sound Booster Pro Active Sound

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Operating Instructions

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

10 Year Limited Warranty

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Sinewave Inverters. SWING 150VA and 300VA. User s manual

DC Master 24/ A

Power. On Your Terms.

BODAS Pressure sensor PR3 series 10

Installation manual wall-mounted distributor

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

This manual covers the following model:

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Instruction Manual. Ex-MP4

Instruction manual and installation guide Traction sheave brake TSB TSB

A Member of the. Integrated Metering Technologies

EF SERIES MOTORS OPERATION & PARTS MANUAL

SPARK PLUG CLEANING KIT OPERATING MANUAL

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA

Installation and operating instructions. Solar charge controller Solarix MPPT 1010 and Z Z

12V OIL & DIESEL PUMP MODEL NO: CFTP12

VAPORIX The Automatic Monitoring System for Active Vapour Recovery

Sinewave Inverters. SWING pro 200VA and 350VA. User s manual

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Exchange of rollers from the XTS-Mover

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

EX Series User Manual

SMB. Assembly and operating instructions Sprinkler measuring orifice SMB/SMB-OE. Sprinkler measuring orifice

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

SCOPELITE TIMING LIGHT OPERATING MANUAL

User Manual TABLE MAGNIFIER TL-70. User-friendly Manual ID: #05007

OWNER S MANUAL STOP. Models: Blade Master 1.5 HP 1500 Series Stationary Transfer Pump 1.5 Pump, Single Phase AC 110/220V, Non-Explosion proof

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive

Polymeric membrane for roof waterproofing. Uses Roof waterproofing membrane for exposed flat roofs: Loose laid and mechanically fastened

Printed: Doc-Nr: PUB / / 000 / 00

Technical Documentation

BA EN.=A. Ä.=A.ä. Operating Instructions. Gearbox. Type 12. / 52.

MOVE ON TO THE REAR BAR INSTALLATION

TBP SERIES PUMPS OPERATION & PARTS MANUAL

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

12v / 24v Diesel Transfer Pump Kit

SUNTURA SOLAR TRACKER

TIDALFLUX 2300 F Quick Start

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

A Member of the. Integrated Metering Technologies

SITRANS P measuring instruments for pressure

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Operating manual. High-voltage testing adapter VAS 6558A/30. Operating manual. Customer documentation Revision: 00 Version: 07/2018

Installation manual portable distributors

WATERFLUX 3070 Quick Start

Siemens AG Modern design and easy handling for charging at home or in the semi-public area

Angle sensor AN2 series 30

TPHK Series Immersible Pump

TPHK Series Immersible Pump

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

INSTRUCTION MANUAL MN7 series

Portable pressure calibrator, Wally Box III Model CPH7600

CONTENTS. Introduction. Thank you for purchasing the AlcoSense Precision+ breathalyser.

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

USE AND INSTALLATION HANDBOOK

Hot Pressing Device PQ-58

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

D Dräger Alcotest 3000 Breath Alcohol Measuring Device

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

Application cup for OptiFlex 2 GM03 manual powder gun

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Check valve type ER and EK

RESOL SBS 1000 * * Connection Operation

Andatech SOBERPOINT 3. Wall Mounted Breathalyser USER S MANUAL

UD and UC Gear pump unit

ELECTRIC FOLDING BIKE OWNERS MANUAL. e-power 36v. Go City-Lite

BYD B-Box Limited Warranty Letter

Instruction Manual. Pneumatic tank contents gauge Unitel # Distributed by

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

Analog Hydraulic Testers

Transcription:

-E DOK-347E / Rev.:1.01 KH / October 1999 Portable 3 turbine check meter

Contents 1 General Remarks... 1-1 1.1 About This Manual... 1-1 1.2 How to Use This Manual... 1-1 2 Approval... 2-1 2.1 Explosion Protection...2-1 2.2 Electromagnetic Compatibility... 2-1 2.3 Especially Important... 2-1 2.4 Intended Use... 2-2 2.5 General Application Information... 2-2 2.5.1 Measurement at a Splitted Tank Compartment... 2-2 3 Operation... 3-3 3.1 Functional Principle of the... 3-3 3.2 Initial Operation... 3-3 3.3 Measurement Operation... 3-3 3.3.1 Coupling/ Uncoupling... 3-3 3.3.2 Controls... 3-4 3.3.2.1 Display... 3-4 3.3.2.2 Keypad... 3-4 3.3.3 Measurement Procedure... 3-5 3.4 Storage... 3-5 4 Servicing... 4-1 4.1 Battery Replacement... 4-1 5 Technical Data... 5-1 5.1 Repairs and Replacement Parts... 5-1 6 Warranty and Service... 6-1 7 Appendix... 7-1 Descr. No.: DOK-347E Rev.: 1.01 KH / Date: 19.10.99 Page i

1 General Remarks 1.1 About This Manual We are sure that the excellent characteristics of the will justify the confidence you have placed in us by purchasing the equipment. We have made substantial efforts to supply you with a high performance, reliable device. Please read the instructions for use carefully before operating the for the first time. The instructions explain in detail the operation of the and give you valuable information. These instructions for use contain some information concerning your safety. Please also pass this information to other users. 1.2 How to Use This Manual This manual contains multiple information. Not all that is written here will be of use to you. In order to help you find the information you need, we created some orientation help. Page numbers Pages are numbered by chapter. Thus any update caused by further developing the will not mix up the numbering system. Pictographs The information in this manual ranges from intended use, formal instructions, concrete operating steps and feed-backs to good advice. For easier reference the information is marked with a special pictograph in the left marginal column. In this manual you will find the following symbols: Danger! In this case: Danger of explosion. Environment protection; recycling. Action that may damage the equipment. Action that may have legal consequences. Work step; concrete operation Feed-back positive Feed-back negative Advice, tip Descr. No.: DOK-347E Rev.: 1.01 KH / Date: 19.10.99 Page 1-1

2 Approval Important: Before operating the device for the first time, read the following items carefully and follow them. 2.1 Explosion Protection The has been designed for the flow measurement of flammable liquids in Classes AI and AIII on tank trucks. The must not be used for flow measurement in vapour recovery systems or for the discharge of fuel using feed pumps. The electronics have been certified by KEMA. EEx ia IIB T4; KEMA No. Ex-95.D.1282 X 2.2 Electromagnetic Compatibility The conforms to the law regarding electromagnetic compatibility and is labelled with the CE symbol. 2.3 Especially Important The measurement of gases, e.g. in vapour recovery systems, is prohibited. The must not be used for the discharge of fuel using a feed pump. The contains precision, high quality components. Therefore, mechanical influences which do not result from operation (e.g. through being dropped) must be avoided. The must only be installed on the vehicle using the holder specified by the manufacturer. Measurements which are subject to mandatory W&M certification must not be carried out with this device. Descr. No.: DOK-347E Rev.: 1.01 KH / Date: 19.10.99 Page 2-1

2.4 Intended Use The has been constructed solely for the volume measurement of low-viscosity mineral oils. The device is not intended for applications other than this; the manufacturer cannot be held liable for any resulting losses in this respect. The operating, servicing and maintenance conditions as defined by the manufacturer are included in the scope of intended use. The may only be used, serviced and maintained by persons who are familiar with the device and have been appropriately instructed about the hazards involved. Unauthorised modifications to the device exclude any liability on the part of the manufacturer for any resulting losses. 2.5 General Application Information The has been developed so that the product quantity discharged can also be determined on tank trucks without measurement systems. This means that the complete content of tank compartments does not need to be discharged. The discharged quantity can be determined conforming to the requirements. However, with measurement operation it must be taken into account that the is operated without a gas extractor, i.e. any air in the product is also metered with it. 2.5.1 Measurement at a Splitted Tank Compartment If a tank compartment must be splitted, we recommend to start the measurement on a full tank. This is the only way to get the exact value, cause the counts the pure product without any enhancement of air. So You get the use of the high precision of. The overleaped rest in the compartment can be investigated by the difference between the full-tank-quantity and the discharge-quantity. But if You start the measurement at the overleaped rest to empty, so You will get a big failure in the counted quantity, cause the product will be enhanced with a lot of air at the end. That will spoil the precision of the measurement significantly. Page 2-2 Rev.: 1.01 KH / Date: 19.10.99 Descr. No.: DOK-347E

3 Operation 3.1 Functional Principle of the The liquid flowing through the impeller-type meter sets the impeller rotating. The number of impeller revolutions is proportional to the flow volume. The rotating movement of the impeller blades is transferred without contact by a magnetoinductive sensor. These signals are evaluated by a special electronic system and shown on a display. The momentary flow rate in l/min and the total discharged volume in litres can be displayed. In addition a non-resettable totaliser is provided. 3.2 Initial Operation The is exported to foreign countries without any coupling. Suitable couplings must be mounted or ordered optionally. The setting of the appropriate SET-UP parameters has been carried out by the manufacturer. Important: Before operating the device for the first time, read the instructions for use carefully and follow them. 3.3 Measurement Operation 3.3.1 Coupling/ Uncoupling Mount the directly at the discharge coupling on the tank truck. Insert the optional coupling of the into the coupling on the tank truck. Orientate the so that the display can be read easily from above. Then clamp and lock the optional coupling to the other end of the. (See above.) Make sure that the gaskets in the truck couplings are in good condition. This is the only way to ensure that no leakage occurs in operation. Descr. No.: DOK-347E Rev.: 1.01 KH / Date: 19.10.99 Page 3-3

3.3.2 Controls All the required parameters on the are set in-house. For operation only the display panel and the three keys on the operating panel are relevant. 3.3.2.1 Display Two values are shown on the display. The upper value shows the quantity of liquid that has flowed through the device in litres (total). The lower value (smaller figures) indicates the momentary flow rate in litres per minute (l/min). 3.3.2.2 Keypad The has a total of three keys. On pressing the left key (ACCUM. TOTAL) the so-called cumulative flow is shown on the upper display in litres. This value is only visible while the key is pressed. This value cannot be reset to zero The central key (RESET) is used for zeroing the display. Once the key is pressed, the display is set to zero. The right key (PROG) is only used for programming the. Since this procedure is carried out by the manufacturer, this key has no significance for the operation of the. The device has no ON/OFF switch. It always remains ready for operation. The current consumption is minimised by an internal circuit. Page 3-4 Rev.: 1.01 KH / Date: 19.10.99 Descr. No.: DOK-347E

3.3.3 Measurement Procedure Measurement with the must be carried out in the following steps: Step 1: Remove the from the container. Step 2: Check the pipe interior for contamination or damage. The impeller must turn easily and then stop abruptly. Step 3: Check the display; the upper and lower displays must indicate zero. If the upper display indicates a value, press the <RESET> key. The display should now indicate zero. Step 4: Remove the cover cap from the product coupling on the vehicle. Step 5: Couple the to the vehicle; couple the hose (see Chapter 3.3.1). The measurement procedure can now be started. The description only refers to the operation of the. Of course, all other conditions relevant to the discharge of a fuel must be fulfilled. Step 6: Remove the product hose to the buried tank from the after termination of the discharge. Be sure that that no fuel flows into the ground. 3.4 Storage A special vibration-absorbing container must be used for storing the. If the is not transported in such a container and damage is caused, then no guarantee claims can be considered. Descr. No.: DOK-347E Rev.: 1.01 KH / Date: 19.10.99 Page 3-5

4 Servicing The has been designed so as to restrict the servicing work to a minimum. Each time the meter is used, it must be checked whether the meter impeller wheel turns easily. Lubrication of the impeller bearing is provided by the working fluid. Therefore never blow out the with compressed air. Damage to the bearing may occur. With the regular safety inspections must be carried out, according to ElexV. Para. 12 and VBG 4. 4.1 Battery Replacement When the battery service life expires, after about 2 years, this is indicated on the display with low bat. The batteries must be replaced when this indication appears. Important: The is a so-called intrinsically safe component and is approved by an official office with regard to the explosion protection. Therefore only genuine replacement batteries must be used. The voltage supply for the is provided by two batteries. Only one battery must be replaced at a time, because otherwise all the settings will be deleted. Unscrew the four mounting screws on the membrane keypad to change the batteries. Then remove the membrane keypad and place it on a clean surface. The connecting lead to the sensor is of sufficient length and does not need to be removed. Now pull off the connecting lead between the battery and electronics from the electronics. Fit the new battery. Ensure that the batteries are firmly mounted with the appropriate cable ties. If the cable ties are not pulled tight, damage may occur later in operation. Descr. No.: DOK-347E Rev.: 1.01 KH / Date: 19.10.99 Page 4-1

5 Technical Data Operating temperature - 20 to + 60 C Permissible pressure 10 bar Mating dimensions 3 thread on request Material (in medium contact) Aluminium; stainless steel Weight approx. 8 kg Measurement range 250-2000 l/min Measurement accuracy +/- 5 % in above measurement range at viscosities between 0.6 and 5 mm 2 /s Liquids Low-viscosity mineral oils; petrol, kerosene and diesel Dimensions 170 mm wide; 290 mm high; 350 mm long Voltage supply Battery service life Display Total Accumulated total Flow rate Two lithium batteries about 2 years LCD display, constantly ready for operation 7-figure display; 10 mm high See above 4-figure display; 8.5 mm high Splash-proof Conforming to IP 65 5.1 Repairs and Replacement Parts Repairs to the impeller or the electronics must only be carried out by the manufacturer. Also the replacement of components can only be carried out by the manufacturer, because in this case recalibration is necessary. Only replacement parts from F. A. Sening must be used: An overview of the available replacement parts is given in the Replacement Parts Drawing 71.250223 (see Appendix). Descr. No.: DOK-347E Rev.: 1.01 KH / Date: 19.10.99 Page 5-1

6 Warranty and Service In addition to the dealer's legal warranty in the purchase agreement we give the end user a warranty for this device on the following conditions: 1. The warranty period is twelve months and starts at the time of delivery of the device by F. A. Sening. With electronic products the registration form must have been received at Sening fully completed and signed by the installation department. 2. The warranty includes the rectification of all device damage or defects occurring within the warranty period and which can be shown to be due to material or production faults. The warranty does not include: - slight deviations from the intended quality which are insignificant for the value or usefulness of the device, - damage or defects due to connection other than as specified, improper handling or nonobservance of the installation guidelines and instructions for use, - damage from the chemical and electrochemical effects of water or other liquids, electrical or electromagnetic influences and generally from abnormal ambient conditions, - damage due to external effects such as damage in shipment, damage due to shock or impact, the effects of the weather or other natural phenomena. 3. The right to claim under warranty becomes invalid if repairs or tampering have been carried out by persons not authorised by us for the work or if our devices have been fitted with supplementary parts or accessories which are not suitable for our devices and not released by us for that purpose. 4. The warranty service is carried out, free of charge and according to our choice, by repairing defective parts or replacing them by perfect parts. Replaced parts become our property. 5. During the first six months of the warranty period the warranty service is carried out without billing. Thereafter, travelling times, travelling costs and working time for the service staff and any transport costs occurred are billed or not reimbursed. 6. Work under warranty does not imply any lengthening of the warranty period nor does it initiate a further period of warranty. The warranty period for installed replacement parts terminates with the end of the warranty period for the complete device. 7. More far-reaching or additional claims, in particular those for compensation of losses or consequential losses outside of the device are expressly excluded, provided no liability is deemed mandatory in law. Descr. No.: DOK-347E Rev.: 1.01 KH / Date: 19.10.99 Page 6-1

Important Note All explanations and technical details given in this documentation have been produced and edited by the author with the greatest care. However the possibility of errors cannot be completely eliminated. F. A. Sening GmbH would be very grateful for the notification of any errors found. Our service department would be pleased to advise and help you. You can reach them under: Regentstrasse 1 D-25474 Ellerbek Germany Tel.: +49 (0) 4101 / 304 0 (Switchboard) Tel.: +49 (0) 4101 / 304 288 (Hotline) Fax: +49 (0) 4101 / 304 289 (Service) Page 6-2 Rev.: 1.01 KH / Date: 19.10.99 Descr. No.: DOK-347E

7 Appendix Quotation Drawing -E Drawing No.: E51.250337 Replacement Parts Drawing -E Drawing No.: E71.250337 Explosion Protection Approval Descr. No.: DOK-347E Rev.: 1.01 KH / Date: 19.10.99 Page 7-1