AIR CONDITIONING PRODUCTS COMPANY

Similar documents
When Time is Everything... We Manufacture in Days - Not Weeks!

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

ARROW INDUSTRIAL PRODUCTS

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

PC-125x Counter-Balanced Backdraft Damper

Motorized Fire Dampers

FADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type.

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

SD-1250 and SD-1600 Series Smoke Dampers

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

VCD-23. Low Leakage CONTROL DAMPER

Air Measuring Products AMD AMS IAQ

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

AMD-33 Air Measuring Station with VCD-33 Control Damper

ID-141x 12-Gauge Hat Channel Industrial Damper

VCD-23. Flange Options. Size Limitations

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

VCD-23 Low Leakage CONTROL DAMPER

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

Model VCD-20 3V CONTROL DAMPER

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

ARROW UNITED INDUSTRIES

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

FSD60/MFSD60 Multi-blade Fire Damper

Model VCD-43 Extruded Airfoil Blade Control Damper

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

2520- EC Motor Speed Controller

Introduction to Johnson Controls Dampers

Model FSD-212. Combination FIRE SMOKE DAMPERS

L O U V E R S & D A M P E R S

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

XeteX, Inc. All Rights Reserved.

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

MOTORIZED VOLUME DAMPER

HCD-230 Industrial Control Damper

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Direct Gas-Fired Heating

A Fläkt Woods Company. Model PFB Panel Exhaust Fans 24" 72" Diameter Bulletin PF-1410 July 2003

Thermal Isolation. Break

A Complete Line of Quality Products for Marine Applications

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

BD-1600 Balancing/Zone Control Damper

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

RD-2000 Round Control Dampers

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

GRAVITY INTAKE AND EXHAUST ROOF VENTILATORS

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

SECTION CONTROL DAMPERS

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

Filtered Kitchen Supply Packaged Ventilator

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

AL-Maraj Central A/C Systems Accessories Mfg Co.

Model FSD-331 Combination Fire Smoke Dampers

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

2SHE Series Direct-Drive Shutter Fans

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

forward curved inline duct blowers

Thermal. Dimensions Torque Rotating. Rotating Capacity lb.ft. HPS/Min. Lb-Ft

AD-1250 Airflow Measuring Station

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

Twin City Fan & Blower

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

MODEL OAL. Water Penetration. Water Penetration. Free Area OAL PERFORMANCE REGISTERS GRILLES &

SECTION AXIAL HVAC FANS

SECTION HVAC POWER VENTILATORS

GRAVITY VENTILATORS SIZING

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

DAMPERS WE CONTROL AIR

Transcription:

Quality Products for Motorized Dampers AIR CONDITIONING PRODUCTS COMPANY Wall Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga ble Shutter Drainable Louver Supply Damper Fiberglass Shutter Combination Louve Stainless Steel Shutter Ajustable Fixed Louver Volume Control Damper PVC Shutte Wall Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga ble Shutter Drainable Louver Supply Damper Fiberglass Shutter Combination Lou er Stainless Steel Shutter Adjustable Fixed Louver Volume Control Damper PVC Shutter Wall Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Lou er Gable Shutter Drainable Louver Supply Damper Fiberglass Shutter Combination Louver Stainless Steel Shutter Adjustable Fixed Louver Volume Control Damper PVC Shutter Wall Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Wa Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Gable Shutter Drainable Louver Supply Damper Fiberglass Shutter Combination Louve Stainless Steel Shutter Ajustable Fixed Louver Volume Control Damper PVC Shutte Wall Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga ble Shutter Drainable Louver Supply Damper Fiberglass Shutter Combination Lou er Stainless Steel Shutter Adjustable Fixed Louver Volume Control Damper PVC Manufacturer SHUTTERS DAMPERS LOUVERS Air Conditioning Products Company 30350 Ecorse Road, Romulus, Michigan 48174 Phone: 734.326.0050 Fax: 734.326.9632 www.acpshutters.com

Table of Contents Aluminum Motorized Damper (12-49 ) Model AMD-SP...4-5 Aluminum Motorized Damper (50-72 ) Model AMD-DP....................6-7 Galvanized Steel Motorized Damper (12-49 ) Model GMD-SP...8-9 Galvanized Steel Motorized Damper (50-72 ) Model GMD-DP............10-11 Extruded Aluminum Motorized Hat Channel Damper Model ACD...12-13 Installation Instructions Model AMD/GMD..............................15-16 Installation Instructions Model ACD....................................17-18

SUBMITTAL DRAWINGS 3

Aluminum motorized damper model Amd-Sp Heavy Duty Extruded Aluminum motorized damper with a 1 1 /2" flanged frame. It can be used for exhaust or supply applications and can be mounted in either a vertical or horizontal position. The damper comes standard with an internally mounted 120/240 volt single phase motor (an end switch is std. on units 25" and above). A (C+3") B (C+1") C Standard Construction: Frame 2 deep x 1 1 /2 flanged x.125 thick Extruded Aluminum. D (E+3") E Blades 6 wide x.080 thick Extruded Aluminum. Parallel Blade Action. MOTOR Seals Stainless Steel Jamb Seals. 3 Tie Rod.125 thick Aluminum tie rods and blade clips. On-blade type. Bushings Nylon. Construction TIG welded frames. ⁹ ₃₂" x ¹ ₂ Slotted Mounting Holes ReaR view Closed BRACE BAR ¹ ₂" 2" Mounting Holes 9 /32 x 1 /2 slotted. 2" BlADE Clip Finish Mill. Minimum Size 12 W x 12 H BlADE Clip TiE ROD TiE ROD link Maximum Size 49 W x 49 H link MOTOR Performance Criteria: 3500 fpm Maximum Velocity. 4 wg Maximum Pressure. 122 Degree Maximum Temperature. MOTOR 7¹ ₄" (Closed) 1¹ ₂" 10¹ ₄" (closed) 1¹ ₂" 8¹ ₂" (Open) side view (up to 24") 13³ ₄" (open) side view (25" to 49") Note: Above dimensions + or normal tolerance of.0625. 4

MoDEl AMD-SP Options (at additional cost) Custom Sizes. Blade Seals. optional Motors. MOTOR SPeCS: Damper Motor Model Power Supply Motor Temperature Sizes Manufacturer Number Required Type Range STANDARD: up to Multi-Products Ul-19-3050 120/240 V, 60 Hz 2 Position -40 to 212 Deg. F 24" x 24" Spring Return 25" x 25" Belimo TFC120-S 120/240 V 2 Position -22 to 122 Deg. F to 49" x 49" 50/60 Hz Spring Return OPTIONAL: All Sizes Belimo TF24-SR(-S) 24 V, 50/60 Hz Modulating -22 to 122 Deg. F STANDARD SIzeS overall (A & D) Inside (C & E) Required (B) Est. Frame Frame Hole Face Free Est. Part No. Dimension Dimension opening Area Area Shipping (width X height) (width X height) (width X height) (Sq. Ft.) (Sq. Ft.) Weight AMD 12" 15" x 15" 12" x 12" 13" x 13" 1.00 0.84 10 AMD 16" 19" x 19" 16" x 16" 17" x 17" 1.78 1.67 12 AMD 20" 23" x 23" 20" x 20" 21" x 21" 2.78 2.05 15 AMD 24" 27" x 27" 24" x 24" 25" x 25" 4.00 3.59 17 AMD 30" 33" x 33" 30" x 30" 31" x 31" 6.25 5.68 36 AMD 36" 39" x 39" 36" x 36" 37" x 37" 9.00 8.25 47 AMD 42" 45" x 45" 42" x 42" 43" x 43" 12.25 11.31 55 AMD 48" 51" x 51" 48" x 48" 49" x 49" 16.00 14.84 67 Note: Dimensions are approximate due to normal tolerances in the manufacturing process. Estimated Free Area calculation is based upon the following formula: MD[A+B+ (N x C)]/144. Free Area x FPM = CFM; actual performance may vary. limited warranty All products manufactured are warranted by Air Conditioning products Company (ACp) to be free from original defects in workmanship for a period of one year from date of shipment, under conditions of normal use and service. ACp will replace or repair any defective parts upon return to our plant, freight prepaid. This limited warranty will, in no way, include the payment of labor charges for field replacement of defective parts, installation, repairs of adjustments, or any other work done. Back charges will not be accepted for any reason unless ACp has given prior written permission, nor will ACp be responsible for consequential damages of any character, no limited warranty expressed or implied will supersede the foregoing. manufactured for air Conditioning products Co. 30350 Ecorse Road Romulus, MI 48174 acpshutters.com 5

Aluminum motorized damper model Amd-dp Heavy Duty Extruded Aluminum motorized damper with a 1-1/2" flanged frame. It can be used for exhaust or supply applications and can be mounted in either a vertical or horizontal position. The damper comes standard with an internally mounted 24 to 240 volt single phase motor with an end switch. a (c+3") B (c+1") c Standard Construction: Frame 2 deep x 1-1/2 flanged x.125 thick Extruded Aluminum. Blades 6 wide x.080 thick Extruded Aluminum. Parallel Blade Action. Seals Stainless Steel Jamb Seals. d (e+3") e F (d / 2) Tie Rod.125 thick Aluminum tie rods and blade clips. On-blade type. ⁹ ₃₂" x ¹ ₂ Slotted mounting Holes ¹ ₂" 3" Bushings Nylon. ReaR view Closed Construction TIG welded frames. BRace BaR 2" Mounting Holes 9 /32 x ½ slotted. Finish Mill. Minimum Size Double Panel 50 W x 50 H Maximum Size Double Panel 72 W x 72 H Blade clip tie Rod link motor Performance Criteria: 3500 fpm Maximum Velocity. 4 wg Maximum Pressure. 122 Degree Maximum Temperature. 10¹ ₄" (closed) 13³ ₄" (open) side view 1¹ ₂" Note: Above dimensions + or normal tolerance of.0625. 6

MoDEl AMD-DP Options (at additional cost) Custom Sizes. Blade Seals. optional Motors. MOTOR SPeCS: Damper Motor Model Power Supply Motor Temperature Sizes Manufacturer Number Required Type Range STANDARD: 50" x 50" Belimo NFBUP(-S) 24/120/240 V 2 Position -22 to 122 Deg. F to 72" x 72" 50/60 Hz Spring Return OPTIONAL: All Sizes Belimo NFB24-SR(-S) 24 V, 50/60 Hz Modulating -22 to 122 Deg. F STANDARD SIzeS overall (A & D) Inside (C & E) Required (B) Est. Frame Frame Hole Face Free Est. Part No. Dimension Dimension opening Area Area Shipping (width X height) (width X height) (width X height) (Sq. Ft.) (Sq. Ft.) Weight AMD 54" 57" x 57" 54" x 54" 55" x 55" 20.25 18.83 92 AMD 60" 63" x 63" 60" x 60" 61" x 61" 25.00 23.31 101 Note: Dimensions are approximate due to normal tolerances in the manufacturing process. Estimated Free Area calculation is based upon the following formula: MD[A+B+ (N x C)]/144. Free Area x FPM = CFM; actual performance may vary. limited warranty all products manufactured are warranted by air conditioning products company (acp) to be free from original defects in workmanship for a period of one year from date of shipment, under conditions of normal use and service. acp will replace or repair any defective parts upon return to our plant, freight prepaid. this limited warranty will, in no way, include the payment of labor charges for field replacement of defective parts, installation, repairs of adjustments, or any other work done. Back charges will not be accepted for any reason unless acp has given prior written permission, nor will acp be responsible for consequential damages of any character, no limited warranty expressed or implied will supersede the foregoing. manufactured for air Conditioning Products Co. 30350 Ecorse Road Romulus, MI 48174 acpshutters.com 7

Galvanized Steel Motorized damper Model GMd-Sp Heavy Duty Galvanized Steel motorized damper with a 1 1 /2" flanged frame. It can be used for exhaust or supply applications and can be mounted in either a vertical or horizontal position. The damper comes standard with an internally mounted 120/240 volt single phase motor (an end switch is std. on units 25" and above). a (C+3") B (C+1") C Standard Construction: Frame 2 deep x 1 1 /2 flanged x 14 gauge Galvanized Steel. d (e+3") e Blades 6 wide x 16 gauge Galvanized Steel. Parallel Blade Action. motor Seals Stainless Steel Jamb Seals. 3 Tie Rod 11 gauge Galvanized Steel tie rods and blade clips. On-blade type. Bushings Brass. Construction MIG welded frames. ⁹ ₃₂" x ¹ ₂ Slotted mounting Holes ReaR view Closed BraCe Bar ¹ ₂" 2" Mounting Holes 9 /32 x 1 /2 slotted. 2" Blade Clip Finish Galvanized. Minimum Size 12 W x 12 H Blade Clip tie rod tie rod link Maximum Size 49 W x 49 H link motor Performance Criteria: 3500 fpm Maximum Velocity. 4 wg Maximum Pressure. 122 Degree Maximum Temperature. motor 7¹ ₄" (Closed) 1¹ ₂" 10¹ ₄" (closed) 1¹ ₂" 8¹ ₂" (open) side view (up to 24") 13³ ₄" (open) side view (25" to 49") Note: Above dimensions + or normal tolerance of.0625. 8

MoDel GMD-SP Options (at additional cost) Custom Sizes. Blade Seals. optional Motors. MOTOR SPeCS: Damper Motor Model Power Supply Motor Temperature Sizes Manufacturer Number Required Type Range STANDARD: up to Multi-Products Ul-19-3050 120/240 V, 60 Hz 2 Position -40 to 212 Deg. F 24" x 24" Spring Return 25" x 25" Belimo TFC120-S 120/240 V 2 Position -22 to 122 Deg. F to 49" x 49" 50/60 Hz Spring Return OPTIONAL: All Sizes Belimo TF24-SR(-S) 24 V, 50/60 Hz Modulating -22 to 122 Deg. F STANDARD SIzeS overall (A & D) Inside (C & e) Required (B) est. Frame Frame Hole Face Free est. Part No. Dimension Dimension Opening Area Area Shipping (width X height) (width X height) (width X height) (Sq. Ft.) (Sq. Ft.) Weight GMD 12" 15" x 15" 12" x 12" 13" x 13" 1.00 0.84 14 GMD 16" 19" x 19" 16" x 16" 17" x 17" 1.78 1.67 21 GMD 20" 23" x 23" 20" x 20" 21" x 21" 2.78 2.05 25 GMD 24" 27" x 27" 24" x 24" 25" x 25" 4.00 3.59 32 GMD 30" 33" x 33" 30" x 30" 31" x 31" 6.25 5.68 53 GMD 36" 39" x 39" 36" x 36" 37" x 37" 9.00 8.25 67 GMD 42" 45" x 45" 42" x 42" 43" x 43" 12.25 11.31 83 GMD 48" 51" x 51" 48" x 48" 49" x 49" 16.00 14.84 98 Note: Dimensions are approximate due to normal tolerances in the manufacturing process. estimated Free Area calculation is based upon the following formula: MD[A+B+ (N x C)]/144. Free Area x FPM = CFM; actual performance may vary. limited warranty all products manufactured are warranted by air Conditioning products Company (acp) to be free from original defects in workmanship for a period of one year from date of shipment, under conditions of normal use and service. acp will replace or repair any defective parts upon return to our plant, freight prepaid. this limited warranty will, in no way, include the payment of labor charges for field replacement of defective parts, installation, repairs of adjustments, or any other work done. Back charges will not be accepted for any reason unless acp has given prior written permission, nor will acp be responsible for consequential damages of any character, no limited warranty expressed or implied will supersede the foregoing. manufactured for air Conditioning products Co. 30350 Ecorse Road Romulus, MI 48174 acpshutters.com 9

Galvanized Steel Motorized damper Model GMd-dp Heavy Duty Galvanized Steel motorized damper with a 1-1/2" flanged frame. It can be used for exhaust or supply applications and can be mounted in either a vertical or horizontal position. The damper comes standard with an internally mounted 24 to 240 volt single phase motor with an end switch. a (c+3") B (c+1") c Standard Construction: Frame 2 deep x 1-1/2 flanged x 14 gauge Galvanized Steel. Blades 6 wide x 16 gauge Galvanized Steel. Parallel Blade Action. Seals Stainless Steel Jamb Seals. d (e+3") e F (d / 2) Tie Rod 11 gauge Galvanized Steel tie rods and blade clips. On-blade type. ⁹ ₃₂" x ¹ ₂ Slotted mounting Holes ¹ ₂" 3" Bushings Brass. ReaR view Closed Construction MIG welded frames. BRace BaR 2" Mounting Holes 9 /32 x ½ slotted. Finish Galvanized. Minimum Size Double Panel 50 W x 50 H Maximum Size Double Panel 72 W x 72 H Blade clip tie Rod link motor Performance Criteria: 3500 fpm Maximum Velocity. 4 wg Maximum Pressure. 122 Degree Maximum Temperature. 10¹ ₄" (closed) 13³ ₄" (open) side view 1¹ ₂" Note: Above dimensions + or normal tolerance of.0625. 10

MoDel GMD-DP Options (at additional cost) Custom Sizes. Blade Seals. optional Motors. MOTOR SPeCS: Damper Motor Model Power Supply Motor Temperature Sizes Manufacturer Number Required Type Range STanDaRD: 50" x 50" Belimo NFBUP(-S) 24/120/240 V 2 Position -22 to 122 Deg. F to 72" x 72" 50/60 Hz Spring Return OPTiOnaL: All Sizes Belimo NFB24-SR(-S) 24 V, 50/60 Hz Modulating -22 to 122 Deg. F STanDaRD SizeS overall (A & D) Inside (C & e) Required (B) est. Frame Frame Hole Face Free est. Part No. Dimension Dimension Opening Area Area Shipping (width X height) (width X height) (width X height) (Sq. Ft.) (Sq. Ft.) Weight GMD 54" 57" x 57" 54" x 54" 55" x 55" 20.25 18.83 139 GMD 60" 63" x 63" 60" x 60" 61" x 61" 25.00 23.31 162 Note: Dimensions are approximate due to normal tolerances in the manufacturing process. estimated Free Area calculation is based upon the following formula: MD[A+B+ (N x C)]/144. Free Area x FPM = CFM; actual performance may vary. limited warranty all products manufactured are warranted by air conditioning products company (acp) to be free from original defects in workmanship for a period of one year from date of shipment, under conditions of normal use and service. acp will replace or repair any defective parts upon return to our plant, freight prepaid. this limited warranty will, in no way, include the payment of labor charges for field replacement of defective parts, installation, repairs of adjustments, or any other work done. Back charges will not be accepted for any reason unless acp has given prior written permission, nor will acp be responsible for consequential damages of any character, no limited warranty expressed or implied will supersede the foregoing. manufactured for air Conditioning Products Co. 30350 Ecorse Road Romulus, MI 48174 acpshutters.com 11

Aluminum motorized HAt CHAnnel damper model ACd Extruded Aluminum motorized volume control damper with a hat channel frame. It can be used for exhaust or supply applications and can be mounted in either a vertical or horizontal position. The damper comes standard with blade and jamb seals and an internally mounted 120/240 volt single phase motor with an end switch. Standard Construction: Frame 5 x 1 x.100 thick Extruded Aluminum Hat Channel. A Blades 7 wide maximum x.080 thick Extruded Aluminum. Parallel Blade Action. Seals Blade Extruded TPV (-70 deg. F to +280 deg. F). Jamb Stainless Steel. B Tie Rod On-Blade Type. Bushings Nylon. Axles Plated Steel Square. front view Motor 100 to 240 VAC, 50/60 Hz internally mounted motor. 5" Finish Mill. Minimum Size 8 W x 8 H BLADE IN CLOSED POSITION BLADE IN OPEN POSITION Maximum Size 48 W x 60 H Performance Criteria: 3500 fpm Maximum Velocity. 4 wg Maximum Pressure. 122 Degree Maximum Temperature. MOTOR 3" MAX 8" 14-1/2" side view Note: Above A and B dimensions are undersized by ¼ + or normal tolerance of.0625. 12

MODEl ACD Options (at additional cost) Custom Sizes. Optional Motors. MOTOR SPeCS: Damper Motor Model Power Supply Motor Temperature Sizes Manufacturer Number Required Type Range STANDARD: up to Belimo TFC120-S 120/240 V 2 Position -22 to 122 Deg. F 48" x 48" 50/60 Hz Spring Return 48" X 48" Belimo NFBUP-S 24/120/240V 2 Position -22 to 122 Deg. F to 48" x 60" 50/60 Hz Spring Return OPTIONAL: up to Belimo TF24-SR(-S) 24V, 50/60 Hz Modulating -22 to 122 Deg. F 48" x 48" 48"x 48" Belimo NFB24-SR(-S) 24V, 50/60 Hz Modulating -22 to 122 Deg. F to 48" x 60" STANDARD SIzeS Overall Est. Frame Face Free Est. Part No. Dimension Area Area Shipping (width X height) (Sq. Ft.) (Sq. Ft.) Weight ACD 12" 11.75" x 11.75" 0.96 0.37 5.0 ACD 16" 15.75" x 15.75" 1.73 1.05 7.0 ACD 20" 19.75" x 19.75" 2.71 2.13 10.5 ACD 24" 23.75" x 23.75" 3.92 3.17 13.0 ACD 30" 29.75" x 29.75" 6.15 5.11 18.5 ACD 36" 35.75" x 35.75" 8.88 7.56 25.0 ACD 42" 41.75" x 41.75" 12.11 10.49 34.0 ACD 48" 47.75" x 47.75" 15.84 13.90 42.0 Note: Dimensions are approximate due to normal tolerances in the manufacturing process. Estimated Free Area calculation is based upon the following formula: MD[A+B+ (N x C)]/144. Free Area x FPM = CFM; actual performance may vary. Limited warranty All products manufactured are warranted by Air Conditioning Products Company (ACP) to be free from original defects in workmanship for a period of one year from date of shipment, under conditions of normal use and service. ACP will replace or repair any defective parts upon return to our plant, freight prepaid. This limited warranty will, in no way, include the payment of labor charges for field replacement of defective parts, installation, repairs of adjustments, or any other work done. Back charges will not be accepted for any reason unless ACP has given prior written permission, nor will ACP be responsible for consequential damages of any character, no limited warranty expressed or implied will supersede the foregoing. manufactured for air Conditioning Products Co. 30350 Ecorse Road Romulus, MI 48174 acpshutters.com 13

INSTALLATION INSTRUCTIONS 14

OPERATING INSTRUCTIONS Motorized dampers ModeL amd/gmd 12" - 72" Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Description Heavy-duty dampers are constructed of extruded aluminum or galvanized steel frame and blades. Dampers can be mounted horizontally or vertically. For intake or exhaust applications. Tie rod linkage is attached to blades on fan side. Wiring Diagrams L1 Grd.120v Power Supply Lines L2 N L1 Switch Fan Motor Black Grd. Grd. Insulated White 12" to 24" - 120V, 60 Hz Red Green Shutter Motor 1 Neutral L1 Grd.240v Power Supply Lines L2 Wht Blk Switch 24 to 240 VAC Fan Motor Black Grd. Grd. Insulated Red 12" to 24" - 240V, 60 Hz Green Shutter White Motor N L2 2 Hot S1 S2 S3 NG NO 0 to 95 25" to 49" - 100 to 240V, 50/60 Hz NFBUP-S 50" to 72" - 24 to 240V, 50/60 Hz Dimensions A (C+3") B (C+1") 2" BrACE BAr 2" C BlADE Clip BlADE Clip tie rod tie rod D (E+3") link E link Motor F (D / 2) Motor 1¹ ₂" 3" 7¹ ₄" (Closed) 10¹ ₄" (closed) 1¹ ₂" ⁹ ₃₂" x ¹ ₂ Slotted Mounting Holes ReaR View Closed ¹ ₂" 8¹ ₂" (open) side View (up to 24") 13³ ₄" (open) side View (25" to 72") Note: Above dimensions + or normal tolerance of.0625. 15

MOTORIZED DAMPERS STANDARD MoToR SpecS: Damper Motor Model Power Supply Motor Temperature Sizes Manufacturer Number Required Type Range up to Multi-Products UL-19-3050 120/240 V, 60 Hz 2 Position -40 to 212 Deg. F 24" x 24" Spring Return 25" x 25" Belimo TFC120-S 120/240 V 2 Position -22 to 122 Deg. F to 49" x 49" 50/60 Hz Spring Return 50" x 50" Belimo NFBUP(-S) 24/120/240 V 2 Position -22 to 122 Deg. F to 72" x 72" 50/60 Hz Spring Return STANDARD SizeS Overall (A & D) Inside (C & E) Required (B) Est. Frame Frame Hole Face Free Part No. Dimension Dimension Opening Area Area (width X height) (width X height) (width X height) (Sq. Ft.) (Sq. Ft.) AMD / GMD 12" 15" x 15" 12" x 12" 13" x 13" 1.00 0.84 AMD / GMD 16" 19" x 19" 16" x 16" 17" x 17" 1.78 1.67 AMD / GMD 20" 23" x 23" 20" x 20" 21" x 21" 2.78 2.05 AMD / GMD 24" 27" x 27" 24" x 24" 25" x 25" 4.00 3.59 AMD / GMD 30" 33" x 33" 30" x 30" 31" x 31" 6.25 5.68 AMD / GMD 36" 39" x 39" 36" x 36" 37" x 37" 9.00 8.25 AMD / GMD 42" 45" x 45" 42" x 42" 43" x 43" 12.25 11.31 AMD / GMD 48" 51" x 51" 48" x 48" 49" x 49" 16.00 14.84 AMD / GMD 54" 57" x 57" 54" x 54" 55" x 55" 20.25 18.83 AMD / GMD 60" 63" x 63" 60" x 60" 61" x 61" 25.00 23.31 Note: Dimensions are approximate due to normal tolerances in the manufacturing process. Estimated Free Area calculation is based upon the following formula: MD[A+B+ (N x C)]/144. Free Area x FPM = CFM; actual performance may vary. limited warranty All products manufactured are warranted by Air Conditioning products Company (ACp) to be free from original defects in workmanship for a period of one year from date of shipment, under conditions of normal use and service. ACp will replace or repair any defective parts upon return to our plant, freight prepaid. this limited warranty will, in no way, include the payment of labor charges for field replacement of defective parts, installation, repairs of adjustments, or any other work done. Back charges will not be accepted for any reason unless ACp has given prior written permission, nor will ACp be responsible for consequential damages of any character, no limited warranty expressed or implied will supersede the foregoing. manufactured for air Conditioning products Co. 30350 Ecorse Road Romulus, MI 48174 acpshutters.com 16

Description The Extruded Aluminum motorized hat channel dampers may be used for exhaust or supply applications, in either a vertical or horizontal installation. The Hat Channel Frame may be installed in walls, curbs, or ductwork. The TPV blade seals and stainless steel jamb seals provide low leakage. The damper comes with a 100-240 VAC 50/60 Hz actuator with internal spring return in case of loss of power. Installation ENSURE STRUCTURAL INTEGRITY OF WALL BEFORE BREACHING. 1. Cut opening required for correct damper size. 2. Do not force the damper into opening. 3. Damper must be installed square and free from racking. Damper must operate freely. 4. Follow the General Safety information and Wiring Diagram. Wire damper motor as illustrated. INSTALLATION INSTRUCTIONS Aluminum motorized HAt CHAnnel damper model ACd HEAD FLASHING (not provided) CLIP ANGLES 1" X 1" X 1/8" (not provided) 5" BLADE IN CLOSED POSITION BLADE IN CLOSED POSITION BLADE IN OPEN POSITION BLADE IN OPEN POSITION VENTILATION DUCT ACTUATOR WOOD, BRICK OR CONCRETE WALL SILL FLASHING (not provided) ACTUATOR CLIP ANGLES 1" X 1" X 1/8" (not provided) 3" MAX 8" 14-1/2" Figure 1 - Wall and Duct Installation Note: Caulking, mounting hardware or flashing materials are not supplied with the damper. 100 to 240 VAC N L1 N L2 1 Neutral 2 Hot S1 S2 S3 NG NO 0 to 95 TFC120-S DAY Figure 2 - Wiring Diagram 17

MODEl ACD General Safety Information 1. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA) in the United States. 2. Motor must be securely and adequately grounded. This can be accomplished by wiring with a grounded, metal-clad raceway system, by using a separate ground wire connected to the bare metal of the motor frame, or other suitable means. Always disconnect power source before working on or near a motor or its connected load. If the power disconnect point is out-of-sight, lock it in the open position and tag to prevent unexpected application of power. 3. Protect the power cable from coming in contact with sharp objects. 4. Do not kink power cable and never allow the cable to come in contact with oil, grease, hot surfaces, or chemicals. 5. Make certain that the power source conforms to the requirements of your equipment. To avoid risk of electrical shock, more than one disconnect switch may be required to de-energize the device for servicing. 1 4 3 2 6 Figure 3 Repair Parts Illustration for Motorized Dampers Motor Parts List Ref. No. Description 1 50/60Hz Motor, 100 to 240v 2 Motor bracket 3 *Motor crankarm 4 *Swivel ball joints 5 *Connecting rod (Not Shown) 6 *Retaining Clip Limited Warranty All products manufactured are warranted by Air Conditioning Products Company (ACP) to be free from original defects in workmanship for a period of one year from date of shipment, under conditions of normal use and service. ACP will replace or repair any defective parts upon return to our plant, freight prepaid. This limited warranty will, in no way, include the payment of labor charges for field replacement of defective parts, installation, repairs of adjustments, or any other work done. Back charges will not be accepted for any reason unless ACP has given prior written permission, nor will ACP be responsible for consequential damages of any character, no limited warranty expressed or implied will supersede the foregoing. manufactured for air Conditioning Products Co. 30350 Ecorse Road Romulus, MI 48174 acpshutters.com 18

Air Conditioning Products Company (ACP) is family owned and operated for 3 generations. For over 60 years, ACP has been an industry leader specializing in manufacturing shutters, dampers, and louvers for the HVAC industry. Our broad customer base includes OEM s, leading HVAC manufacturers, national and regional distributors, as well as industry specific companies. Located in Romulus, Michigan (near Detroit), our state of the art manufacturing facility (over 100,000 sq. ft. of manufacturing space) allows us to quickly deliver products that will fulfill your requirements for quality and reliability in most air control applications. Our high volume capability combined with short lead times allows us to handle orders of all sizes and quantities. ACP s products are used in commercial/industrial, agricultural, and residential applications. In an ongoing effort to be a leader in our industry, we are active members of the Air Movement and Control Association International (AMCA) and its mission to promote the health and growth of the air movement and control industry consistent with the interest of the public. For more information about our product offering, visit us at www.acpshutters.com.